You are on page 1of 4

Mute call detection guide- How to enable MCLOG feature in BSC internal

 Configure BSC attribute


1. Start LMT client
2. Choose BSC6000, (Press ctrl+shift+F12), Choose “configure BSC attribute”

3. Choose “inner soft parameter”, and then configure “Speech Channel Alarm Threshold”,
“Speech Channel Resume Alarm Threshold” and “TC Mute Detect Class1 Threshold (%)” as
below.

2016-10-18 华为机密,未经许可不得扩散 第 1 页, 共 4 页
Mute call detection guide- How to enable MCLOG feature in BSC internal

 Configure Cell attribute


1. Choose BSC6000, (Press ctrl+shift+F12), choose “Configure Cell attribute”

2. Choose “Other Attributes”, “Advanced”, “inner cell soft parameter”, configure “TC Mute
Detect Flag”, “Mute Detect Class2 Switch”, “Period of Mute Detect Class1(s)”,
“Exceptional Frame Threshold(%)”, “Period of Detect Frame[0.25s]” and “Mute Detect
Times(s)” as below.

2016-10-18 华为机密,未经许可不得扩散 第 2 页, 共 4 页
Mute call detection guide- How to enable MCLOG feature in BSC internal

 Configure DPU board attribute


1. Select DPU board (including all GDPUC and GDPUX boards), choose “Configure Board
Attributes”.

2016-10-18 华为机密,未经许可不得扩散 第 3 页, 共 4 页
Mute call detection guide- How to enable MCLOG feature in BSC internal

2. Click next; configure “Mute Detect” and “Mute Timer”.

When you finish all the above operations, Please make calls under this BSC.
After 2 hours, you should feed back all the logs under this directory:
\\OMU IP\bsc6000\data\mtndata\log\txt\mclog

Note: This feature for detect mute call in BSC will work in the BTS version V1R8C11SP45
AND LATER VERSION.

2016-10-18 华为机密,未经许可不得扩散 第 4 页, 共 4 页