Impedance Audiometer AT235h

AT235h
Applications
The AT235h is an automatic impedance
audiometer well suited for clinics doing
screening, as well as diagnostic work.
Neonatal screening programs will par-
ticularly appreciate the presence of
high probetone tympanometry, allowing
more reliable tympanometric results in
neonates.
Ease of operation has been the primary
design criteria, but not at the expense
of testing flexibility.
The test battery includes tympanome-
try, acoustic reflex testing, ipsilateral
and contralateral reflex decay testing,
eustachian tube function test and AC
audiometry.
Tympanometry is very fast, and for the
subsequent reflex test there is a choice
of two different automated test proto-
cols. Manual reflex testing is available
also for those who need to do more in
depth analyses, or if part of the auto-
matically obtained results needs modifi-
cation.
The choice between either a traditional
screening probe system or a clinical
probe system allows the instrument to
be well matched to the patient popula- Normal
tion.
Tympanometry
Interacoustics’ endless airflow tech-
Probe Systems High Frequency nique used in the AT235h is the perfect
The standard supplied probe is a clini- Tympanometry way to ensure proper function in diffi-
cal type with detached probe tip. In addition to the standard 226Hz pro- cult test situations, for example with
This allows for secure tests of e.g. betone tympanogram, it is possible to crying or fidgeting children. In such
acoustic reflex decay, and also makes record a similar tympanogram using a situations, an intermittent seal in the
fitting to neonatal ears easier. higher frequency probetone. As differ- initial test phase will never result in time
A traditional pencil type screening pro- ent screening protocols call for different consuming resetting periods.
be is available as an option. frequencies of the high probetone, the Another unique feature is the intelli-
AT235h offers 678Hz, 800Hz or 1000Hz gently controlled pump system, which
as selected by the user. incorporates an adaptive speed control.
Children’s Train A tympanogram recorded using one of This combines a very fast test speed
A train may be displayed on the screen, the high probetones is generally con- with high resolution of the tympano-
to get the attention of the child. Test sidered better suited for screening of gram peak that traditionally is only
results can be monitored simultaneous- neonates than tympanograms obtained available by using slower pump
ly with displaying the train. using the traditional 226Hz probetone. speeds.

A moving train may help to keep children High frequency screening tympanometry Tympanogram and reflex test results dis-
quiet during testing. records the IYI tympanogram. played simultaneously.
Two Automatic Reflex Audiometry
Tests Audiometry is available through an
Reflex testing is very easy, but allows independent headset with two phones
also those in need of versatility to con- (optional).
trol all details of the test. Two separate The test may be run manually or auto-
test protocols may be programmed and matically, and for patient comfort, the
either may be selected by the push of a maximum output may be reduced if
button. All parameters are easily pro- needed.
grammable by the end user if the sup-
plied tests are not optimum suited for Printing Options
test routines of the clinic. In addition to The built-in fast thermal printer allows
testing with a set of fixed intensities, printout of all test results. Alternatively
available automated functions include an ink-jet or laser printer may be con-
automatic intensity search and auto- nected directly to AT235h for printout of
matic test for reflex growth. test results. If used with one of Intera-
The AT235h does not restrict mixing of coustics’ databases or NOAH, printouts
ipsi and contra stimuli and also features are also available through the PC.
noise for stimulation. Printer share between AT235h and oth-
There are few limitations on storing and er Interacoustics audiometers is avail-
printing of reflex results, as more than able with the built in thermal printer.
40 reflexes may be stored per ear. The AT235h is also available without
Reflex test with full manual stimulus thermal printer as model AT235h-xp.
control is also available, and this manu-
al function also allows repeating or
changing test result obtained by one of Windows Based
the automatic test protocols. Software
All data obtained may be transferred to
one of the following Windows based
software programs:
PrintView enables monitoring of the
AT235h and the printing of test results.
In developing this software maximum
attention has been given to providing a
program which is easy to use.
IaBase95 is similar to PrintView but
incorporates a database for general
patient data and hearing aid informa-
A group of increasing stimuli for reflex
tion. Portability
NOAH hearing aid fitting software may A convenient lightweight carrying case
testing, clearly displays reflex growth.
also be used for storing data from the (optional) will hold the AT235h and all
AT235h. of its accessories.
Decay – Contra and
Ipsi
Acoustic reflex decay test is available
with ipsilateral stimulation as well as
with contralateral stimulation.

ETF Test
Test of the eustachian tube for ears
with normal eardrums is available.

