Professional Documents
Culture Documents
2 • 2003/2004
micromaster
MICROMASTER 410/420/430/440
Inverters
0.12 kW to 250 kW
Other catalogs for “Standard Drives“
SIVOLT A/V DA 68
Alternating current and three-
phase current controller
Order No.:
German: E20002-K4068-A101-A1
Low-Voltage Motors M 11
Order No.:
German: E86060-K1711-A101-A3
English: E86060-K1711-A101-A3-7600
Order No.:
German: E86060-D4001-A100-C1
English: E86060-D4001-A110-C1-7600
On CD 2 of the selection and configuration aids you will find the SD
A&D Mall configurator for low-voltage motors, MICROMASTER 4 inverters and
SINAMICS G110 including:
Internet • Dimension drawing generator for motors
http://www.siemens.com/automation/mall
• Data sheet generator for motors
• Starting calculation
• 3D models in .stp format
• Extensive documentation
Hardware and software requirements
• PC with Pentium II or comparable processor
• Operating systems
– Windows 98/ME
– Windows 2000
– Windows XP
– Windows NT
(Service Pack 5 upwards)
• Minimum of 128 RAM
• 1024 x 768 graphics with more than 256 colors / small fonts
• CD-ROM drive
• Windows-compatible sound card
• Windows-compatible mouse
Installation
You can install this catalog directly from the CD-ROM as a complete
or partial version on your hard disk or in the network.
Hotline:
For technical advice and hotline support concerning our CA 01
catalog:
Tel.: +49 (0) 180 50 50 22 2
E-Mail: adsupport@siemens.com
Trademarks
0.12 kW to 250 kW
Catalog DA 51.2
2003/2004 MICROMASTER 410
“The low-priced”
0.12 kW to 0.75 kW
Supersedes:
Catalog DA 51.2 · 2002
1
The products in this catalog are also included
in the CD-ROM catalog CA 01.
Order No.:
E86060-D4001-A110-C1-7600
MICROMASTER 420 0.12 kW to 11 kW
Contact your local Siemens representative
for further information “The universal”
© Siemens AG 2003
2
3
The products and sys-
tems described in this
catalog are manufac-
tured under application
of a certified quality
management system in MICROMASTER 440 0.12 kW to 250 kW
accordance with DIN
“The all-purpose”
EN ISO 9001 (Certifi-
cate Registration No.
DE-000357 QM).
The certificate is recog-
nized in all IQNet coun-
tries.
4
Appendix Certificates/Standards
Demonstration case/
Training
s
Overview of motors and
inverters
Siemens contacts
Online services
A
Service & Support
Conditions of sale and
delivery
Export regulations
Welcome to
Automation and Drives
worldwide.
potential.
0 Overview
■ Selection guide
Section 1 Section 2
0/4 Siemens DA 51.2 · 2003/2004
MICROMASTER 410/420/430/440
Overview 0
Section 3 Section 4
Siemens DA 51.2 · 2003/2004 0/5
MICROMASTER 410/420/430/440
0 Overview
■ Options
Various options are available Assignment of operator panels and modules to the inverter ranges
for the MICROMASTER
inverters: Options Order No. MICROMASTER
410 420 430 440
■ Filters
■ Chokes Operator panels
■ Operator panels OP 6SE6400-0SP00-0AA0 %
■ PROFIBUS module BOP 6SE6400-0BP00-0AA0 % %
■ DeviceNet module BOP-2 6SE6400-0BE00-0AA0 %
■ CANopen module AOP 6SE6400-0AP00-0AA1 % %
■ Pulse encoder evaluation AAOP 6SE6400-0AP00-0AB0 % %
module
Modules
■ Gland plates
PROFIBUS 6SE6400-1PB00-0AA0 % % %
■ Mounting kits, etc.
DeviceNet 6SE6400-1DN00-0AA0 % % %
CANopen 6SE6400-1CB00-0AA0 % % %
Pulse encoder evaluation 6SE6400-0EN00-0AA0 %
% Possible combination
Operator panels
Modules
Description
Description
Circuit diagrams
I Fn 100 V to 120 V 1 AC
200 V to 240 V 1 AC
1 O Jog P
PE
6
+10 V
+ >
- 4.7 k AIN+ 7
A
-
8 D
max. 33 V
max. 5 mA AC
DIN1 1
DIN2 2
DIN3 3 DC
+
24 V 4 +24 V (max. 50 mA) DC+
-
5 DC -
0V
Voltage supply
CPU
(external or
internal source)
9 Serial
P+ inter-
10 face
N-
RS-485
PE U, V, W
A DA51-5033b
M
3~
DIN4 7
+
24 V 4
-
5
Voltage supply
(external or
internal source)
ADA51-5034b
Circuit diagrams
Mains connections
View A
Motor connections
View A
A DA51-5035a
Output relay
RL1
RL1-B RL1-C
11 12
1 2 3 4 5 6 7 8 9 10
RS-485
(USS protocol)
Analog input
Digital inputs Voltage
supply 24 V Voltage
supply 10 V
Technical data
1 Precharge current
Control method
Not higher than rated input current
Linear V/f characteristic; quadratic V/f characteristic; multipoint characteristic
(programmable V/f characteristic)
Pulse frequency 8 kHz (standard)/2 kHz to 16 kHz (in 2 kHz steps)
Fixed frequencies 3, programmable
Skip frequency ranges 1, programmable
Setpoint resolution 10 bit analog/0.01 Hz serial
Digital inputs 3 programmable digital inputs, non-floating, PNP, SIMATIC-compatible
Analog input 1, for setpoint (0 V to 10 V, scaleable or for use as 4th digital input)
Relay outputs 1, programmable, 30 V DC/5 A (resistive load); 250 V AC/2A (inductive load)
Serial interface RS-485, for operation with USS protocol
Motor cable lengths Max. 30 m (shielded)/max. 50 m (unshielded)
Electromagnetic compatibility Inverter available with internal EMC filter to EN 61 800-3 (defined limits to EN 55 011, Class B)
Braking DC braking, compound braking
Degree of protection IP20
Operating temperature –10 °C to +50 °C (+14 °F to +122 °F)
Storage temperature –40 °C to +70 °C (–40 °F to +158 °F)
Relative humidity 95 % (non-condensing)
Site altitude Up to 1000 m above sea level without derating
Protection features for Undervoltage, overvoltage, overload, earth faults, short circuits, stall prevention,
I2t motor thermal protection, inverter overtemperature
Typical power losses (heatsink) at 20 W (with 0.37 kW inverter with flat plate heatsink)
full load and maximum operating 37 W (with 0.75 kW inverter with flat plate heatsink)
temperature as specified
Line-side and control electronics 18 W (with 0.37 kW inverter with flat plate heatsink)
losses (at 230 V, 50 Hz, 8 kHz) 34 W (with 0.75 kW inverter with flat plate heatsink)
Recommended thermal resistance 1.8 K/W (with 0.37 kW inverter with flat plate heatsink)
of heatsink 1.2 K/W (with 0.75 kW inverter with flat plate heatsink)
Compliance with standards u, cu (not for versions with flat plate heatsink)
>, c-tick ●
✔
> marking Conformity with low-voltage directive 73/23/EC
Dimensions and weights (without Frame size (FS) H x W x D (mm) Weight, approx. (kg)
options) AA 150 x 69 x 118 0.8
AB 150 x 69 x 138 1.0
0.37 kW inverter with flat plate heatsink 175 x 69 x 102 0.78
0.75 kW inverter with flat plate heatsink 175 x 69 x 102 0.8
■ Derating data
Pulse frequency
The current data apply to an ambient temperature of 50 °C/122 °F unless specified otherwise.
Technical data
ADA51-5039a ADA51-5038a
100 100
Mains voltage
Rated output current
90 %
80 80
%
60
75
60
1
40 40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
The current data apply to an ambient temperature of 50 °C/122 °F 1) The values apply to rated mains voltages of 115 V or 230 V.
unless specified otherwise.
2) Generally suited to heavy industrial applications.
For details please refer to Appendix on page A/4.
■ Overview
EMC filter, Class B A non-filtered inverter together power is less than 1 %, a line For devices with 250 W and
with the optional filter “Filter commutating choke must be 370 W, it is necessary either to
Variants with internal EMC fil-
Class B with low leakage cur- used in order to reduce the fit the recommended input
ter Class B are available for in-
rents” has a leakage current current peaks. chokes or to apply to the pow-
verters with a mains operating
3.5 mA (shielded motor er utility company for authori-
voltage of 1 230 V AC. The line commutating chokes
cable up to 5 m). zation to connect the devices
are designed as footprint
• The requirements are satis- to the public power supply.
chokes and are fitted between
fied using: shielded cables Line commutating choke No limits are currently defined
the inverter and the mounting
with a max. length of 5 m, or in the EN 61 000-3-2 standard
1 10 m with a low-capacitance
Line commutating chokes are
used to smooth voltage peaks
plate.
for professionally used devic-
motor cable (core/core In line with EN 61 000-3-2 reg- es with a connected load
or to bridge commutating
< 75 pF/m, core/shield ulations ”Limits for harmonic > 1 kW, which means that the
dips.
< 150 pF/m). The limits com- currents with device input cur- inverters with an output power
ply with EN 55 011 Class B. In addition, line commutating rent 16 A per phase”, there 0.75 kW comply with the
chokes reduce the effects of are special aspects for drives EN 61 000-3-2 standard.
An inverter with internal filter
harmonics on the inverter and with 250 W to 550 W and 230 V
can be used with a 30 mA re-
the power supply. single-phase supplies which
sidual current operated cir-
can be used in non-industrial
cuit-breaker, and is only suit- If the ratio of inverter rated
applications (1st environ-
able for hardwired installation. power to mains short-circuit
ment).
*) With these inverters, the filter or choke cannot be mounted in the substructure. This option must be mounted upright.
■ Overview
Operator Panel (OP) Connection kit for Start-up tools
PC to inverter
With the OP, individual param- • STARTER
eter settings can be made. For controlling and commis- is a graphic start-up soft-
sioning an inverter directly ware for guided start-up for
Values and units are shown on
from a PC if the appropriate MICROMASTER 410/420/
a 5-digit display.
software has been installed 430/440 frequency inverters
An OP can be used for several (e.g. STARTER). under Windows NT/2000/
inverters. It is directly plugged XP Professional. Parameter
The connection kit includes
into the inverter.
an RS-485/RS-232 interface
converter with a 9-pin Sub-D
lists can be read out, al-
tered, stored, entered and 1
printed.
connector.
