You are on page 1of 2

Variable Frequency Drive - Energy Savings Estimator 062010

Irrigator Name and Address Utility Name and Acct No

When beginning
Scooby Do Farms Nice Cooperative a new analysis,
Wally World, WA Meter # begin with a
"clean sheet".
Management inputs Selected or Existing Pump Erasing all data
Manufacturer Type Model Pump RPM from a sheet
Existing may result in
System flow Gross Calc Annual Franklin Centrifugal 86CCP14 1,780
errors.
Field size rate irrigation Operating Base pump curve (60 Hz)
(irrig ac) (gpm) applied (in/yr) Hours Point Flow (gpm) Head (ft) Efficiency (%)
500 2300 18 1,771 1 1250 215 60
Annual Usage 150,000 kWh/yr 2 1750 205 73
3 2000 200 78
Motor assumptions Costs 4 2250 190 83
5 2500 185 86
VFD Average Cost Installed 6 2750 180 86
Motor Efficiency per kWh Cost VFD 7 3000 170 85
Efficiency (%) (%) ($) ($) 8 3250 160 83
90 95 $0.06 $19,500 9
Motor HP 125 nameplate HP 10
Calc Op Hrs 1787 Compare to above hrs 11

Operating points/ system curve without VFD Operating points/System curve with VFD

Pump
Efficiency Head Reqs VFD freq Pump
Point Flow (gpm) Head (ft) (%) Flow (gpm) (ft) (Hz) Efficiency (%)
1 750 226 45 750 150 49.3 50
2 1,500 212 67 1500 150 51.4 73
3 2,250 192 83 2250 160 55.4 85
4 2,800 177 86 2800 170 59.1 86
5 3,000 171 86 3000 170 60.0 86
6

Operating points/ system curve without VFD Operating points/System curve with VFD
Point %Hrs Input-HP KWh VFD freq (Hz) Input-HP %Hrs KWh
1 10% 107 14,073 49.3 67 10% 8,817
2 30% 133 52,796 51.4 91 30% 35,999
3 30% 146 58,032 55.4 125 30% 49,726
4 20% 161 42,613 59.1 163 20% 43,043
5 10% 168 22,217 60.0 176 10% 23,256
6

Efficiency (%)
60 Hertz Base pump curve
175 12
Head in ft

170 10
60 hz
165
57 HZ 8
160
150
150 6
155
4
150

145 2

140 0
500 1000 1500 2000 2500 3000 3500
Flow in gpm

With out VFD With VFD


Annual Power Cost/season Annual Power Cost/season Energy Savings Power Savings Payback
use (KWH) ($) use (KWH) ($) (kWh/yr) ($/yr) (yrs)
189,731 $11,383.88 160,841 $9,650.43 28,891 $1,733 11.2
Pump Curves for Various Frequency Speeds and Specified Operating Points
175

60
HZ
170 55
HZ
Total head in ft

50
HZ
40
165 HZ
35
HZ
Ctrl
pt 1
160
Ctrl
pt 2
Ctrl
pt 3
155 Ctrl
pt 4
Ctrl
pt 5
Ctrl
150 pt 6
Slid
er
73%
eff
145 78%
eff
83%
eff
86%
140 eff
0 500 1000 1500 2000
Flow in gpm 2500 3000 3500

You might also like