You are on page 1of 10

OPTION 2 Slaughtering Area

WIND LOAD CALCULATION

Directional Procedure for Buildings of All Heights

Occupancy Category: IV-Standard Occupancy Category (Table 103-1)

Basic Wind Speed: V=250 kph (Fig. 207A.5-1A)

WIND LOAD PARAMETERS:

Wind Directionality Factor: Kd=0.85 (Table 207A.6-1)

Exposure Category: Exposure C (Sec. 207A.7.3)

Topographic Factor: Kzt=1.0 (Sec. 207A.8.2)

Gust Effect Factor: G=0.85 (Sec. 207A.9.1)

Enclosure Classification: Enclosed Structure (Sec. 207A.10)

Internal Pressure Coefficient: GCpi = ±0.18 (Table 207A.11-1)

Velocity Pressure Exposure Coefficient: Kz=0.99 (Table 207B.3-1)

Velocity Pressure:

𝑁 𝑚
𝑞𝑧 = 0.613𝐾𝑧𝐾𝑧𝑡𝐾𝑑𝑉 2 ( 2 ) ; 𝑉 𝑖𝑛
𝑚 𝑠

𝑞𝑧 = 0.613(0.99)(1.0)(0.85)(72.2222)2

𝒒𝒛 = 𝟐𝟔𝟗𝟎. 𝟔𝟒𝟒𝟑 𝑵⁄𝒎𝟐


External Pressure Coefficient: (Fig. 207B.4-1)

Wall Pressure Coefficients, Cp

𝐿 39 𝑚
 = 40 𝑚 = 0.975
𝐵

Surface Cp

Windward Wall 0.8

Leeward Wall -0.5

Side Wall -0.7

Roof Pressure Coefficient, Cp

Surface Cp

Windward Roof -0.6811

-0.1629

Leeward Roof -0.3189

1
 ℎ = 5.5 𝑚 + 2 (4 𝑚) = 7.5 𝑚

ℎ 7.21 𝑚
 = = 0.206
𝐿 35 𝑚

4𝑚
 𝜃 = tan−1 (20.5 𝑚) = 11.0409°

𝑁
𝑝 = 𝑞𝐺𝐶𝑝 − 𝑞𝑖(𝐺𝐶𝑝𝑖) (𝑚2 ) (Eqn. 207B.4-1)

WALL PRESSURE

Windward Wall
𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(0.80) − 2690.6443 𝑁⁄𝑚2 (0.18)

𝑝 = 1345.3222 𝑃𝑎 = 1.3453 𝑘𝑃𝑎

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(0.80) − 2690.6443 𝑁⁄𝑚2 (−0.18)

𝑝 = 2313.9541 𝑃𝑎 = 𝟐. 𝟑𝟏𝟒𝟎 𝒌𝑷𝒂

Leeward Wall

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.50) − 2690.6443 𝑁⁄𝑚2 (0.18)

𝑝 = −1627.8398 𝑃𝑎 = −𝟏. 𝟔𝟐𝟕𝟖 𝒌𝑷𝒂

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.50) − 2690.6443 𝑁⁄𝑚2 (−0.18)

𝑝 = −659.2079 𝑃𝑎 = −0.6592 𝑘𝑃𝑎

Side Wall

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.70) − 2690.6443 𝑁⁄𝑚2 (0.18)

𝑝 = −2085.2493 𝑃𝑎 = −𝟐. 𝟎𝟖𝟓𝟑 𝒌𝑷𝒂

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.70) − 2690.6443 𝑁⁄𝑚2 (−0.18)

𝑝 = −1116.6174 𝑃𝑎 = −1.1166 𝑘𝑃𝑎

ROOF PRESSURE

Windward Roof with Cp = -0.6584

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.6584) − 2690.6443 𝑁⁄𝑚2 (0.18)


𝑝 = −1990.0221 𝑃𝑎 = −𝟏. 𝟗𝟗𝟎𝟎 𝒌𝑷𝒂

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.6584) − 2690.6443 𝑁⁄𝑚2 (−0.18)