• DriveMonitor
is a start-up software for list-
oriented programming of
frequency inverters. This
program executes under
Windows 95/98/NT/2000/
XP Professional.
Documentation
Dimension drawings
(0.47)
Ø 4.5
(0.47)
12
Ø 4.5 12 (0.18) Ø 4.5
34.5 (0.18)
(0.18) (1.36)
ADA51-5037a
A DA51-5036a
160 (6.30)
160 (6.30)
175 (6.89)
163 (6.44)
1
150 (5.9)
150 (5.9)
G_DA51_EN_05073
(5 138
(4 118
3)
5)
.4
.6
(4 102
2)
.0
69 69 69
(2.72) (2.72) (2.72)
Inverter frame size AA Inverter frame size AB Inverter with flat plate heatsink
6SE6410-2 . . 11-2AA0 6SE6410-2 . . 15-5BA0 6SE6410-2 . B13-7AB0
6SE6410-2 . . 12-5AA0 6SE6410-2 . . 17-5BA0 6SE6410-2 . B17-5BB0
6SE6410-2 . . 13-7AA0
All dimensions in mm (values in brackets are in inches)
73 (2.87)
23.5 50
(0.93) 56 (2.2) 50 (1.97) 150 (5.91)
(1.97) 75.5 (2.97)
2 x M4
174 (6.85)
187 (7.36)
200 (7.87)
G_DA51_EN_05104
160 (6.3)
213 (8.39)
200 (7.87)
G_DA51_EN_05105
ADA51-5010e
42.5 (1.67)
Footprint chokes
Filter 6SE6400-3CC00-4AB3 Choke for upright mounting
6SE6400-2FL01-0AB0 6SE6400-3CC01-0AB3 6SE6400-3CC02-6BB3
2/9 Options
Description
Description
Circuit diagrams
O p e r a to r p a n e l ( O p tio n )
2 0 0 V to 2 4 0 V 1 /3 A C
3 8 0 V to 4 8 0 V 3 A C
P E
V o lta g e s u p p ly a n d F S 1
a n a lo g in p u t
In p u t v o lta g e : 0 V to + 1 0 V , P E L , N (L 1 , L 2 )
s c a la b le o r
L 1 , L 2 , L 3
1 + 1 0 V
2 0 V
+
-> 4 . 7 k 9 A IN + 3 A
-
A IN - 4
D
2 m a x . 3 3 V
m a x . 5 m A A C
D IN 1 5
D IN 2 6
D IN 3 7 D C
+
2 4 V 8
- + 2 4 V (m a x .1 0 0 m A )
9 D C L in k
0 V ( is o la te d )
V o lta g e C P U
s u p p ly
R L 1
O u tp u t re la y c o n ta c ts D C
2 5 0 V A C , m a x . 2 A 1 0
R L 1 -B
( in d u c tiv e lo a d ) 1 1
3 0 V D C , m a x . 5 A R L 1 -C
(re s is tiv e lo a d ) A C
A n a lo g o u tp u t 1 2 A
A O U T +
0 m A to 2 0 m A 1 3
A O U T - D
W h e n a c o m m u n ic a tio n s 1 4 S e r ia l
P + in te r -
m o d u le is c o n n e c te d , th e 1 5
N - fa c e
s e r ia l in t e r f a c e d o e s n 't w o r k . R S -4 8 5
P E U , V , W
A D A 5 1 -5 0 0 3 i
M
3 ~
2
0V
DIN4 3
4
+
24 V
-
9
0 V (isolated)
ADA51-5004e
Circuit diagrams
View A
DC link
terminals
Mains
connections
Motor
connections
2
View A
AOUT+ AOUT- P+ N-
12 13 14 15
Output relay
RL1
Analog output RS-485
(USS protocol)
5 6 7 8 9 10 11
1 2 3 4
Technical data
2 Relay outputs
Analog output
1, programmable, 30 V DC/5 A (resistive load); 250 V AC/2A (inductive load)
1, programmable (0 mA to 20 mA)
Serial interfaces RS-485, optional RS-232
Motor cable lengths
without output choke max. 50 m (shielded)
max. 100 m (unshielded)
without output choke (see variant dependent options)
Electromagnetic compatibility Inverter available with internal EMC filter Class A;
available as options are EMC filters to EN 55 011, Class A or Class B
Braking DC braking, compound braking
Degree of protection IP20
Operating temperature –10 °C to +50 °C (+14 °F to +122 °F)
Storage temperature –40 °C to +70 °C (–40 °F to +158 °F)
Relative humidity 95 % (non-condensing)
Site altitude Up to 1000 m above sea level without derating
Protection features for • Undervoltage
• Overvoltage
• Overload
• Earth faults
• Short circuit
• Stall prevention
• Locked motor protection
• Motor overtemperature
• Inverter overtemperature
• Parameter interlock
Compliance with standards u, cu, >, c-tick ● ✔
> marking Conformity with low-voltage directive 73/23/EEC
Dimensions and weights Frame size (FS) H x W x D (mm) Weight, approx. (kg)
(without options) A 173 x 73 x 149 1.0
B 202 x 149 x 172 3.3
C 245 x 185 x 195 5.0
Technical data
■ Derating data
PWM frequency
Operating temperature
A D A 5 1 -5 0 1 7 e
1 0 0 2
R a te d o u tp u t c u rre n t
%
8 0
6 0
5 0
4 0
2 0
0
-1 0 0 1 0 2 0 3 0 4 0 5 0 6 0 °C 7 0
O p e r a tin g te m p e r a tu r e
100
Rated output current
%
80
60
40
20
0
0 1000 2000 3000 m 4000
Operational altitude
100
Mains voltage
%
80
77
60
40
20
0
0 1000 2000 3000 m 4000
Operational altitude
1) Supplementary conditions: without a line commutating 2) Use of MICROMASTER invert- 3) Generally suited to heavy
Input current at rated operating choke. If a line commutating ers with internal filter is not per- industrial applications. For
point, applicable at short- choke is used, the specified missible on non-grounded (IT) details please refer to Appen-
circuit voltage of the supply values at 200 V to 240 V are mains supplies. dix on page A/4.
Usc = 1 % with reference to the reduced to between 55% and
inverter rated power and rated 70% and 380 V – 480 V to
mains voltage of 240 V or 400 V between 70% and 80%.
■ Overview
EMC filter, Class A Filter Class B with low The LC filters can be used for In line with EN 61 000-3-2 reg-
leakage currents all MICROMASTER 420 invert- ulations “Limits for harmonic
Filter for inverters without an
ers of frame sizes A to C. currents with device input cur-
internal filter for EMC filter for 1 AC 200 V to
rent 16 A per phase”, there
– 3 AC 200 V to 240 V, 240 V inverters, frame sizes A • Frame sizes A and B:
are special aspects for drives
frame sizes A and B and B, without an internal EMC A maximum of two footprint
with 250 W to 550 W and
– 3 AC 380 V to 480 V, filter Class A. components plus inverter
230 V single-phase supplies
frame size A. are permissible. The LC filter
With this filter, the inverter which can be used in non-in-
must be mounted as the low-
All other inverters can be sup- complies with the emission dustrial applications (1st envi-
est component.
plied with an internal Class A standard EN 55 011, Class B. ronment).
filter. The leakage currents are re- • Frame size C:
For devices with 250 W and
duced to < 3.5 mA. Only one footprint compo-
The requirements are fulfilled 370 W, it is necessary either to
nent is permissible for frame
using shielded cables with a The requirements are fulfilled fit the recommended input
size C. If a line choke and
max. length of 25 m. using shielded cables with a chokes or to apply to the pow-
LC filter are used, the line
max. length of 5 m. er utility company for authori-
choke must be located on
EMC filter, Class B zation to connect the devices
Leakage currents: the left of the inverter. Re-
to the public power supply.
Filter for inverters without an quired spacing: 75 mm.
The leakage currents of the in- No limits are currently defined
internal filter for verters with/without filter (inter- Please note when using in the EN 61 000-3-2 standard
– 3 AC 200 V to 240 V, nal/external) may exceed LC filters: for professionally used devic-
frame sizes A and B 30 mA. Typical values in prac- es with a connected load
• Only V/f, FCC control per-
– 3 AC 380 V to 480 V,
frame size A.
tice are between 10 mA and
50 mA. The exact values de-
missible
> 1 kW which means that the
inverters with an output power
2
• Increased inverter load: ap-
pend on the design, environ- 0.75 kW comply with the
With this filter, the inverter prox. 10 % to 15 %
ment and cable lengths. Inter- EN 61 000-3-2 standard.
complies with the emission • Operation only permissible
ference-free operation with re-
standard EN 55 011, Class B. with 4 kHz pulse frequency
sidual current operated devic- Output choke
• The output frequency is lim-
The requirements are fulfilled es with a trigger value of
ited to 150 Hz. Output chokes can be sup-
using shielded cables with a 30 mA cannot be guaranteed.
plied for reducing the capaci-
max. length of 25 m. However, operation with resid-
Line commutating choke tive currents and dV/dt in the
ual current circuit-breakers
case of motor cables > 50 m
Additional EMC filter, with a trigger value of 300 mA Line commutating chokes
(shielded) or > 100 m (un-
Class B is possible. Please refer to the are used to smooth voltage
shielded).
Instruction Manual for details. peaks or to bridge commutat-
Available for inverters with an ing dips. In addition, line com- For max. permissible cable
internal Class A EMC filter. LC filter mutating chokes reduce the lengths, see Technical Data.
With this filter, the inverter effects of harmonics on the in-
The LC filter limits the rate of
complies with the emission verter and the power supply. If Gland plate
rise of voltage and the capac-
standard EN 55 011, Class B. the line impedance is <1 %, a
itive charge/discharge cur- The gland plate facilitates the
line commutating choke must
The requirements are fulfilled rents which usually occur with shield connection of power
be used in order to reduce the
using shielded cables with a inverter operation. This means and control cables and ensure
current peaks.
max. length of 25 m. that much longer shielded mo- optimum EMC performance.
tor cables are possible when
using LC filters and the ser-
vice life of the motor achieves
values similar to those with di-
rect mains operation.
■ Technical data
LC filter
Max. permissible cable lengths from the motor to the inverter when using output chokes
The following table shows the
maximum permissible cable
lengths from the motor to the
inverter when using output
chokes.
