You are on page 1of 19

FIRE DETECTION

SYSTEMS
Your safety. Our technology.
HOCHIKI GLOBAL NETWORK AND PROJECTS
HOCHIKI AUSTRALIA
SALES TERRITORIES
ALL OCEANIA INCLUDING NZ,
PAPUA, FIJI

NTU Sports Center,


Taiwan

Qatar Financial Center


Tower, Qatar Middle East HOCHIKI TAIWAN

Eurostar Station Open Academy,


HOCHIKI MIDDLE EAST
St Pancras, London UK Norwich UK

HOCHIKI EUROPE HOCHIKI CORPORATION


Millburn Middle School,
NJ USA KENTEC

HOCHIKI AMERICA HOCHIKI INDIA

HOCHIKI MEXICO
Brisbane International
Airport, Australia
HOCHIKI BANGKOK

Melbourne International
Airport, Australia
Windser Barra Hotel, Vicom Center, NTT Singapore,
Rie de Janeiro Brazil Ho Chi Mihn Vietnam Singapore

HOCHIKI AUSTRALIA
HOCHIKI ASIA PACIFIC HOCHIKI JAKARTA

CONTENTS COMPANY OVERVIEW


03
Established early in the 20th Century, Hochiki is one of America and Europe ensure international continuity
HOCHIKI CORPORATE of the world’s leading manufactures of commercial of quality, service and supply. These regional centres
OVERVIEW and industrial fire detection and emergency lighting design and manufacture products and provide

04 HOCHIKI SYSTEM
solutions. With a heritage of innovative design and technical support suited to local standards
leading-edge technologies, Hochiki’s products have and customer requirements.
acquired global acceptance as the bench mark
Total commitment to meeting the needs of individual

06 TAKTIS FIRE 17 FIRE CONVENTIONAL


for high-integrity and long-term reliability.
national markets has reinforced the company’s global
28
WAVE WIRELESS DETECTORS
reputation, resulting in Hochiki products being
FIRE DETECTION PANEL COMPATIBILITY CHART
INTERNATIONAL COVERAGE REGIONAL COMMITMENT installed in many prestigious sites in over

08 TAKTIS VISION 21 ANALOGUE MARINE FIRE


80 countries worldwide.

29
SENSORS FOR Hochiki is an independent, multi-national, publicly
FIRENET, NFP, PHOENIX PANELS DETECTION listed company with over 1500 employees across Hochiki’s vision is to provide products to the highest
levels of quality and reliability. Complying with industry

10 NEW INTRINSICALLY
five manufacturing plants, thirty-one sales offices

22 32
TAKTIS VIRTUAL CONVENTIONAL AND DEVICES SAFE and eleven subsidiaries. The company’s global sales standards, the ultimate quality of Hochiki’s comprehensive
RESOURCE FOR SIGMA CP PANELS FIRE DETECTION turnover exceeds $750 million per annum. range of products virtually eliminates false alarms
and, combined with ease of installation, offers the

12 26 34
Hochiki invests in manufacturing innovation on greatest reliability with the lowest total cost of
ANALOGUE SENSORS AND CONVENTIONAL ANCILLARY
a continual basis to ensure customer satisfaction ownership possible in a modern life safety system.
DEVICES FOR TAKTIS AND DETECTORS EQUIPMENT
and production facilities in Japan, the United States
SYNCRO AS PANELS
HOCHIKI SYSTEM
HIGH INTEGRITY CONFIGURABLE NETWORK
Control Panel is manufactured by Hochiki Group Company,
Kentec Electronics Ltd. and distributed by Incite fire Pty Ltd.

LOOP 3 - LOOP 16
LOOP 3 - LOOP 8
(if fitted)

(if fitted)
Each loop is capable Each loop is capable
of hosting up to: of hosting up to:
127 devices, plus 127 devices, plus

LOOP 2 LOOP 1
LOOP 1 LOOP 2

127 Sounder Bases 127 Sounder Bases

TAKTIS FIRE TAKTIS FIRE


2 - 8 Loop Analogue 2 - 16 Loop Analogue
Addressable Control Panel Addressable Control Panel

TAKTIS VIRTUAL RESOURCE


VR ACCESS - A
 ccess data from TAKTIS VISION ANALOGUE SENSORS AND DEVICES
all your systems Configurable Fire
Alarm Repeater
VR VAULT - S
 ecure document vault
24 Vdc
VR SERVICE - C
 omplete service
management utility Up to 128 Panels/Repeaters
with automated data Media Gateway 10 Cards can be added to the network
transfer

VR PRINT - E
 liminates need for
panel mounted printers

Plug in slots
K772 K791 K792 K793
16 Channel 8 Way 8 Way Conventional 4 Way
I/O Board Relay Board Zone Board Sounder Board

Cloud Servers

GSM IP Dial-Up RS485 bus


TAKTIS VISION
Configurable Fire
Alarm Repeater
24 Vdc

TAKTIS FIRE TAKTIS FIRE


2 - 8 Loop Analogue 2 - 16 Loop Analogue
Addressable Control Panel Addressable Control Panel

4 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 5


TAKTIS FIRE TAKTIS OVERVIEW
With the increasing demands for power in fire detection Taktis Fire systems are scalable with Taktis Net
ANALOGUE ADDRESSABLE 2-16 LOOP CONTROL PANELS and alarm systems, Taktis Fire Control Panels are well Enhanced High Speed Networking. This allows up
placed to meet current and future needs. to 128 panels to be connected together as a fully
fault tolerant networked system with rapid inter
All panels are available with either a 5.25A, 24V power panel communications and up to 1.2km of standard
supply capable of charging up to 26Ah batteries or two core fire resistant cabling between nodes.
a 10.25A, 24V power supply capable of charging up
to 45Ah batteries. Taktis Fire can be supplied with a Each panel can be configured to display all or selected
remote power supply units, making the Control Panel events from any other panel allowing master/slave,
smaller and easier to install. multiple master/slave or peer to peer configuration.

Up to 500 mA are available for each detection Sophisticated network analysis tools provide
loop allowing for a generous quantity of loop the ability to identify connection problems instantly
powered devices. and the commissioning mode allows individual
panels to be prevented from transmitting events
The four sounder circuits are each capable of supplying to the network while maintaining communications.
up to 2.5A at 24V to audio and audio visual devices.
Adding a Taktis “Bridge” Network Card to your Taktis
Manage systems remotely from any location is a simple Panel or Taktis Network provides an interface between
and effective manner by configuring a Taktis Media existing Syncro and Taktis Control Systems providing
Gaterway communication device to the Virtual backward compatibility and a unique upgrade path.
Resource Servers and browser based software.

Taktis Media Gateway also provides the interface


between control systems, other products and
utilities such as PC graphics, Voyage Data Recorder
and a growing number of third party Taktis
compatible products.

Configurable serial ports will allow connection to BMS


systems using LonWorks, Modbus or BACnet protocols.

TAKTIS FEATURES
• AS7240-2, AS7240-4 and AS4428-3 • Over 20,000 cause and effect entries

• Up to 144 zone LED indicators on standard models • Up to 5000 software groups

• Support for up to 2000 zones • Maximum of 50,000 devices NOT and TIME
as well as COINCIDENCE, OR and AND operators
• Built in programmable I/Os
in cause and effects
•U
 p to 512 programmable I/O via optional plug
• Option to “invert” inputs and outputs
COMPATIBLE EQUIPMENT & EXTRAS in cards
• 9999 event log with one second resolution
• Modbus, LonWorks and BACnet interface options
• Powerful, standard configuration templates
•F
 ull colour, 7” 800 x 480 touch screen
graphical display • Network up to 128 panels

• Fully automatic display brightness adjustment • Configurable via USB port to PC or memory stick

• 80 character point and zone text • Optional Media Gateway communications card

• Over 4000 sub address points per panel

• Over 5000 cause and effect outputs


SELECTION OF I/O BOARDS TAKTIS NETWORK CARD VR TAKTIS MEDIA GATEWAY

6 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 7


TAKTIS VISION TAKTIS VISION OVERVIEW
Taktis Vision provides a means of allowing full Taktis Vision may be connected to the fire Control
ANALOGUE ADDRESSABLE ANNUNCIATORS display and optional control of the Taktis Fire Alarm Panels’ fault tolerant, ancillary RS485 bus or to the
Control Panel from a small and unobtrusive local fire alarm panel fault tolerant network using standard,
control station. fire rated cable offering flexibility in system wiring.

Based on an all new hardware and software platform, Available in several standard formats, Taktis Vision
the large, full colour graphical display with touch screen can be mounted directly onto a wall, be recessed using
functionality, delivers information on the status of our quick-fix adaptor frame or fully flush mounted.
the fire alarm system to single or multiple locations. Special enclosure finishes and colours are also available
to match existing decor.
Taktis Vision repeaters can be configured to offer
full display and control to replicate the functionality
of the fire Control Panel or to operate as a simple,
display only device for applications where access to
control the fire alarm system would be inappropriate.

For other annunciation and control applications,


Taktis Vision can be configured to provide customisable
switches and indications for a host of fire system
ancillary functions.

