You are on page 1of 37

Power Hook for Industrial High Bay Luminaires

Furnished with Receptacle, Plug, 18" 16-3 SO Cord and Loop Fixture Hanger

CEC:
Listed for Ordinary (Unclassified) Locations

Applications
• Designed for suspension of HID, ­fluorescent and incandescent
lighting fixtures.
Features
• All hangers
— All fixture hangers protect fixture against wind and vibration
damage.
— Cushion type for added protection where lighting fixtures are
subjected to vibration.
• G-HBPH power hook for industrial luminaires
— Loop that suspends fixture cannot be removed until plug is
disconnected from power receptacle.
— 20 Amp plug, receptacle and cable are provided in all
POLES/HANGERS: NEC/CEC ORDINARY LOCATION FLEXIBLE FIXTURE HANGERS

voltages.
— Rotating plug after insertion locks plug in receptacle,
eliminating plug ­fall-out.
— Loop and hook provide flexible mounting, ideal in areas
where vibration is encountered.
Standard Materials
• Copperfree (4/10 of 1% max.) cast aluminum
Standard Finishes
• Powder coat epoxy
CEC Certifications and Compliances
• CSA Standard: C22.2 No. 9, C22.2 No. 250
• CSA Certified: 009349

Size (Inches) Voltage Catalog Number

3/4 120 G-HBPH-120

3/4 208 G-HBPH-208

3/4 240 G-HBPH-240

3/4 277 G-HBPH-277

3/4 347 G-HBPH-347

3/4 480 G-HBPH-480

3/4 600 G-HBPH-600

708 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Round Tapered Steel Poles

NEC/CEC:
Rated for Ordinary (Unclassified) Locations

Applications
• To mount single or multiple luminaires to heights from 6.1 to
11.9 m (20 to 39 ft).
Features 101.6
(4.0)
• 50.8 mm (2 in) pipe size tenon accepts a single luminaire, or 2,
3, or 4 luminaires with appropriate pole-top mounting bracket.
• Shafts are tapered, one-section
50.8 mm (2 in)
design of 11 gauge commercial quality steel with a minimum Pipe Size Tenon

POLES/HANGERS: NEC/CEC ORDINARY LOCATION ARCHITECTURAL


(60.5 mm (2-3/8 in) O.D)
yield strength of 55,000 psi after fabrication.
• Base plates are of structural quality hot-rolled steel with
guaranteed minimum yield strength of 36,000 psi.
• A 101.6 x 165.1 mm (4 in x 6-1/2 in) reinforced handhole with
cover and grounding lug 55.6 mm (14 in) above the pole base is
standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX.
• For galvanized finish add -GAL.

355.6
(14.0)

Dimensions may vary. Consult your local sales representative for specifications
Mounting Base Tube Max.
Height Base Size Bolt Circle Thickness Bolt Proj. Diameter Anchor Bolt Proj Area
m (ft) mm (in) mm (in) mm (in) mm (in) mm (in) Dia. x Lgth. Sq.M (Sq. Catalog
A Shaft Size  S BC T P D mm (in) Ft) Number 
165.1 x 94.0 x 6.1 25.4 x 1016
6.1 (20) 254.0 (10.0)  25.4 (1.0) 57.2 (2.25) 165.1 (6.5) 1.74 (18.7) G-PRTH-20
(6.5 x 3.7 x 20’) (1 x 40)
177.8 x 88.9 x 7.6 25.4 x 1016
7.6 (25) 266.7 (10.5)  25.4 (1.0) 57.2 (2.25) 177.8 (7.0) 1.34 (14.4) G-PRTH-25
(7.0 x 3.5 x 25’) (1 x 40)
203.2 x 96.5 x 9.1 25.4 x 1016
9.1 (30) 292.1 (11.5)  25.4 (1.0) 57.2 (2.25) 203.2 (8.0) 1.35 (14.5) G-PRTH-30
(8.0 x 3.8 x 30’) (1 x 40)
215.9 x 91.4 x 10.7 25.4 x 1016
10.7 (35) 304.8 (12.0)  25.4 (1.0) 57.2 (2.25) 215.9 (8.5) 1.17 (12.6) G-PRTH-35
(8.5 x 3.6 x 35’) (1 x 40)
228.6 x 88.9 x 11.9 25.4 x 1016
11.9 (39) 330.2 (13.0)  25.4 (1.0) 57.2 (2.25) 228.6 (9.0) 1.09 (11.7) G-PRTH-39
(9.0 x 3.5 x 39’) (1 x 40)
 Dimensions may vary—Consult your local sales representative for specifications.
 Shaft bottom [MM. Dia.(In. Dia)] x shaft top [MM. Dia. (In.Dia.)] x shaft length to tenon.
 Calculated for winds of 160 KPH/100 MPH.
 Anchor bolts and templates are preshipped upon request.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 709


© May 2016
Hinged Steel Poles

NEC/CEC:
Rated for Ordinary (Unclassified) Locations

Applications
• To mount single or multiple luminaires to heights from 6.1 to
9.1 m (20 to 35 ft). Hinged design allows easy servicing of 50.8 mm (2 in) Pipe Size Tenon
(60.5 mm (2-3/8 in))
luminaires at shoulder height. 101.6
(4.0)
Features
• Shafts are structural steel with a minimum yield strength of
46,000 psi.
• Heavy duty hinge assembly secures upper section to lower
POLES/HANGERS: NEC/CEC ORDINARY LOCATION ARCHITECTURAL

section with high strength 19.05 mm (3/4 in) Dia. bolt. A flexible
protective channel is provided to protect wires when pole is
lowered.
• Pole counter-balance is designed to offset weight of luminaires
and is made from steel with minimum yield strength of 36,000
psi.
• Base plates are of structural quality hot-rolled steel with
minimum yield strength of 36,000 psi.
• A 76.2 x 127 mm (3 in x 5 in) reinforced handhole with cover
and grounding lug 355.6 mm (14 in)above the pole base is
standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 50,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
355.6
Options (14.0)

• For bronze powder coat finish (to match Appleton fixtures) add
suffix -EPX. For galvanized finish add -GAL.
• An optional lowering winch is available and recommended for
easy one-man operation of hinged poles. (Only one lowering
winch per installation is required because winch assembly
mounts from pole to pole and dismounts for easy storage.) Accessory: GLW –
Lowering winch is furnished with mounting hardware, 7.62 m Lowering Device (Winch)
(25 ft) of 4.8 mm (3/16 in) galvanized wire rope and safety snap
hook.
Dimensions may vary. Consult your local sales representative for specifications
Mounting Shaft Size Bolt Base Max.
Height Mm.Sq. (in.Sq.) x Ga. Base Size Circle Thickness Bolt Proj. Anchor Bolt Proj Area Loading
m (ft) Mm. Sq (in. Sq) mm (in) Mm (in) Mm (in) Dia. x Lgth. Sq.M. (Sq. Weight Catalog
A F E S BC T P mm (in) Ft).  kg (lbs) Number 
6.1 6451.6 19.1 50.8 19.1 x 711.2 0.86 104.3 G-PHSM-20
2580.6 (4) x 7 2580.6 (4) x 11 
(20) (10.0) (0.75) (2.0) (.75 x 28) (9.3) (230)
6.1 7419.3 25.4 57.2 25.4 x 1016 1.4 158.8 G-PHSH-20
3225.8 (5)x 7 3225.8 (5) x 11 
(20) (11.5) (1.0) (2.25) (1.0 x 40) (15.2) (350)
7.32 6451.6 19.1 50.8 19.1 x 711.2 0.57 77.1 G-PHSM-24
2580.6 (4) x 7 2580.6 (4) x 11 
(24) (10.0) (0.75) (2.0) (.75 x 28) (6.1) (170)
7.32 7741.9 25.4 57.2 25.4 x 1016 1.33 127.0 G-PHSH-24
3871.0 (6) x 7 3871.0 (6) x 11 
(24) (12.0) (1.0) (2.25) (1.0 x 40) (14.3) (280)
9.14 6541.6 19.1 50.8 19.1 x 711.2 0.27 68.0 G-PHSM-30
2580.6 (4) x 7 2580.6 (4) x 11 
(30) (10.0) (0.75) (2.0) (.75 x 28) (2.9) (150)
9.14 7741.9 25.4 57.2 25.4 x 1016 1.00 108.9 G-PHSH-30
3871.0 (6) x 7 3871.0 (6) x 11 
(30) (12.0) (1.0) (2.25) (1.0 x 40) (10.8) (240)
10.67 7741.9 25.4 57.2 25.4 x 1016 0.33 81.6 G-PHSH-35
3871.0 (6) x 7 3871.0 (6) x 11 
(35) (12.0) (1.0) (2.25) (1.0 x 40) (3.6) (180)

 Dimensions may vary—Consult your local sales representative for specifications.


 Anchor bolts and templates are preshipped upon request. For accessory lowering winch, specify Cat. No. GLW.
 Calculated for winds of 100 MPH/160 KPH.

710 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Square Tapered Steel Poles

NEC/CEC:
Rated for Ordinary (Unclassified) Locations

Applications
• To mount single or multiple luminaires to heights from 6.1 to
11.9 m (20 to 39 ft).
Features 101.6
(4.0)
• 0.61 mm (2 in) pipe size tenon accepts a single luminaire or 2, 50.8 mm (2 in)
3, or 4 luminaires with appropriate pole-top mounting bracket. Pipe Size Tenon
(60.5 mm (2-3/8 in) O.D)
• High strength shafts have a uniform taper and are made from
11 gauge commercial quality hot rolled steel.

POLES/HANGERS: NEC/CEC ORDINARY LOCATION ARCHITECTURAL


• Base plates are of structural quality hot rolled steel with
minimum yield strength of 36,000 psi.
• A 76.2 x 127 mm (3 in x 5 in) reinforced handhole with cover
and grounding lug 355.6 mm (14 in) above the pole base is
standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL.