Frame size Output choke Max. permissible motor cable lengths (shielded/unshielded)
for a mains voltage of
(FS) Type 200 V to 240 V ± 10 % 380 V to 400 V ± 10 % 401 V to 480 V ± 10 %
A 6SE6400-3TC00-4AD3 200 m/300 m – –
A 6SE6400-3TC00-4AD2 200 m/300 m 150 m/225 m 100 m/150 m
B 6SE6400-3TC01-0BD3 200 m/300 m 150 m/225 m 100 m/150 m
C 6SE6400-3TC03-2CD3 200 m/300 m 200 m/300 m 100 m/150 m
■ Overview
Basic Operator Panel (BOP) Asian Advanced Operator DeviceNet module Connection kit for PC
Panel (AAOP) to AOP
With the BOP, individual pa- For networking the inverters to
rameter settings can be made. The AAOP is the Chinese ver- the DeviceNet fieldbus system For connecting a PC to an
Values and units are shown on sion of the AOP operator pan- widely used on the American AOP or AAOP. Offline pro-
a 5-digit display. el. It has an enhanced display market. A maximum transmis- gramming of inverters and ar-
and supports the operating sion rate of 500 Kbaud is pos- chiving of parameter kits pos-
languages of Chinese (simpli- sible. Remote control of the in- sible. Includes a desktop at-
fied) and English. verter is possible with the De- tachment kit for an AOP or
viceNet module. Remote con- AAOP, an RS-232 standard
trol and operation at the invert- cable (3 m) with Sub-D con-
er can be combined using an nectors and a universal power
operator panel plugged onto supply unit.
the DeviceNet module.
Operator panel door mount-
The connection to the De-
ing kit for single inverter
viceNet bus system is made
using a 5-pin connector with For mounting an operator pan-
terminal strip. el in a control cabinet door.
Degree of protection IP56.
CANopen module Contains a cable adapter
Basic Operator Panel (BOP)
module with screwless termi-
Using the CANopen commu-
nals for use with user’s own
2 A BOP can be used for several
inverters. It can be directly Asian Advanced Operator Panel
nications module, an inverter
can be linked to the CANopen
RS-232-cables 1).
(AAOP) fieldbus system and remote
mounted on the inverter or in a AOP door mounting kit for
control cabinet door using a control is then possible.
multiple inverters (USS)
mounting kit. PROFIBUS module Remote control and operation
For mounting an AOP or AAOP
at the inverter can be com-
Advanced Operator Panel For a complete PROFIBUS in a control cabinet door.
bined using an operator panel
(AOP) connection with up to Degree of protection IP56. The
plugged onto the CANopen
12 Mbaud. Remote control AOP or AAOP can communi-
The AOP enables parameter module.
of the inverter is possible with cate with several inverters by
kits to be read out of the invert- the PROFIBUS module. Re- The module is connected to means of the RS-485 USS
er or to be written into the in- mote control and operation at the bus system through a protocol. The 4-pin connect-
verter (upload/download) Dif- the inverter can be combined 9-pin Sub-D connector. ing cable from the AOP or
ferent parameter kits can be using an operator panel AAOP to the RS-485 terminals
stored in the AOP. It has a plugged onto the PROFIBUS Connection kit for of the inverter and to the 24 V
plain text display with the pos- module. The PROFIBUS mod- PC to inverter user terminal strip is not
sibility of switching between ule can be supplied by an ex- included 2).
several languages. For controlling an inverter di-
ternal 24 V DC power supply
rectly from a PC if the appro-
and is thus also active when Start-up tools
priate software has been in-
the inverter is disconnected
stalled (e.g. STARTER). • STARTER
from the power supply.
Isolated RS-232 adapter mod- is a graphic start-up soft-
Connection by means of a ule for reliable point-to-point ware for guided start-up for
9-pin Sub-D connector (avail- connection to a PC. Includes a MICROMASTER 410/420/
able as an option). Sub-D connector and an 430/440 frequency inverters
RS-232 standard cable (3 m). under Windows NT/2000/XP
Professional. Parameter lists
can be read out, altered,
stored, entered and printed.
• DriveMonitor
is a start-up software for list-
oriented programming of
Advanced Operator Panel (AOP) frequency inverters. This
program executes under
Up to 30 inverters can be con- Windows 95/98/NT/2000/
trolled from an AOP via USS. It XP Professional.
can be directly mounted on
the inverter or in a control cab- Both programs are included
inet door using a mounting kit. on the Docu CD which is pro-
vided with every inverter.
2 Degree of protection
Degree of pollution
IP20
2 to IEC 60 664-1 (DIN VDE 0110/T1), no condensation permitted during operation
Strain resistance to IEC 60 068-2-6 (if module is installed correctly)
• Stationary Deflection 0.15 mm in the frequency range of 10 Hz to 58 Hz
Acceleration 19.6 m/s2 in the frequency range of 58 Hz to 500 Hz
• Transport Deflection 3.5 mm in the frequency range of 5 Hz to 9 Hz
Acceleration 9.8 m/s2 in the frequency range of 9 Hz to 500 Hz
Climatic category (during operation) 3K3 to DIN IEC 60 721-3-3
Cooling method Natural air cooling
Permissible ambient or cooling agent temperature
• Operation –10 °C to +50 °C (+14 °F to +122 °F)
• Storage –40 °C to +70 °C (–40 °F to +158 °F)
• Transport –25 °C to +70 °C (–13 °F to +158 °F)
Relative humidity
(permissible humidity rating)
• Operation 85 % (non-condensing)
• Storage and transport 95 %
Power supply The CAN bus is supplied from the inverter power supply
Data transmission rate 10, 20, 50, 125, 250, 500, 800 Kbaud and 1 Mbaud
Documentation
Dimension drawings
(2.28)
58
173 (6.81)
160 (6.29)
DIN Rail
ADA51-5000e
ADA51-5007c
147 (5.79)
195 (7.68)
Fixing with
2 x M4 bolts, 2 x M4 nuts, 2 x M4 washers,
(5 149
7)
ADA51-5008b
202 (7.95)
258 (10.16)
138 (5.43)
(6 172
Fixing with
7)
.7
Drill pattern
204 (8.03)
ADA51-5009b
245 (9.65)
ADA51-5002d
309 (12.16)
174 (6.85)
Fixing with
(7 195
8)
Dimension drawings
38 185 (7.28)
(1.5) 156 (6.14)
24 149 (5.87)
73 (2.87)
23.5 (0.94) 120 (4.72)
(0.93) 56 (2.2)
4 x M5
4 x M4
219 (8.62)
232 (9.13)
2 x M4
187 (7.36)
200 (7.87)
204 (8.03)
245 (9.65)
174 (6.85)
187 (7.36)
213 (8.39)
174 (6.85)
200 (7.87)
160 (6.3)
ADA51-5010e
ADA51-5011c
ADA51-5012c
42.5 (1.67) 49.5 (1.95)
138 174 54 (2.13)
(5.43) (6.85)
2
c b
c b
DA51-5013e
c b
c b
DA51-5049
Output choke
for frame size A For frame sizes B and C
6SE6400-3TC00-4AD2 6SE6400-3TC01-0BD3
6SE6400-3TC00-4AD3 6SE6400-3TC03-2CD3
Dimension drawings
■ LC filter
280 (11.02)
287 (11.3)
293 (11.53)
300 (11.81)
340 (13.38)
334 (13.15)
G_DA51_EN_05080
G_DA51_EN_05077
G_DA51_EN_05079
G_DA51_EN_05076
56 120
(2.2) (4.72)
174 (6.85)
320 (12.6)
335 (13.19)
382 (15.04)
G_DA51_EN_05078a
G_DA51_EN_05081
156 (6.14)
Dimension drawings
G_DA51_XX_05016c
Example:
2 Assembly of
inverter, filter and choke
If additional options are
required, they must be mounted
at the side.
3/10 Options
Description
Description
Circuit diagrams
3 8 0 to 4 8 0 V 3 A C
P E
F S 1
+ 1 0 V P E F o r a d d itio n a l d ig ita l in p u ts
B O P
1 S e r ia l L 1 , L 2 , L 3 (D IN 7 , D IN 8 ) e x te rn a l
P ro to c o l c o n n e c tio n s s h o u ld b e m a d e :
0 V
2
A IN 1 +
-> 4 , 7 k 9 A
3
1 1
A IN 1 - D
4 2 2
A IN 2 + A 3 1 0
1 0
D 4 1 1
A IN 2 - D IN 7 D IN 8
1 1
D IN 1
5 N o te s :
D IN 2 W h e n a n a n a lo g in p u t is
A C c o n fig u re d a s a d ig ita l in p u t
6
D IN 3 th e th re s h o ld v a lu e s a r e a s
O p to is o la tio n
fo llo w s :
7 D C
D IN 4 1 .7 5 V D C = o ff
3 .7 V D C = o n
8
D IN 5
A IN 1 : 0 V to 1 0 V , 0 m A to 2 0 m A
1 6 a n d -1 0 V to + 1 0 V
D IN 6 A IN 2 : 0 V to 1 0 V
1 7 a n d 0 m A to 2 0 m A
P N P O u tp u t + 2 4 V
( is o la te d )
o r 9
N P N O u tp u t 0 V
( is o la te d )
2 8
P T C A
3 M o to r
P T C /K T Y P T C B
1 4
A
D
1 5 C P U
A O U T 1 +
0 - 2 0 m A , A D C
1 2
m a x . 5 0 0 9 A O U T 1 - D
1 3
A C
A O U T 2 +
A
0 - 2 0 m A , 2 6
m a x . 5 0 0 9 A O U T 2 - D
2 7
R L 1
R L 1 - C 6 0 H z
2 0 N o t
R L 1 - B u s e d 5 0 H z
1 9 1 2
R L 1 - A D IP S w itc h e s
1 8
O u tp u t re la y R L 2 (o n C o n tro l B o a rd )
c o n ta c ts
2 5 0 V A C , m a x . 2 A R L 2 - C
2 2
( in d u c tiv e lo a d ) R L 2 - B
3 0 V D C , m a x . 5 A 2 1
( r e s is tiv e lo a d ) A IN 1 A IN 2
R L 3
0 - 2 0 m A
R L 3 - C
2 5 0 - 1 0 V
R L 3 - B
2 4 1 2
R L 3 - A D IP S w itc h e s
2 3 (o n I/O B o a rd )
W h e n a c o m m u n ic a tio n s
P +
m o d u le is c o n n e c te d , 2 9 R S 4 8 5
th e s e r ia l in te r fa c e
N -
d o e s n 't w o rk . 3 0 P E U , V , W
A D A 5 1 -5 0 4 8 c
M
3 ~
Circuit diagrams
View A
Mains connections
Motor connections
View A
AIN1 AIN2 RL1-A RL1-B RL1-C RL2-B RL2-C RL3-A RL3-B RL3-C
A DA51-5025
S1 S2
18 19 20 21 22 23 24 25
DIP Switches:
0 mA to 20 mA
or Output relay contacts
0 V to 10 V
3
AOUT1+ AOUT1- PTC PTC DIN5 DIN6 AOUT2+ AOUT2- PE P+ N-
A B 0V
12 13 14 18
15 16 17 26 27 28 29 30
NPN *)
(DIN7) (DIN8)
+10 V 0V AIN1+ AIN1- DIN1 DIN2 DIN3 DIN4 +24 V AIN2+ AIN2-
1 2 3 18
4 5 6 7 8 9 10 11
PNP *)
Technical data
Technical data
■ Derating data
Pulse frequency
Operating temperature
100 1 0 0
Rated output current
R a te d o u tp u t c u rre n t
% 8 5
80 8 0
%
60 6 0
40 4 0
20 2 0 3
0 0
-10 0 10 20 30 40 °C 50 0 1 0 2 0 3 0 4 0 4 5 °C 5 5
Operating temperature O p e r a tin g te m p e r a tu r e
Technical data
100 100
Rated output current
40 40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
100 100
Mains voltage
Mains voltage
% %
80 80
77 77
60 60
40 40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
1) Supplementary conditions: If a line commutating choke is 2) Supplementary conditions: 3) Use of MICROMASTER invert-
Input current at rated operating used, the specified values at Input current at rated operating ers with internal filter is not per-
point, applicable at short-cir- 380 V to 480 V are reduced to point, applicable at short-cir- missible on non-grounded
cuit voltage of the supply between 70% and 80% cuit voltage of the supply mains supplies.