𝑝 = −1021.3902 𝑃𝑎 = −1.0214 𝑘𝑃𝑎

Windward Roof with Cp = -0.1425

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.1425) − 2690.6443 𝑁⁄𝑚2 (0.18)

𝑝 = 810.2801 𝑃𝑎 = −0.8103 𝑘𝑃𝑎

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.1425) − 2690.6443 𝑁⁄𝑚2 (−0.18)

𝑝 = 158.3519 𝑃𝑎 = 𝟎. 𝟏𝟓𝟖𝟒 𝒌𝑷𝒂

Leeward Roof

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.3416) − 2690.6443 𝑁⁄𝑚2 (0.18)

𝑝 = −1265.6575 𝑃𝑎 = −𝟏. 𝟐𝟔𝟓𝟕 𝒌𝑷𝒂

𝑝 = 2690.6443 𝑁⁄𝑚2 (0.85)(−0.3416) − 2690.6443 𝑁⁄𝑚2 (−0.18)

𝑝 = −297.0255 𝑃𝑎 = −0.2970 𝑘𝑃𝑎


OPTION 2 Slaughtering Area

WIND LOAD CALCULATION

C&C Wind Loads Enclosed Low-rise Buildings

(Simplified Method)

Occupancy Category: IV-Standard Occupancy Category (Table 103-1)

Basic Wind Speed: V=250 kph (Fig. 207A.5-1A)

WIND LOAD PARAMETERS:

Exposure Category: Exposure C (Sec. 207A.7.3)

Topographic Factor: Kzt=1.0 (Sec. 207A.8.2)

𝑆𝑝𝑎𝑐𝑖𝑛𝑔 𝑜𝑓 𝑇𝑟𝑢𝑠𝑠 = 2.5 𝑚

𝑇𝑟𝑢𝑠𝑠 𝐸𝑓𝑓𝑒𝑐𝑡𝑖𝑣𝑒 𝐴𝑟𝑒𝑎 = (2.5 𝑚)(41 𝑚) = 102.5 𝑚2

1 1
𝑀𝑖𝑛𝑖𝑚𝑢𝑚 𝑆𝑝𝑎𝑐𝑖𝑛𝑔 𝑜𝑓 𝑃𝑢𝑟𝑙𝑖𝑛𝑠 = × 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 𝑜𝑓 𝑡𝑟𝑢𝑠𝑠 = (2.5 𝑚) = 0.8333 𝑚
3 3

𝑃𝑢𝑟𝑙𝑖𝑛 𝐸𝑓𝑓𝑒𝑐𝑡𝑖𝑣𝑒 𝐴𝑟𝑒𝑎 = 2.5 𝑚(0.8333 𝑚) = 2.1 𝑚2

𝑅𝑜𝑜𝑓 𝑂𝑣𝑒𝑟ℎ𝑎𝑛𝑔 = 1 𝑚

𝑅𝑜𝑜𝑓 𝑂𝑣𝑒𝑟ℎ𝑎𝑛𝑔 𝐸𝑓𝑓𝑒𝑐𝑡𝑖𝑣𝑒 𝐴𝑟𝑒𝑎 = 1 𝑚 (2.5 𝑚) = 2.5 𝑚2


Wind Pressures, 𝑝𝑛𝑒𝑡9 (Fig. 207E.5-1)

2𝑚
𝜃 = tan−1 ( ) = 5.5722°
20.5 𝑚

By Interpolation:

Purlin

Zone 1 1.0853 -1.8477

Zone 2 1.0853 -3.0283

Zone 3 1.0853 -4.5560

Truss

Zone 1 0.85 -1.72

Zone 2 0.85 -2.44

Zone 3 0.85 -3.83

Roof Overhang

Zone 2 -3.2322

Zone 3 -3.8767

Adjustment Factor: 𝜆 = 1.35 (Fig. 207F.5-1)