355.6
(14.0)

Dimensions may vary. Consult your local sales representative for specifications
Mounting Base
Height Shaft Size  Base Size Bolt Circle Thickness Bolt Proj. Anchor Bolt
m (ft) Sq.MM. x M mm (in) mm (in) mm (in) mm (in) Dia. x Lgth. Max. Proj Area Catalog
A (Sq.In. x Ft ) S BC T P In/mm Sq.M (Sq.Ft) Number 
6.1 3387 x 2097 x 6.1 266.7 25.4 57.2 25.4 x 1016.0 0.87
 G-PSTH-20
(20) (5.25 x 3.25 x 20’) (10.5) (1.0) (2.25) (1 x 40) (9.4)
7.3 4032 x 2484 x 12.2 330.2 25.4 57.2 25.4 x 1016.0 0.83
 G-PSTH-24
(24) (6.25 x 3.85 x 24’) (13.0) (1.0) (2.25) (1 x 40) (8.9)
9.1 4290 x 2097 x 9.1 304.8 25.4 57.2 25.4 x 1016.0 0.54
 G-PSTH-30
(30) (6.65 x 3.25 x 30’) (12.0) (1.0) (2.25) (1 x 40) (5.8)
10.7 4032 x 2097 x 10.7 330.2 25.4 57.2 25.4 x 1016.0 0.41
 G-PSTH-35
(35) (6.25 x 3.25 x 35’) (13.0) (1.0) (2.25) (1 x 40) (4.4)
11.9 4613 x 2097 x 11.9 330.2 25.4 63.5 25.4 x 1016.0 0.35
 G-PSTH-39
(39) (7.15 x 3.25 x 39’) (13.0) (1.0) (2.50) (1 x 40) (3.8)

 Shaft bottom [MM. Dia.(In. Dia)] x shaft top [MM. Dia.(In. Dia)] x shaft length to tenon.
 Dimensions may vary—Consult your local sales representative for specifications.
 Calculated for winds of 100 MPH.
 Anchor bolts and templates are preshipped upon request.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 711


© May 2016
Square Steel Poles

NEC/CEC:
Rated for Ordinary (Unclassified) Locations

Applications
• To mount single or multiple luminaires to heights from 4.3 to
9.1 m (14 to 30 ft).
Features 101.6
(4.0)
• 50.8 mm (2 in) pipe size tenon accepts a single luminaire, or 2, 50.8 mm (2 in) Pipe Size Tenon
(60.5 mm (2-3/8 in))
3, or 4 luminaires with appropriate pole-top mounting bracket.
• High strength shafts are made from square steel structural tube
with minimum yield strength of 46,000 psi.
POLES/HANGERS: NEC/CEC ORDINARY LOCATION ARCHITECTURAL

• Base plates are of structural quality hot-rolled steel with


minimum yield strength of 36,000 psi.
• A 76.2 x 127 mm (3 in x 5 in) reinforced handhole with cover
and grounding lug 355.6 mm (14 in) above the pole base is
standard.
• Anchor bolts are furnished complete with nuts and washers,
and are of 55,000 psi steel.
Standard Finishes
• Poles are finished with red-oxide prime-paint after fabrication
Options
• For bronze powder coat finish (to match Appleton fixtures) add
Suffix -EPX. For galvanized finish add suffix -GAL. 355.6
(14.0)

Dimensions may vary. Consult your local sales representative for specifications
Mounting Base
Height Base Size Bolt Circle Thickness Bolt Proj. Anchor Bolt
m (ft) Shaft Size  mm (in) mm (in) mm (in) in (mm) Dia. x Lgth. Max. Proj Area Catalog
A mm (in) S BC T P mm (in) Sq.M. (Sq.Ft.) Number 
4.3 101.6 x 101.6 x 11Ga. 203.2 19.1 50.8 19.1 x 508.0 1.01
 G-PSSM-14
(14) (4” x 4” x 11Ga.) (8.0) (0.75) (2.00) (0.75 x 20) (10.9)
4.3 101.6 x 101.6 x 11Ga. 203.2 19.1 50.8 19.1 x 508.0 1.34
 G-PSSH-14
(14) (4” x 4” x 7Ga.) (8.0) (0.75) (2.00) (0.75 x 20) (14.4)
5.2 101.6 x 101.6 x 11Ga. 203.2 19.1 50.8 19.1 x 508.0 0.64
 G-PSSM-17
(17) (4” x 4” x 11Ga.) (8.0) (0.75) (2.00) (0.75 x 20) (6.9)
5.2 101.6 x 101.6 x 7Ga. 203.2 19.1 50.8 19.1 x 508.0 1.11
 G-PSSH-17
(17) (4” x 4” x 7Ga.) (8.0) (0.75) (2.00) (0.75 x 20) (11.9)
6.1 101.6 x 101.6 x 7Ga. 203.2 19.1 50.8 19.1 x 508.0 0.94
 G-PSSM-20
(20) (4” x 4” x 7Ga.) (8.0) (0.75) (2.00) (0.75 x 20) (10.1)
6.1 127.0 x 127.0 x 7Ga. 279.4 25.4 57.2 25.4 x 1016 1.60
 G-PSSH-20
(20) (5” x 5” x 7Ga.) (11) (1.0) (2.25) (1 x 40) (17.2)
7.3 127.0 x 127.0 x 11Ga. 279.4 25.4 57.2 25.4 x 1016 1.11
 G-PSSM-24
(24) (5” x 5” x 7Ga.) (11) (1.0) (2.25) (1 x 40) (11.9)
7.3 152.4 x 152.4 x 7Ga. 304.8 25.4 57.2 25.4 x 1016 1.75
 G-PSSH-24
(24) (6” x 6” x 7Ga.) (12.0) (1.0) (2.25) (1 x 40) (18.8)
9.1 127.0 x 127.0 x 7Ga. 279.4 25.4 57.2 25.4 x 1016 0.64
 G-PSSM-30
(30) (5” x 5” x 7Ga.) (11) (1.0) (2.25) (1 x 40) (6.9)
9.1 152.4 x 152.4 x 7Ga. 304.8 25.4 57.2 25.4 x 1016 1.09
 G-PSSH-30
(30) (6” x 6” x 7Ga.) (12.0) (1.0) (2.25) (1 x 40) (11.7)

 Shaft bottom [MM. Dia.(In. Dia)] x shaft top [MM. Dia.(In. Dia)] x shaft length to tenon.
 Dimensions may vary—Consult your local sales representative for specifications.
 Calculated for winds of 100 MPH.
 Anchor bolts and templates are preshipped upon request.

712 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles

NEC/CEC:
Rated for Ordinary (Unclassified) Locations

Metal Pole Brackets

POLES/HANGERS: NEC/CEC ORDINARY LOCATION ARCHITECTURAL


Wood Pole Brackets

Visit our website at www.emerson.com or contact us at (800) 621-1506. 713


© May 2016
Floodlight Mounting Brackets
Single or Multiple Installation on Wall, Wood or Metal Poles

NEC/CEC:
Rated for Ordinary (Unclassified) Locations

Poletop Brackets for Metal Poles — Dimensions may vary. Consult your local sales representative for specifications
Floodlight mounting brackets for installation of 2 to 4 floodlights atop metal poles are manufactured from high-strength steel tube, and
slip-fit onto 50.8 mm (2 in) pipe size poletop tenons. Furnished with 3 locking setscrews and red oxide prime coat finish. Bracket tenon is
50.8 mm (2 in) pipe size (60.5 mm 2-3/8 in) O.D.).
Dimensions mm (in) Description Catalog Number

431.8 431.8
(17.0) (17.0)
POLES/HANGERS: NEC/CEC ORDINARY LOCATION ARCHITECTURAL

254.0
(10.0)
Poletop Bracket for Two Luminaires G-PB-2
25.4 (1.0)
127.0
(5.0) Slip-Fitter for 50.8 mm (2 in)
(3) 9.7 mm (3/8 in) x 16.0 mm Std. Pipe
(5/8 in) Setscrews at 120 °

431.8 431.8
(17.0) (17.0)

50.8 mm 508.0
(2.0 in) (20.0)
Std. Pipe
254.0 Poletop Bracket for Three Luminaires G-PB-3
(10.0)

25.4 (1.0) mm
127.0
(5.0) Slip-Fitter for 50.8 mm (2 in)
(3) 9.7 mm (3/8 in) x 16.0 mm Std. Pipe
(5/8 in) Setscrews at 120 °

Poletop Bracket for Three Luminaires (120° apart) G-PB-3-120


431.8
(17.0) R.

762.0 762.0 762.0


(30.0) (30.0) (30.0)
28.7 mm 50.8 mm
(1-1/8 in) (2.0 in)
254.0 Dia. Hole for
(10.0) wiring Std. Pipe
Poletop Bracket for Four Luminaires (in line) G-PB-14
25.4 (1.0)
127.0
(5.0)
Slip-Fitter for 50.8 mm (2 in)
(3) 9.7 mm (3/8 in) x 16.0 mm Std. Pipe
(5/8 in) Setscrews at 120 °

863.6

431.8 50.8 mm
(34.0)
Poletop Bracket for Four Luminaires G-PB-4
(2.0 in) Removable
(17.0) R Cap
254.0 (10.0) Std. Pipe

127.0 12.7 (0.5)


(5.0)

Slip-Fitter for 50.8 mm (3) 9.7 mm (3/8 in) x 16.0 mm


(2 in) Std. Pipe (5/8 in) Setscrews at 120 °

714 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Applications
• Typical applications include:
— Pulp and paper mills
— Processing plants
— Chemical plants
— Oil refineries
— Foundries
— Food processing plants
— Storage areas
— Waste and sewage treatment
— Parking garages
— Other areas where water, dirt and rough usage are a problem
Features
• Compact in size, attractively styled contemporary design,
rugged and dependable.
• Easy to install and service.
• One-piece housing.
• One-piece lens in hinged cover. Secured by four M6 captive Floodlight
stainless steel slotted hex-head bolts.
• Thermal shock- and impact-resistant glass lens standard.
• Diffused polycarbonate lens available as an option.
• Heavy duty, high temperature silicone rubber gasket,
mechanically secured.
• Universal design for flood and high bay mounting.
• Floodlight Mounting:

LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED


— Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish.
• High Bay Mounting:
— (1) Conduit entry on back of luminaire with locking set screw.
— Rotate yoke up or remove.
• Chain Mounting: High Bay
— Mounts via eyebolts threaded into the corners of the fixture.
— Available with chain mounting, or as an accessory.
— Rotate yoke up or remove.
• Cool operating temperatures translate into long luminaire life.
• NEC/CEC versions available with a total of three (3) 3/4" NPT
entries with integral bushings.
• ATEX/IECEx version provided with one (1) 3/4" NPT/M20
adapter and two (2) close up plugs.
• Two (2) 3/4" NPT aluminum close up plugs provided.
• Electrical:
— NEC/CEC/ATEX/IECEx: 120-277 Vac, 50/60 Hz
— NEC/CEC: 347-480 Vac, 50/60 Hz.; 250 Vdc available on
AMLED77YBC.
• Terminal block (screw type for secure connection) can accept
UL/CSA 24-10AWG and IEC 0.2 - 4 mm2.
Standard Materials
• Housing and lens door: copperfree (4/10 of 1% max.) aluminum
• Gasket: silicone rubber
• Reflector: metallized high reflectance finish
• Yoke mount: zinc plated steel
• Bolts: stainless steel
• Close up plugs: (2) aluminum provided
Standard Finishes
• Housing, lens cover and yoke mount: architectural bronze
polyester

Visit our website at www.emerson.com or contact us at (800) 621-1506. 135


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent
NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:
Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

NEC/CEC Certifications and Compliances


• UL Standard: UL 1598, UL 1598A, UL 8750, UL 844 30°
• CSA Standard: C22.2 No. 250.0, C22.2 No. 137
• cCASus Certified: 065182
• Ambient Temperature: AMLED67 and AMLED77 -40 °C to
+65 °C (-40 °F to +149 °F); AMLED87 -40 °C to +55 °C
(-40 °F to +131 °F)
• The Class II, Division 1 & 2, Class III & Simultaneous Exposure
Restrictions: 30° Rotation Maximum
— The luminaire may be rotated a maximum of 30 degrees from
the vertical plane such that the lens will be facing down (see
30° rotation picture).
— The luminaire must not be rotated such that the lens will be
facing up at any angle. Also, for fixtures with glass lens only
and not for chain-mounted or pendant-mounted fixtures.
ATEX/IECEx Certifications and Compliances
• Certification Type AMLED
— Gas: Zone 2
- Conforming to ATEX 94/9/EC: II 3 G
- Protection Level: EPL Gc
- Type of Protection: Ex nA IIC
- Temperature class: See Table on following page
— Dust: Zones 21 and 22
- Conforming to ATEX 94/9/EC: II 2 D and II 3D
- Protection Level: EPL Db and Dc 30° Rotation
LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED

- Type of Protection: Ex tb IIIC and Ex tc IIIC


- Temperature class: See Table on following page
• EC Declaration of Conformity: 50307
• ATEX Certificate: LCIE 14 ATEX 1016X (Zone 2/22), LCIE 14
ATEX 3049X (Zone 21)
• IECEx Certificate: IECEx LCIE 14.0030X
• Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F)
• Index of Protection according EN/IEC 60529: IP66
• Impact Resistance (shock): IK08
EURASEC Certification
• EURASEC N° TC RU C-FR.ГБ05.B.00912
DesignLights™ Consortium (for the following models)
• AMLED67YBU1
• AMLED67YBU1D
• AMLED77YBU1
• AMLED77YBU1D
• AMLED87YBU1
• AMLED87YBU1D

136 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide — NEC/CEC and ATEX/IECEx Certified Areamaster LED
AMLED 7 Y BU1 FN

Series: Mounting: Options:


AMLED: Areamaster LED Series Y - Yoke Mount FN - Fuse for BU1 or
NEC/CEC and ATEX/IECEx C - Chain Mount BH Voltages 
Certified D - Diffused Polycarbonate Lens 
DG - Diffused Glass Lens 

HID Light Level Equivalent: Voltage:


67 - 250 Watt BU1 - 120-277 Vac, 50/60 Hz
77 - 400 Watt BH - 347-480 Vac, 50/60 Hz 
87 - 750 Watt BC - 250 Vdc 

LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED

 Not available for use on the 750 Watt equivalent.