TAKTIS VISION FEATURES


•R
 obust, full colour, 7” 800 x 480 touch screen
graphical display

•F
 ull indication of all information displayed
at the fire Control Panel

• Automatic display brightness adjustment

• Silenceable internal sounder

COMPATIBLE EQUIPMENT & EXTRAS •C onnections Via:


- Control Panel RS485 bus
- Option to connect to Control Panel network

• Low current, 24 Vdc powered

• Slim compact construction

• Configurable functionality

• Configurable languages

• Optional Enable key-switch


TAKTIS NETWORK CARD MULTI PURPOSE
FLUSHING COLLAR

8 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 9


TAKTIS VIRTUAL RESOURCE TAKTIS VR OVERVIEW
To compliment the new, market leading range service and maintenance records, general notes
A COMPREHENSIVE SUITE OF SOFTWARE BASED TOOLS of control systems, Virtual Resource is a unique suite and any other documents related to the installed
of software tools aimed to deliver a whole new system that the user requires.
dimension in Life Safety System Management.

It provides system designers, integrators and service


VR SERVICE
companies with the ability to remotely access and VR Service provides a means to set up a comprehensive
comprehensively manage any system using intelligent fire alarm system servicing regime, adding benefit
analysis of data collected from those systems. End-users to both the end customer and service company.
and facilities managers can also greatly benefit from
the powerful feature set that comes with Virtual Resource. Site details can be imported from VR Access or added
and set up manually to create customer records.
Virtual Resource is based on technology successfully
trialled for many years and is one of the most technically Service frequency and device activation list schedules
advanced management tools for fire detection and can be set. Allocate resources such as travelling time
other safety systems on the market. and estimated timings to complete the service, and
include essential data for planning engineer activities.
With Virtual Resource, installers and service providers Service engineers can view and print their work schedules
are able to offer market leading functionality through along with site specific notes and previous service records
remote management and provide improved service directly from the system if required.
at a lower cost with greater efficiency.

The remote management features offered by Virtual VR PRINT


Resource can result in reduced fault call outs, improved VR Print is designed to replace panel mounted printers
servicing regimes, more effective maintenance, which are inherently difficult to manage and provide
reduction of unwanted alarms and improved overall very limited information. VR Print provides a secure
service to the end user. method of storing and recalling the control system
events via any web browser. The user can simply
Whether you are a service provider, building owner
view the systems events on line, print PDF reports
or facilities manager, change the way you think about
or download the data in formats, such as csv,
managing your Fire Detection System. With Taktis
for further data analysis.
Virtual Resources you can reduce costs, add value
and improve service integrity by implementing the
latest communication and analytical technologies.

VR ACCESS
TAKTIS VR FEATURES
Gain access to data from all of your systems,
• Unique Life Safety management utility
assess performance, check status’ and make
decisions based on facts, not assumptions. • Remote access to system data from anywhere

• Revenue driver for all business sizes


VR Access allows a Virtual Resource enabled fire
system to periodically report its status to the secure • Cut costs and drive up productivity
servers. VR Access subscribers can view the latest • Reduce environmental impact through technology
status report via any web enabled device.
• Modular application based tool set:
- VR Access - View and mange my projects
VR VAULT - VR Vault - Store and retrieve system
documentation
Subscribers to Virtual Resource can securely store - VR Service - Manage, add value and improve
system and site related documentation on our compliance
permanently backed up servers using VR Vault. - VR Print - Virtual printer

VR Vault provides a convenient and permanently • More


 to come…
More VR applications will be added to the
accessible storage location for all documentation
list providing users with further enhancement
related to an installation. This includes; installation to their value and revenue streams.
drawings, commissioning details and certificates,

10 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 11


ANALOGUE SENSORS AND DEVICES FOR TAKTIS AND SYNCRO AS PANELS

ANALOGUE SENSORS AND DEVICES YBN-R/3


• Electronics free

FOR TAKTIS AND SYNCRO AS PANELS


• Stainless steel contacts
A Common Mounting Base which is fully compatible with • Takes 2.5mm2 cables
ALK-ASN, ACA-ASN and ACB-ASN sensors. Supplied with


• Slim profile – only 8mm
square cable clamps for secure and reliable cable termination, • Rugged wiring contacts
it is also capable of driving a remote LED if required. • Facility for remote indicator
(Red version – YBO-R/3(RED) for use with CHQ-WS2 • Quick connection via square cable clamps
Hochiki’s comprehensive Analogue Addressable range is suitable for even the most Wall Sounder and CHQ-WSB Wall Sounder Beacon) • Available in RED for use with CHQ-WS2
Wall Sounder and CHQ-WSB Wall
demanding applications and incorporates high performance sensors, a wide selection Sounder Beacon

of input and output modules and ancillaries. All products use Hochiki’s high integrity
communications link.
• High Performance Chamber • Detects short circuits on loop
ALK-ASN YBO-R/SCI
• Twin fire LEDs allow 360° viewing • Status LED
A Photoelectric Smoke Sensor incorporating Hochiki’s unique • Locking mechanism (sensor to base) A Loop Isolator Base which is fully compatible with Hochiki • Connection of up to 127 per loop
High Performance Chamber, allows the sensor threshold • Variable sensitivity analog sensors, beacons, sounders and indicators. The unit • Quick connection via square cable clamps
level to be increased, improving the signal to noise ratio • Electronically addressed incorporates an amber LED to show when it is isolating • Available as a DIN Rail Module
and reducing susceptibility to false alarms. • Compatible Bases: YBN-R/3, a section of the loop. • Available in RED for use with CHQ-WS2
YBO-BS, YBO-BSB, YBO-R/SCI (Red version – YBO-R/SCI(RED) for use with CHQ-WS2 Wall Sounder & CHQ-WSB Wall
• Approval: AS7240.7 Wall Sounder & CHQ-WSB Wall Sounder Beacon) Sounder Beacon

• High Performance Chamber • Loop powered


ACA-ASN CHQ-WS2
• User selectable modes •S ingle loop address – addressed via
A Multi-Sensor incorporating a thermal element and a High • Incorporates optical and heat elements An Addressable Loop-Powered Wall Sounder providing the TCH-B100 hand held programmer
Performance Photoelectric Smoke Chamber. Has three modes • Twin fire LEDs allow 360° viewing 8 volume levels and 51 tones with a maximum output •V ariable sound output 90 ~ 102 dB(A)
controlled from the Control Panel, allowing either the optical • Pulsing/non-pulsing controlled from panel of up to 102 dB(A) (±2 dB(A)) with low current consumption. (±2 dB(A)) output at 1m
or thermal element or both to be active in making the • Variable sensitivity Special bases available: YBO-R/3(RED), YBO-R/SCI(RED), • Fits Hochiki standard or isolator base
fire decision. • Electronically addressed YBO-R/3(WHT) and YBO-R/SCI(WHT-SNDR). • Weatherproof kit available
• Compatible bases: YBN-R/3, •5 1 user-selectable tones (all tones
YBO-BS, YBO-BSB, YBO-R/SCI EN54-3 compatible)
• Approvals: AS7240.5 and AS7240.7 • Auto-shutdown mode available*
* Please ensure Control Panel compatibility

• User selectable modes As per CHQ-WS2 plus:


ACB-ASN CHQ-WSB
• Incorporates fixed temperature and rate • Variable flash frequency*
A Multi-Heat Sensor incorporating a variable fixed temperature of rise heat elements An Addressable Loop-Powered Wall Sounder Beacon as per • High intensity LED technology
heat element and a rate of rise heat element, both controlled • Twin fire LEDs allow 360° viewing the CHQ-WS2 but additionally featuring an integral beacon • Independent control of sounder and beacon*
from the Control Panel allowing either or both elements • Pulsing/non-pulsing controlled from panel within the horn which utilises high intensity LED technology. • Auto-shutdown mode available – can be set
simultaneously to be active in making the fire decision. • Electronically addressed Special bases available: YBO-R/3(RED), YBO-R/SCI(RED), independently for sounder or beacon*
• Compatible bases: YBN-R/3, YBO-R/3(WHT) and YBO-R/SCI(WHT-SNDR). * Please ensure Control Panel compatibility
YBO-BS, YBO-BSB, YBO-R/SCI
• AS7240.5 Classes A1, B and C

• User selectable modes • Designed for CHQ-WS2 and CHQ-WSB


ACB-ASNW WS2-WPK
• Incorporates fixed temperature and rate • Increases sounder IP rating from IP21
An IP67 Rated Waterproof Multi-Heat Sensor which can of rise heat elements A Weatherproof Back Box and Gasket Set for the CHQ-WS2 to IP65 (external use)
be used externally and is supplied with its own fixing base. • Twin fire LEDs allow 360° viewing Wall Sounder and the CHQ-WSB Wall Sounder Beacon, • Easy to install
Flying leads from the sensor connect directly to the loop • Pulsing/non-pulsing controlled from panel increases the IP rating of the sounder to IP65 for external use.
via waterproof connectors. • Electronically addressed
• IP67 rated
• Supplied with fixing base
• AS7240.5 Classes A1, B and C

12 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 13


ANALOGUE SENSORS AND DEVICES FOR TAKTIS AND SYNCRO AS PANELS ANALOGUE SENSORS AND DEVICES FOR TAKTIS AND SYNCRO AS PANELS