USC = 1 % with reference to the USC $ 2.33 % with reference to
4) Generally suited to heavy
inverter rated power and rated the inverter rated power and
industrial applications. For
mains operating voltage of rated mains voltage of 400 V.
details please refer to Appen-
400 V without a line commutat-
dix on page A/4.
ing choke.
■ Overview
EMC filter, Class A 50 mA. The exact values de- • Frame sizes D to F: This means that the inverters
pend on the design, environ- The LC filters, frame sizes D with an output power
All 7.5 kW to 90 kW inverters
ment and cable lengths. Inter- to F, are designed for 0.75 kW comply with the
are supplied with an internal
ference-free operation with mounting upright in the con- EN 61 000-3-2 standard.
filter Class A.
residual current operated de- trol cabinet. Due to leakage
For inverters 110 kW to
vices with a trigger value of flux lines caused by physical Output choke
250 kW, EMC filters Class A
30 mA cannot be guaranteed. sources, a minimum dis-
are available. In this perfor- Output chokes can be sup-
tance of 50 mm to adjacent
mance range, the EMC filters However, operation with resid- plied for reducing the capaci-
modules and metal parts is
are only permitted to be used ual current operated devices tive compensation currents
recommended.
in combination with a line with a trigger value of 300 mA and dV/dt in the case of motor
commutating choke. is possible. Please refer to the Please note when using cables >50 m (shielded) or
Instruction Manual for details. LC filters: > 100 m (unshielded).
The requirements are fulfilled
using shielded cables with a • Only V/f, FCC control per- For max. permissible cable
LC filter
max. length of 25 m. missible lengths, see Technical Data.
The LC filter limits the rate of • Increased inverter load: ap-
EMC filter, Class B rise of voltage and the capac- prox. 10 % to 15 % Gland plate
itive charge/discharge cur- • Operation only permissible
Available for inverters 7.5 kW Gland plates are available for
rents which usually occur with with 4 kHz pulse frequency
to 15 kW with an internal Class inverters of frame size C. In
inverter operation. This means • The output frequency is lim-
A EMC filter. frame sizes D, E and F, the
that much longer shielded mo- ited to 150 Hz.
gland plates are integrated.
The requirements are fulfilled tor cables are possible when
using shielded cables with a using LC filters and the ser- Line commutating choke The gland plate facilitates the
max. length of 25 m. vice life of the motor achieves shield connection of power
Line commutating chokes are
values similar to those with di- and control cables and thus
For inverters 18.5 kW to 90 kW used to smooth voltage peaks
rect mains operation. ensure optimum EMC perfor-
without filters, EMC filters of or to bridge commutating
mance.
Class B from Schaffner can be The LC filters can be used for dips.
used. all MICROMASTER 430 invert- In addition, line commutating
ers of frame sizes C to F. chokes reduce the effects of
The requirements are fulfilled
harmonics on the inverter and
using shielded cables with a • Frame size C:
the power supply. If the line
max. length of 25 m to 50 m Only one footprint compo-
impedance is < 1 %, a line
(depending on the type, de- nent is permissible for frame
commutating choke must be
tails on request). size C. If a line choke and LC
used in order to reduce the
filter are used, the line choke
3 With this filter, the inverter
complies with the emission
must be located on the left of
current peaks.
the inverter. Required spac- No limits are currently defined
standard EN 55 011, Class B.
ing: 75 mm. in the EN 61 000-3-2 standard
Leakage currents: for professionally used devic-
es with a connected load
The leakage currents of the in-
> 1 kW.
verters with/without filter (inter-
nal/external) may exceed
30 mA. Typical values in prac-
tice are between 10 mA and
■ Technical data
LC filter
Max. permissible cable lengths from the motor to the inverter when using output chokes
The following table shows the
maximum permissible cable
lengths from the motor to the
inverter when using output
chokes.
Frame size Output choke Max. permissible motor cable lengths (shielded/unshielded)
for a mains voltage of
(FS) Type 380 V to 400 V ± 10 % 401 V to 480 V ± 10 %
C 6SE6400-3TC03-2CD3 200 m/300 m 100 m/150 m
D to F 6SE6400-3TC . . -. . D0 200 m/300 m 200 m/300 m
FX/GX Available soon
■ Overview
Basic Operator Panel 2 PROFIBUS module CANopen module Start-up tools
(BOP-2)
For a complete PROFIBUS Using the CANopen commu- • STARTER
With the BOP-2, individual pa- connection with up to nications module, an inverter is a graphic start-up soft-
rameter settings can be made. 12 Mbaud. Remote control can be linked to the CANopen ware for guided start-up for
Values and units are shown on of the inverter is possible with fieldbus system and remote MICROMASTER 410/420/
a 5-digit display. the PROFIBUS module. Re- control is then possible. 430/440 frequency inverters
mote control and operation at under Windows NT/2000/
Remote control and operation
the inverter can be combined XP Professional. Parameter
at the inverter can be com-
using an operator panel lists can be read out, al-
bined using an operator panel
plugged onto the PROFIBUS tered, stored, entered and
plugged onto the CANopen
module. The PROFIBUS mod- printed.
module.
ule can be supplied by an ex-
• DriveMonitor
ternal 24 V DC power supply The module is connected to
is a start-up software for list-
and is thus also active when the bus system through a
oriented programming of
the inverter is disconnected 9-pin Sub-D connector.
frequency inverters. This
from the power supply.
program executes under
Connection kit for
Connection by means of a Windows 95/98/NT/2000/
PC to inverter
9-pin Sub-D connector (avail- XP Professional.
able as an option). For controlling an inverter di-
Both programs are included
rectly from a PC if the appro-
Basic Operator Panel (BOP-2) on the Docu CD which is pro-
DeviceNet module priate software has been in-
vided with every inverter.
stalled (e.g. STARTER).
A BOP-2 can be used for sev- For networking the inverters to
Isolated RS-232 adapter mod-
eral inverters. It can be direct- the DeviceNet fieldbus system
ule for reliable point-to-point
ly mounted on the inverter or in widely used on the American
connection to a PC. Includes a
a control cabinet door using a market. A maximum transmis-
Sub-D connector and an
mounting kit. sion rate of 500 kbaud is pos-
RS-232 standard cable (3 m).
sible. Remote control of the in-
verter is possible with the
Operator panel door mount-
DeviceNet module.
ing kit for single inverter
Remote control and operation
For mounting an operator pan-
at the inverter can be com-
el BOP-2 in a control cabinet
bined using an operator panel
door. Degree of protection
plugged onto the DeviceNet
3 module.
IP56. Contains a cable adapt-
er module with screwless ter- 1) A shielded cable of type
The connection to the minals for use with user’s own Belden 8132 (28 AWG) is
DeviceNet bus system is RS-232 cables 1). recommended.
The maximum cable length is
made using a 5-pin connector 5 m for RS-232.
with terminal strip.
Documentation
Dimension drawings
Drill pattern
204 (8.03)
ADA51-5009b
245 (9.65)
309 (12.16)
ADA51-5002d
174 (6.85)
Fixing with
(7 195
8)
4 x M5 bolts
.6
4 x M5 nuts
185 (7.28) 4 x M5 washers
Inverter frame size C Tightening torque with washers fitted:
3.0 Nm
Inverter frame size C
Ventilation clearance required at top with gland plate
and bottom: 100 mm
Drill pattern
Drill pattern
3
616.4 (24.27)
650 (25.59)
520 (20.47)
486 (19.13)
ADA51-5021b
ADA51-5020b
235 (9.25)
235 (9.25)
(9 245
5)
(9 245
5)
.6
Dimension drawings
Drill pattern
Drill pattern
1110 (43.70)
1150 (45.28)
850 (33.46)
810 (31.89)
ADA51-5023b
ADA51-5022b
(1 320
6)
6)
4 x M8 bolts 4 x M8 bolts
2.
2.
