Testing 110 V Appliances

Application note 39

110V Appliances Extension Leads

Using the Megger PAT4DV/3, the PAT300 series 110 V leads tend to be found with different
and PAT400 series, the testers need to be supplied polarities; therefore we do not check the polarity of
by 110 V in order to perform an operations or 110 V leads. If we did, we would probably be failing
leakage tests on 110 V appliances. This way, the 50% of them. To check an extension lead, we need
PAT testers are lighter and cheaper to make, to check the earth is complete. Therefore, link the
therefore better for the customer! other end of the lead back into the tester so a bond
or continuity test can take place. An adaptor, such as
There is an adaptor (p/n 1000-766 pictured below) the one pictured can be used for this. The yellow
that will adapt your mains lead on your PAT tester plug connects into the extension lead, while the
so you can plug it into 110 V supply. So, with the black IEC socket links back into the tester.
PAT300s and 400s, you can just plug the fixed
mains lead into this adaptor, then into the 110 V
supply. The PAT4DV/3, you have the option of
buying the 110 V mains lead (p/n 6220-631) or
using the adaptor.

Testing 110V Transformers

110 V transformers plug into 230 V supply,


therefore can be tested under a 230 V test group
code that are pre-programmed into many of the
Megger PAT testers. Typical tests for transformers
Testing Procedures would include a visual inspection, earth bond test
and an insulation resistance test.
A visual inspection is the most important part of When performing an earth bond test, you would
inspecting and testing appliances, and it is not any normally connect the bond probe into the earth pin
different when testing 110 V appliances. Tests that of the 110 V socket.
should be performed on 110 V appliances would The insulation test can be performed using a 500 V
include an earth bond test and an insulation test at DC test voltage, due to being supplied by 230 V.
250 V. An operation/load test and leakage test can
also be performed.
Care should be taken when performing an operation
or leakage test, as this will power up the appliance. A
lot of the time 110 V appliances are hand tools,
which if care is not taken, could potentially harm
once powered up.

CERTIFICATION ISO
UK UNITED STATES OTHER TECHNICAL SALES OFFICES
Registered to ISO 9001:2008 Cert. no. Q 09250
Archcliffe Road Dover 4271 Bronze Way Valley Forge USA, College Station USA, Sydney Registered to ISO 14001-2004 Cert. no. EMS 61597
CT17 9EN England Dallas TX 75237-1019 USA AUSTRALIA, Täby SWEDEN, Ontario CANADA,
T +44 (0) 1304 502101 T 800 723 2861 (USA only) Trappes FRANCE, Oberursel GERMANY, Aargau 110V Appliances _AN_en_V01
F +44 (0) 1304 207342 T +1 214 333 3201 SWITZERLAND, Kingdom of BAHRAIN, Mumbai www.megger.com
UKsales@megger.com F +1 214 331 7399 INDIA, Johannesburg SOUTH AFRICA, Chonburi Megger is a registered trademark
USsales@megger.com THAILAND

You might also like