• Loop powered
YBO-BS CHQ-SIM
• Includes a single monitored input
• Single loop address – addressed • Small design for simple provision of a
An Addressable Loop-Powered Base Sounder providing automatically by Control Panel or via A Single Input Module designed to allow a single monitored monitored input onto an analogue loop
13 volume levels and 51 tones with a maximum output of up the TCH-B100 hand held programmer input to be connected to the Analogue loop. This provides a • Flying leads for easy installation
to 98 dB(A) (±2 dB(A)) with low current consumption. The unit • 50 ~ 98 dB(A) (±2 dB(A)) output at 1m compact, low-cost option where the installation of the larger • Addressed with TCH-B100 Hand
is designed to fit either the YBN-R/3 or the YBO-R/SCI* Bases. • Fits Hochiki standard or isolator base CHQ ‘Smart-Fix’ range of modules might be difficult. Held Programmer
(*From batch number 6044) and supports ESP sensors, beacons
and remote indicator
• 51 user-selectable tones
(all tones EN54-3 compatible)

• Loop powered
YBO-BSB
• Loop powered
• Single loop address, addressed by either
CHQ-DIM(SCI)
• Single loop address
An Addressable Loop-Powered Base Sounder Beacon Control Panel or TCH-B100 A Dual Input Module designed to interface to a variety • Two independent inputs for monitoring
providing 13 volume levels and 51 tones with a maximum • 50 ~ 98 dB(A) (±2 dB(A)) output at 1m of inputs such as door contacts, sprinkler flow/door switches of volt-free contacts
output of up to 98 dB(A) (±2 dB(A)) with low current •F  its Hochiki standard or isolator base and plant equipment. Also available as a DIN Rail mountable • Each input can be configured to monitor
consumption. The unit is designed to fit either the and supports ESP sensors, beacons version. Both models feature an integral Short-Circuit Isolator. either normally open or normally closed contacts
YBN-R/3 or the YBO-R/SCI* Bases. and remote indicators • DIN Rail version available
(*From batch number 6044) • 51 user-selectable tones • Both models feature an integral
(all tones EN54-3 compatible) Short-Circuit Isolator
• Beacons and sounders can be controlled
independently*
* Please ensure Control Panel compatibility

• High Intensity LED technology • Loop powered


CHQ-AB CHQ-DRC(SCI)
• 1 Hz flash frequency • Single loop address
An Addressable Loop-Powered Beacon with high-intensity • Addressable via TCH-B100 A Dual Relay Controller designed to provide two • Two independently controlled changeover relays
LEDs and a Fresnel lens design which produces a highly visible • Up to 127 devices per loop general-purpose relay outputs. Each output can be • Relays contact rated at 30 Vdc at 1 amp
flash. The casing exactly matches the Hochiki Analogue Sensor • Choice of 3 lens colours controlled independently and used to control dampers, plant • Auxiliary monitored input
range in shape and colour providing seamless integration. (red, amber and blue) and equipment shutdown. The monitored input can be used • DIN Rail version available
for local power supply fault monitoring or as a general-purpose • Both models feature an integral
input. Also available as a DIN Rail mountable version. Short-Circuit Isolator
Both models feature an integral Short-Circuit Isolator.

• High Intensity LED technology • Single loop address


CHQ-ARI CHQ-DZM(SCI)
• Addressable via TCH-B100 • Supports two independent zones
An Addressable Loop-Powered Remote Indicator, • Up to 127 devices per loop A Dual Zone Module designed to allow up to 60 conventional of conventional detectors
with high-intensity LEDs and a Fresnel lens design which detectors (30 per zone) to be interfaced to Hochiki’s Analogue • Both zones fully monitored for
produces a highly visible signal. The casing exactly matches Addressable system. Also available as a DIN Rail mountable short/open circuit
the Hochiki Analogue Sensor range in shape and colour version. Both models feature an integral Short-Circuit Isolator. • Requires an auxiliary 24 Vdc supply
providing seamless integration. The unit also features • DIN Rail version available
two monitored inputs. • Both models feature an integral
Short-Circuit Isolator

•S  upplies a nominal 24 Vdc at various • Loop-powered


CHQ-POM CHQ-MRC(SCI)
current levels, 2 mA to 32 mA in • Single loop address
A Powered Output Module designed to supply a nominal increments of 2 mA A Mains Relay Controller providing a single, mains rated relay • Single mains rated relay contact
24 Vdc at various, user-selectable current levels from 2 • User-selectable current output output for the control of such devices as dampers, extractors • Relay contact rated at 250 Vac at 5 amp
to 32 mA (in increments of 2 mA). The unit is small enough • Includes two monitored inputs or plant and equipment shutdown. The monitored input can (resistive) & 48 Vdc at 2 amp (resistive)
to be added to other third-party devices thereby allowing • Small design provides simple connectivity be used for local power supply fault monitoring or as a general- • Auxiliary monitored input
a range of equipment to be added to the Analogue loop. to Analog loop for third-party devices purpose input. Also available as a DIN Rail mountable version. • Screw terminals & flying leads for easy
The unit also features two monitored inputs. • Colour-coded flying leads for Both models feature an integral Short-Circuit Isolator. cable termination
simple installation • DIN Rail version available
• Addressed with TCH-B100 • Both models feature an integral
Hand Held Programmer Short-Circuit Isolator

14 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 15


ANALOGUE SENSORS AND DEVICES FOR TAKTIS AND SYNCRO AS PANELS

• Single loop address


CHQ-PCM(SCI)
• Loop powered
A Plant Control Module with four independent change-over • 4 change-over relay outputs
relay outputs, with N/O and N/C volt free contacts and four • 4 independent inputs for monitoring

WIRELESS FIRE DETECTION


inputs. These outputs can be driven separately by the fire alarm of volt-free contacts
Control Panel and can be used for the control of devices such • Each input can be configured to monitor
as dampers or for plant and equipment shutdown. Also available either normally open or normally closed


as a DIN Rail mountable version. Both models feature an integral contacts
Short-Circuit Isolator. • DIN Rail version available
• Both models feature an integral
Short-Circuit Isolator
Hochiki’s FIREwave system raises wireless fire detection and alarm systems to new levels
of reliability and flexibility. The system utilises the latest wireless technology to provide
• Single loop address
rapid, yet economic wireless fire system installations with minimal disturbance to its
CHQ-DSC(SCI)
• Two independent sounder circuits surroundings. Ideal for historic buildings, remote sites and any project where the
A Dual Sounder Controller, which has been designed to • Each circuit fully monitored for open
provide two sounder outputs (that can be driven separately) and short circuit faults installation of fire cabling is difficult, overly expensive or prohibited.
with full fault monitoring. The monitored input can be used for • Each alarm circuit fused at 1 amp
local power supply fault monitoring or as a general-purpose • Auxiliary monitored Input
input and features an integral Short-Circuit Isolator. • Loop powered
• Outputs are synchronised and can be RSM-WTM-AS
driven continuously or intermittently • Bi-directional wireless communication
A Wire to Wireless Translator Module which allows a wireless • Self optimising wireless amplitude
• 24 Vdc auxiliary power required
fire detection system to be interfaced directly onto the loop. and frequency
• Features an integral Short-Circuit Isolator
Fully loop-powered, the unit can support up to 32 wireless • Automatic wireless channel hopping
devices* or up to 7 RSM-EXP-AS Expander Modules**. • Fully intelligent
• High reliability and sensitivity
• Flexible on site device adjustment
• Exterior mounting protection
• Loop powered
CHQ-SZM(SCI) • Makes additions to existing wired systems
• Up to 6 conventional detectors
A Single Zone Monitor designed to allow up to 6 conventional easy and cost effective
• Single loop address
detectors to be interfaced to Hochiki’s Analogue Addressable • Approved to AS4428.9-2006, EN54-17, 18
• Remote LED output
system. Also available as a DIN Rail mountable version. • Fully monitored for short and
Both models feature an integral Short-Circuit Isolator. open circuit faults
• Bi-directional wireless communication
• DIN Rail version available RSM-EXP-AS
• Both models feature an integral • Self optimising wireless amplitude
A Wire to Wireless Expander Module which allows extended and frequency
Short-Circuit Isolator
signal coverage for the wireless system by boosting signal • Automatic wireless channel hopping
strengths from translators, to cover larger buildings • Fully intelligent
for example. Up to 7 RSM-EXP-AS Expander Modules** • High reliability and sensitivity
can be supported by a single RSM-WTM-AS Wireless • Flexible on site device adjustment
Translator Module. • Exterior mounting protection
• Makes additions to existing wired systems
• Fast response
HCP-E(SCI) easy and cost effective
• Integral Short-Circuit Isolator
A Manual Call Point Isolator fully compatible with Hochiki’s • Requires external power supply (9 ~ 27 Vdc)
• Bicolour status LED
Analogue Addressable protocol and featuring an integral • Approved to AS4428.9-2006, EN54-18
• Non-frangible element fitted
Short-Circuit Isolator (SCI). Features a bicoloured LED as standard (conforms to EN54)
to indicate either fire (red) or short-circuit (amber). • Addressed with TCH-B100
Also features plug-in wiring terminals for easy installation. Hand Held Programmer
*Maximum number of 16 output devices
Note – requires SR-BACKBOX if surface mounted (sold separately). • Surface or flush mounting
such as A/V or output modules.
• Weatherproof version available:
**Maximum of 5 child Expander Modules
HCP-W(SCI)
connected in cascade or a maximum
of 3 child Expander Modules connected
directly to the Translator Module
or another Expander Module