 Not available for use on the ATEX/IECEx certified fixtures.
 Canadian Electrical Code does NOT allow fusing in hazardous locations. Fuse not CEC rated.
 Not available for use on the 250 and 750 Watt equivalent.
 For ATEX/IECEx versions.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 137


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Technical Data — NEC/CEC


Lamp Gas Dust
Ambient Supply Wire Class II,
Temperature Temperature Class I, ExnA IIC Division 1 Catalog
Line Voltage Type °C (°F) °C (°F) Division 2  Groups AExnA IIC Groups E,F,G Number
40 (104) 75 (167) T4 A,B,C,D T4 T6
120-277 Vac LED 55 (131) 90 (194) T3C A,B,C,D T3 T6 AMLED67YBU1
65 (149) 90 (194) T3C A,B,C,D T3 T5
40 (104) 75 (167) T4 A,B,C,D — T6
347-480 Vac LED AMLED67YBH
55 (131) 75 (167) T3C A,B,C,D — —
40 (104) 75 (167) T4 A,B,C,D T4 T6
120-277 Vac LED 55 (131) 90 (194) T3C A,B,C,D T3 T5 AMLED77YBU1
65 (149) 105 (221) T3C A,B,C,D T3 T4A
347-480 Vac LED 40 (104) 75 (167) T4 A,B,C,D — T6 AMLED77YBH
250 Vdc LED 40 (104) 75 (167) T4A A,B,C,D T4 T5 AMLED77YBC
40 (104) 75 (167) T3C A,B,C,D T3 T4A
120-277 Vac LED AMLED87YBU1
55 (131) 90 (194) T3A A,B,C,D T3 T5
347-480 Vac LED 40 (104) 75 (167) T3 A,B,C,D — T5 AMLED87YBH
LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED

Technical Data — ATEX/IECEx – Ambient Temperature Ta °C (°F)


GAS (Zone 2)  DUST (Zones 21-22) 
40 (104) 55 (131) 40 (104) 55 (131) 40 (104) 55 (131) 40 (104) 55 (131) 40 (104) 55 (131) 40 (104) 55 (131)
Catalog
Downward Wall Mounting Upward Downward Wall Mounting Upward Number

T4 T4 T4 T4 T4 T3 68 83 67 82 70 85
AMLED67YBU1
114 (237) 129 (264) 109 (228) 124 (255) 117 (243) 132 (270) (154) (181) (153) (180) (158) (185)

T3 T3 T3 T3 T3 T3 75 90 74 89 77 92
AMLED77YBU1
144 (291) 159 (318) 146 (295) 161 (322) 150 (302) 165 (329) (167) (194) (165) (192 ) (171) (198)

T3 T3 T3 T3 T3 T2 83 98 82 97 87 102
AMLED87YBU1
178 (352) 193 (379) 176 (349) 191 (376) 183 (361) 198 (388) (181) (208) (180) (207) (198) (216)

“T” Numbers Represent the Maximum Internal Temperature  or Maximum Surface Temperature 
NEC/CEC
“T” # T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6
Temp. 351- 326- 301- 281- 261- 231- 216- 201- 181- 166- 161- 136- 121- 101- 86-
85
450 350 325 300 280 260 230 215 200 180 165 160 135 120 100
Range
(664- (619- (574- (538- (502- (448- (421- (394- (358- (331- (322- (277- (250- (214- (187-
ºC (˚ºF) (185)
842) 662) 617) 572) 536) 500) 446) 419) 392) 356) 329) 320) 275) 248) 212)
ATEX/IECEx
“T” # T1 T2 T3 T4 T5 T6
Temp. 86-
301-450 201-300 136-200 101-135 85
100
Range
(187-
ºC (˚ºF) (547-842) (394-572) (277-392) (214-275) (185)
212)

 T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC and ATEX/IECEx.
 T numbers represent the maximum surface temperature under a dust blanket for Class II, Division 1 and 2 as designated by the NEC or Zone 2 (Gas) and 22
(Dust) locations as designated by the IEC.

138 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Electrical Specifications — Flood Mount

Watts Total
Input Power Input Amps Harmonic Color Temp
Voltage Range Frequency ( Hz) (Nom.) (Max.) Distortion Power Factor CRI CCT Catalog Number

120-277 Vac 50/60 86/85 0.72 - 0.35 0.5 > 0.98 70 5650K AMLED67YBU1

347-480 Vac 50/60 88/90 0.27 - 0.22 0.5 > 0.95 70 5650K AMLED67YBH

120-277 Vac 50/60 125/121 1.10 - 0.47 0.5 > 0.98 70 5650K AMLED77YBU1

347-480 Vac 50/60 124/125 0.37 - 0.29 0.5 > 0.95 70 5650K AMLED77YBH

250 Vdc — 118 0.47 0.5 > 0.98 70 5650K AMLED77YBC

120-277 Vac 50/60 174/169 1.60 - 0.70 0.5 > 0.98 70 5700K AMLED87YBU1

347-480 Vac 50/60 176/175 0.52 - 0.39 0.5 > 0.95 70 5700K AMLED87YBH

LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED


Line Voltage
Catalog Number
NEC/CEC ATEX/IECEx

120-277 Vac, 50/60 Hz AMLED67YBU1 AMLED67YBU1

120-277 Vac, 50/60 Hz AMLED77YBU1 AMLED77YBU1

120-277 Vac, 50/60 Hz AMLED87YBU1 AMLED87YBU1

347-480 Vac, 50/60 Hz AMLED67YBH —

347-480 Vac, 50/60 Hz AMLED77YBH —

250 Vdc AMLED77YBC —

347-480 Vac, 50/60 Hz AMLED87YBH —

Visit our website at www.emerson.com or contact us at (800) 621-1506. 139


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Accessories and Replacement Parts

Catalog Number
Description NEC/CEC, ATEX/IECEx
Crossarm Mounting Bracket
Has 180° horizontal adjustment — degree marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
G-AM-8-CA
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.
Pipe or Wall Mount Bracket
Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,
or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
G-AM-8-WB
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.
Poletop Slip-Fitter
Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
G-SF20
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
Slip-fits 1" or 1-1/2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
AMLEDSF1
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.
Poletop Slip-Fitter
LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED

Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking


bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with G-AM-8-SF
architectural bronze polyester finish.

Chain
Chain mount assembly comes with two (2) 914.4 mm (36 inch) long chains,
four (4) eye bolts, four (4) hex bolts, four (4) lock washers, four (4) hex nuts,
eight (8) plain washers and an instruction sheet for complete assembly and AMLEDCM
mounting. Chains are galvanized steel, eye bolts are zinc plated steel, all other
hardware is stainless steel.

Catalog Number
Description NEC/CEC ATEX/IECEx
LED Array
With White LED's for the AMLED67 AMLED67AW AMLED67AW
With White LED's for the AMLED77 AMLED77AW AMLED77AW
With White LED's for the AMLED87 AMLED87AW AMLED87AW
Drivers
120 - 277 Vac — BU Version and BC Version AMLED77DBU —
120 - 277 Vac — BU1 Version — AMLED87: Left Side — AMLED67, AMLED77 AMLEDDBU1L AMLEDDBU1L
120 - 277 Vac — BU1 Version — AMLED87: Right Side AMLEDDBU1R AMLEDDBU1R
347 - 480 Vac — BH Version — AMLED67, AMLED77 AMLED77DBH —
347 - 480 Vac — BH Version — AMLED87: Left Side AMLED87DBHL —
347 - 480 Vac — BH Version — AMLED87: Right Side AMLED87DBHR —
Door Assembly
With a Glass Lens, Pins AMLEDMDOOR AMLEDMDOOR
With a Polycarbonate Lens, Pins AMLEDMDOORP —

140 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Dimensions in Millimeters (Inches)


Floodlight
388.6 mm (15.30 in)
182.9 mm 93.9 mm (3.70 in)
(7.20 in) 1/4-20 U.N.C.
(4) corner

182.9 mm
(7.20 in)
358.1 mm Conduit
(14.10 in) Entry 391.2 mm
(Pendant (15.40 in)
Mount)

Set
Screw 144.78 mm
(5.70 in)

(3) hubs for 3/4"


57.2 mm Yoke NPT Conduit 
(4) Yoke Bolts (2.25 in) 3/4" to M20
122.7 mm reducer bushing
Conduit 3.64 Turning Radius (4.83 in) 88.9 mm
(3.50 in)
Entry 180° Rotation
44.45 mm (3) Mounting Holes
(1.75") Ø 14 mm (0.56 in)
88.9 mm (3.50 in)

LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED


High Bay Pendant Mount

Ceiling
Rotate Yoke Up
Recommended Minimum Juction Box or Remove
Mounting Distance Set Screw
304.8 mm (12 in)

152.4 mm
(6 in)

 3/4" NPT/M20 adapter supplied for ATEX version.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 141


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Photometric Data — DATA SHOWN IS ABSOLUTE

REPORT NUMBER: AMLED67YBU1_FLOOD


Lamps: Areamaster, High Bay Mount, LED Board 39 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear
Luminaire Lumens 8238

POLAR CANDELA DISTRIBUTION ISOCANDELA CURVES Zonal Lumen and Percentage at 25 °C (77 °F)
3
Zone Lumens % Lamp % Fixture
0-10 245.6 N.A. 3.0
90˚
10-20 771.8 N.A. 9.4
2
0.1 fc
20-30 1431 N.A. 17.4
0.5 fc
30-40 1842 N.A. 22.4
75˚
1 40-50 1785 N.A. 21.7
1250
2.5 fc 50-60 1448 N.A. 17.6
60-70 667.1 N.A. 8.1
60˚ 0
70-80 43.8 N.A. 0.5
80-90 4.5 N.A. 0.1
1 fc 1
2500

45˚
0.2 fc
2696
2

3750
3
0 1 2
0˚ 15˚ 30˚
Distance in units of mount height (25 ft)
LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED

REPORT NUMBER: AMLED67YBU1_HIGHBAY


Lamps: Areamaster, High Bay Mount, LED Board 39 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear

POLAR CANDELA DISTRIBUTION Zonal Lumen Summary and Percentage at 25 °C (77 °F)
Zone Lumens % Lamp % Fixture
0-30 2434 N.A. 29.2
0-40 4283 N.A. 51.6
0-60 7553 N.A. 90.6
90˚
60-90 780 N.A. 9.4
0-90 8333 N.A. 100.0
75˚ 90-180 0 N.A. 0
0-180 8333 N.A. 100.0
1250

60˚ Zonal Lumen and Percentage at 25 °C (77 °F)


Zone Lumens % Lamp % Fixture
0-10 244.8 N.A. 2.9
2500
10-20 764.2 N.A. 9.2
45˚
2696
20-30 1425 N.A. 17.1
30-40 1849 N.A. 22.2
40-50 1787 N.A. 21.4
3750
50-60 1483 N.A. 17.8
0˚ 15˚ 30˚
60-70 731.0 N.A. 8.8
70-80 46.7 N.A. 0.6
80-90 2.4 N.A. 0.0

142 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Areamaster™ LED Flood/High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Photometric Data — DATA SHOWN IS ABSOLUTE

REPORT NUMBER: AMLED77YBU1_FLOOD


Lamps: Areamaster, High Bay Mount, LED Board 56 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear
Characteristics: Maximum Candela: 5818; Maximum Candela Angle: 22.5 H 25.5 V; Horizontal Beam Angle (50%): 97.0; Vertical Beam Angle (50%): 102; Horizontal Field
Angle (10%): 134; Vertical Field Angle (10%): 134; Beam Lumens 10414; Field Lumens 12967; Luminaire Lumens 13157

AXIAL CANDELA AXIAL CANDELA DISPLAY ISOCANDELA CURVES


DEG. HOR. VERT.
90.0 0 0
85.0 21 2
75.0 26 5 90
65.0 700 733
55.0 2400 2341 581.8
47.5 3023 2976 60

42.5 3375 3307 2909


37.5 3838 3826
30
33.0 4312 4319
29.0 4670 4719 1250

Vertical Angles
25.5 4964 4898 0
22.5 4910 4857
19.5 4700 4660
17.0 4456 4343 2500 -30
15.0 4273 4249
13.0 4184 4165
11.0 4154 4123 -60

LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED


9.0 4139 4105 3750
7.0 4124 4119
-90
5.0 4127 4133 0 30 60 90
Horizontal Angles
3.0 4138 4150
1.0 4149 4153
0.0 4149 4149

CIE Type – Direct


REPORT NUMBER: AMLED77YBU1_HIGHBAY
Spacing
Plane Lamps: Areamaster, High Bay Mount, LED Board 56 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered
Criteria
0 Deg 1.5
To 3-1/2 X 3-1/2, Lens Clear
90 Deg 1.5 Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
Zone Lumens % Ceiling Rcc 80 70 50 30 10 0
0-5 98 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
90˚
5-10 290 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
10-15 485 1 111 107 103 100 108 105 102 99 101 98 96 97 95 93 93 92 90 88
15-20 711 75˚ 2 102 95 89 84 99 93 88 83 90 85 81 86 83 79 83 80 78 76
20-25 993 3 94 84 77 71 91 83 76 70 80 74 69 77 72 68 75 70 67 65
1250
25-30 1264 4 86 75 67 61 84 74 66 60 71 65 59 69 63 59 67 62 58 56
30-35 1440 60˚
5 79 67 59 52 77 66 58 52 64 57 52 62 56 51 60 55 50 48
35-40 1517 6 73 60 52 46 71 59 51 45 58 50 45 56 50 45 54 49 44 42
40-45 1471 7 67 54 46 40 66 54 46 40 52 45 40 51 44 39 49 44 39 37
2500
45-50 1392 8 63 50 41 36 61 49 41 36 48 40 35 46 40 35 45 39 35 33
45˚
50-55 1283 9 58 45 37 32 57 45 37 32 44 37 32 43 36 31 42 36 31 30
55-60 1086 10 55 42 34 29 53 41 34 29 40 33 29 39 33 28 38 32 28 27
60-65 764
3750
65-70 340 Zonal Lumen Summary
0˚ 15˚ 30˚
70-75 37 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
75-80 4 0-30 3841 N.A. 29.1 90-130 2 N.A. 0.0
80-85 2 0-40 6798 N.A. 51.5 90-150 6 N.A. 0.0
85-90 1 0-60 12029 N.A. 91.1 90-180 7 N.A. 0.1
0-90 13177 N.A. 99.8 0-180 13199 N.A. 100
90-120 1 N.A. 0.0

Visit our website at www.emerson.com or contact us at (800) 621-1506. 143


© May 2016
Areamaster™ LED High Bay Luminaires
For Hazardous Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC: NEC/CEC: NEC: ATEX/IECEx: ATEX/IECEx:


Class I, Division 2, Groups A, Class II Division 2, Groups F, G Marine Outside Type Zones 2 and 22 Zone 21
B, C, D Class III (Salt Water) II 3 GD II 2 D
Class I, Zone 2 Group IIC Simultaneous Exposure Wet Locations EPL Gc and Dc EPL Db
Class II, Division 1, Groups Type 3R, 4, 4X Ex nA IIC; Ex tc IIIC Ex tb IIIC
E, F, G IP66/67 IP66, IK08 IK08

Photometric Data — DATA SHOWN IS ABSOLUTE

REPORT NUMBER: AMLED87YBU1_FLOOD


Lamps: Areamaster, Pendent Mount, LED Board 20 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear
Characteristics: NEMA Type: 7Hx7V; Maximum Candela: 8092; Maximum Candela Angle: 25.5H 25.5V; Horizontal Beam Angle (50%): 97.3; Vertical Beam Angle (50%):
103; Horizontal Field Angle (10%): 137; Vertical Field Angle (10%): 136; Beam Lumens 14933; Field Lumens 18585; Luminaire Lumens 18842

AXIAL CANDELA AXIAL CANDELA DISPLAY ISOCANDELA CURVES


DEG. HOR. VERT.
90 0 0
85 31 5
75 36 8 90

65 1239 938
55 3463 3477 581.8
60
47.5 4393 4345
42.5 4921 4831 2909

37.5 5955 5752 30


33 6455 6392
2023

Vertical Angles
29 6656 6778
25.5 6998 7087 0

22.5 7109 7158 4046


19.5 6665 6664
-30
17 6302 6222
15 6059 6108
6069
13 6027 6044 -60
11 5931 5942
LED/FLOODLIGHTS: NEC/CEC, ATEX/IECEx ENCLOSED AND GASKETED

9 5914 5938
7 5933 5956 8092 -90
0 30 60 90
5 5974 5975 Horizontal Angles

3 6003 5995
1 6002 6004
0 5999 5999

CIE Type – Direct


REPORT NUMBER: AMLED87YBU1_HIGHBAY
Spacing
Plane Lamps: Areamaster, High Bay Mount, LED Board 20 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered
Criteria
0-180 1.54
To 3-1/2 X 3-1/2, Lens Clear
90-270 1.54
Coefficients of Utilization - Zonal Cavity Method
Zone Lumens Effective Floor Cavity Reflectance 0.20
0- 5 141 % Ceiling Rcc 80 70 50 30 10 0
5- 10 419 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
90˚
10- 15 697 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
15- 20 1004 1 111 107 103 100 108 105 101 99 100 98 95 97 95 93 93 91 90 88
20- 25 1408 75˚ 2 102 95 89 84 99 93 88 83 89 85 81 86 83 79 83 80 77 75
25- 30 1794 3 93 84 77 71 91 82 76 70 80 74 69 77 72 68 74 70 67 65
2500
30- 35 2079 4 86 75 67 60 84 73 66 60 71 64 59 69 63 58 67 62 58 56
35- 40 2151 60˚
5 79 67 58 52 77 66 58 52 64 57 51 62 56 51 60 55 50 48
40- 45 2143 6 73 60 52 45 71 59 51 45 57 50 45 56 49 45 54 49 44 42
45- 50 2011 7 67 54 46 40 66 54 46 40 52 45 40 51 44 39 49 43 39 37
5000
50- 55 1834 8 63 49 41 36 61 49 41 35 47 40 35 46 40 35 45 39 35 33
45˚
55- 60 1567 9 58 45 37 32 57 45 37 32 43 36 31 42 36 31 41 35 31 29
60- 65 1118 10 54 42 34 29 53 41 34 29 40 33 28 39 33 28 38 32 28 26
65- 70 514 7500
70- 75 62 Zonal Lumen Summary
0˚ 15˚ 30˚
75- 80 3 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
80- 85 2 0-30 5462 N.A. 28.8 90-130 3 N.A. 0
85- 90 1 0-40 9692 N.A. 51.2 90-150 5 N.A. 0
0-60 17247 N.A. 91.1 90-180 7 N.A. 0
0-90 18946 N.A. 100.1 0-180 18933 N.A. 100
90-120 2 N.A. 0

144 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Industrial Areamaster™ LED Flood/High Bay Luminaires
For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC:
Type 3R, 4X
IP66, IP67
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)

Applications
• Powerful, efficient weatherproof lighting for applications
such as:
— Security lighting
— Production facilities
— Warehouses

LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION


— Processing plants
— Storage areas
— Parking garages and lots
Features
• Compact in size, attractively styled contemporary design, Floodlight
rugged and dependable.
• Easy to install and service.
• One-piece housing.
• One-piece lens in hinged cover. Secured by four M6 captive
stainless steel slotted hex-head bolts.
• Thermal shock- and impact-resistant glass lens standard.
• Diffused polycarbonate lens available as an option.
• Heavy duty, high temperature silicone rubber gasket,
mechanically secured.
• Universal design for flood and high bay mounting. High Bay
• Floodlight Mounting:
— Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish.
• High Bay Mounting: NEC/CEC Certifications and Compliances
— (1) Conduit entry on back of luminaire with locking set screw.
• UL Standard: UL 1598, UL 1598A,
— Rotate yoke up or remove.
• CSA Standards: C22.2 No. 250.0
• Chain Mounting:
• cCSAus Certified: 164460
— Mounts via eyebolts threaded into the corners of the fixture.
— Available with chain mounting, or as an accessory. DesignLights™ Consortium (for the following models)
— Rotate yoke up or remove. • IAMLED67YBU1
• Cool operating temperatures translate into long luminaire life. • IAMLED67YBU1D
• Available with a total of three (3) 3/4" NPT entries with integral • IAMLED77YBU1
bushings. • IAMLED77YBU1D
• Two (2) 3/4" NPT aluminum close up plugs provided. • IAMLED87YBU1
• Electrical: • IAMLED87YBU1D
— NEC/CEC: 120-277 Vac, 50/60 Hz; 347-480 Vac, 50/60 Hz.;
250 Vdc available on AMLED77YBC.
• Terminal block (screw type for secure connection) can accept
UL/CSA 24-10AWG and IEC 0.2 - 4 mm2.
Standard Materials
• Housing and lens door: copperfree (4/10 of 1% max.) aluminum
• Gasket: silicone rubber
• Reflector: metallized high reflectance finish
• Yoke mount: zinc plated steel
• Bolts: stainless steel
• Close up plugs: (2) aluminum provided
Standard Finishes
• Housing, lens cover and yoke mount: architectural bronze
polyester

Visit our website at www.emerson.com or contact us at (800) 621-1506. 145


© May 2016
Industrial Areamaster™ LED Flood/High Bay Luminaires
For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC:
Type 3R, 4X
IP66, IP67
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide — Industrial Areamaster LED
IAMLED 7 7 Y BU1 FN

Series: Light Pattern Voltage:


LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION

IAMLED: Industrial Areamaster BU1 - 120-277 Vac,


LED Series 50/60 Hz
BH - 347-480 Vac,
50/60 Hz 
BC - 250 Vdc 
HID Light Level Equivalent: Mounting: Options:
6 - 250 Watt Y - Yoke Mount FN - Fuse for BU1 or
7 - 400 Watt C - Chain Mount BH Voltages 
8 - 750 Watt D - Diffused
Polycarbonate
Lens

Electrical Specifications — Flood Mount

Watts
Input Power Input Amps Total Harmonic
Catalog Number Voltage Range Frequency ( Hz) (Nom.) (Max.) Distortion Power Factor

IAMLED67YBU1 120-277 Vac 50/60 86/85 0.72 - 0.32 0.5 > 0.98

IAMLED67YBH 347-480 Vac 50/60 88/90 0.25 - 0.19 0.5 > 0.96

IAMLED77YBU1 120-277 Vac 50/60 125/121 1.10 - .047 0.5 > 0.98

IAMLED77YBH 347-480 Vac 50/60 124/125 0.35 - 0.25 0.5 > 0.96

IAMLED77YBC 250 Vdc — 118 0.47 0.5 > 0.98

IAMLED87YBU1 120-277 Vac 50/60 176/175 1.60 - 0.70 0.5 > 0.98

Line Voltage Catalog Number

120-277 Vac, 50/60 Hz IAMLED67YBU1

120-277 Vac, 50/60 Hz IAMLED77YBU1

120-277 Vac, 50/60 Hz IAMLED87YBU1

347-480 Vac, 50/60 Hz IAMLED67YBH

347-480 Vac, 50/60 Hz IAMLED77YBH

250 Vdc IAMLED77YBC

 Not available for use on the 750 Watt equivalent.