Dimension drawings
Drill pattern
Drill pattern
125 125
(4.92) (4.92)
125 125
(4.92) (4.92)
1508 (59.37)
1533 (60.35)
1375 (54.13)
1400 (55.12)
G_DA51_EN_05075
G_DA51_EN_05074
125 125
(4.92) (4.92)
3
125 125
1. 5
)
(4.92) (4.92)
46
(2 54
4. 6
)
06
(1 35
Fixing with
326 Fixing with 326 6 x M8 bolts
(12.83) 6 x M8 bolts (12.83) 6 x M8 nuts
6 x M8 nuts 6 x M8 washers
Inverter frame size FX 6 x M8 washers Inverter frame size GX
Tightening torque
Tightening torque with washers
with washers fitted: 13.0 Nm
fitted: 13.0 Nm Ventilation clearance
Ventilation clearance required:
required: at top: 250 mm
at top: 250 mm at bottom: 150 mm
at bottom: 150 mm in front: 100 mm
in front: 100 mm
Dimension drawings
■ EMC filter
38 185 (7.28)
(1.5) 156 (6.14)
4 x M5
219 (8.62)
232 (9.13)
204 (8.03)
245 (9.65)
ADA51-5012c
174 54 (2.13)
(6.85)
b1
n4
b
c
n3
a
a1
G_DA51_XX_05103
Dimension drawings
■ LC filter
174 (6.85)
320 (12.6)
335 (13.19)
382 (15.04)
G_DA51_EN_05078a
G_DA51_EN_05081
156 (6.14)
(FS)
a b c n1 n2
6SE6400-3TD03-7DD0 D 278 240 230 115 190
(10.94) (9.45) (9.06) (4.53) (7.48)
6SE6400-3TD04-8DD0 D 290 240 240 125 190
(11.42) (9.45) (9.45) (4.92) (7.48)
6SE6400-3TD06-1DD0 D 345 300 220 120 240
(13.58) (11.81) (8.66) (4.72) (9.45)
a
Dimension drawings
c b c b
G_DA51_XX_05014e
a
a
DA51-5051
Line commutating Dimensions Weight Line commutating Dimensions Weight
choke for (max.) choke for (max.)
a b c kg a b c kg
Frame size C 245 185 50 2.3 Frame size D 520 275 85 9.5
(9.65) (7.28) (1.97) (20.47) (10.83) (3.35)
Frame size E 650 275 95 17.0
(25.59) (10.83) (3.74)
Line commutating choke for frame size C Line commutating choke for frame sizes D and E
b
c
3
DA51-5052
choke (max.)
type 6SE6400- Frame size a b c n1 n2 kg
3CC11-.... F 210 240 141 109 190 25.0
(8.27) (9.45) (5.55) (4.29) (7.48)
n1
n2
b
c
Dimension drawings
■ Output chokes
c b
G_DA51_XX_05050a
(max.)
a b c kg
Frame size C 245 185 80 5.6
(9.65) (7.28) (3.15)
b
Output for inverter Dimensions Weight
c
choke (max.)
type Frame size a b c n1 n2 kg
6SE6400- (FS) (to DIN 41308)
3TC03-8DD0 D 210 225 179 76 176 16.1
DA51-5052
n1 3TC08-0ED0 E
(9.76)
210
(10.63)
225
(8.23)
150
(3.46)
76
(7.87)
176 10.4 3
n2 (8.27) (8.86) (5.91) (2.99) (6.93)
3TC14-5FD0 F 321 350 288 120 264 51.5
Output chokes (12.64) (13.78) (11.34) (4.72) (10.39)
for inverters of size D, E and F
3TC15-4FD0 F 210 225 150 76 176 11.2
(8.27) (8.86) (5.91) (2.99) (6.93)
Dimension drawings
G_DA51_XX_05042b
Example:
Assembly of
inverter, filter and choke
If additional options are
required, they must be
mounted on the side.
4/12 Options
Description
Description
Circuit diagrams
2 0 0 to 2 4 0 V 1 /3 A C
I F n 3 8 0 to 4 8 0 V 3 A C
5 0 0 to 6 0 0 V 3 A C
P E
O J o g P
F S 1
+ 1 0 V B O P P E F o r a d d itio n a l d ig ita l in p u ts
1 L , N (D IN 7 , D IN 8 ) e x te rn a l
S e r ia l (L 1 , L 2 )
P ro to c o l c o n n e c tio n s s h o u ld b e m a d e :
0 V o r
2
A IN 1 + L 1 , L 2 , L 3
-> 4 . 7 k 9 A 1 1
3
A IN 1 - D
2 2
4
3 1 0
A IN 2 + A
1 0 4 1 1
D D IN 7 D IN 8
A IN 2 -
1 1
N o te s :
D IN 1 W h e n a n a n a lo g in p u t is
5 c o n fig u re d a s a d ig ita l in p u t
D IN 2 th e th re s h o ld v a lu e s a r e a s
fo llo w s :
6 A C
D IN 3 1 .7 5 V D C = o ff
O p to is o la tio n
3 .7 V D C = o n
7
D C A IN 1 : 0 V to 1 0 V , 0 m A to 2 0 m A
D IN 4
a n d -1 0 V to + 1 0 V
8 A IN 2 : 0 V to 1 0 V
D IN 5
a n d 0 m A to 2 0 m A
1 6
D IN 6
B + /D C +
1 7
P N P O u tp u t + 2 4 V
( is o la te d )
o r 9 B r a k in g
N P N O u tp u t 0 V r e s is to r
( is o la te d )
2 8 B -
P T C A
A
M o to r 1 4 9 0 k W t o 2 0 0 k W in v e r t e r s d o n 't
P T C /K T Y P T C B D - h a v e a n in te g r a te d b r a k in g c h o p p e r
D C
1 5 C P U
A O U T 1 +
0 - 2 0 m A , A
1 2 D C
m a x . 5 0 0 9 A O U T 1 - D
1 3 A C
A C
A O U T 2 +
0 - 2 0 m A , A D C
2 6
m a x . 5 0 0 9 A O U T 2 - D
2 7 D /L -
R L 1
C o n n e c tio n
R L 1 - C 6 0 H z fo r
N o t
4 R L 1 - B
2 0
1 9
u s e d
1 2
5 0 H z C /L +
e x te rn a l
b r a k in g
R L 1 - A D IP S w itc h e s u n it
O u tp u t re la y 1 8
R L 2 (o n C o n tro l B o a rd )
c o n ta c ts
2 5 0 V A C , m a x . 2 A R L 2 - C
( in d u c tiv e lo a d ) 2 2
3 0 V D C , m a x . 5 A R L 2 - B
2 1
( r e s is tiv e lo a d )
R L 3 A IN 1 A IN 2
0 - 2 0 m A
R L 3 - C
2 5 0 - 1 0 V
R L 3 - B
2 4 1 2 D C
R L 3 - A D IP S w itc h e s
2 3 (o n I/O B o a rd )
W h e n a c o m m u n ic a tio n s A C
m o d u le is c o n n e c te d , P +
2 9 R S 4 8 5
th e s e r ia l in te r fa c e
d o e s n 't w o rk . N -
3 0 P E U , V , W
G _ D A 5 1 _ E N _ 0 5 0 2 4 g
M
3 ~
Circuit diagrams
Mains connections
View A
Motor connections
View A
AIN1 AIN2 RL1-A RL1-B RL1-C RL2-B RL2-C RL3-A RL3-B RL3-C
A DA51-5025
S1 S2
18 19 20 21 22 23 24 25
DIP Switches:
0 mA to 20 mA
or Output relay contacts
0 V to 10 V
12 13 14 18
15 16 17 26 27 28 29 30
NPN *)
1 2 3 18
4 5 6 7 8 9 10 11
PNP *)
Technical data
Technical data
■ Derating data
Pulse frequency
Technical data
100 VT 1 0 0
Rated output current
R a te d o u tp u t c u rre n t
% CT 8 5
80 8 0
70 %
60 6 0
50
40 4 0
20 2 0
0 0
-10 0 10 20 30 40 50 60 °C 70 0 1 0 2 0 3 0 4 0 4 5 °C 5 5
Operating temperature O p e r a tin g te m p e r a tu r e
ADA51-5018c ADA51-5046
100 100
Rated output current
Rated output current
% 85
80 80
%
60 60
40 40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
100 100
Mains voltage
Mains voltage
% %
80 80
77 77
4 60
40
60
40
20 20
0 0
0 1000 2000 3000 m 4000 0 1000 2000 3000 m 4000
Operational altitude Operational altitude
1) Supplementary conditions: 2) Supplementary conditions: If a line commutating choke is 3) Generally suited to heavy
Input current at rated operating Input current at rated operating used, the specified values at industrial applications. For details
point, applicable at short-cir- point, applicable at short-cir- 500 V to 600 V are reduced to please refer to Appendix on
cuit voltage of the supply cuit voltage of the supply between 80% and 90%. page A/4.
Usc = 2.33 % with reference to USC = 1 % with reference to the
the inverter rated power and inverter rated power and rated
rated mains operating voltage mains operating voltage of
of 400 V. 500 V without a line commutat-
ing choke.
■ Overview
EMC filter, Class A Filter Class B with low • Frame size C: power utility company for
leakage currents Only one footprint compo- authorization to connect the
Filter for inverters without an
nent is permissible for frame devices to the public power
internal filter for EMC filter for 1 AC 200 V to
size C. If a line choke and LC supply.
240 V inverters, frame sizes A
• 3 AC 200 V to 240 V, filter are used, the line choke No limits are currently defined
and B, without an internal EMC
frame sizes A and B must be located on the left of in the EN 61 000-3-2 standard
filter Class A.
the inverter. Required spac- for professionally used devic-
• 3 AC 380 V to 480 V,
With this filter, the inverter ing: 75 mm. es with a connected load
frame size A, FX, GX
complies with the emission >1 kW which means that the
• Frame sizes D to F:
Filters for frame sizes FX and standard EN 55 011, Class B. inverters with an output power
The LC filters, frame sizes D
GX are only permitted to be The leakage currents are re- 0.75 kW comply with the
to F, are designed for
used in combination with a line duced to < 3.5 mA. EN 61 000-3-2 standard.
mounting upright in the con-
commutating choke.
The requirements are fulfilled trol cabinet. Due to leakage Output choke
All other inverters can be sup- using shielded cables with a flux lines caused by physical
plied with an internal Class A max. length of 5 m. sources, a minimum dis- Output chokes can be sup-
filter. tance of 50 mm to adjacent plied for reducing the capaci-
Leakage currents: tive compensation currents
modules and metal parts is
The requirements are fulfilled and dV/dt in the case of motor
The leakage currents of the in- recommended.
using shielded cables with a cables >50 m (shielded) or
verters with/without filter (inter-
max. length of 25 m. Please note when using >100 m (unshielded).
nal/external) may exceed
LC filters:
30 mA. Typical values in prac- For max. permissible cable
EMC filter, Class B
tice are between 10 mA and • Only V/f, FCC control lengths, see the Technical
Filter for inverters without an 50 mA. The exact values de- permissible Data.
internal filter for pend on the design, environ- • Increased inverter load:
ment and cable lengths. Inter- approx. 10 % to 15 % Brake resistors
• 3 AC 200 V to 240 V,
ference-free operation with re- • Operation only permissible
frame sizes A and B The brake resistors are de-
sidual current operated devic- with 4 kHz pulse frequency
• 3 AC 380 V to 480 V, es with a trigger value of signed for use with the
The output frequency is limit- MICROMASTER 440 inverter
frame size A. 30 mA cannot be guaranteed.
ed to 150 Hz. series, frame sizes A to F, with
However, operation with resid-
The requirements are fulfilled internal brake chopper and
ual current circuit-breakers Line commutating choke
using shielded cables with a enable loads with a large mo-
with a trigger value of 300 mA
max. length of 25 m. Line commutating chokes are ment of inertia to be braked
is possible. Please refer to the
For inverters 15 kW to 75 kW Instruction Manual for details. used to smooth voltage peaks quickly. During braking of the
without filters, EMC filters of or to bridge commutating motor and the load, excess
Class B from Schaffner can be LC filter dips. In addition, line commu- energy is fed back to the in-
used. tating chokes reduce the ef- verter. This causes the voltage
The LC filter limits the rate of fects of harmonics on the in- to rise in the DC link. The in-
The requirements are fulfilled rise of voltage and the capac- verter and the power supply. If verter transfers the excess en-
using shielded cables with a itive charge/discharge cur- the line impedance is < 1 %, a ergy to the externally mounted
max. length of 25 m to 50 m rents which usually occur with line commutating choke must braking resistor.