• Fast response
HCP-W(SCI)
• Integral Short-Circuit Isolator
An IP67 Weatherproof Manual Call Point Isolator fully • Bicolour status LED
compatible with Hochiki’s Analogue Addressable protocol • Non-frangible element fitted
and featuring an integral Short-Circuit Isolator (SCI). as standard (conforms to EN54)
Features a bicoloured LED to indicate either fire (red) • Addressed with TCH-B100
or short-circuit (amber). Also features plug-in wiring Hand Held Programmer
terminals for easy installation. • IP67 rated

16 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 17


FIRE WAVE WIRELESS FIRE DETECTION FIRE WAVE WIRELESS FIRE DETECTION

• Bi-directional wireless communication • Patented smoke chamber design


RSM-CIM-AS •S elf optimising wireless amplitude
ROD-E-AS
• Bi-directional wireless communication
A Wireless Conventional Interface Module which allows a zone and frequency A Wireless Intelligent Photoelectric Smoke Sensor • Adaptive signal processing helps
of wireless devices to be added to an existing conventional • Automatic wireless channel hopping with a patented smoke chamber ensuring optimal smoke with the elimination of false alarms
zone (or as a stand-alone zone). The zone is wired directly • Fully intelligent sensitivity with increased protection from airborne contamination • Automatic wireless channel hopping
to the RSM-CIM-AS which is then in turn supported • High reliability and sensitivity and background illumination. The sensor is fitted with a single • Fully intelligent with high reliability
by an RSM-EXP-AS Expander Module. • Flexible on site device adjustment omni-directional LED and a reed switch facility allowing testing and sensitivity
• Exterior mounting protection using a magnet. • Flexible on site device adjustment
• Makes
 additions to existing wired
• Makes additions to existing wired
systems easy and cost effective
systems easy and cost effective
•R equires external power supply for use
• Approved to AS7240.7-2004,
as stand-alone zone
AS4428.9-2006
• Approved to AS4428.9-2006, EN54-18

• Input circuits are monitored for fire • Thermistor-type heat sensing element
RSM-IP-AS RHD-E-AS
and fault conditions • Bi-directional wireless communication
A Wireless Single Channel Input Module which allows • Bi-directional wireless communication A Wireless Intelligent Rate of Rise Heat Sensor • Adaptive signal processing helps
the on/off status (alarm/fault) of an external device to be with a thermistor sensing element. The sensor is fitted
• Self optimising wireless amplitude with the elimination of false alarms
transmitted to a Control Panel wirelessly via an RSM-CIM-AS, with a single omni-directional LED and a reed switch
and frequency • Automatic wireless channel hopping
facility allowing testing using a magnet.
RSM-EXP-AS or RSM-WTM-AS. • Automatic wireless channel hopping • Fully intelligent with high reliability
• Fully intelligent and sensitivity
• High reliability and sensitivity • Flexible on site device adjustment
• Flexible on site device adjustment • Makes additions to existing wired
• Makes additions to existing wired systems systems easy and cost effective
easy and cost effective • Approved to AS7240.5-2004 class
• Approved to AS4428.9-2006, EN54-18 A1R, AS4428.9-2006

• Detects smoke and/or heat


RMD-E-AS
•C  ontacts can be configured as N/O or N/C
RSM-OP-AS • Bi-directional wireless communication
• Bi-directional wireless communication
A Wireless Single Channel Output Module which allows • Self optimising wireless amplitude A Wireless Intelligent Multi Sensor with a patented smoke • Adaptive signal processing helps
the Control Panel to activate/switch the circuits of an external and frequency chamber and thermistor heat sensing element. The sensor with the elimination of false alarms
device wirelessly via an RSM-EXP-AS or RSM-WTMAS. • Automatic wireless channel hopping is fitted with a single omni-directional LED and a reed • Automatic wireless channel hopping
The unit’s contacts can be configured to be normally open • Fully intelligent switch facility allowing testing using a magnet. • Fully intelligent with high reliability
or normally closed and switch at 30 Vdc/125 Vac at 2 A. • High reliability and sensitivity and sensitivity
• Flexible on site device adjustment • Flexible on site device adjustment
• Makes additions to existing wired • Makes additions to existing wired
systems easy and cost effective systems easy and cost effective
• Requires external power supply • Approved to AS7240.5/7-2004,
• Approved to AS4428.9-2006, EN54-18 AS4428.9-2006

•  Tones, adjustable volume up to 100 dB(A)


3
RSM-POM-AS
• Contacts can be configured as N/O or N/C
RSM-WS-AS (RED)
• Selectable output - 12 Vdc or 24 Vdc • Bi-directional wireless communication
A Wireless Powered Output Module which allows the Control • Bi-directional wireless communication A Wireless Intelligent Wall Sounder providing 3 tones • Automatic wireless channel hopping
Panel to activate/switch the circuits of an external device • Self optimising wireless amplitude with an adjustable volume level up to a maximum output • Easy and cost-effective additions
or system wirelessly via an RSM-CIM-AS, RSM-EXP-AS and frequency of 100 dB(A). Also available in white, RSM-WS-AS(WHT). to existing wired systems
or RSM-WTM-AS. The unit’s contacts can be configured • Automatic wireless channel hopping • Approved to AS4428.9-2006, EN54-3
to be normally open or normally closed and switch • Fully intelligent • IP21C
at 30 Vdc/125 Vac at 2 A. The unit can be configured • High reliability and sensitivity
to provide either a 12 Vdc or a 24 Vdc output. • Flexible on site device adjustment
• Makes additions to existing wired
systems easy and cost effective
• Approved to AS4428.9-2006, EN54-18

• 3 Tones, adjustable volume up to 100 dB(A)


RSM-CP-AS
• Bi-directional wireless communication
RSM-WS/W-AS (RED)
• Fully intelligent • Bi-directional wireless communication
A Wireless Resettable Manual Call Point which features • Utilises standard low cost lithium A Wireless Intelligent Weatherproof Wall Sounder providing • Automatic wireless channel hopping
a simulated glass front. When activated, a plastic ‘flag’ battery technology 3 tones with an adjustable volume level up to a maximum output • Easy and cost-effective additions
is displayed in the window of the unit; the supplied • Long battery life of 100 dB(A). Also available in white, RSM-WS/W-AS(WHT). to existing wired systems
key will reset the flag and unit. Supplied with back box. • Resettable Element
• Approved to AS4428.9-2006, EN54-3
• Clear ‘device activated’ warning flag
Weatherproof version also available (RSM-CP/W-AS). • IP66
• High reliability
• Automatic channel hopping
• Self optimising wireless amplitude
and frequency
• Weatherproof version available
• Approved to AS7240.11-2008,
AS4428.9-2006

18 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 19


FIRE WAVE WIRELESS FIRE DETECTION

ANALOGUE SENSORS FOR FIRENET,


• 5 Tones, adjustable volume up to 100 dB(A)
RSM-WSB-AS (RED) • Flash rate/light output of 1 Hz/1 Cd
A Wireless Intelligent Wall Sounder Beacon providing • Bi-directional wireless communication
5 tones with an adjustable volume level up to a maximum • Automatic wireless channel hopping

NFP, PHOENIX PANELS


output of 100 dB(A). Also provides a flash rate/light output • Easy and cost-effective additions
of 1 Hz/1 Cd and is available in white, RSM-WSB-AS(WHT). to existing wired systems
• Approved to AS4428.9-2006, EN54-3
• IP21C

• High Performance Chamber


ALK-AS
• Twin fire LEDs allow 360° viewing
A Photoelectric Smoke Sensor incorporating Hochiki’s unique • Locking mechanism (sensor to base)
• 5 Tones, adjustable volume up to 100 dB(A)
RSM-WSB/W-AS (RED) High Performance Chamber which allows the sensor threshold
• Variable sensitivity
• Flash rate/light output of 1 Hz/1 Cd
level to be increased, thereby improving the signal to noise
A Wireless Intelligent Weatherproof Wall Sounder Beacon • Bi-directional wireless communication • Electronically addressed
ratio and reducing susceptibility to false alarms.
providing 5 tones with an adjustable volume level up to • Automatic wireless channel hopping • Compatible bases: YBN-R/2NA, YBO-BS,
a maximum output of 100 dB(A). Also provides a flash • Easy and cost-effective additions YBO-BSB, YBO-R/SCI
rate/light output of 1 Hz/1 Cd and is available in white, to existing wired systems • Approval: AS7240.7
RSM-WSB/W-AS(WHT). • Approved to AS4428.9-2006, EN54-3
• IP66