 Not available for use on the 250 and 750 Watt equivalent.

146 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Industrial Areamaster™ LED Flood/High Bay Luminaires
For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC:
Type 3R, 4X
IP66, IP67
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)

Accessories and Replacement Parts

Description Catalog Number


Crossarm Mounting Bracket

Has 180° horizontal adjustment — degree marked. Facilitates mounting floodlight to

LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION


crossarm or other flat surface, or to G-AM-8-WB. Includes floodlight yoke bolts. Malleable G-AM-8-CA
iron, zinc plated, chromate sealed, architectural bronze polyester finish.

Pipe or Wall Mount Bracket

Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal, or mounts on


flat surfaces. Includes U-bolt and crossarm bracket bolts. Malleable iron, zinc plated, G-AM-8-WB
chromate sealed, with architectural bronze polyster finish.

Poletop Slip-Fitter

Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts, 3 locking
bolts, and cord grip. Body is malleable iron-zinc plated, chromate sealed, with cast G-SF20
aluminum cap. Assembly has architectural bronze polyester finish.

Slip-fits 1" or 1-1/2” pipe size poletop tenons. Includes floodlight yoke bolts, 3 locking
bolts, and cord grip. Body is malleable iron-zinc plated, chromate sealed, with cast AMLEDSF1
aluminum cap. Assembly has architectural bronze polyester finish.

Poletop Slip-Fitter

Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking bolts, and
cord grip. Malleable iron, zinc plated, chromate sealed, with architectural bronze polyester G-AM-8-SF
finish.

Chain

Chain mount assembly comes with two (2) 914.4 mm (36 inch) long chains, four (4) eye
bolts, four (4) hex bolts, four (4) lock washers, four (4) hex nuts, eight (8) plain washers and
AMLEDCM
an instruction sheet for complete assembly and mounting. Chains are galvanized steel,
eye bolts are zinc plated steel, all other hardware is stainless steel.

LED Array
LED Array with White LED's for the IAMLED67 IAMLED67AW
LED Array with White LED's for the IAMLED77 IAMLED77AW
LED Array with White LED's for the IAMLED87 IAMLED87AW
Drivers
120 - 277 Vac Driver — BU1 Version — IAMLED87: Left Side —IAMLED67, IAMLED77 IAMLEDDBU1L
120 - 277 Vac Driver — BU1 Version — IAMLED87: Right Side IAMLEDDBU1R
347 - 480 Vac Driver — BH Version IAMLED77DBH
250 Vdc Driver — BC Version IAMLED77DBU
Door Assembly
Door Assembly with a Glass Lens, Pins IAMLEDMDOOR
Door Assembly with a Polycarbonate Lens, Pins IAMLEDMDOORP

Visit our website at www.emerson.com or contact us at (800) 621-1506. 147


© May 2016
Industrial Areamaster™ LED Flood/High Bay Luminaires
For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC:
Type 3R, 4X
IP66, IP67
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)

Dimensions in Millimeters (Inches)


Floodlight
388.6 mm (15.30 in)
182.9 mm 93.9 mm (3.70 in)
(7.20 in) 1/4-20 U.N.C.
(4) corner
LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION

182.9 mm
(7.20 in)
358.1 mm Conduit
(14.10 in) Entry 391.2 mm
(Pendant (15.40 in)
Mount)

Set
Screw 144.78 mm
(5.70 in)

(3) hubs for 3/4"


57.2 mm Yoke NPT Conduit 
(4) Yoke Bolts (2.25 in) 3/4" to M20
122.7 mm reducer bushing
Conduit 3.64 Turning Radius (4.83 in) 88.9 mm
(3.50 in)
Entry 180° Rotation
44.45 mm (3) Mounting Holes
(1.75") Ø 14 mm (0.56 in)
88.9 mm (3.50 in)

High Bay Pendant Mount

Ceiling
Rotate Yoke Up
Recommended Minimum Juction Box or Remove
Mounting Distance Set Screw
304.8 mm (12 in)

152.4 mm
(6 in)

148 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Industrial Areamaster™ LED Flood/High Bay Luminaires
For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC:
Type 3R, 4X
IP66, IP67
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)

Photometric Data — DATA SHOWN IS ABSOLUTE

REPORT NUMBER: IAMLED67YBU1_FLOOD


Lamps: Areamaster, High Bay Mount, LED Board 39 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear
Luminaire Lumens 8238

LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION


POLAR CANDELA DISTRIBUTION ISOCANDELA CURVES Zonal Lumen and Percentage at 25 °C (77 °F)
3
Zone Lumens % Lamp % Fixture
0-10 245.6 N.A. 3.0
90˚
10-20 771.8 N.A. 9.4
2
0.1 fc
20-30 1431 N.A. 17.4
0.5 fc
30-40 1842 N.A. 22.4
75˚
1 40-50 1785 N.A. 21.7
1250
2.5 fc 50-60 1448 N.A. 17.6
60-70 667.1 N.A. 8.1
60˚ 0
70-80 43.8 N.A. 0.5
80-90 4.5 N.A. 0.1
1 fc 1
2500

45˚
0.2 fc
2696
2

3750
3
0 1 2
0˚ 15˚ 30˚
Distance in units of mount height (25 ft)

REPORT NUMBER: IAMLED67YBU1_HIGHBAY


Lamps: Areamaster, High Bay Mount, LED Board 39 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear

POLAR CANDELA DISTRIBUTION Zonal Lumen Summary and Percentage at 25 °C (77 °F)
Zone Lumens % Lamp % Fixture
0-30 2434 N.A. 29.2
0-40 4283 N.A. 51.6
0-60 7553 N.A. 90.6
90˚ 60-90 780 N.A. 9.4
0-90 8333 N.A. 100.0
75˚ 90-180 0 N.A. 0
0-180 8333 N.A. 100.0
1250

60˚ Zonal Lumen and Percentage at 25 °C (77 °F)


Zone Lumens % Lamp % Fixture
0-10 244.8 N.A. 2.9
2500
10-20 764.2 N.A. 9.2
45˚
2696 20-30 1425 N.A. 17.1
30-40 1849 N.A. 22.2
3750
40-50 1787 N.A. 21.4
50-60 1483 N.A. 17.8
0˚ 15˚ 30˚
60-70 731.0 N.A. 8.8
70-80 46.7 N.A. 0.6
80-90 2.4 N.A. 0.0

Visit our website at www.emerson.com or contact us at (800) 621-1506. 149


© May 2016
Industrial Areamaster™ LED Flood/High Bay Luminaires
For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC:
Type 3R, 4X
IP66, IP67
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)

Photometric Data — DATA SHOWN IS ABSOLUTE

REPORT NUMBER: IAMLED77YBU1_FLOOD


Lamps: Areamaster, High Bay Mount, LED Board 56 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear
Characteristics: Maximum Candela: 5818; Maximum Candela Angle: 22.5 H 25.5 V; Horizontal Beam Angle (50%): 97.0; Vertical Beam Angle (50%): 102; Horizontal Field
Angle (10%): 134; Vertical Field Angle (10%): 134; Beam Lumens 10414; Field Lumens 12967; Luminaire Lumens 13157
LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION

AXIAL CANDELA AXIAL CANDELA DISPLAY ISOCANDELA CURVES


DEG. HOR. VERT.
90.0 0 0
85.0 21 2
75.0 26 5 90
65.0 700 733
55.0 2400 2341 581.8
47.5 3023 2976 60

42.5 3375 3307 2909


37.5 3838 3826
30
33.0 4312 4319
29.0 4670 4719 1250

Vertical Angles
25.5 4964 4898 0
22.5 4910 4857
19.5 4700 4660
17.0 4456 4343 2500 -30
15.0 4273 4249
13.0 4184 4165
-60
11.0 4154 4123
9.0 4139 4105 3750
7.0 4124 4119
-90
5.0 4127 4133 0 30 60 90
Horizontal Angles
3.0 4138 4150
1.0 4149 4153
0.0 4149 4149

CIE Type – Direct


REPORT NUMBER: IAMLED77YBU1_HIGHBAY
Spacing
Plane Lamps: Areamaster, High Bay Mount, LED Board 56 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered
Criteria
0 Deg 1.5
To 3-1/2 X 3-1/2, Lens Clear
90 Deg 1.5 Coefficients of Utilization - Zonal Cavity Method
Effective Floor Cavity Reflectance 0.20
Zone Lumens % Ceiling Rcc 80 70 50 30 10 0
0-5 98 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
90˚
5-10 290 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
10-15 485 1 111 107 103 100 108 105 102 99 101 98 96 97 95 93 93 92 90 88
15-20 711 75˚ 2 102 95 89 84 99 93 88 83 90 85 81 86 83 79 83 80 78 76
20-25 993 3 94 84 77 71 91 83 76 70 80 74 69 77 72 68 75 70 67 65
1250
25-30 1264 4 86 75 67 61 84 74 66 60 71 65 59 69 63 59 67 62 58 56
30-35 1440 60˚
5 79 67 59 52 77 66 58 52 64 57 52 62 56 51 60 55 50 48
35-40 1517 6 73 60 52 46 71 59 51 45 58 50 45 56 50 45 54 49 44 42
40-45 1471 7 67 54 46 40 66 54 46 40 52 45 40 51 44 39 49 44 39 37
2500
45-50 1392 8 63 50 41 36 61 49 41 36 48 40 35 46 40 35 45 39 35 33
45˚
50-55 1283 9 58 45 37 32 57 45 37 32 44 37 32 43 36 31 42 36 31 30
55-60 1086 10 55 42 34 29 53 41 34 29 40 33 29 39 33 28 38 32 28 27
60-65 764
3750
65-70 340 Zonal Lumen Summary
0˚ 15˚ 30˚
70-75 37 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
75-80 4 0-30 3841 N.A. 29.1 90-130 2 N.A. 0.0
80-85 2 0-40 6798 N.A. 51.5 90-150 6 N.A. 0.0
85-90 1 0-60 12029 N.A. 91.1 90-180 7 N.A. 0.1
0-90 13177 N.A. 99.8 0-180 13199 N.A. 100
90-120 1 N.A. 0.0