(depending on the type, de- inverter operation. This means be used in order to reduce the
tails on request). that much longer shielded mo- For MICROMASTER 440 in-
current peaks. verters of frame sizes FX and
tor cables are possible when
With this filter, the inverter In line with EN 61 000-3-2 reg- GX, external SIMOVERT
using LC filters and the ser-
complies with the emission ulations “Limits for harmonic MASTERDRIVES brake units
vice life of the motor achieves
standard EN 55 011, Class B. currents with device input cur- and the appropriate brake re-
values similar to those with di-
rect mains operation. rent 16 A per phase”, there sistors can be used (see
4 Additional EMC filter,
Class B The LC filters can be used for
are special aspects for drives
with 250 W to 550 W and 230 V
Catalog DA 65.10).
■ Technical data
LC filter
Mains voltage 3 AC 380 V to 480 V 3 AC 500 V to 600 V
Current (at 40 °C/50 °C)
For frame size A (0.37 to 1.5 kW) 4.5 A/4.1 A –
For frame size B (2.2 to 4 kW) 11.2 A/10.2 A –
For frame size C (0.75 to 4 kW) – 9.0 A/6.1 A
For frame size C (5.5 to 11 kW) 32.6 A/29.7 A 22.4 A/17 A
For frame size D (15 kW) 38.8 A/32 A 27.5 A/22 A
For frame size D (18.5 kW) 32.6 A/38 A 22.4 A/27 A
For frame size D (22 kW) 63.2 A/45 A 41.8 A/32 A
For frame size E (30 kW) 76.5 A/62 A 53 A/41 A
For frame size E (37 kW) 112.2 A/90 A 63.2 A/52 A
For frame size F (45 kW) 112.2 A/90 A 78.5 A/62 A
For frame size F (55 kW) 147.9 A/110 A 101 A/77 A
For frame size F (75 kW) 181.6 A/145 A 127.5 A/99 A
Limiting of motor overvoltage 1078 V
dV/dt limiting 500 V/ms
Pulse frequency 4 kHz
Max. motor frequency 150 Hz
Max. permissible motor cable lengths Shielded 200 m
Unshielded 300 m
Insulation strength Overvoltage category III to VDE 0110
Electromagnetic compatibility Up to 200 m motor cable length with emissions to Class A according to EN 55 011 in conjunc-
tion with filtered inverters and unshielded cables
Conformity CE according to the low-voltage directive 73/23/EEC
Approvals UL available soon
Strain resistance EN 60 068-2-31
Humidity 95 % humidity, non-condensing
Degree of protection Frame sizes A to C IP20 (to EN 60 529)
Frame sizes D to F IP00 / IP20 (to EN 60 529 with terminal covers)
Insulation class H (180 °C)
Temperature range Operation –10 °C to +40 °C (+14 °F to +104 °F) 100 % Pn
to +50 °C (to +122 °F) 80 % Pn
Storage –25 °C to +70 °C (–13 °F to +158 °F)
Installation altitude Frame sizes A to C Up to 2000 m: 100 % Pn
2000 to 4000 m: 62.5 % Pn
Frame sizes D to F: Up to 1000 m: 100 % Pn
1000 to 4000 m: 12.5 % derating for each 1000 m
Mounting position Vertical
Ventilation clearances Top 100 mm
Bottom 100 mm
Side 100 mm
Connection system Input, litz wire or terminal 1U1, 1V1, 1W1
Output, terminals 1U2, 1V2, 1W2
Torque for Terminal cross-section Torque
conductor connections Frame sizes A to C – 1.5 Nm to 1.8 Nm
Frame sizes D to F 16 mm2 2.0 Nm to 4.0 Nm
2
35 mm 2.5 Nm to 5.0 Nm
2
50 mm 3.0 Nm to 6.0 Nm
2
95 mm 6.0 Nm to 12.0 Nm
2
150 mm 10.0 Nm to 20.0 Nm
Weight, approx. for frame size A 7 kg
for frame size B 11 kg
for frame size C
for frame size D
for frame size E
8.5 kg to 29 kg
21 kg to 42 kg
49.5 kg to 67 kg
4
for frame size F 67 kg to 125.5 kg
Max. permissible cable lengths from the motor to the inverter when using output chokes
The following table shows the inverter when using output
maximum permissible cable chokes.
lengths from the motor to the
Frame size Output choke Max. permissible motor cable lengths (shielded/unshielded)
for a mains voltage of
(FS) Type 200 V to 240 V ± 10 % 380 V to 400 V ± 10 % 401 V to 480 V ± 10 % 500 V to 600 V ± 10 %
A 6SE6400-3TC00-4AD3 200 m/300 m – – –
A 6SE6400-3TC00-4AD2 200 m/300 m 150 m/225 m 100 m/150 m –
B 6SE6400-3TC01-0BD3 200 m/300 m 150 m/225 m 100 m/150 m –
C 6SE6400-3TC03-2CD3 200 m/300 m 200 m/300 m 100 m/150 m –
C 6SE6400-3TC01-8CE3 – – – 100 m/150 m
D to F 6SE6400-3TC. .-. . . . 200 m/300 m 200 m/300 m 200 m/300 m 200 m/300 m
FX/GX Available soon
4 75
90
110
100
125
150
6SE6440-2UD37-5FA1
6SE6440-2UD38-8FA1
6SE6440-2UD41-1FA1
3NA3144
–
–
3NE1227-0
3NE1230-0
3VL4731- . DC36- . . . .
On request
■ Overview
Basic Operator Panel (BOP) The AOP is directly plugged PROFIBUS module CANopen module
into the inverter, or communi-
With the BOP, individual pa- For a complete PROFIBUS Using the CANopen commu-
cates with the latter through a
rameter settings can be made. connection with up to nications module, an inverter
door mounting kit. Together
Values and units are shown on 12 Mbaud. Remote control can be linked to the CANopen
with the “AOP door mounting
a 5-digit display. of the inverter is possible with fieldbus system and remote
kit for multiple inverters”, the
the PROFIBUS module. Re- control is then possible.
AOP permits bus communica-
mote control and operation at
tion with up to 30 inverters at a Remote control and operation
the inverter can be combined
transmission rate of 38 kbaud. at the inverter can be com-
using an operator panel
(RS485, USS). bined using an operator panel
plugged onto the PROFIBUS
plugged onto the CANopen
For servicing purposes, the module. The PROFIBUS mod-
module.
AOP furthermore supports the ule can be supplied by an ex-
download and upread of com- ternal 24 V DC power supply The module is connected to
plete parameter kits. and is thus also active when the bus system through a
the inverter is disconnected 9-pin Sub-D connector.
Asian Advanced from the power supply.
Operator Panel (AAOP) Pulse encoder evaluation
Connection by means of a
module
The AAOP is the Chinese ver- 9-pin Sub-D connector (avail-
Basic Operator Panel (BOP) sion of the AOP operator pan- able as an option). The pulse encoder evaluation
el. It has an enhanced display module permits direct con-
A BOP can be used for several
and supports the operating DeviceNet module nection of the most widely en-
inverters. It can be directly
languages of Chinese (simpli- countered digital pulse en-
mounted on the inverter or in a For networking the inverters to
fied) and English. coders to the inverter.
control cabinet door using a the DeviceNet fieldbus system
mounting kit. widely used on the American They offer the following func-
market. A maximum transmis- tions:
Advanced Operator Panel sion rate of 500 kbaud is pos- ■ Zero speed at full load
(AOP) sible. Remote control of the in- torque
verter is possible with the De- ■ Extremely accurate speed
The AOP enables
viceNet module. Remote con- control
MICROMASTER 440 parame-
trol and operation at the invert-
ter kits to be easily read and ■ Increased dynamic re-
er can be combined using an
modified. In contrast to the sponse of speed and
operator panel plugged onto
BOP, the value and meaning torque control.
the DeviceNet module.
of the parameters can be di-
rectly displayed as plain text The connection to the This module can be used with
in several langauges by fast DeviceNet bus system is HTL and TTL pulse encoders
scrolling of the address. made using a 5-pin connector (High voltage Transistor
Asian Advanced Operator Panel with terminal strip. Logic, 24 V and Transistor
(AAOP) Logic, 5 V).
4
Advanced Operator Panel (AOP)
■ Overview (continued)
Connection kit for Connection kit for PC AOP door mounting kit for Start-up tools
PC to inverter to AOP multiple inverters (USS)
• STARTER
For controlling an inverter di- For connecting a PC to an For mounting an AOP or AAOP Starter is graphic start-up
rectly from a PC if the appro- AOP or AAOP. Offline pro- in a control cabinet door. software for guided start-up
priate software has been in- gramming of inverters and Degree of protection IP56. for MICROMASTER 410/
stalled (e.g. STARTER). Isolat- archiving of parameter kits The AOP or AAOP can com- 420/430/440 frequency in-
ed RS-232 adapter module for possible. Includes a desktop municate with several invert- verters under Windows NT/
reliable point-to-point connec- attachment kit for an AOP or ers by means of the RS-485 2000/XP Professional. Pa-
tion to a PC. Includes a Sub-D AAOP, an RS-232 standard USS protocol. The 4-pin con- rameter lists can be read
connector and an RS-232 cable (3 m) with Sub-D con- necting cable from the AOP or out, altered, stored, entered
standard cable (3 m). nectors and a universal power AAOP to the RS-485 terminals and printed.
supply unit. of the inverter and to the 24 V
• DriveMonitor
user terminal strip is not in-
is a start-up software for list-
Operator panel door mount- cluded 2).
oriented programming of
ing kit for single inverter
frequency inverters. This
For mounting an operator 1) A shielded cable of type program executes under
Belden 8132 (28 AWG) is rec-
panel in a control cabinet ommended. The maximum
Windows 95/98/NT/2000/
door. Degree of protection cable length is 5 m for RS-232. XP Professional.
