You are on page 1of 12

Back

MULTI-DISTRIBUTOR

MD-550
SAFETY INSTRUCTIONS
CAUTION CAUTION
The mounting location should satisfy Ground the equipment
the following conditions: cable armor to prevent
Sparate from radio transmitter, radar, mutual interference and
direction finder (at least 3m). electrical shock.
Locate the equipment away from air Observe the following compass safe
conditioner vents. distances to prevent deviation of a
Keep the equipment out of direct magnetic compass:
sunlight.
Standard Steering
Vibration should be minimal. compass compass
The location should be free of water
spray. MD-550 1.40 m 0.95 m

Turn off the power switch at the


Do not install this unit on the
switchboard before beginning the
overhead.
installation.
Do not use the cable having a
diameter greater than 11.7 mm.

i
TABLE OF CONTENTS

System Configuration ..........................................................................................................................1


Installation materials and Spare parts................................................................................................1
Cables ....................................................................................................................................................2
Mounting................................................................................................................................................2
Setting....................................................................................................................................................3
Fabrication of signal cable ..................................................................................................................3

SPECIFICATIONS........................................................................................................................... SP-1

PACKING LIST
OUTLINE DRAWING
INTERCONNECTION DIAGRAM

ii
System Configuration

Nameplate

12-24 VDC Attach label here.

Distribute NMEA from one Distribute NMEA from one


input to four output input to eight output
Input1 Output1 Input1 Output1
Output2 Output2
Output3 Output3
Output4 Output4
Input2 Output5 Output5
Output6 Output6
Output7 Output7
Output8 Output8

Distribute AD-10 format


When connecting by current loop, the
Input1 Output1 standard FURUNO receive circuit
Output2 (current limiter circuit: 470 ,
Output3 photocoupler: PC-400/900 are
included) accepts one unit per output
Output4
line. For connection of multiple
equipment, contact a FURUNO agent
or dealer for details.
Note: Write on the label the signal name of output 1-8 with an oil-based magic marker, and then
attach it below the nameplate. Clean the location before attaching the label.

Installation materials and Spare parts


Name Type Code No. Qty Remarks
Self-tapping
4x16 SUS304 000-162-605-10 4
screw CP14-06601
Label 14-070-1006 100-337-840-10 1
Fuse FGMB 125V 0.5A PBF 000-157-462-10 1 SP14-03001

1
Cables Mounting
Use the following cables (Japan Industrial This unit has not power switch. If you do not
Standard cables) or the equivalents. connect the MD-550 to power switchboard or
DPYC-1.5 Power cable circuit breaker, install an external power switch
(local supply), locating it near the MD-550.
Armor

Sheath

= 11.7 mm
Conductor
S = 1.5 mm 2
= 1.56 mm CR4 (POWER)
TTYCS-1 (Twisted pair cable) LEDs CR5 (IN1)
Current loop or RS-422 CR6 (IN2)
Jumpers
Armor Jumpers

Sheath

Shield
= 10.1 mm
Conductor
S = 0.75 mm 2
= 1.11 mm 21
6 5
14
TTYCS-1Q (Four core twisted)
AD-10 format POWER LED: Lights when the power is
supplied.
Armor IN1 LED: Blinks when data is input.
IN2 LED: Blinks when data is input.
Sheath
Shield Note: You can confirm working of output port
= 11.3 mm (by LED) by connecting it to the other
Conductor
S = 0.75 mm2 input port. (Refer to schematic diagram.)
= 1.11 mm CR5

We recommend use of the following crimp-on Input1 Output1


lug. Output2
FV1.25-M3 (Code no.: 000-538-110) Output3
= 6.6 mm Output4
CR6
4.0 mm Input2 Output5
= 3.7 mm Output6
Output7
Output8
Connection for confirming working of output
port

2
Setting TTYCS-1
77 3
Factory jumper settings are for current loop
and 1 in 4 out. Shield Armor
IN1 (OUT1-4) IN2 (OUT5-8)
JP1 (#1-#2), JP4 (#1-#2), 8
twist and cut
Current loop JP2 (#1-#2), JP5 (#1-#2), Earth wire fabrication
JP3 (#1-#2) JP6 (#1-#2) 55
JP1 (#2-#3), JP4 (#2-#3), 6 5
RS-422 JP2 (#2-#3), JP5 (#2-#3), 1
JP3 (#2-#3) JP6 (#2-#3)
Crimp-on lug

JP7 6
1 in 4 out #1-#2
Solder
1 in 8 out #2-#3
Earth wire
Note1: Put short jumper into connector in 15 10
6
same direction as before.
Note2: Do not short jumpers JP13 & JP14. They Vinyl tape
should be open.

Fabrication of signal cable


DPYC-1.5 TTYCS-1Q
77 3 77 3

Sheath Armor Shield Armor

8
Cut the sheath. twist and cut
15 10 Earth wire fabrication
6 55
6 5
Vinyl tape
1

Crimp-on lug
1 Crimp-on lug
6

Solder
Earth wire
15 10

Vinyl tape

3
SPECIFICATIONS OF MULTI-DISTRIBUTOR
MD-550

This equipment is used for distribution of navaid data from navigation equipment. It provides four
outputs each from two independent inputs or eight outputs from one input by changing an
internal setting. AD-10 format signal is also available to distribute four outputs from one input.