Automated Eustachian Tube test is Various included and optional parts. An optional dedicated carrying case is
available. available.
AT235h Specifications
Standards: Maximum Intensities: Test types:
Safety: EN 60601-1, Class I, Type B Manual Audiometry.
EMC: EN 60601-1-2 Freq. Ipsi Contra Contra Audiometry Automatic Audiometry according to ISO 8253-1
Impedance: EN 61027/ANSI S3.39 Type 1 Hz TDH39 CIR22 AC dBHL AC dBHL (Patient controlled Hughson-Westlake).
Audiometer: EN 60645-1/ANSI S.3.39 Type 4 Tone TDH39 EARTone
3A Various:
Medical CE-mark: The CE-mark indi- RS232:
cates that Interacoustics A/S meets the 125 90 90
Input/output for computer communication. One
requirements of Annex VI of the Medical 250 - 110 90 110 105 mode allows an external PC to both monitor and
0123 Device Directive 93/42/EEC. Approval is
500 105 120 100 120 110 control the instrument. The control actions can be
made by TÜV - identification no. 0123. followed on the display and operation panel.
750 120 115 Online communication, where the measurement
Tympanometry: 1000 110 120 110 120 120 data are sent to an external PC, can be selected.
Probe tone:
Frequency: 226Hz all functions. 678Hz, 800Hz 1500 120 120 Keyboard:
1000Hz for traditional IYI-curve tympanometry 2000 105 120 110 120 120 Connection for external keyboard, standard PC
Level: 85 db SPL type.
3000 100 120 110 120 120
Gain Control: AGC
4000 100 120 110 120 115 Printer:
Air pressure: 6000 - 120 - 120 100 Built in fast thermal printer with paper width:
Control: Automatic 112 mm
Range: Default +200 to –400daPa 8000 - 110 - 110 95 Connection for external laser or ink-jet printer:
(max. +300 to -600daPa) WN 105 120 110 - - Language: HP PCL L3 for HP DeskJet and IBM
Safety limitation: -800 daPa and +600 daPa mode for Cannon Bubble jet.
Pressure change rate: Selectable in the set-up LPN 105 120 110 - -
between 50, 150 and >250 daPa/s or automatic HPN 105 120 110 - - Accuracy:
Compliance: Stimulation Frequencies:± 1 %
Range: 0.1 to 6.0 ml (numerical: 0.1 to 8.0 ml) For safety / comfort reasons an optional limitation Probe tone frequency: ±1 Hz
of maximum intensity is available. Probe tone level: 85 dB SPL ± 1.5 dB measured in
Function: an IEC126 acoustic coupler. AGC for ear canal
Automatic, where pump speed, start- and stop Contra Earphone: compensation.
pressure can be user-programmed in the set-up. THD39 or insert receiver CIR22 (optional) Pressure measurement: ± 5% or 10 daPa,
whichever is greater
Eustachian Tube Function Attenuator: 1dB or 5dB steps. Compliance measurement: ± 5% or 0.1 ml,
Williams test, for normal ear drums. whichever is greater
Memory:
Acoustic Reflex Functions: Internal memory for two ears. Examples of Compatible Windows Software:
Each ear: 6 Ipsi and 6 Contra recordings. Each IaBase95 Database Program.
Test Types:
may have up to 6 stimuli. Also, there is memory for PrintView for PC monitoring and printing
Automatic Reflex:
additional manual reflex recordings. (Total max. 78 IA-NOAH-Imp Module for interfacing to NOAH
Two independent user selectable protocols.
reflexes per ear).
Series of fixed intensities available.
Automated intensity search functions available for Construction: Plastic cabinet
threshold search and reflex growth indication. Audiometer Functions:
Free mixing of Ipsi and Contra. Patient Response: Power supply: UPS400 (Included) 100-240V
Manual Reflex: Connection for patient response switch.
Manual control of all stimuli. Warm up time: 10 minutes at room temperature
May also be used to redo part of automated test Outputs: (200 C).
results. Contra TDH39 headset may be used for audio-
Reflex Decay: metry. Consumption: 15VA, max. 45VA
Manual control, with stimulus duration of 10 sec. Double TDH39 Headset for audiometry (optional)
Ipsi or Contralateral Stimulation. Dimensions: LxWxH 36x26x10 cm/
14x10x4 inches
Weight: 2.8 kg / 6 lbs.

Air Freight Packing: 48x31x37 cm /


19x22.2x14.6 inches.
Gross weight: 6.5 kg / 12.4 lbs.

Or dering Infor mation


Probe option: Included Parts: Optional Accessories
Reklame & Tryk A/S 75 50 26 66 - Edition 1

AT235-ATP Standard Probe System AT235h-ATP Clinical Probe System TDH39 Audiometric Headset
TDH39 Single Contralateral Earphone EAR-Tone3A Insert Phones for Audiometry
Printer option: UPS400 External Switch Mode Power Supply ACC35 Carrying Case
AT235h-xp is identical to the AT235h but has no Power Cable (110/220V, please specify) CIR22 Contralateral Insert Phone
built-in printer. Suitable for installations where BET50 Box of 65 assorted Eartips APS2 Patient Signal
computer connection takes care of printing, or TPR35 3 Rolls of Recording Paper CAT-222 Calibration Unit 0.2 and 5 ml
where external printer is connected. PCR-AT235 Dust Cover CAT-227 Calibration Unit 0.2-0.5-1-2-3-4-5 ml
Operation/Service/Multilingual CE manuals IES-2 Impedance Ear Simulator

Manufactured by: Sales and Service in your area:


Interacoustics
Phone: +45 6371 3555
Fax: +45 6371 3522
E-mail: info@interacoustics.dk
Mail: Interacoustics,
DK-5610 Assens, Denmark
www.Interacoustics.dk