IP56. Contains a cable 2) A shielded cable of type Both programs are included
adapter module with screw- Belden 8/32 (28 AWG) is rec-
ommended. The maximum on the Docu CD which is pro-
less terminals for use with
cable length is 10 m for vided with every inverter.
user’s own RS-232 cables 1). RS-485.
■ Technical data
PROFIBUS module DeviceNet module
6SE6400-1PB00-0AA0 6SE6400-1DN00-0AA0
Documentation
Dimension drawings
(2.28)
58
173 (6.81)
160 (6.29)
DIN Rail ADA51-5000e
ADA51-5007c
147 (5.79)
195 (7.68)
Fixing with
2 x M4 bolts, 2 x M4 nuts,
(5 149
2 x M4 washers
7)
.8
Drill pattern
174 (6.85)
G_DA51_EN_05001d
ADA51-5008b
202 (7.95)
258 (10.16)
138 (5.43)
(6 172
Fixing with
7)
.7
4 x M4 bolts, 4 x M4 nuts,
149 (5.87) 4 x M4 washers
Inverter frame size B Tightening torque with washers fitted: Inverter frame size B with gland plate
2.5 Nm
Ventilation clearance required
Top and bottom: 100 mm
Drill pattern
204 (8.03)
4
ADA51-5009b
245 (9.65)
309 (12.16)
ADA51-5002d
174 (6.85)
Fixing with
(7 195
8)
4 x M5 bolts, 4 x M5 nuts,
.6
4 x M5 washers
185 (7.28)
Tightening torque with washers fitted:
Inverter frame size C 3.0 Nm
Ventilation clearance required Inverter frame size C with gland plate
Top and bottom: 100 mm
Dimension drawings
Drill pattern
Drill pattern
616.4 (24.27)
650 (25.59)
520 (20.47)
486 (19.13)
ADA51-5020b
ADA51-5021b
5)
5)
810 (31.89)
4
ADA51-5023b
ADA51-5022b
(1 320
6)
6)
2.
Dimension drawings
Drill pattern
Drill pattern
125 125
(4.92) (4.92)
125 125
(4.92) (4.92)
1508 (59.37)
1533 (60.35)
1375 (54.13)
1400 (55.12)
G_DA51_EN_05074
G_DA51_EN_05075
125 125
125 125 (4.92) (4.92)
1. 5
(4.92) (4.92)
)
46
(2 54
4. 6
)
06
(1 35
Fixing with
326 Fixing with 326 6 x M8 bolts
(12.83) 6 x M8 bolts (12.83) 6 x M8 nuts
6 x M8 nuts 6 x M8 washers
Inverter frame size FX 6 x M8 washers Inverter frame size GX
Tightening torque
Tightening torque with washers
with washers fitted: 13.0 Nm
fitted: 13.0 Nm Ventilation clearance
Ventilation clearance required:
required: at top: 250 mm
at top: 250 mm at bottom: 150 mm
at bottom: 150 mm in front: 50 mm
in front: 40 mm
Dimension drawings
■ EMC filter
38 185 (7.28)
(1.5) 156 (6.14)
24 149 (5.87)
73 (2.87)
23.5 (0.94) 120 (4.72)
(0.93) 56 (2.2)
4 x M5
4 x M4
219 (8.62)
232 (9.13)
2 x M4
187 (7.36)
200 (7.87)
204 (8.03)
245 (9.65)
174 (6.85)
187 (7.36)
213 (8.39)
174 (6.85)
200 (7.87)
160 (6.3)
ADA51-5010e
ADA51-5011c
ADA51-5012c
42.5 (1.67) 49.5 (1.95)
138 174 54 (2.13)
(5.43) (6.85)
EMC filter for frame size A For frame size B For frame size C
b1
n4
b
c
n3
a
a1
G_DA51_XX_05103
Dimension drawings
■ LC filter
280 (11.02)
287 (11.3)
293 (11.53)
300 (11.81)
340 (13.38)
334 (13.15)
G_DA51_EN_05080
G_DA51_EN_05077
G_DA51_EN_05079
G_DA51_EN_05076
56 120
(2.2) (4.72)
174 (6.85)
320 (12.6)
335 (13.19)
382 (15.04)
G_DA51_EN_05078a
G_DA51_EN_05081
156 (6.14)
Dimension drawings
■ LC filter
G_DA51_XX_05082
(FS)
a b c n1 n2
6SE6400-3TD03-7DD0 D 278 240 230 115 190
(10.94) (9.45) (9.06) (4.53) (7.48)
6SE6400-3TD04-8DD0 D 290 240 240 125 190
(11.42) (9.45) (9.45) (4.92) (7.48)
6SE6400-3TD06-1DD0 D 345 300 220 120 240
(13.58) (11.81) (8.66) (4.72) (9.45)
a
Dimension drawings
G_DA51_XX_05014e
(8.39) (5.91) (1.97)
a
a
DA51-5013e
c b
DA51-5051
Dimension drawings
■ Output chokes
c b
c b
G_DA51_XX_05050a
3TC00-4AD2 200 75.5 110 1.95
(7.87) (2.97) (4.33)
a
a
DA51-5049
Output choke
for frame size A For frame sizes B and C
6SE6400-3TC00-4AD2 6SE6400-3TC01-0BD3
6SE6400-3TC00-4AD3 6SE6400-3TC01-8CE3
6SE6400-3TC03-2CD3
b
c
DA51-5052
a
n1
n2
Dimension drawings
■ Brake resistors
Fig. 1: Fig. 2: Fig. 3: n4
b
b c b
c
n4 n4
n3
DA51-5056
a
n3
a
n3
a
DA51-5055a
DA51-5069
n1 c0
c1
n2
4 4BD21-2DA0 27 D 3
(11.22)
515
(7.28)
270
(5.91)
175
(7.28)
210
(8.54)
242
(6.69)
195
(5.71)
205
(7.87)
350
(9.06)
315 7.4
(20.28) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (13.78) (12.40)
4BD22-2EA0 15 E 3 645 270 175 210 242 195 205 480 315 10.6
(25.39) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (18.90) (12.40)
4BD24-0FA0 8.2 F 3 650 400 315 382 382 335 270 510 435 16.7
(25.59) (15.75) (12.40) (15.04) (15.04) (13.19) (10.63) (20.08) (17.13)
4BE14-5CA0 120 C 3 285 185 150 185 217 170 145 200 230 3.8
(11.22) (7.28) (5.91) (7.28) (8.54) (6.69) (5.71) (7.87) (9.06)
4BE16-5CA0 82 C 3 285 185 150 185 217 170 145 200 230 3.8
(11.22) (7.28) (5.91) (7.28) (8.54) (6.69) (5.71) (7.87) (9.06)
4BE21-3DA0 39 D 3 515 270 175 210 242 195 205 350 315 7.4
(20.28) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (13.78) (12.40)
4BE21-8EA0 27 E 3 645 270 175 210 242 195 205 480 315 10.6
(25.39) (10.63) (6.89) (8.27) (9.53) (7.68) (8.07) (18.90) (12.40)
4BE24-2FA0 12 F 3 650 400 315 382 382 335 270 510 435 16.7
(25.59) (15.75) (12.40) (15.04) (15.04) (13.19) (10.63) (20.08) (17.13)
Brake resistors for inverters of frame sizes A to F All dimensions in mm (values in brackets are in inches)
Dimension drawings
G_DA51_XX_05016c
Example:
Assembly of inverter,
filter and choke
If additional options are
required, they must be
mounted on the side.
Notes
A/2 Certificates
Appendix
■ Certificates
Appendix
■ Certificates (continued)
Legend for EC declaration of conformity:
Appendix
Appendix
UL listing
u and cu listed power conversion
equipment Type 5B33, in accordance
with UL508C.
For use in pollution degree 2 environment.
Appendix
Drive ES Basic V5.2 *) CD-ROM and copy license Five standard languages 6SW1700–5JA00–2AA1
copy license (60 installations)
Drive ES SIMATIC V5.x Product license only (without soft- Five standard languages 6SW1700–5JC00–1AC0
copy license/runtime license ware and documentation)
Appendix
Appendix
■ Demonstration case
SIDEMO demonstration case system
The SIDEMO range of modular The demonstration systems
demonstration case systems are fitted in dark blue transport
also includes cases for the cases (400 x 300 x 210 mm).
MICROMASTER inverters. The transport cases can be
stacked.
The MICROMASTER demon-
stration cases can be operat- If the MICROMASTER 420/440
ed on 230 V supplies on their demonstration case is ex-
own or together with other panded with a PROFIBUS
demonstration systems such module (not included in scope
as LOGO!, SIMATIC S7-200, of supply of the case), it is also
SITOP DC-UPS. possible to demonstrate incor-
poration into TIA in combina-
tion with the SIMATIC S7-300
Compact and Touchpanel
TP170B demonstration sys-
tems.
Further information, e.g. 110 V versions, is available on the Internet at: http://www.siemens.de/sidemo
Appendix
■ Training center
The Siemens A&D Training Headquarters:
Centers are located world-
Siemens AG
wide and offer the courses list-
Automation and Drives
ed below for MICROMASTER.
Training Center
Individual course contents, or
PO Box 48 48
training on site at customers,
90327 Nuremberg
can also be carried out.
E-Mail:
Contact:
A&D.Kursbuero@nbgm.
Every A&D Information and siemens.de
Training Center in the regions Tel.:
and the regional companies in +49 (0) 9 11-8 95-32 00
Germany: Fax:
Tel.: 0 18 05-23 56 11 +49 (0) 9 11-8 95-32 75
■ Training courses
MICROMASTER 4 • Use of special functions • Commissioning of the Computer based training
servicing and such as flying restart, DC MICROMASTER inverter on (CBT) and Web based
commissioning braking PROFIBUS DP training (WBT)
SD-MM4 (2 days) • Alarms and fault signals • Transmission of process Commissioning is carried out
data and parameter values in interactive mode using the
This course is aimed at com- • Practical exercises using
(protocol, PNO profile) MICROMASTER 420 frequen-
missioning and servicing en- the field-proven demonstra-
cy inverter. In particular, han-
gineers for the tion cases. • PROFIBUS DP with Motion
dling of the parameter key-
MICROMASTER 4 drives. It Control expansion (lateral
board is practically identical to
covers proper utilization of the MICROMASTER 4 communication, equidis-
the original. The training time
MICROMASTER 440 inverter communication tance, isochrone mode)
is 3 to 4 hours depending on
functionality. The
SD-MM4-COM (2 days) • Block library the level of knowledge
MICROMASTER 420 is also
included. The basics are This course is aimed at com- • Drive ES SIMATIC Contents:
taught with more in-depth missioning and servicing en-
• Fault diagnostics of the drive • Asynchronous motors con-
knowledge as required. The gineers working with the
via the bus system nected to power supply and
course is therefore also suit- MICROMASTER 4 on the
inverter
able for beginners. PROFIBUS DP. Knowledge of • Practical exercises on the
MICROMASTER and MICROMASTER 440 dem- • Overview of
Course targets/contents:
SIMATIC S7 are prerequisites. onstration cases and the MICROMASTER inverter
• Fundamentals of asynchro- SIMATIC S7 demonstration
It explains the concept of • Electrical installation
nous motors cases with CPU 315-2 DP.