Adjusted Wind Pressures:

𝑝𝑛𝑒𝑡 = 𝜆𝐾𝑧𝑡𝑝𝑛𝑒𝑡9 (Eqn. 207E.5-1)

Purlin
Zone 1 1.4652 -2.4944

Zone 2 1.4652 -4.0883

Zone 3 1.4652 -6.1506

Truss

Zone 1 1.1475 -2.1702

Zone 2 1.1475 -3.2940

Zone 3 1.1475 -5.1705

Roof Overhang

Zone 1 -4.3635

Zone 2 -5.2335
OPTION 2 Holding Pens

WIND LOAD CALCULATION

C&C Wind Loads Enclosed Low-rise Buildings

(Simplified Method)

Occupancy Category: IV-Standard Occupancy Category (Table 103-1)

Basic Wind Speed: V=250 kph (Fig. 207A.5-1A)

WIND LOAD PARAMETERS:

Exposure Category: Exposure C (Sec. 207A.7.3)

Topographic Factor: Kzt=1.0 (Sec. 207A.8.2)

𝑆𝑝𝑎𝑐𝑖𝑛𝑔 𝑜𝑓 𝑇𝑟𝑢𝑠𝑠 = 3 𝑚

𝑇𝑟𝑢𝑠𝑠 𝐸𝑓𝑓𝑒𝑐𝑡𝑖𝑣𝑒 𝐴𝑟𝑒𝑎 = (3 𝑚)(20 𝑚) = 60 𝑚2

1 1
𝑀𝑖𝑛𝑖𝑚𝑢𝑚 𝑆𝑝𝑎𝑐𝑖𝑛𝑔 𝑜𝑓 𝑃𝑢𝑟𝑙𝑖𝑛𝑠 = × 𝑠𝑝𝑎𝑐𝑖𝑛𝑔 𝑜𝑓 𝑡𝑟𝑢𝑠𝑠 = (3 𝑚) = 1 𝑚
3 3

𝑃𝑢𝑟𝑙𝑖𝑛 𝐸𝑓𝑓𝑒𝑐𝑡𝑖𝑣𝑒 𝐴𝑟𝑒𝑎 = 3 𝑚(1 𝑚) = 3 𝑚2

𝑅𝑜𝑜𝑓 𝑂𝑣𝑒𝑟ℎ𝑎𝑛𝑔 = 1 𝑚

𝑅𝑜𝑜𝑓 𝑂𝑣𝑒𝑟ℎ𝑎𝑛𝑔 𝐸𝑓𝑓𝑒𝑐𝑡𝑖𝑣𝑒 𝐴𝑟𝑒𝑎 = 1 𝑚 (3 𝑚) = 3 𝑚2


Wind Pressures, 𝑝𝑛𝑒𝑡9 (Fig. 207E.5-1)

1𝑚
𝜃 = tan−1 ( ) = 5.7106°
10 𝑚

By Interpolation:

Purlin

Zone 1 1.0340 -1.8220

Zone 2 1.0340 -2.90

Zone 3 1.0340 -4.4020

Truss

Zone 1 0.85 -1.72

Zone 2 0.85 -2.44

Zone 3 0.85 -3.83

Roof Overhang

Zone 2 -3.2322

Zone 3 -3.8767

Adjustment Factor: 𝜆 = 1.35 (Fig. 207F.5-1)

Adjusted Wind Pressures:

𝑝𝑛𝑒𝑡 = 𝜆𝐾𝑧𝑡𝑝𝑛𝑒𝑡9 (Eqn. 207E.5-1)

Purlin
Zone 1 1.3959 -2.4597

Zone 2 1.3959 -3.9150

Zone 3 1.3959 -5.9427

Truss

Zone 1 1.1475 -2.1702

Zone 2 1.1475 -3.2940

Zone 3 1.1475 -5.1705

Roof Overhang

Zone 1 -4.3635

Zone 2 -5.2335

You might also like