Medical Devices Sensor Systems

Modern sensors and measurement systems are helping to make medi-


cal interventions more secure, automate research, and to design
more ergonomic medical devices.

Sensors in
Medical Technology

housing
1 Measuring principle of
capacitive sensors: If a con-
stant alternating current is
flowing through, the ampli-
tude of the alternating vol-
tage is proportional to the
distance between sensor
and target guard ring capacitor

All photos and figures : MICRO-EPSILON MESSTECHNIK GmbH & Co. KG


field lines

measuring spot

L
et's start with capacitive dis- ter-accuracies and resolution, which is why these sensors are used
placement sensors. During ca- in high precision applications. For example, they are used in sur-
pacitive measurements, the gical procedures, where a perfect line of vision to the operating
sensor and target act as electrodes table is required. Here, the sur-
for the electrical capacitor (Figure 1). geon is often supported by a surgi- Fine positioning
If a constant alternating current is cal microscope. The microscope
flowing through, the amplitude of optics are attached to the long arms of a stand. The pivot joints re-
the alternating voltage is proportio- quire continuous adjustments to keep the microscope area of vi-
nal to the distance between sensor sion stable for the surgeon. This is where the capaNCDT capaci-
and target. Capacitive sensors are tive sensor is used. The system measures the distance to the refe-
very stable and provide nanome- rence area, which reflects the arm movement in the pivot joint. If

MED engineering INTERNATIONAL 2013 © Carl Hanser Verlag, Munich


16
Internet-PDF-Datei. Diese PDF Datei enthält das Recht zur unbeschränkten Intranet- und Internetnutzung, sowie zur
Verbreitung über elektronische Verteiler. Eine Verbreitung in gedruckter Form ist mit dieser PDF-Datei nicht gestattet.
MD110023
www.med-eng.de @

2 Confocal chromatic sensor scan-


ning the fill level of microtiters

even if the meniscus of a liquid is large. con-


focalDT sensors can be used for measurements on any
liquid. Miniature sensors with a diameter of four millimeters or
more can be arranged in rows to scan the entire width of the micro-
the reference titer plate.
displacement is too large,
the control mechanism will move wireSENSOR draw-wire sensors ensure optimum patient positio-
the arm back to its original position. Key bene- ning of operating tables. The sensor wire is wound around the
fits of this solution include its compact design and easy integra- drum (Figure 3) on one side and attached to the moving object on
tion of the system into an existing design. It also provides the sur- the other side. An encoder translates the movement created by
geon with a clear picture throughout the entire procedure. the extension of the wire into an electronic signal. An operating
table is modular in design and provi-
In certain cases, sensors even make it possible des many adjustment options for the
to switch from manual to automated proce- optimum positioning of the patient
dures, for example, in medical laboratories. In during an operation: table height,
this scenario active agents are manually filled horizontal position and multiple angle
into microtiter containers for batch testing. It features, e.g. for head, torso and legs.
is essential, but Measuring technology is required to
Filling level also challenging, read the positions of the various
measurement to measure each adjustable elements. Due to their
agent precisely. compact footprint, high precision and
During automated filling, the fill volume is con- long service life, draw-wire sensors
trolled automatically. However, small batches from Micro-Epsilon are the ideal
that are often used in medicine are pipetted choice. Typically, up to five draw-wire
manually. Typically, random samples are mea- sensors are mounted to an operating
sured, but this is not sufficient for 100 percent table. As well as standard sensors with
quality control. Confocal displacement mea- steel wires, there is also a choice of
surement is an excellent solution for such synthetic wire versions or sensors with
applications. During confocal chromatic mea- 3 Internal structure of a draw-wire sensor: plastic connectors that prevent any
surements lenses are used to separate white Beside sensors with steel wires, there is also a interference with X-ray or MRI scans.
choice of synthetic wire versions or sensors
light into different spectra, which is then fo-
with plastic connectors that prevent any inter-
cused perpendicular to the object (Figure 2). ference with X-ray or MRI scans In addition to draw-wire sensors,
A spectrometer is used to transmit the re- capacitive and confocal measuring
flected light to the CCD array: each position in systems for displacement and dis-
the CCD array now corresponds to one wavelength, i.e. the dis- tance measurements, Micro-Epsilon offers optical micrometers,
tance between target and sensor. This technology facilitates mea- temperature and colour sensors, laser sensors, and magneto-in-
surements to nanometer ductive measurement systems for medical technology, pharma-
resolutions. The confocalDT ceuticals and biotech industries.
Contact sensors successively scan
the microtiters in the plate,
MICRO-EPSILON MESSTECHNIK and the system measures
GmbH & Co. KG the distance from sensor to
D-94496 Ortenburg/Germany liquid to micrometer accu-
Phone +49 (0)8542 168-471 Dipl.-Phys. Johann Salzberger
Fax +49 (0)8542 168-90 racies. Standard confocal is Managing Director Marketing and Sales at
www.micro-epsilon.de sensors can be tilted which Micro-Epsilon Messtechnik in Ortenburg, Germany.
means they work reliably Johann.Salzberger@micro-epsilon.de

MED engineering INTERNATIONAL 2013