1. Port Input: 2 ports (data / shift lines)


Output: 8 ports (4 output for one input)
2. Type of Signal Serial Signal
Input: IEC 61162-1 or NMEA 0183 Ver. 1.5/2.0
(RS-422 or current loop)
Output: IEC 61162-1 (RS-422)
3. Transmission Rate 4800 bps to 38400 bps
4. Power Supply 12-24 VDC: 0.25-0.15 A
5. Coating Color 2.5G7/2 Newtone No.5

SP-1 E4408S01B
A-1
14CK-X-9851 -4 1/1

MD-550
N A M E O U T L I N E DESCRIPTION/CODE Q'TY
UNIT

MD-550 1
MULTI-DISTRIBUTOR
000-043-102-00
SPARE PARTS

SP14-03001 1
SPARE PARTS
004-010-880-00
INSTALLATION MATERIALS

CP14-06601 4
INSTALLATION MATERIALS
001-011-190-00
DOCUMENT
(
OME-44080-* 1
OPERATOR'S MANUAL
000-809-267-0*
()
OMJ-44080-* 1
OPERATOR'S MANUAL
000-809-266-0*

/
TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM. THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER
PRODUCT. QUALITY IS THE SAME.
DIMENSIONS IN DRAWING FOR REFERENCE ONLY. 14CK-X-9851
D-1
1 2 3 4

AD-10 NMEA
FOR AD-10 FORMAT FOR NMEA DATA
MD-550 MD-550
*1 TB1 TB1 *1 *1 TB1 *2 TB1 *1
AD-10 TTYCS-1Q 1 DATA-H DATA-A 4 TTYCS-1Q AD-10 OUT1 NMEA TTYCS-1 1 RD1-A/RD1-H TD1-A 4 TTYCS-1 OUTPUT DATA1
10m MAX. 2 DATA-C DATA-B 5 10m MAX. (DATA-IN) 100m MAX. 2 RD1-B/RD1-C TD1-B 5 100m MAX. NMEA
A INPUT No.1
18 SHIFT-H SHIFT-A 21 3 FG FG 6
19 SHIFT-C SHIFT-B 22 *1
TTYCS-1 OUTPUT DATA2
20 FG FG 23 JP7 TD2-A 7
*1 100m MAX. NMEA
TD2-B 8
TTYCS-1Q AD-10 OUT2
DATA-A 7 1-INPUT, 8-WAY FG 9
DATA-B 8 10m MAX. DATA-OUT *1
DISTRIBUTION No.1 TTYCS-1
SHIFT-A 24 TD3-A 10 OUTPUT DATA3
REQUIRES CHANGING 100m MAX. NMEA
SHIFT-B 25 JP7 SETTING. TD3-B 11
FG 26 FG 12
*1 *1
DATA-A 10 TTYCS-1Q AD-10 OUT3 TTYCS-1 OUTPUT DATA4
TD4-A 13
10m MAX. 100m MAX. NMEA
DATA-B 11 TD4-B 14
SHIFT-A 27 FG 15
SHIFT-B 28 NC 16
FG 29 *1 TB1 *2 *1
*1 NMEA TTYCS-1 18 RD2-A/RD2-H TTYCS-1 OUTPUT DATA5
TD5-A 21
TTYCS-1Q AD-10 OUT4 (DATA-IN) 100m MAX. 100m MAX. NMEA
DATA-A 13 19 RD2-B/RD2-C TD5-B 22
DATA-B 10m MAX. No.2
14 20 FG FG 23
SHIFT-A 30 *1
SHIFT-B 31 TD6-A 24 TTYCS-1 OUTPUT DATA6
B FG 32 TD6-B 25
100m MAX. NMEA
33 2-INPUT, 4-WAY FG 26
DISTRIBUTION DATA-OUT *1
(DEFAULT SETTING No.2
TD7-A 27
TTYCS-1 OUTPUT DATA7
100m MAX. NMEA
TD7-B 28
FG 29
*1
TTYCS-1 OUTPUT DATA8
TD8-A 30
TD8-B 31 100m MAX. NMEA
*1 TB1 *1 TB1 FG 32
12-24VDC DPYC-1.5 12-24VDC DPYC-1.5
34 V-IN(+) 34 V-IN(+) NC 33
17 V-IN(-) 17 V-IN(-)

GND GND
IV-1.25SQ. IV-1.25SQ.

C DRAWN TITLE
Nov. 10, '04 E. MIYOSHI MD-550
CHECKED
TAKAHASHI. T
APPROVED
Y. Hatai
NOTE *1. SHIPYARD SUPPLY. SCALE MASS NAME
*2. DEFAULT SETTING: CURRENT LOOP. kg MULTI-DISTRIBUTOR
S-1

DWG No.
C4408-C01- G 14-070-5001-1 INTERCONNECTION DIAGRAM
FURUNO ELECTRIC CO., LTD.
The paper used in this manual
is elemental chlorine free.

FURUNO Authorized Distributor/Dealer

9-52 Ashihara-cho,
Nishinomiya 662-8580, JAPAN

Telephone : 0798-65-2111
Fax : 0798-65-4200

All rights reserved. Printed in Japan FIRST EDITION :NOV.


: NOV. 2001
B : JAN. 11, 2007
Pub. No. OME-44080
*00080926711*
( YOSH ) MD-550 *00080926711*
*00080926711*

*OME44080B00*
*OME44080B00*
*OME44080B00*

You might also like