• High Performance Chamber


ACA-E
• Incorporates optical & heat elements
A Multi-Sensor incorporating a thermal element • Twin fire LEDs allow 360° viewing
and a High Performance Photoelectric Smoke Chamber. • Variable sensitivity
• Electronically addressed
•3  2 Tones, adjustable volume from 90.1 • Compatible bases: YBN-R/2NA, YBO-BS,
RSM-BS-AS
to 92.4 dB(A) YBO-BSB, YBO-R/SCI
A Wireless Intelligent Base Sounder providing 32 tones • Bi-directional wireless communication • Approval: AS1603.1 & AS1603.2
as standard with a volume range of between 90.1 to 92.4 dB(A) • Automatic wireless channel hopping
at 1m. The pre-moulded base will accommodate any type • Easy and cost-effective additions
of FIREwave wireless detector, or a locking cover plate to existing wired systems
(RSM-C-AS). • Approved to AS4428.9-2006, EN54-3
• User selectable modes
ACB-AS
• Incorporates fixed temperature
A Multi-Heat Sensor incorporating a variable fixed temperature and rate of rise heat elements
heat element and a rate of rise heat element, both controlled • Twin fire LEDs allow 360° viewing
from the Control Panel allowing either thermal element • Electronically addressed
or both elements simultaneously to be active in making • Compatible bases: YBN-R/2NA,
the fire decision. YBO-BS, YBO-BSB, YBO-R/SCI
• Approval: AS1603.1. Class A, B, C and D
• 32 Tones, adjustable volume from 90.1
RSM-BSB-AS
to 92.4 dB(A)
A Wireless Intelligent Base Sounder Beacon providing • Flash rate of 1 Hz
32 tones as standard with a volume range of between 90.1 • Bi-directional wireless communication
to 92.4 dB(A) at 1m and a 1 Hz flash rate. The pre-moulded • Automatic wireless channel hopping
• User selectable modes
base will accommodate any type of FIREwave wireless • Easy and cost-effective additions ACB-ASW
• Incorporates Fixed temperature
detector, or a locking cover plate (RSM-C-AS). to existing wired systems An IP67 Rated Waterproof Multi-Heat Sensor which can be and rate of rise heat elements
• Approved to AS4428.9-2006, EN54-3 used externally and is supplied with its own fixing base which • Twin fire LEDs allow 360° viewing
is used to fix the sensor. Flying leads from the sensor connect • Electronically addressed
directly to the loop via waterproof connectors. • IP67 rated
• Supplied with fixing base
• Approval: AS1603.1 Class A, B, C and D

•P rotects wiring terminals on isolator


RSM-BSC
bases and base sounders
A Protective Lockable Cap which can be fitted to the • Easy to fit
• Electronics free
RSM-BSB-AS and RSM-BS-AS wireless base sounders YBN-R/2NA
• Stainless steel contacts
when either of these devices isn’t fitted with a sensor.
A Common Mounting Base which is fully compatible with • Takes 2.5mm2 cables
ALK-AS, ACA-E and ACB-AS sensors. Supplied with square • Slim profile – only 8mm
cable clamps for secure and reliable cable termination • Rugged wiring contacts
and is also capable of driving a remote LED if required. • Facility for remote indicator
• Quick connection via square cable clamps

20 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 21


CONVENTIONAL DETECTORS AND DEVICES FOR SIGMA CP PANELS

NEW CONVENTIONAL DETECTORS


• Integral remote indicator output
YBN-R/6
• Low Profile, only 8mm
A Model YBN-R/6 is a Conventional Detector Mounting Base • Rugged design and electronics free
associated with the NEW Sigma CP series range of detectors. • Quick connections via square cable clamps

AND DEVICES FOR SIGMA CP PANELS


• Accepts 2.5mm2 cables


• Bayonet slot, low insertion force for detectors

New Conventional Fire Detection. Hochiki’s Conventional Range offers one of the most
extensive product portfolios available, providing solutions for most conventional fire
applications, with a heritage of innovative design and leading edge technologies.
• Integral remote indicator output
• Remote indicator output YBO-R/6PA
SLV-AS3 • Rugged design
• Wide voltage range (9.5 ~ 30 Vdc) A Model YBO-R/6PA is a Conventional Detector Mounting
The SLV-AS3 is a Photoelectric Smoke Detector which is fully • Dedicated cable screen terminal
• Low profile design with one piece outer cover Base for 2 wire Systems where detectors and sounders
compatible with the majority of existing conventional systems. •Q  uick connection via square cable
• Twin fire LEDs allow 360° viewing are on the same zone cables.
The SLV-AS3 incorporates Hochiki’s unique High Performance clamps accepts up to 2.5mm2 cables
• Range of mounting bases
Photoelectric Smoke Chamber removing the need to use Ionisation • Bayonet slot, low insertion force for detectors
• Approval: AS7240.7
Detectors in the majority of applications. An integral third
terminal provides a remote indicator output.

• Electronic linear heat detection


DCD-A3
• Remote Indicator output
A Model DCD-A3 is a Rate of Rise Heat Detector with a 60°C • Wide voltage range (9.5 ~ 30 Vdc)
fixed temperature element using a thermistor and linearising • Twin fire LEDs allow 360° viewing
• Integral remote indicator
circuit to provide an accurate linear response heat detector. • Range of mounting bases YBO-R/6R
A third terminal provides integral remote indicator output. • Wide voltage range – can be used
• Approval: AS7240.5
A Conventional Latching Relay Mounting Base. in security systems
The DCD-A3 is ideal for use where medium ambient
Model YBOR/6R is a conventional detector mounting base • Rugged design
temperatures exist, such as drying rooms or where smoke
associated with the NEW conventional range of detectors. • Quick connections via square cable clamps
detectors are unsuitable because of the presence of steam
or cooking fumes such as in a kitchen. • Accepts 2.5mm2 cables
• Bayonet slot, low insertion force for detectors

• Electronic linear heat detection


DCD-C3
• Remote Indicator output
A Model DCD-C3 is a Rate of Rise Heat Detector with a 90°C • Wide voltage range (9.5 ~ 30 Vdc)
fixed temperature element using a thermistor and linearising • Twin fire LEDs allow 360° viewing
circuit to provide an accurate linear response heat detector. • Range of mounting bases
A third terminal provides integral remote indicator output. • Approval: AS7240.5
The DCD-C3 is ideal for use where medium ambient • Integral Remote Indicator
temperatures exist, such as drying rooms or where smoke
YBO-R/6RN
• Wide Voltage Range – can be used
detectors are unsuitable because of the presence of steam A Conventional Non-Latching Relay Mounting Base. in security systems
or cooking fumes such as in a kitchen. Model YBOR/6RN is a conventional detector mounting base • Rugged design
associated with the NEW conventional range of detectors. • Quick connections via square cable clamps
• Accepts 2.5mm2 cables
• Electronic linear heat detection • Bayonet slot, low insertion force for detectors
DFJ-A3
• Remote Indicator output
A Model DFJ-A3 is a 60°C Fixed Temperature Heat Detector • Wide voltage range (9.5 ~30 Vdc)
using a thermistor and linearising circuit to provide an accurate • Twin fire LEDs allow 360° viewing
linear response heat detector. A third terminal provides integral • Fixed temperature detector
remote indicator output. The DFJ-A3 is ideal for use where • Range of mounting bases
medium ambient temperatures exist, such as drying rooms • Approval: AS7240.5
or where smoke detectors are unsuitable because of the
presence of steam or cooking fumes such as in a kitchen. • Waterproof design – rated to IP67
DFG-60BLKJ(AS)
• Low profile shape
An IP67 Waterproof Conventional 60°C Fixed Temperature • Utilises a bimetallic strip to sense
Heat Detector with minimal standby current and high reliability. temperature change
• Electronic linear heat detection
DFJ-C3 Particularly suited to environments, which are exposed to high • No mounting base required
• Remote Indicator output
A Model DFJ-C3 is a 90°C Fixed Temperature Heat Detector levels of condensation or are hosed down. • Minimal standby current
• Wide voltage range (9.5 ~ 30 Vdc)
using a thermistor and linearising circuit to provide an accurate • Twin fire LEDs allow 360° viewing • Approval: AS7240.5
linear response heat detector. A third terminal provides integral • Fixed temperature detector
remote indicator output. The DFJ-C3 is ideal for use where medium • Full range of mounting bases
ambient temperatures exist, such as drying rooms or where • Approval: AS7240.5
smoke detectors are unsuitable because of the presence
of steam or cooking fumes such as in a kitchen.

22 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 23


CONVENTIONAL DETECTORS AND DEVICES FOR SIGMA CP PANELS CONVENTIONAL DETECTORS AND DEVICES FOR SIGMA CP PANELS

• Class 1 performance as defined in


DRD-AS BANSHEE EXCEL LITE (BEL-SBSB)
• Robust design
• BS EN54-10:2002 (range up to 25m) • Low current consumption
A Conventional Flame Detector designed for internal • Single IR technology An Electronic Conventional Sounder Beacon • Easy to install
use to detect large flames. The detection zone is a 90° • Robust and slim design which can be installed internally. • Xenon beacon technology
cone and the detection range is up to and including 25m. • Low current consumption • Maximum 110 dB(A) at 1m (dependant
• Easy to install on tone selected)
• Fits any of the CDX range of mounting bases • 32 user-selectable tones
• Twin LEDs for 360° view
• Compatible bases: YBN-R/6, YBO-R/6PA
• Approval: EN54-10

• Robust design
CSB-E
• Robust design
• Low current consumption
BANSHEE EXCEL LITE IP66 (BEL-SBDB)
• Low current consumption
A Conventional Base Sounder which has been designed • Easy to install An Electronic Conventional Sounder Beacon comes • Easy to install
to complement the Hochiki conventional range of detectors. • Maximum 93 dB(A) at 1m (Tone 1) with a deeper IP66 back box, which enables the unit
• Xenon beacon technology
Improved electronic design enables very low current to be installed externally.
• 32 user-selectable tones and 3 user- • Deep base provides IP66 protection
consumption whilst providing a range of tones and volumes selectable volumes • Maximum 110 dB(A) at 1m (dependant
selectable from each unit. • Utilises high intensity LEDs on tone selected)
• Lockable cap available (CS/CAP) • 32 user-selectable tones

