Professional Documents
Culture Documents
Snap-on
Graphing Scanner Comparison
We are glad to see the guy down the street finally went
out and got a color display. However, a color display with
limited graphing capability does not equal “me too” when
compared with the overall power of the Genisys. Below is
a chart comparing the Snap-on MTG2500 with Genisys
Pathfinder 2001. As proven below, there is not a scan tool
on the market even close to the power of Genisys. The
best just got better with the release of Pathfinder 2001
“Mega Release.”
Graphing feature completely Yes Yes Graphing of data back 20 years is just
compatible with previous one of the exciting features in the
software titles Pathfinder “Mega Release!”
Dynamic Min/Max capture Yes Yes Genisys has more powerful Min, Max, &
as an indicator of possible live data graphing features, plus Freeze
data glitch Frame glitch capture.
Graph data from 1980 – 1995 Yes Yes, Genisys 92 – 01 graphs are embedded
domestic vehicles S/W - earlier with cartridge graphing.
Graph data from 1983 – 1995 Yes Yes, Genisys 96 – 00 graphs are embedded
Asian import vehicles S/W - earlier with cartridge graphing.
Graph non-OBD II vehicles Yes Yes Again, yes. Genisys graphs non-OBD II
vehicles.
01-73 (11/01)
Printed in USA
OTC Genisys delivers software solutions!
Magnify feature available to No Yes Genisys magnify window will scroll along
all graphed data displayed the graphed data line, providing detailed
analysis at any point.
Display graphs and No Yes Genisys can mix graphs and digital to
digital data on screen provide maximum diagnostic flexibility.
simultaneously
Code Trigger recording and No Yes Code Trigger recording is always on.
saving of up to 25 files When a code trips, Genisys saves 74
frames before the code, one when the
code tripped, and 75 after to Playback.
Provides a picture of the No Yes Genisys identifies cables using part num-
vehicle cable to use ber, description, and a picture.
Live digital reading in Graph No Yes Genisys offers Min, Max, and live digital
Mode data even in Graph Mode.
Freeze frame data storage No Yes Press the left arrow on Genisys to
freeze live data and begin viewing –
press the Record key to save the file
to Playback.
Lock saved recorded files No Yes Genisys will let you lock saved files so
they will not be overwritten.
Bulletin Board Service (BBS) No Yes BBS provides updates via an analog
updateable phone line and modem.
RAM 32 KB 16 MB upgrade-
able to 64 MB
Refresh rate data monitor Slower 4X per second Genisys does not miss any critical data.
graph mode (approx.) (.25 per Sec.)