You are on page 1of 6

GAMESA G58-850 KW

BENEFITS

Optimum performance
for low winds

- Class IIIB/WZII.

- Pitch and variable speed


technology to maximize
energy production.

- Production of lighter
blades using fiberglass
and prepreg method.

- Compliance with the main


international Grid Codes.

- Aerodynamic design and


Gamesa NRS control
system to minimize noise
emissions.

- Gamesa SGIPE: Remote


monitoring and control
system with Web access.

- Over 4,600 Gamesa


G5X-850 kW wind turbines
installed.
Rotor Mechanical design
Diameter 58 m Drive train with main shaft supported by two spherical bearings
Swept area 2,642 m2 that transmit the side loads directly to the frame by means of the
bearing housing. This prevents the gearbox from receiving
Rotational speed Variable 14.6 - 30.8 rpm, towers 55 and 65m additional loads, reducing malfunctions and facilitating its
Variable 16.2 - 30.8 rpm, torre 44m service.
Rotational direction Clock Wise (front view)
Weight (incl. Hub) Approx. 12 T
Top head mass Approx. 35 T
Brake
Aerodynamic primary brake by means of full-feathering blades. In
Blades addition, a hydraulically-activated mechanical disc brake for
emergencies is mounted on the gearbox high speed shaft.

Number of blades 3
Length 28.3 m
Lightning protection
Airfoils NACA 63.XXX + FFA-W3
Material Epoxy reinforced glass fibre The Gamesa G58-850 kW wind turbine generator uses the total
lightning protection system, in accordance with standard IEC
Total blade weight 2,400 kg 61024-1. This system conducts the lightning from both sides of
the blade tip down to the root joint and from there across the
nacelle and tower structure to the grounding system located in
Tubular Tower the foundations.
As a result, the blade and sensitive electrical components are
Modular type Height Weight protected from damage.
2 sections 44 m 45 T
3 sections 55 m 62 T
3 sections 60 m 72 T
Control System
3 sections 65 m 79 T - The Generator is a doubly fed machine (DFM), whose speed and
3 sections 71 m 86 T power is controlled through IGBT converters and PWM (Pulse
Width Modulation) electronic control.
- Benefits:
Gearbox Active and reactive power control.
Low harmonic content and minimal losses.
Type 1 planetary stage / 2 helical stages Increased efficiency and production.
Prolonged working life of the turbine.
Ratio 50 Hz 1:61.74
Cooling Oil pump with oil cooler
Oil heater 1.5 kW Gamesa SGIPE
Gamesa SGIPE and its new generation Gamesa WindNet (wind
Generator 850 kW farm control systems), developed by Gamesa, that allow realtime
operation and remote control of wind turbines, meteorological
Type Doubly-fed machine mast and electrical substation via satellite-terrestrial network.
Modular design with control tools for active and reactive energy,
Rated power 850 kW noise, shadows and wake effects. TCP/IP architecture with a Web
Voltage 690 V ac interface.

Frequency 50 Hz
Protecction class IP 54
SMP Predictive Maintenance System
Number of poles 4
Rotational speed 900:1,900 rpm Predictive Maintenance System for the early detection of
(rated 1,620 rpm) potential deterioration or malfunctions in the wind turbines main
components.
Rated Stator Current 670 A @ 690 V
- Benefits:
Power factor (standard) 0.95 CAP - 0.95 IND at partial loads and Reduction in major corrective measures.
1 at nominal power.*
Increase in the machines availability and working life.
Power factor (optional) 0.95 CAP - 0.95 IND throughout Preferential terms in negotiations with insurance
the power range.* companies.
* Power factor at generator output terminals, at low voltage side before transformer input terminals. Integration within the control system.
Noise control Grid connection
Aerodynamic blade tip and mechanical component design mini- Gamesas doubly-fed wind turbines and Active Crowbar and over
mize noise emissions. In addition, Gamesa has developed the sized converter technologies ensure the compliance with the most
Gamesa NRS noise control system, which permits programming demanding grid connection requirements.
the noise emissions according to criteria such as date, time or Low voltage ride-through capability and dynamic regulation of
wind direction. This achieves the goals of local regulation com- active and reactive power.
pliance as well as maximum production.

1 2 3 4 5 6 7 8 9 10

19 18 17 16 15 14 13 12 11

1. Service crane 6. Main shaft with two 10. Hub cover 15. Yaw ring
2. Generator bearing housings 11. Blade bearing 16. Brake
3. Cooling system 7. Rotor lock system 12. Bed frame 17. Tower
4. Top control unit 8. Blade 13. Hydraulic unit 18. Yaw gears
5. Gearbox 9. Blade Hub 14. Shock absorbers 19. Transmission.
High speed shaft

Power Curve Gamesa G58-850 kW Power curve calculation based on NACA 63.XXX and FFA-W3
airfoils.
(for an air density Calculation parameters: 50 Hz grid frequency; tip angle pitch
of 1.225 kg/m3) regulated, 10% turbulence intensity and a variable rotor speed
ranging from 14.6 - 30.8 rpm.

Speed (m/s) Power (kW)


900
3 9.7
800 4 31.2
5 78.4
700
6 148.2
Power kW

600 7 242.7
8 368.8
500
9 525.3
400
Cut-in speed: 3 m/s 10 695.0
11 796.6
300 Cut-out speed: 21 m/s
12 835.9
200 13 846.8
100
14 849.3
15 849.9
0 16 850.0
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17-21
17-21 850.0
Wind speed m/s
Polgono Industrial Agustinos, C/A s/n
31013 Pamplona, Spain
Tel: +34 948 309010
Fax: +34 948 309009
info@gamesacorp.com
www.gamesa.es

Germany Portugal
Wailandtstrasse 7 Edificio D. Joo II
63741 Aschaffenburg PARQUE DAS NAOES
Tel: +49 (0) 6021 15 09 0 Av. D. Joo II, lote 1.06.2.37 B
Fax: +49 (0) 6021 15 09 199 1990-090 Lisbon
E-mail: info@wind.gamesa.de Tel: +351 21 898 92 00
Fax: +351 21 898 92 99
Denmark
Vejlsvej 51 United Kingdom
8600 Silkeborg Rowan House Hazell Drive
Tel: +45 87 229205 / 9204 NEWPORT South Wales NP10 8FY
Fax: +45 87 229201 Tel: +44 1633 654 140
Fax: +44 1633 654 147
France
Parc Mail United States
6 Alle Joliot Curie, btiment B 1 Ben Fairless Drive - Ste. 2
69791 Saint Priest Fairless Hills, PA 19030
Tel: +33 (0) 472 79 47 09 Tel: +1 215 736 8165
Fax: +33 (0) 478 90 05 41 Fax: +1 215 736 3985

Greece China
3, Pampouki Street Room 605,
154 51 Neo Psichiko CBD International Building
Athens No. 16, Yong An Dong Li,
Tel: +30 21 06753300 Chaoyang District
Fax: +30 21 06753305 Beijing 100022
Tel.: +86 10 8521 9768
Italy Fax: +86 10 8521 9760
Via Pio Emanuelli,1
Corpo B, 2 piano
00143 Rome
Tel: +39 0651531036
Fax: +39 0651530911

The specifications listed in this brochure may be subject to revision without prior notice.
The specifications listed are not contractually binding.
Printed: June 2007

You might also like