• Robust design • High Intensity LED technology


CSBB-E CLB-E
• Low current consumption • Colour-matched to existing detector
A Conventional Base Sounder Beacon which has been • Easy to install A Conventional Beacon for use on 24V sounder circuits. and base ranges
designed to complement the Hochiki conventional range of • Maximum 93 dB(A) at 1m (Tone 1) The unit is fitted with a Fresnel lens and high-intensity LEDs, • Fits standard conventional base (YBN-R/6)
detectors. Improved electronic design enables very low current •32 user-selectable tones and a design which produces a highly visible flash. The casing
consumption whilst providing a range of tones and volumes 3 user-selectable volumes exactly matches the Hochiki conventional detector range
selectable from each unit. Features integral beacon. • Utilises high intensity LEDs in shape and colour providing seamless integration.
• Lockable cap available (CS/CAP)

• Robust design •S  upports either a ‘Frangible Glass’ element


BANSHEE EXCEL (BE-SSB) CCP-E
• Low current consumption or a ‘Non Frangible Plastic’ element
An Electronic Conventional Sounder which can • Easy to install The CCP-E is a conventional call point based upon the industry • Terminals can accommodate up to a 2.5mm2
be installed internally. • Maximum 110 dB(A) at 1m (dependant standard KAC world series housing and features easy to install, solid conductor
on tone selected) push fit wiring terminals. The unit can support either Frangible • Approved to EN54
• 32 user-selectable tones Glass element or Non Frangible Plastic element. • Rugged design
Note – requires SRBACKBOX if surface mounted (sold separately).

• Robust design •S
 upports either a ‘Frangible Glass’ element
BANSHEE EXCEL IP66 (BE-SDB) CCP-W
• Low current consumption or a ‘Non Frangible Plastic’ element
An Electronic Conventional Sounder comes with a deeper • Easy to install The CCP-W is a IP67 Weatherproof conventional call point •T
 erminals can accommodate up to a 2.5mm2
IP66 back box, which enables the unit to be installed externally. • Deep base provides IP66 protection based upon the industry standard KAC world series housing solid conductor
• Maximum 110 dB(A) at 1m (dependant and features easy to install, push fit wiring terminals. The unit • Approved to EN54
on tone selected) can support either Frangible Glass element or Non Frangible • Weatherproof IP67
• 32 user-selectable tones Plastic element. • Rugged design
Note – requires SR-BACKBOX if surface mounted (sold separately).

24 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 25


CONVENTIONAL DETECTORS

CONVENTIONAL DETECTORS
• 5 – 100m range
SPC-AS
• Automatic compensation
A Conventional Beam Smoke Detector that consists of an • Automatic signal strength adjustment


emitter and receiver that cover a distance of 5 – 100m providing • Features a Latching or Non-Latching
a maximum coverage of 1500m2. Features an automatic signal Fault Relay
strength adjustment facility and is also available with a latching • Can be interfaced onto Hochiki Analogue
or a non-latching relay. system via CHQ-DZM or CHQ-SZM
Conventional Fire Detection. Hochiki’s Conventional Range offers one of the most extensive • Approval: AS7240.12
product portfolios available, providing solutions for most conventional fire applications,
with a heritage of innovative design and leading edge technologies.

• Remote indicator output


SLV-AS
• High Performance Chamber
YBO-R/4A
• Low profile design with one piece outer cover • 10mm Profile
A Conventional Photoelectric Smoke Detector, which is fully • Twin fire LEDs allow 360° viewing A Conventional Detector Mounting Base with remote • Rugged design and electronics free
compatible with the majority of existing conventional systems. • Remote Indicator output (with YBO-R/4A base) LED function associated with SLV-AS, DCD-A, DCD-C, • Quick connections via square cable clamps
• Compatible bases: YBO-R/4A and YBN-R/4C DFJ-60B, DFJ-90D. • Accepts 2.5mm2 cables
• Approval: AS1603.2 • Bayonet slot, low insertion force for detectors

• Electronic linear heat detection


DCD-A
• Twin fire LEDs allow 360° viewing
A Conventional Rate of Rise Heat Detector incorporating a • Remote Indicator output (with YBO-R/4A base)
60°C fixed temperature element. The thermistor and linearising • Compatible bases: YBO-R/4A and YBN-R/4C
circuit provide an accurate linear response heat detector. • Low Profile, only 8mm
• Approval: AS1603.1 YBN-R/4C
• Rugged design and electronics free
A Conventional Detector Mounting Base without remote • Quick connections via square cable clamps
LED function associated with SLV-AS, DCD-A, DCD-C, • Accepts 2.5mm2 cables
DFJ-60B, DFJ90D. • Bayonet slot, low insertion force for detectors

• Electronic linear heat detection


DCD-C
• Twin fire LEDs allow 360° viewing
A Conventional Rate of Rise Heat Detector incorporating a • Remote Indicator output (with YBO-R/4A base)
90°C fixed temperature element. The thermistor and linearising • Compatible bases: YBO-R/4A and YBN-R/4C
circuit provide an accurate linear response heat detector. • Approval: AS1603.1

• Waterproof design – rated to IP67


DFG-60BLKJ (AS)
• Low profile shape
An IP67 Waterproof Conventional 60°C Fixed Temperature • Utilises a bimetallic strip to sense
Heat Detector with minimal standby current and high reliability. temperature change
Particularly suited to environments, which are exposed to high • No mounting base required
levels of condensation or are hosed down. • Minimal standby current
• Electronic linear heat detection
DFJ-60B • Approval: AS7240.5
• Twin fire LEDs allow 360° viewing
A Conventional 60°C Fixed Temperature Heat Detector • Fixed temperature detector
using a thermistor and linearising circuit to provide • Remote indicator output (YBO-R/4A base)
an accurate linear response heat detector. • Compatible bases: YBO-R/4A and YBN-R/4C
• Approval: AS1603.1

• Class 1 performance as defined in


DRD-AS
• BS EN54-10:2002 (range up to 25m)
A Conventional Flame Detector designed for internal use • Single IR technology
to detect large flames. The detection zone is a 90° cone • Robust and slim design
DFJ-90D • Electronic linear heat detection and the detection range is up to and including 25m. • Low current consumption
• Twin fire LEDs allow 360° viewing • Easy to install
A Conventional 90°C Fixed Temperature Heat Detector
• Fixed temperature detector • Fits any of the CDX range of mounting bases
using a thermistor and linearising circuit to provide
• Remote indicator output (YBO-R/4A base) • Twin LEDs for 360° view
an accurate linear response.
• Compatible bases: YBO-R/4A and YBN-R/4C • Compatible bases: YBN-R/6, YBO-R/6PA
• Approval: AS1603.1 • Approval: EN54-10

26 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 27


MARINE FIRE DETECTION

HOCHIKI CONVENTIONAL DETECTORS MARINE FIRE DETECTION


PANEL COMPATIBILITY CHART


(MAXIMUM NUMBER OF DEVICES ALLOWED PER AZF) All marine fire detection products have been approved by either Lloyds Register
or Germanischer Lloyd. They are ideal for marine use, such as on ships and oil rigs.
DETECTOR

MANUFACTURER PANEL MODEL NUMBER

THERMAL

THERMAL

THERMAL

THERMAL
DFJ-60B

DFJ-90D

SIJ-ASN
SLV -AS
SLR-AS
SMOKE

SMOKE
DCD-C
DCD-A
• Removable, High Performance Chamber
ALG-ENM
• Twin fire LEDs allow 360° viewing
ZONESENSE 40 40 40 40 40 40 A Marine Approved Analogue Addressable Photoelectric • Locking mechanism (sensor to base)
AB1000, AB800, AB2000, AP1542 39 39 39 39 39 31 Smoke Sensor incorporating Hochiki’s unique High Performance • Variable sensitivity
Chamber which allows the sensor threshold level to be increased, • Electronically addressed
AP 1671 FIREFINDER 40 40 40 40 40 40 thereby improving the signal to noise ratio and reducing • Pulsing/non-pulsing controlled from panel*
AMPAC AB3000, AP1417, 40 40 40 40 40 40 susceptibility to false alarms. • Approved to MED by GL
XP 95 DEVICE 40 40 40 40 40 40 * Please ensure Control Panel compatibility