150 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Industrial Areamaster™ LED Flood/High Bay Luminaires
For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

NEC/CEC:
Type 3R, 4X
IP66, IP67
Suitable for use in Wet Locations
Marine Outside Type (Salt Water)

Photometric Data — DATA SHOWN IS ABSOLUTE

REPORT NUMBER: IAMLED87YBU1_FLOOD


Lamps: Areamaster, Pendent Mount, LED Board 20 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2, Lens Clear
Characteristics: NEMA Type: 7Hx7V; Maximum Candela: 8092; Maximum Candela Angle: 25.5H 25.5V; Horizontal Beam Angle (50%): 97.3; Vertical Beam Angle (50%):
103; Horizontal Field Angle (10%): 137; Vertical Field Angle (10%): 136; Beam Lumens 14933; Field Lumens 18585; Luminaire Lumens 18842

LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION


AXIAL CANDELA AXIAL CANDELA DISPLAY ISOCANDELA CURVES
DEG. HOR. VERT.
90 0 0
85 31 5
75 36 8 90

65 1239 938
55 3463 3477 581.8
60
47.5 4393 4345
42.5 4921 4831 2909

37.5 5955 5752 30


33 6455 6392
2023

Vertical Angles
29 6656 6778
25.5 6998 7087 0

22.5 7109 7158 4046


19.5 6665 6664
-30
17 6302 6222
15 6059 6108
6069
13 6027 6044 -60
11 5931 5942
9 5914 5938
7 5933 5956 8092 -90
0 30 60 90
5 5974 5975 Horizontal Angles

3 6003 5995
1 6002 6004
0 5999 5999

CIE Type – Direct


REPORT NUMBER: IAMLED87YBU1_HIGHBAY
Spacing
Plane Lamps: Areamaster, High Bay Mount, LED Board 20 LEDs, Specular Reflector 6-1/2 X 6-1/2 Tapered
Criteria
0-180 1.54
To 3-1/2 X 3-1/2, Lens Clear
90-270 1.54
Coefficients of Utilization - Zonal Cavity Method
Zone Lumens Effective Floor Cavity Reflectance 0.20
0- 5 141 % Ceiling Rcc 80 70 50 30 10 0
5- 10 419 % Walls Rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
90˚
10- 15 697 0 119 119 119 119 116 116 116 116 111 111 111 106 106 106 102 102 102 100
15- 20 1004 1 111 107 103 100 108 105 101 99 100 98 95 97 95 93 93 91 90 88
20- 25 1408 75˚ 2 102 95 89 84 99 93 88 83 89 85 81 86 83 79 83 80 77 75
25- 30 1794 3 93 84 77 71 91 82 76 70 80 74 69 77 72 68 74 70 67 65
2500
30- 35 2079 4 86 75 67 60 84 73 66 60 71 64 59 69 63 58 67 62 58 56
35- 40 2151 60˚
5 79 67 58 52 77 66 58 52 64 57 51 62 56 51 60 55 50 48
40- 45 2143 6 73 60 52 45 71 59 51 45 57 50 45 56 49 45 54 49 44 42
45- 50 2011 7 67 54 46 40 66 54 46 40 52 45 40 51 44 39 49 43 39 37
5000
50- 55 1834 8 63 49 41 36 61 49 41 35 47 40 35 46 40 35 45 39 35 33
45˚
55- 60 1567 9 58 45 37 32 57 45 37 32 43 36 31 42 36 31 41 35 31 29
60- 65 1118 10 54 42 34 29 53 41 34 29 40 33 28 39 33 28 38 32 28 26
65- 70 514 7500
70- 75 62 Zonal Lumen Summary
0˚ 15˚ 30˚
75- 80 3 Zone Lumens % Lamp % Fixture Zone Lumens % Lamp % Fixture
80- 85 2 0-30 5462 N.A. 28.8 90-130 3 N.A. 0
85- 90 1 0-40 9692 N.A. 51.2 90-150 5 N.A. 0
0-60 17247 N.A. 91.1 90-180 7 N.A. 0
0-90 18946 N.A. 100.1 0-180 18933 N.A. 100
90-120 2 N.A. 0

Visit our website at www.emerson.com or contact us at (800) 621-1506. 151


© May 2016
Areamaster™ Green LED Flood/High Bay Luminaires
General Duty

NEC/CEC:
Rated for Ordinary (Classified) Locations

Applications
• Locations where a green light is required for steel
manufacturing quality inspection
Features
• LED color: green.
LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION

• Compact in size, attractively styled contemporary design,


rugged and dependable.
• Easy to install and service.
• One-piece housing.
• One-piece lens cover. Secured by four M6 captive stainless
steel slotted hex-head bolts.
• Thermal shock and impact resistant glass lens.
• Heavy duty, high temperature silicone rubber gasket, firmly
seated.
• Floodlight Mounting: Floodlight
— Yoke mount, zinc plated steel yoke with architectural bronze
polyester finish.
• High Bay Mounting:
— (1) Conduit entry on back of luminaire.
— Rotate yoke up or remove.
• Vibration rated in all configurations.
• Cool operating temperatures translate into long luminaire life.
• Total of three (3) 3/4" NPT entries with integral bushings.
• Two (2) aluminum close up plugs provided.
• Electrical: 120-277 Vac, 50/60 Hz.
• Nominal input power: 165.
• Maximum input Amps: 1.40 - 0.60.
High Bay
• Power factor: > 0.90.
• Terminal block (screw type for secure connection) can accept
24-10 AWG wire.
Standard Materials
• Ballast housing and lens door: copperfree (4/10 of 1% max.)
aluminum
• Gasket: silicone rubber
• Reflector: metallized high reflectance finish
• Yoke mount: zinc plated steel
• Bolts: stainless steel
• Plugs: (2) aluminum provided
Standard Finishes
• Housing, lens cover and yoke mount: architectural bronze
polyester

152 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Areamaster™ Green LED Flood/High Bay Luminaires
General Duty

NEC/CEC:
Rated for Ordinary (Classified) Locations

Line Voltage Yoke Mount Catalog Number

120-277
AMLED774BU1GR
50/60 Hz

LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION


Accessories

Description Catalog Numbers


Crossarm Mounting Bracket

Has 180° horizontal adjustment — degree marked. Facilitates mounting


floodlight to crossarm or other flat surface, or to G-AM-8-WB. Includes
G-AM-8-CA
floodlight yoke bolts. Malleable iron, zinc plated, chromate sealed,
architectural bronze polyester finish.

Pipe or Wall Mount Bracket

Used with G-AM-8-CA. Clamps to 1” to 2-1/2” pipe, vertical or horizontal,


or mounts on flat surfaces. Includes U-bolt and crossarm bracket bolts.
G-AM-8-WB
Malleable iron, zinc plated, chromate sealed, with architectural bronze polyster
finish.

Poletop Slip-Fitter

Slip-fits 1-1/2” or 2” pipe size poletop tenons. Includes floodlight yoke bolts,
3 locking bolts, and cord grip. Body is malleable iron-zinc plated, chromate
G-SF20
sealed, with cast aluminum cap. Assembly has architectural bronze polyester
finish.

Poletop Slip-Fitter

Slip-fits 2” or 2-1/2” poletop tenons. Includes floodlight yoke bolts, 3 locking


bolts, and cord grip. Malleable iron, zinc plated, chromate sealed, with G-AM-8-SF
architectural bronze polyester finish.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 153


© May 2016
Areamaster™ Green LED Flood/High Bay Luminaires
General Duty

NEC/CEC:
Rated for Ordinary (Classified) Locations

Dimensions in Millimeters (Inches)


Floodlight

388.6 mm (15.30 in)


93.9 mm (3.70 in)
LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION

4645.2 mm2
(7.20 in2)
358.1 mm Conduit
(14.10 in) Entry 391.2 mm
(Pendant (15.40 in)
Mount)

Set
Screw144.78 mm
(5.70 in)

57.2 mm Yoke (3) hubs for


(4) Yoke Bolts (2.25 in.) 3/4" NPT Conduit
122.7 mm
Conduit 3.64 Turning Radius (4.83 in) 88.9 mm
(3.50 in)
Entry 180° Rotation
44.45 mm (3) Mounting Holes
(1.75 in) 0.56 Dia.
88.9 mm (3.50 in)

High Bay Pendant Mount

Ceiling
Rotate Yoke Up
Recommended Minimum Juction Box or Remove
Mounting Distance Set Screw
304.8 mm (12 in)

152.4 mm
(6 in)

154 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Areamaster™ Green LED Flood/High Bay Luminaires
General Duty

NEC/CEC:
Rated for Ordinary (Classified) Locations

Photometric Data — DATA SHOWN IS ABSOLUTE


REPORT NUMBER: AMLED77YBUGR
Fixture: Flood Mount, Led Board 60 LED, Specular Reflector 6-1/2 X 6-1/2 Tapered To 3-1/2 X 3-1/2 , Lens Clear 7 x 7"

LED/FLOODLIGHTS: NEC/CEC ORDINARY LOCATION


Floodlight Characteristics
IES Type 7H X 7V
Maximum Candlepower 3424. AT 22.5 H, 25.5 V
Horizontal Beam Angle (50%) 101.5 deg
Vertical Beam Angle (50%) 100.3 deg
Horizontal Field Angle (10%) 134.6 deg
Vertical Field Angle (10%) 134.2 deg
Beam Lumens (Efficiency) 6436. (79.7)
Field Lumens (Efficiency) 7949. (98.4)
Total Lumens (Efficiency) 8075. (100.0)

Axial Candlepower Plot(s) is/are single sweep(s) — Stray light is NOT accounted for. Lateral trace thru 90 deg Vertical.