Totally Integrated Automation
• Parameter input, structure of
• Fundamentals of inverters (TIA). Tip:
the parameter kit
The course sometimes direct-
• Programming using BOP, Course targets/contents:
ly follows the SD-MM4 course. • Rating plate of motor
AOP
• Fundamentals of Participants need then only
• Simple commissioning
• PC programs DriveMonitor/ PROFIBUS DP with empha- travel once.
STARTER sis on drive technology • Assignment of different
Note:
functions to the terminals.
• Commissioning using V/f • Design of the PROFIBUS DP This course handles the
characteristic and vector bus system DriveES SIMATIC block li-
control brary. The SD-MD-COM
• Configuration of a You can find further informa-
course provides comprehen-
• Optional programming of in- PROFIBUS DP network in tion in Catalog ITC or at
put and output terminals Step 7
sive information on alterna-
tives such as loading/transfer
http://www.sitrain.com. A
commands, system functions,
DVA-S7 blocks.
Appendix
■ Overview of motors
Siemens motors are ideally In addition to the motors listed Catalog M 11 contains the This catalog is suitable for IEC
matched to the in the table, explosion-proof complete range of products motors. For motors according to
MICROMASTER inverters. motors, marine motors and with ordering data, technical US standards (NEMA) please
The table provides an over- combustion gas motors are details and explanations. refer to:
view of the most common also available. http://www.sea.siemens.com/
types of motors from Siemens. motors
Squirrel-cage motors
Main Motors with gray cast iron casing Motors with aluminium casing
characteristics
1LG6 1LG4 1LA8 1LA9 1LA9 1LA7 1LA5
Efficiency class *) *) *) EPACT *)
Rating (4-pole) 18.5 – 200 kW 18.5 – 200 kW 250 – 1000 kW 0.06 – 30 kW 0.08 – 40 hp 0.06 – 15 kW 18.5 – 45 kW
Speeds 3000 rpm 3000 rpm 3600 rpm 3000 rpm
1500 rpm 1500 rpm 1800 rpm 1500 rpm
1000 rpm 1000 rpm 1200 rpm 1000 rpm
750 rpm 750 rpm
Voltage (at 50 Hz if 230/400 V d/* 400/690 V d/* 230/400 V d/* 60 Hz 460 V d 230/400 V d/*
not specified 400/690 V d/* 400/690 V d/* 400/690 V d/*
otherwise)
Size 180 – 315 315 – 450 56 – 200 56 – 160 180 – 225
Design IM B3 IM B3 IM B3
IM B5 IM V1 IM B5
IM V1 IM B35 IM V1
IM B14 (Sizes 100 to 160) IM B14 (Sizes 56 to 160)
IM B35 IM B35
Casing Gray cast iron Aluminum
Degree of IP55 (IP65, IP56) IP55 (IP56) IP55 (IP65, IP56)
protection
A
*) 1.1 kW to 90 kW, 2-pole and 4-pole
Appendix
Appendix
Appendix
Appendix
■ Service On Site
In the face of harsh competition you need optimum conditions to With Service On Site we offer
keep ahead all the time: services for startup and mainte-
A strong starting position. A sophisticated strategy and team for nance, essential for ensuring
the necessary support - in every phase. system availability.
Service & Support from Siemens provides this support with a
complete range of different services for automation and drives. In Germany
0180 50 50 444 2)
In every phase: from planning and startup to maintenance and
upgrading.
Our specialists know when and where to act to keep the produc-
tivity and cost-effectiveness of your system running in top form.
■ Repairs and Spare Parts
■ Online Support In the operating phase of a ma-
The comprehensive information chine or automation system we
system available round the provide a comprehensive repair
clock via Internet ranging from and spare parts service ensur-
Product Support and Service & ing the highest degree of oper-
Support services to Support ating safety and reliability.
Tools in the Shop.
In Germany
http://www.siemens.com/ 0180 50 50 448 2)
automation/service&support
■ Technical Consulting
Support in the planning and de-
signing of your project from de-
tailed actual-state analysis,
target definition and consulting
on product and system ques-
tions right to the creation of the
automation solution. 1)
A 1) Get in touch with the sales contact in your region for questions about
these services. Our Helpline (tel.: +49 (0) 180 50 50 111) will also put you
through to the right contact or just visit our Internet site.
2) For country-specific telephone numbers go to our Internet site at:
http://www.siemens.com/automation/service&support
Appendix
Small card – great support Detailed information on the services offered is available on our
Internet site at:
The Automation Value Card is an integral component of the com-
prehensive service concept with which Siemens Automation and http://www.siemens.com/automation/service&support
Drives will accompany you in each phase of your automation Service & Support à la Card: Examples
project.
Technical Support
It doesn’t matter whether you want just specific services from our “Priority” Priority processing for urgent cases
Technical Support or want to purchase high-quality Support “24 h” Availability round the clock
Tools in our Online Shop, you can always pay with your Automa- “Extended” Technical consulting for complex questions
tion Value Card. No invoicing, transparent and safe. With your
Support Tools in the Support Shop
personal card number and associated PIN you can view the
“System Tools that can be used directly for configuration, anal-
state of your account and all transactions at any time. Utilities” ysis and testing
Services on card. This is how it’s done. “Applications” Complete topic solutions including ready-tested soft-
ware
Card number and PIN are on the back of the Automation Value “Functions & Adaptable blocks for accelerating your develop-
Card. When delivered, the PIN is covered by a scratch field, Samples” ments
guaranteeing that the full credit is on the card.
Appendix
■ Subject index
MICROMASTER MICROMASTER
D P
Demonstration case A/8 A/8 A/8 A/8 Parameter list 1/9 2/16 3/16 4/23
Derating data 1/6 2/7 3/7 4/7 Performance features 1/3 2/3 3/3 4/3
Description (inverter) 1/2 2/2 3/2 4/2 PROFIBUS module (option) - 2/15 3/14 4/20
Description (options) 1/8 2/9 3/10 4/12 Protection features 1/3 2/3 3/3 4/3
Design 1/2 2/2 3/2 4/2 Pulse encoder evaluation
DeviceNet module (option) - 2/15 3/14 4/20 module (option) - - - 4/20
Dimension drawings 1/10 2/17 3/17 4/24 Pulse frequency (derating) 1/6 2/7 3/7 4/7
Docu pack - 2/16 3/16 4/23
Documentation 1/9 2/16 3/16 4/23 S
Drive ES A/6 A/6 A/6 A/6 Selection and ordering data
(inverter) 1/7 2/8 3/9 4/9
Drive ES software A/6 A/6 A/6 A/6
Selection and ordering data
DriveMonitor 1/9 2/14 3/14 4/20
(option) 1/8 2/11 3/12 4/14
E Selection guide 0/4 0/4 0/5 0/5
Electromagnetic compatibility A/5 A/5 A/5 A/5 Service and support A/14 A/14 A/14 A/14
EMC filter (option) 1/8 2/11 3/13 4/14
SIDEMO (demonstration case system) A/6 A/6 A/6 A/6
Environment, resources and recycling A/2 A/2 A/2 A/2
STARTER 1/9 2/14 3/14 4/20
Export regulations A/18 A/18 A/18 A/18
Start-up tools 1/9 2/14 3/14 4/20
F Support A/14 A/14 A/14 A/14
Features 1/3 2/3 3/3 4/3
T
Filter (option) 1/8 2/11 3/13 4/14
Technical data (inverter) 1/6 2/6 3/6 4/6
Fuses (options) 1/9 2/13 3/12 4/16
Technical data (options) - 2/10 3/11 4/13
G Terminal connection diagram 1/5 2/5 3/5 4/5
General circuit diagram 1/4 2/4 3/4 4/4 Terminal connection plates (option) - 2/13 3/12 4/16
Getting Started Guide 1/9 2/16 3/16 4/23 Training center A/9 A/9 A/9 A/9
I Training courses A/9 A/9 A/9 A/9
Installation height (derating) 1/7 2/7 3/8 4/8
U
Integration with Drive ES A/6 A/6 A/6 A/6
UL listing A/5 A/5 A/5 A/5
International standards 1/2 2/2 3/2 4/2
A Internet (online services) A/13 A/13 A/13 A/13
Update service for Drive ES
V
A/7 A/7 A/7 A/7
Appendix
Appendix
The sales tax (value added tax) is not included in the prices. The deciding factors are the AL or ECCN export authorization
It shall be debited separately at the respective rate according to indicated on order confirmations, delivery notes and invoices.
the applicable legal regulations. Errors excepted and subject to change without prior notice.
In addition to the prices of products which include silver and/or
copper, surcharges may be calculated if the respective limits of
the notes are exceeded.
Prices are subject to change without prior notice. We will debit
the prices valid at the time of delivery.
The dimensions are in mm. Illustrations are not binding.
Insofar as there are no remarks on the corresponding pages,
– especially with regard to data, dimensions and weights given –
these are subject to change without prior notice.
Systems Engineering
Electrical Installation Technology Power supplies SITOP power KT 10.1
PDF: ALPHA Small Distribution Boards and ET A1 System cabling SIMATIC TOP connect KT 10.2
Distribution Boards MOBY Identification Systems KT 21
PDF: ALPHA Side-by-Side Switchgear Cabinets ET A3 Industrial Microcomputers SICOMP KT 51
PDF: BETA Modular Installation Devices ET B1
PDF: DELTA Switches and Outlets ET D1 System Solutions
PDF: GAMMA Building Management Systems ET G1 Applications and Products for Industry are part of the
interactive catalog CA 01
A&D/3U/En 27.10.03
The information provided in this catalog contains descriptions
or characteristics of performance which in case of actual use
do not always apply as described or which may change as a
result of further development of the products. An obligation
to provide the respective characteristics shall only exist if ex-
pressly agreed in the terms of contract. Availability and tech-
nical specifications are subject to change without notice.
Siemens AG