AB04 33 33 33 33 33 26

AB40 23 23 16 16 N/C N/C


FFE MCP-002, 10000 LAM, 10000 DCM 40 40 40 40 40 33
8070, SCP-90,FB-208/56 40 40 40 40 40 40
CHUBB • User selectable modes
FFE
HOCHIKI CHQ-DZM(CHQ-Z)FIELD DEVICE 30 30 30 30 30 30 AC B-EM
• Incorporates fixed temperature and rate
NFP/PHOENIX CCI CARD 40 40 40 40 40 40 A Marine Approved Analogue Addressable Multi-Heat Sensor of rise heat elements
FIRENET CCI CARD 40 40 40 40 40 40 incorporating a variable fixed temperature heat element and • Twin fire LEDs allow 360° viewing
a rate of rise heat element, both controlled from the Control • Pulsing/non-pulsing controlled from panel*
ZJ1000 40 40 40 40 40 39 Panel allowing either thermal element or both elements • Electronically addressed
INERTIA
2400 & 008 40 40 40 40 40 40 simultaneously to be active in making the fire decision. • Approved by LPCB to Classes A, B & C
• Approved to MED by GL
MODEL 128 29 29 29 29 29 23
* Please ensure Control Panel compatibility
BROOKS MODEL 199 18 18 18 18 18 14
PANALECT 2010V 40 40 40 40 40 40
MICROFIRE 40 40 40 40 40 40
F4000, F3200 40 40 40 40 40 40
• Electronics free
F5000 AZF 301 1K8 40 40 40 40 40 37 YBN-R/3M
• Supports ESP marine approved sensors
VIGILANT
F5000 AZF 301 2K7 31 31 31 31 31 25 A Marine Approved Common Mounting Base which is fully • Stainless steel contacts
compatible with Hochiki’s analogue range of marine approved • Takes 2.5mm2 cables
F08 N/C N/C N/C N/C N/C N/C
sensors. Supplied with square cable clamps for secure and • Slim profile – only 8mm
2600 & 888 40 40 40 40 40 40 reliable cable termination and is also capable of driving • Rugged wiring contacts
a remote LED if required. • Facility for remote indicator
NOTIFIER CFP800 20 20 25 25 20 22
• Quick connection via square cable clamps
AFP-100, AFP-200, MMX-2, ID-200, AM2020 40 40 40 40 40 40 • Approved to MED by GL
ZP-E50 40 40 40 40 40 40

ZITON ZP5 AS2 40 40 40 40 40 40


ZP5 AS1 34 34 23 23 34 34

MATTHEWS FIRE FYRTEL MICRO 900 35 35 25 25 35 40


• Detects short circuits on loop
YBO-R/SCIM
• Status LED
DIGITRON SERIES 86 40 40 40 40 40 40
A Marine Approved Loop Isolator Base which is fully compatible • Connection of up to 127 per loop
with Hochiki’s Analogue Range of Marine Approved Sensors. • Supports marine approved sensors
HONEYWELL FS90 & 809A 40 40 40 40 40 40
The unit incorporates an amber LED to show when • Quick connection via square cable clamps
MICRO 1000 40 40 40 40 40 40 it is isolating a section of the loop. • Approved to MED by GL
O’DONNELL
GRIFFEN MXL CZM-1 23 23 23 23 23 19
4020 40 40 40 40 40 40

SIMPLEX 2120 28 28 28 28 28 23
4100 33 33 33 33 33 27

28 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 29


MARINE FIRE DETECTION MARINE FIRE DETECTION

• Loop powered
CHQ-DIM/M (SCI) SLR-E3NM
• High Performance Chamber
• Single loop address • Remote indicator output
A Marine Approved Analogue Addressable Dual Input • Two independent inputs for monitoring A Marine Approved Conventional Photoelectric Smoke • Wide voltage range (9.5 ~ 30 Vdc)
Module designed to interface to a variety of inputs such of volt-free contacts Detector which is fully compatible with the majority • Low profile design with one piece outer cover
as door contacts, sprinkler flow/door switches and plant • Each input can be configured to monitor of existing Marine Conventional systems and incorporates • Twin fire LEDs allow 360° viewing
equipment. Features an integral Short-Circuit Isolator. either normally open or normally a remote indicator output. • One master base
closed contacts • Approved by LPCB, LR and GL
• Features an integral Short-Circuit Isolator
• Approved to MED by GL

• Loop powered
CHQ-DRC/M (SCI)
• Electronic linear heat detection
• Single loop address
DCD-AE3M
• Remote indicator output
A Marine Approved Analogue Addressable Dual Relay • Two independently controlled A Marine Approved Conventional Rate of Rise Heat Detector • Wide voltage range (9.5 ~ 30 Vdc)
Controller designed to provide two general-purpose relay changeover relays incorporating a 90°C fixed temperature element. The thermistor • Twin fire LEDs allow 360° viewing
outputs, each output can be controlled independently • Relays contact rated at 30 Vdc at 1 amp and linearising circuit provide an accurate linear response • Approved by LPCB, LR and GL
and used to control dampers, plant and equipment shutdown. • Auxiliary monitored input heat detector. A third terminal provides integral remote
The monitored input can be used for local power supply fault • Features an integral Short-Circuit Isolator indicator output.
monitoring or as a general-purpose input. Features an integral • Approved to MED by GL
Short-Circuit Isolator.

• Single loop address • Electronic linear heat detection


CHQ-DSC/M (SCI) DCD-CE3M
• Two independent sounder circuits • Remote indicator output
A Marine Approved Analogue Addressable Dual Sounder • Each circuit fully monitored for open A Marine Approved Conventional Rate of Rise Heat Detector • Wide voltage range (9.5 ~ 30 Vdc)
Controller, which has been designed to provide two sounder and short circuit faults incorporating a 90°C fixed temperature element. The thermistor • Twin fire LEDs allow 360° viewing
outputs (that can be driven separately) with full fault monitoring. • Each alarm circuit fused at 1 amp and linearising circuit provide an accurate linear response • Approved by LPCB, LR and GL
The monitored input can be used for local power supply fault • Auxiliary monitored Input heat detector. A third terminal provides integral remote
monitoring or as a general-purpose input. Features an integral •O utputs are synchronised and can be indicator output.
Short-Circuit Isolator. driven continuously or intermittently
• 24 Vdc auxiliary power required
• Features an integral Short-Circuit Isolator
• Approved to MED by GL

• Loop powered • Integral remote indicator output


CHQ-SZM/M (SCI) YBN-R/6M
• Up to 6 conventional detectors • Low profile, only 8mm
A Marine Approved Analogue Addressable Single • Single loop address A Marine Approved Conventional Detector Mounting Base • Rugged design
Zone Monitor designed to allow up to 6 marine approved • Remote LED output for the CDX marine approved range of detectors and fully • Electronics free
conventional detectors to be interfaced to Hochiki’s Analogue • Fully monitored for short compatible with the majority of existing conventional • Quick connections via square
Addressable system. Features an integral Short-Circuit Isolator. and open circuit faults fire alarm Control Panels. cable clamps
• Features an integral Short-Circuit Isolator • Accepts 2.5mm2 cables
• Approved to MED by GL •B ayonet slot, low insertion force
for detectors
• Approved by LR and GL

• Fast response •4 glanded cable entry holes (glands not supplied)
HCP-EM MBB-1
• Status LED • Colour matched
A Marine Approved Analogue Addressable Manual Call Point • Non-frangible element fitted as standard A Marine Back Box providing a splash proof and secure fixing • Approved sensor and base range
fully compatible with Hochiki’s Analogue Addressable protocol (conforms to EN54) for the Hochiki Analogue and conventional marine approved • Provides moisture and dust resistant fixing
and featuring plug-in wiring terminals for easy installation. • Addressed with TCH-B100 Hand range of sensors and detectors and their associated bases. • Ideal for bulk-head fixing
Note – requires SR-BACKBOX if surface mounted (sold separately). • Held Programmer Provides an aesthetically pleasing solution where surface • Approved by LR and GL
• Surface or flush mounting fixed devices are required. The housing supports four • Non-marine use version available (SBB-1)
• Weatherproof IP67 version 20mm glanded entries for cabling access.
available (HCP-WM)
• Approved to MED by GL

30 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 31


INTRINSICALLY SAFE FIRE DETECTION

INTRINSICALLY SAFE FIRE DETECTION


•S  upports either a ‘Frangible Glass’ element
CCP-W-IS
or a ‘Non Frangible Plastic’ element
A Conventional Manual Call Point designed for use • Terminals can accommodate up to a 2.5mm2


in hazardous areas and based upon the industry solid conductor
standard KAC world series housing. • Approved to EN54 part 12
• Rugged design

Hochiki’s Intrinsically Safe Conventional range of products has been designed around
•A TEX classification to II 1G EEx ia IIC T4

the existing world-proven Hochiki conventional range. The detectors have been approved
for hazardous area use by both LPCB and Germanischer Lloyd.