Deg Horizontal Deg Vertical


90.0 0. 90.0 0.
85.0 20. 85.0 1.
75.0 22. 75.0 3.
65.0 438. 65.0 444.
55.0 147 9. 55.0 1460.
47.5 1889. 47.5 1828.
42.5 2146. 42.5 2121.
37.5 2539. 37.5 2515.
33.0 2807. 33.0 2928.
29.0 3043. 29.0 3121.
25.5 3163. 25.5 3186.
22.5 3063. 22.5 3080.
19.5 2968. 19.5 2936.
17.0 2807. 17.0 2758.
15.0 2795. 15.0 2731.
13.0 2771. 13.0 2706.
11.0 2732. 11.0 2704.
9.0 2714. 9.0 2711.
7.0 2721. 7.0 2722.
5.0 2728. 5.0 2731.
3.0 2736. 3.0 2730.
1.0 2729. 1.0 2731.
0.0 2730. 0.0 2730.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 155


© May 2016
ATX™ FDBAES LED Series Self-Contained Emergency Lighting Units
Flameproof

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/68 - IK08

Applications
• Provides adequate lighting and/or visual indication of access on
exit routes during an evacuation in a hazardous environment.
• Can be installed in hazardous areas designated as Zone 1 and
2 – 21 and 22.
• Typical applications include oil refineries, petrochemical plants,
pulp and paper mills.
FDBAESLEDEM
Features
All versions:
• Power supply 230 Vac, 50/60 Hz.
• 1 hour duration (emergency).
• Threaded access cover with O-ring seal.
• Can be maintained in hazardous areas as an internal switch cuts
off battery supply automatically once the cover is unscrewed Options
and opened. • Addressable monitoring software, please consult your local
• Battery pack. sales representative.
• Escape route lighting: 2.4 V - 1.5 Ah (2 cells - Nicd) • Low temperature application, please consult your local sales
Space lighting: 7.2 V - 2.2 Ah (6 cells - NiMh) - Flameproof representative.
• Padlockable switch is available on switched models which
individually cuts off power supply and remote control. ATEX/IECEx Certifications and Compliances
• Charge indicator by 1 green LED (life time over 10 years). • Certification Type: FLd
• Operates in any position. — Gas: Zone 1 - 2
• Connection to plug-in terminal block via 2 x 5 x 2.5 mm2 (0.003 – Conforming to ATEX 94/9/CE: II 2 G
x 0.008 x 0.004 in2) terminals. – Type of Protection: Ex d IIC
• Supplied with two fixing lugs. – Temperature class: T6
• Automatic built-in self-test system (SATI) with memorization of — Dust: Zone 21 - 22
tests indicated by LEDs. – Conforming to ATEX 94/9/CE: II 2 D
• Using a microprocessor and an internal clock, the unit will carry – Type of Protection: Ex tD A21
out automatic tests. – Surface Temperature: T80 °C (T176 °F)
• Weekly test: Lamp check during 6 seconds. • Ambient Temperature: -40 °C to +55 °C (-40 °F to +131 °F) 
• Quarterly test: Emergency operation and lamp check for 1 hour.
LED/ATEX/IECEx BULKHEAD

• CE Declaration of Conformity: 50203


• Can be remotely controlled and checked without switching • ATEX Certificate: LCIE 97/ ATEX 6012
the mains off with remote control unit from Legrand (Catalog • IECEx Certificate: IECEx LCI 04.0018
Number 03901) or URA (Catalog Number 095448 and 095450) • Index of Protection according EN/IEC 60529: IP66/68
manufacturers. • Impact Resistance (shock): IK08
• The remote control unit installed in a safe area or inside a • Internal Volume: > 2 dm3 (122 in³) - 2 liters
flameproof box allows manual ignition of all the units (maximum • Conforming to NF AEAS
300 units) for visual inspection of their operation.
• Escape route lighting: 55 lumens, 0.50 wattage. EURASEC Certification
Space lighting: 540 lumens, 0.95 wattage. • EURASEC N° TC RU C-FR.ГБ05.B.00912
Addressable versions:
• Operates without additional control lines. Communication
Other Certification
between units and the control system is realized via mains • INMETRO Certificate: BVC 11.0492 
borne signals that utilize the existing electrical wiring. Related Products
• Standard control system capacity: one control system for up to
• For labels see Labels for Emergency Lighting Units, ATX Self-
200 emergency lighting units.
Adhesive Signaling Labels for Emergency Lighting Units.
• Optional increased control system capacity: booster (repeater
unit) is used to increase the length of the network allowing up
to 1000 emergency lighting units to be on one control system.
This allows for the use of a single computer to centralize the
management of the facilities emergency lighting system. For
more information, please contact your local sales representative.
Standard Materials
• End caps and cover: aluminum
• O-ring seal: Nitrile
• Lens: tempered borosilicate glass
• Fixing brackets: zinc plated steel or 316 stainless steel
• Accessories: white painted galvanized steel
• Guard: zinc plated steel

 Optimum operating temperature for battery is -5 °C to +30 °C (+23 °F to +86 °F)


 Inmetro certification available on special request only. Contact your local sales representative for more information.

156 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
ATX™ FDBAES LED Series Self-Contained Emergency Lighting Units
Flameproof

ATEX/IECEx:
Zone 1 and 2 - 21 and 22
II 2 GD
IP66/68 - IK08

Catalog Numbering Guide


FDBAES LED SL N A

Series: SL - Space Lighting Options:


FDBAES - FDBAES Series E - Escape Route Lighting A - Addressable
Zone 1 and 2 – 21 and 22 W - With Switch (main supply
ATEX/IECEx Certified and remote)

Lamp Type: Cable Entry:


LED N - 3/4" NPT
M - Metric M20

Weight Volume
Type Lamp Lumen Output Cable Entries kg (lb) dm3 (in3) Catalog Number

Unswitched Version — 1 hour duration — Non-maintained — Two threaded cable entries with one blanking plug
3/4" NPT FDBAESLEDSLN
Space Lighting LED Array 540 lm  8.1 (0.32) 37.1 (2264.0)
M20 FDBAESLEDSLM

3/4" NPT FDBAESLEDEN


Escape Route
LED Array 55 lm  8.1 (0.32) 37.1 (2264.0)
Lighting
M20 FDBAESLEDEM

Switched Version — 1 hour duration — Non-maintained — One threaded cable entry

LED/ATEX/IECEx BULKHEAD
3/4" NPT FDBAESLEDSLNW
Space Lighting LED Array 540 lm 10.0 (0.39) 40.4 (2465.4)
M20 FDBAESLEDSLMW

3/4" NPT FDBAESLEDENW


Escape Route
LED Array 55 lm 10.0 (0.39) 40.4 (2465.4)
Lighting
M20 FDBAESLEDEMW
Addressable and Unswitched Version — 1 hour duration — Non-maintained — Two threaded cable entries with one blanking plug
3/4" NPT FDBAESLEDSLNA
Space Lighting LED Array 540 lm 8.1 (0.32) 37.1 (2264.0)
M20 FDBAESLEDSLMA

3/4" NPT FDBAESLEDENA


Escape Route
LED Array 55 lm 8.1 (0.32) 37.1 (2264.0)
Lighting
M20 FDBAESLEDEMA

Addressable and Switched Version — 1 hour duration — Non-maintained — One threaded cable entry

Space Lighting LED Array 540 lm M20 10.0 (0.39) 40.4 (2465.4) FDBAESLEDSLMAW

Escape Route
LED Array 55 lm M20 10.0 (0.39) 40.4 (2465.4) FDBAESLEDEMAW
Lighting

 Value measured after 1 hour duration - required value by standard is 400 lm.
 Value measured after 1 hour duration - required value by standard is 45 lm.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 157


© May 2016
Baymaster™ Prismatic 250/400 High Bay Luminaires
150 W, 250 W, 400 W HPS.

NEC/CEC:
Listed for Ordinary (Unclassified) Locations

Applications
• For illumination of manufacturing, storage, and other indoor
areas.
Features
• Standard Baymaster fixtures operate in +40 °C (+104 °F)
ambient temperatures. All units suitable for minimum +90 °C
(+194 °F) supply wire.
• High efficiency (up to 78% with 250 W HPS lamps) with
HID/AREA: NECC/CEC ORDINARY LOCATION HIGH BAY

exceptionally long lamp life—economical to own and operate.


• A wide range of ballasts and voltages are available for both
domestic and export applications.
• Integral ballast.
• Mogul base sockets with spring loaded center contact and
heavy guage screw shell with double lamp grips to prevent
lamps from loosening due to vibration.
• Efficient, low glare, compact reflector is UV stabilized,
clear, injection molded high-temperature acrylic that provides
15-20% uplight.
• Reflector installs and adjusts to wide, medium, or narrow
distribution (without tools) by repositioning spring locks.
• Installation is quick and easy:
(1) mount junction box to 3/4” conduit
(2) slide ballast onto junction box
(3) make connections
(4) install lamp Dimensions in Millimeters (Inches)
(5) snap reflector in place
• Open-top reflector design keeps reflector clean because of
thermal barrier and chimney effect, and provides up-light to
relieve contrast.
Standard Materials
• Ballast: finned, aluminum
• Sockets: heavy duty porcelain
• Reflector: acrylic Spring Position
• Locks: stainless steel Upper: 635.0 mm (25.0")
Center: 660.4 mm (26.0")
Standard Finishes Lower: 692.2 mm (27.25")
• Ballast: corrosion polyester
• Sockets: nickel plated center contact
• Screws: nickel plated brass
Options
• All units available with a sensor circuit for automatically
lighting an auxiliary safety lamp if a power dip or lamp failure 412.8 mm
extinguishes the HID lamp. (16.25")
NEC/CEC Certifications and Compliances
• UL Listed: E109438
• UL Standard: 1598
• CSA Certified: LR9349
Related Products
• For power hook, fusing and other suspension accessories, see
Fixture Hanger Accessories page.

384 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Baymaster™ Prismatic 250/400 High Bay Luminaires
150 W, 250 W, 400 W HPS.

NEC/CEC:
Listed for Ordinary (Unclassified) Locations

High Pressure Sodium Lamps — Pendant Mounting

Catalog Number
Lamp Wattage Voltage Complete Assembly  Ballast Housing Assembly
120/208/240/277 V G-HB41PL-MT G-HB411L-MT
150 W 120/277/347 V G-HB41PL-TT  G-HB411L-TT 
480 G-HB41PL-48 G-HB411L-48

HID/AREA: NECC/CEC ORDINARY LOCATION HIGH BAY


120/208/240/277 V G-HB61PL-MT G-HB611L-MT
250 W 120/277/347 V G-HB61PL-TT  G-HB611L-TT 
480 G-HB61PL-48 G-HB611L-48
120/208/240/277 V G-HB71PL-MT G-HB711L-MT
400 W 120/277/347 V G-HB71PL-TT  G-HB711L-TT 
480 G-HB71PL-48 G-HB711L-48

Accessories

Description Catalog Number

16” Prismatic Reflector only. G-7PR

16” Prismatic Reflector with clamp band and clear tempered glass lens. G-7PR-IL 

16” Prismatic Reflector with clamp band and prismatic acrylic lens. G-7PR-ILP 

 To order fixture complete with lamp, add suffix -L to catalog number.


Add suffix -E to catalog number if provision for 150 W quartz emergency lamp is desired (lamp not included). Furnished with socket installed and pre-wired.
 Supplied complete with CWA Ballast. For 208, 240, 480 or 600 V CWI applications, change the -TT suffix to -C2, -C3, -C6 or -C7 as required.
 Certified to meet the Canadian Electrical Code (CEC) only.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 385


© May 2016
Baymaster™ Prismatic 250/400 High Bay Luminaires
150 W, 250 W, 400 W HPS.

NEC/CEC:
Listed for Ordinary (Unclassified) Locations

Electrical Specifications — High Pressure Sodium — All ballasts are C.W.A. type, except 150 W HPS which is HX-Auto
• Ballast has primary taps for 120, 208, 240 and 277 Volts.

150 Watt 250 Watt 400 Watt


Line Volts Start Operating Total Watts Start Operating Total Watts Start Operating Total Watts
120 2.00 1.70 188 2.00 2.50 295 3.30 3.80 465
208 1.15 0.95 188 1.20 1.50 295 1.80 2.20 465
HID/AREA: NECC/CEC ORDINARY LOCATION HIGH BAY

240 1.00 0.85 188 1.00 1.30 295 1.60 1.90 465
277 0.85 0.72 188 0.85 1.10 295 1.40 1.70 465
347  0.52 0.56 188 0.60 0.93 295 1.00 1.32 465
480 0.50 0.47 189 0.40 0.65 295 0.80 1.00 465

Quick Estimate Illumination Charts 


How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 232.2 m2 (2500 ft2) or less. “Medium Room” is 232.2 m2 (2500 ft2) thru
929.0 m2 (10,000 ft2). A “Large Room” is 929.0 m2 (10,000 ft2) or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated)
to right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
400 Watt High Pressure Sodium 250 Watt High Pressure Sodium

 Photometric charts available on request.


 Certified to meet the Canadian Electrical Code (CEC) only.

386 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Baymaster™ Prismatic 250/400 High Bay Luminaires
150 W, 250 W, 400 W HPS.

NEC/CEC:
Listed for Ordinary (Unclassified) Locations

Photometric Data 

Square Steel Poles for Davit Mount Luminaires

Typical Footcandle Values


Distance (ft) Mounting Height Feet 400 Watt High Pressure Sodium
Ahead/
Behind

HID/AREA: NECC/CEC ORDINARY LOCATION HIGH BAY


Footcandle 30 40 50 60
165 — — .01 .02
160 — — .01 .03

Distance in terms of mounting height ◊


155 — — .01 .03
150 — — .02 .04
145 — — .02 .04
140 — .01 .03 .06
135 — .01 .03 .09
130 — .01 .04 .14
125 — .02 .05 .20
120 — .03 .06 .27
115 — .04 .10 .35
110 .01 .05 .17 .46
105 .01 .06 .26 .60
100 .02 .08 .38 .77
95 .03 .10 .54 .93
90 .05 .21 .74 1.13
85 .07 .37 1.00 1.37
80 .10 .60 1.29 1.66 Distance in terms of mounting height ◊
75 .14 .91 1.62 2.02
70 .23 1.35 2.05 2.16
65 .55 1.91 2.69 2.21
60 1.06 2.53 9.07 2.21
55 1.85 3.39 3.17 2.18 400 W HPS Ft. Candles for Iso-Footcandle Lines
50 3.08 4.55 3.19 2.34 Mtg. Ht. A B C D E F G H
45 4.51 4.93 3.16 2.24 20 29.03 20.21 19.19 8.07 2.39 .39 .17 .04
40 6.64 4.98 3.23 2.31 25 18.58 12.91 12.28 5.16 1.53 .25 .11 .04
35 8.65 4.98 3.18 2.57 30 12.90 8.98 8.53 3.59 1.06 .17 .08 .03
30 8.85 5.04 3.63 2.85 35 9.48 6.60 6.27 2.63 .78 .13 .06 .02
25 8.95 5.49 4.10 3.16 40 7.26 5.05 4.80 2.02 .60 .10 .04 .02
20 9.25 6.41 4.64 3.43 45 5.73 4.00 3.79 1.59 .47 .08 .03 .01
15 11.4 7.47 4.95 3.41
10 13.7 7.67 4.83 3.18 This report has been prepared in accordance with IES guides on testing procedures. It is
5 12.7 6.53 3.93 2.60 representative of luminaires tested under standardized and stabilized laboratory conditions.
0 6.58 3.70 2.37 1.65 Various operating factors can cause differences between laboratory data and actual field
-5 1.15 .81 .58 .48 performance.
-10 .60 .40 .33 .29
-15 .77 .31 .23 .18
-20 1.13 .43 .21 .15
-25 1.11 .59 .26 .15
-30 .85 .70 .35 .19

 Additional photometric charts available on request.


 Distance in terms of mounting height (i.e., ratio) of distance to height. Example: @ 4.6 m (15 ft) mounting height, 1 means 4.6 m (15 ft); 2 means 9.1 m (30 ft),
etc.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 387


© May 2016
Super-Baymaster™ High Bay Luminaires
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HPS; 1000 W PSMH; 1000 W MH.

CEC:
Listed for Ordinary (Unclassified) Locations

Applications
• For illumination of mills (pulp and paper), manufacturing, storage
and other areas where corrosion, moisture or dust present
severe problems.
• CSA approved weatherproof (Encl. 3) with open reflector and
dust-tight (Encl. 3 and 5) with enclosing lens.
• Will operate safely in temperatures ranging from -40 °C to
+65 °C (-40 °F to +149 °F) ambient.
Features
HID/AREA: NECC/CEC ORDINARY LOCATION HIGH BAY

• Corrosion resistant. All external surfaces of the ballast housing


are coated with a heavy-duty epoxy-finish providing
durability and resistant to both alkali and acidic atmospheric
conditions. To suit specific atmospheric requirements,
consult the factory for a suitable finish.
• High efficiency reflectors (up to 76% with 1000 W MH lamps)
and ­exceptionally long HID lamp life make Super-­Baymaster
luminaires unusually economical to own and operate.
• The Baymaster reflector is a unique ­design that combines high
efficiency with low glare in a compact size.
• Super-Baymaster luminaires are furnished with open reflectors.
For enclosed reflectors, clear or prismatic glass are available.
• Pre-wired with high temperature fixture wire, these integral
ballasted luminaires are supplied with dual-tap primary for 120
or 240 Volt lines or with 208, 277 or 347 Volt primary. Ballasts
are highest quality, Class H insulated, CWA and CWI types, Shown with optional lens: 1000 W
­thermally isolated for cooler operating and
long life. Grounding wire provided.
• To protect the internal components of the luminaire from Dimensions in Millimeters (Inches)
corrosive atmospheres all mating surfaces are gasketed.
• Mogul base socket with spring loaded center contact and heavy Height
gauge, screw shell with double lamp grips to prevent lamps 530.4 mm (20-7/8"); 150-400 W HPS
from loosening due to vibration. 500.1 mm (19-11/16"); 1000 W HPS, PSMH, MH
• Installation is quick and easy:
(1) lift ­ballast assembly onto the hanger hub and rotate 60° until
sealed on hub Width
(2) tighten locking nut (hand tight) to secure ballast assembly 406.4 mm (16"); 150-400 W HPS
(3) make supply connections (90° wire) and replace wiring cover 508.0 mm (20"); 1000 W HPS, PSMH, MH
(4) snap reflector in place
(5) install lamp Height
736.6 mm (29"); 150-400 W HPS
Standard Materials 787.4 mm (31"); 1000 W HPS, PSMH, MH
• Reflector: aluminum
• Sockets: porcelain
Width
Standard Finishes 406.4 mm (16"); 150-400 W HPS
• Screws: nickel plated brass 508.0 mm (20"); 1000 W HPS, PSMH, MH
• Housing: epoxy powder coated external surfaces
Options
• Quartz auxiliary: units are available with a pre-wired sensor CEC Certifications and Compliances
circuit for automatically lighting a quartz auxiliary lamp when
power dip or lamp failure extinguishes the main HID lamp. • CSA Certified: 009349
• Fuse kits: for grounded systems. • CSA Standard: C22.2 No. 250.0
• Lenses: clear or prismatic glass with heavy-duty, stainless steel Related Products
clips to secure lens to reflector.
• For power hook, fusing and other suspension accessories, see
• HPS units available with a pulse ­eliminator which effectively
Fixture Hanger Accessories page.
shuts down the ballast assembly when lamp fails.
• Optional finishes may be ordered to suit specific environments
in regular or ­specific colors.

388 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016
Super-Baymaster™ High Bay Luminaires
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HPS; 1000 W PSMH; 1000 W MH.

CEC:
Listed for Ordinary (Unclassified) Locations

Order using catalog numbering guide below or select catalog number from tables on following pages.
Catalog Numbering Guide for GSB and GSS
GSB 4 1 A L C MT E

Series: Reflector: Voltage:


GSB – Super- A – Complete with reflector MT – 120, 208, 240, 277
Baymaster Blank – Ballast assembly only Volts CWA
GSS – Super- TT – 120, 277, 347 Volts

HID/AREA: NECC/CEC ORDINARY LOCATION HIGH BAY


Baymaster CWA
Side by Side 208 – 208 Volts
RB – Remote Ballast

Wattage: Lamp Type: Voltage:


4 – 150 Watt  L – High Pressure Sodium E – Provision for 250 Watt quartz
5 – 175 Watt  H – Metal Halide  emergency lamp (pre-wired)
6 – 250 Watt  P – Pulse Start Metal Halide  S – Provision for pulse eliminator
7 – 400 Watt  F – Fuse for grounded systems (single
8 – 1000 Watt pole)
LC – Gasketed clear lens assembly
LP – Gasketed prismatic lens assembly
CR – Corrosion resistant epoxy paint on
reflector exterior surface
Beam Spread: Ballast Type:
1 – Narrow (not for 1000 W) C – CWI
2 – Medium A – CWA
3 – Wide

Accessories and Replacement Parts


Description Catalog Number

Wire Guard With relamp door. Zinc plated G-HB20-G

Safety Chain Secures ballast and reflector G-HB-7000-SC

Supplied with 0.91 meters (3 feet) of 600 Volt +90 °C (+194 °F) 3-conductor
Wiring Kit no. 16 SOW cable and 19.1 mm (3/4”) FHHM hook (shipped ­separately) PWK
Add Suffix:

Socket for Metal Halide SPF-1004


Sockets
Socket for High Pressure Sodium SPF-1001

 Only available in high pressure sodium.


 Only available in 1000 Watt.

Visit our website at www.emerson.com or contact us at (800) 621-1506. 389


© May 2016
Super-Baymaster™ High Bay Luminaires
High Bay Luminaires for Mill Duty and Corrosive Atmospheres
150 W, 175 W, 250 W, 400 W or 1000 W HPS; 1000 W PSMH; 1000 W MH.

CEC:
Listed for Ordinary (Unclassified) Locations

Luminaire Performance — High Pressure Sodium

150 Watt 175 Watt 250 Watt 400 Watt 1000 Watt
Spacing to Spacing to Spacing to Spacing to Spacing to
Distribution Mounting Mounting Mounting Mounting Mounting
 Efficiency Height Efficiency Height Efficiency Height Efficiency Height Efficiency Height
Narrow 66.3% 0.5:1 66.3% 0.5:1 68.9% 0.5:1 66.4% 0.5:1 — —
Medium 71.3% 1.1:1 71.3% 1.1:1 74.4% 1.7:1 71.4% 1.1:1 71.3% 0.7:1
HID/AREA: NECC/CEC ORDINARY LOCATION HIGH BAY

Wide 73.3% 2.0:1 73.3% 2.0:1 78.0% 2.0:1 73.5% 2.0:1 74.4% 1.4:1

Luminaire Performance — Metal Halide

1000 Watt
Distribution  Efficiency Spacing to Mounting Height
Narrow — —
Medium 76.2% 1.1:1
Wide 75.4% 2.5:1

Quick Estimate Illumination Charts 


How to use Quick-Estimate Illumination Chart
1. Refer to “Quick-Estimate Illumination Chart” for the lamp type and wattage to be used.
2. Determine “room size” of area to be lighted. “Small Room” is 232.2 m2 (2500 ft2) or less. “Medium Room” is 232.2 m2 (2500 ft2) thru
929.0 m2 (10,000 ft2). A “Large Room” is 929.0 m2 (10,000 ft2) or more.
3. Find level of light (footcandles) required in vertical column of figures at left of chart. Then follow horizontal line (real or interpolated)
to right until it intersects with “Arc” of selected “room size.” Come directly down from point of intersection to horizontal line of number
“Square Feet Per Luminaire.” The resulting number (real or interpolated) is the “number of square feet” one Appleton Baymaster will
illuminate to the selected average maintained footcandle level when mounted in conjunction with other units in the high bay installation.
4. Divide number of total square feet in project by “number of square feet per luminaire” to get number of units required.
5. Take square root of resulting “number of square feet per luminaire” number to determine spacing between units.
1000 Watt High Pressure Sodium 1000 Watt Metal Halide

 Reflector adjusts for narrow to medium to wide distribution without tools.


 Photometric charts available on request.

390 Visit our website at www.emerson.com or contact us at (800) 621-1506.


© May 2016