• High Performance Chamber


SLR-E-IS CHQ-DZM (SCI)-IS
• Single loop address
• Twin fire LEDs allow 360° viewing •S upports two independent zones
A Conventional I.S. Photoelectric Smoke Detector designed • Supported by a range of barriers A Dual Zone Module which is fully compatible with of Hochiki I.S. conventional detectors
for use in hazardous areas. Incorporates a remote indicator • Remote indicator output Hochiki’s ESP Analogue Addressable protocol and I.S. •B oth zones fully monitored for
output and a removable chamber for easy maintenance. • IECEx certification to: II 1G EEx ia IIC T5 equipment. The module will allow connection of up to short/open-circuit
(Tamb=55°C) 40 Hochiki I.S. conventional detectors (20 per zone) through • Requires an auxiliary 24 Vdc supply
• Suitable for installation in areas at category 1 a Galvanic Isolator, which are then fully monitored for open • DIN Rail version available
(inc. all lower categories) and short circuit. Also available as a DIN Rail mountable version. •B oth models feature an integral
• Approved by BASEEFA Both models feature an integral Short-Circuit Isolator. Short-Circuit Isolator

• Twin fire LEDs allow 360° viewing


DCD-1E-IS MTL7787+
•S
 imple installation onto standard DIN
• Electronics free mounting base ‘top-hat’ railing
A Conventional I.S. Rate of Rise Heat Detector designed • Remote indicator output A Zener-Diode Barrier which is intrinsically safe and •R
 emovable colour-coded terminals
for use in hazardous areas. Incorporates a remote indicator • IECEx certification to: II 1G EEx ia IIC zone-powered, for use in conventional fire detection for easy connection
output and a 60°C fixed temperature element. T5 (Tamb=55°C) systems for protection within hazardous areas. Certified ‘ia’ •C
 an accommodate conductors up to 2.5mm2
•S uitable for installation in areas at category 1 for all zones and ‘IIC’ for all explosive atmospheres. • Supports up to two zones of I.S. products
(inc. all lower categories)
• Approved by BASEEFA

• Low profile, only 8mm


YBN-R/4 (IS) MTL7728+
•S  imple installation onto standard DIN
• Rugged design ‘top-hat’ railing
A Conventional Detector Mounting Base associated • Dedicated cable screen terminal A Zener-Diode Barrier which is intrinsically safe and • Simplified installation and maintenance
with the Hochiki conventional range of Intrinsically • Accepts from 1 to 2.5mm2 cables zone-powered, for use in conventional fire detection using plug-in connectors
Safe Detectors and is fully compatible with the majority •Q uick connection via square cable clamps systems for protection within hazardous areas. Certified ‘ia’ • Input circuit protected against reverse polarity
of existing conventional fire alarm Control Panels. • Electronics free for all zones and ‘IIC’ for all explosive atmospheres. • Supports 2 zones of I.S. Detectors

•S  upports either a ‘Frangible Glass’ element


CCP-E-IS KFDO-CS-EX2.51P ISOLATED BARRIER
• 2-channel isolated barrier
or a ‘Non-Frangible Plastic’ element • 24 Vdc supply (Loop powered)
A Conventional Manual Call Point designed for use • Terminals can accommodate up to a 2.5mm2 This Isolated Barrier is used for intrinsic safety applications. • Current input/output 0 mA ~ 40 mA
in hazardous areas and based upon the industry solid conductor It transfers DC signals from fire alarms, smoke alarms, and • I/P or transmitter power supply
standard KAC world series housing. • Approved to EN54 part 12 temperature sensors in hazardous areas. It can also be used • Accuracy 1%
• Rugged design to control I/P converters, power solenoids, LEDs, and audible • Reverse polarity protection
• ATEX classification to II 1G EEx ia IIC T4 alarms. Reverse polarity protection prevents damage to the • Up to SIL2 acc. to IEC 61508
isolator caused by faulty wiring. Since this isolator is loop
powered, use the technical data to verify that proper
voltage is available to the field devices.

32 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 33


ANCILLARY EQUIPMENT

ANCILLARY EQUIPMENT
• Designed to house up to 4 Hochiki DIN modules
SMB-3
• Quick-release screws
An IP66 rated, grey (RAL7035) enclosure designed for • Polyurethane gasket provides IP66 protection
use with the Hochiki range of DIN modules. Supplied with • Corrosion free, resistant to most alkaline and acid
a transparent black lid as standard. The unit is supplied • Temperature resistance to +70°C,
with a DIN Rail section (plus fixings) and will accept impact resistant, and non-flammable
up to four Hochiki DIN Rail modules, side-by-side. • 20 metric knock-outs
• Install quickly and easily • Supplied with DIN Rail and fixings
DH-98-ASA AND DH-98-ASC
• No screens or filters to clean
A Duct Probe Housing associated with analogue ALK-AS, • Rugged gray steel back box with clear cover
ALK-ASN detectors and conventional SLV-AS detector
to be mounted on the outside of an air duct for the purpose
of monitoring the air within the duct. (Shown with sensor
fitted – not supplied).
•4  glanded cable entry holes
SBB-1
(glands not supplied)
A Back Box providing a splash proof and secure fixing • Colour matched
which for the Hochiki Analogue and conventional range • Approved sensor and base range
of sensors and detectors and their associated bases. • Provides moisture and dust resistant fitting
Provides an aesthetically pleasing solution where surface • Ideal for bulk head fitting
• Lightweight design
TC H-B100 fixed devices are required. The housing supports four • Marine use (MBB-1)
• Quick and reliable addressing
20mm glanded entries for cabling access.
A Hand Held Address Programmer designed to address •O ver 8000 address settings from
the range of Sensors and other addressable devices such one battery
as the YBO-BS Base Sounder. Designed to be light, robust • Displays sensor analogue value
and easy to use it operates from a single PP3 size 9v battery
which can provide up to 8000 operations. (Shown with
sensor fitted – not supplied).

• Provides glanded cable connections


CHQ-BAC KBOX
• Robust design
The CHQ-BACKBOX is designed for installations where • Compatible with all CHQ Modules
the CHQ range of modules - CHQ-DIM(SCI), CHQ-SZM(SCI),
•S  imple to use hand held unit with CHQ-DZM(SCI), CHQ-DSC(SCI), CHQ-MRC(SCI),
16091 CHQ-DRC(SCI) and CHQ-PCM – require mounting
rechargeable NiCd battery pack and charger
A Hand Held Flame Detector Tester providing a flame-free • Tests many Flame Sensors Types UV, UV/IR, within a glanded enclosure.
method of testing flame detectors UV/IR3, IR3, IR2, IR
• Range typically 3 and beyond
•S electable optical output intensity
with LED bar graph indication

•A  llows the PCB component of a CHQ Module


CHQ-ADAPTOR
to be housed in an enclosure
• Quick-release screws The CHQ-ADAPTOR is designed to allow the “Smart-Fix” • Footprint matches older enclosure sizes
SMB-1 range of CHQ Modules to be housed in existing enclosures
• Polyurethane gasket provides IP66 protection
An IP66 rated, grey (RAL7035) enclosure designed for use • Corrosion free, resistant to most alkaline originally designed for the first generation CHQ-OEM
with the Hochiki range of modules. Supplied with a transparent and acid Modules by modifying the ‘footprint’ of the unit.
black lid as standard. Used in conjunction with the SMBADAPTOR • Temperature resistance to +70°C,
this enclosure can house any of the PCB assemblies from impact resistant, and non-flammable
the Hochiki Smart-Fix module range. • 32 knock-outs

• Designed to house up to 6 Hochiki DIN modules •P rotects wiring terminals on isolator
SMB-2 SI-CAP
• Quick-release screws bases and base sounders
An IP66 rated, grey (RAL7035) enclosure designed for use • Polyurethane gasket provides IP66 protection A Protective Cap which can be fitted to the YBO-R/SCI isolator • Easy to fit
with the Hochiki range of DIN modules. Supplied with a transparent • Corrosion free, resistant to most alkaline base range, the YBO-BS base sounder or the YBO-BSB base
black lid as standard. The unit is supplied with a DIN Rail section and acid sounder beacon – when either of these devices isn’t fitted
(plus fixings) and will accept up to six Hochiki DIN Rail • Temperature resistance to +70°C, with a sensor.
modules, side-by-side. impact resistant, and non-flammable
• 32 knock-outs
• Supplied with DIN Rail and fixings

34 | FIRE DETECTION SYSTEMS FIRE DETECTION SYSTEMS | 35


ANALOGUE CONVENTIONAL
Hochiki’s Analogue range incorporates Hochiki’s Conventional range covers
a variety of high performance sensors, one of the most extensive product
modules and ancillary devices to increase portfolios, and provides solutions
the ease of routine maintenance and for most conventional fire detection
commissioning. Enhanced System applications, as well as security
Protocol (ESP) applies Hochiki’s systems due to its wide voltage
high integrity communication range (9.5 ~ 30 Vdc).
link to all products in the range.

INTRINSICALLY SAFE & MARINE WIRELESS


For demanding environments, Hochiki also caters for hybrid
Hochiki has a range of industrial, sites with the firewave range which
intrinsically safe and explosion proof integrates wireless technology into
conventional products, as well as a Hochiki’s Analogue hardwired system
marine product range that encompasses to provide maximum flexibility
options to match both Analogue and meet specific site requirements.
and Conventional products ranges.

HOCHIKI AUSTRALIA PTY LTD


Address: Block Y, Unit 1 Regents
Park Estate, 391 Park Road,
Regents Park NSW 2143
P +61 2 9738 5566
F +61 2 9743 7133
www.hochikiaustralia.com
E sales@hochikiaustralia.com

DISTRIBUTED BY
For NSW, ACT For VIC, TAS, SA, WA For QLD, NT
Incite fire Pty Ltd Incite fire Pty Ltd eFIRE Technologies Pty Ltd
Block Y, Unit 1 Regents Park Estate, Unit 120 - 45 Gilby Road, 25 Jeays Street,
391 Park Road, Regents Park NSW 2143 Mt Waverley VIC 3149 Bowen Hills QLD 4006
P 1300 INCITE (1300 462 483) P +61 3 9544 2211 P +61 7 3252 5366
+61 2 9644 7144
F +61 2 9644 7255 F +61 3 9544 2212 F +61 7 3252 4099
E sales@incitefire.com.au E salesvic@incitefire.com.au E sales@efiretechnologies.com.au

You might also like