You are on page 1of 23

Siemens Enterprise Communications

Test Report of Certification

VIERLING Communications GmbH

ECOTEL GSM3-
GSM3-3x

with

HiPath 4000 V4

Test Status:
Release Date: 2009-mm-dd

Siemens Enterprise Communications GmbH & Co. KG 2008

Issued by:
Siemens Enterprise Communications GmbH & Co.KG
Hofmannstraße 51
D-81359 Munich

Siemens Enterprise Communications GmbH & Co. KG is a Trademark Licensee of Siemens AG

Copying of this document and giving it to others and the use or communication of the contents thereof, are forbidden without express
authority. Offenders are liable to the payment of damages. All rights reserved in the event of the grant of a patent or the registration of a
utility model or design.

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document: rep_vierling_ecotel_GSM3-3_h4kv40.doc
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

Contents:
1 Overview.......................................................................................................................................... 4

1.1 Test Object ...................................................................................................................................... 4


1.1.1 Basis Equipment............................................................................................................................... 4
1.1.2 Digital Communications ECOTEL GSM-GW.................................................................................... 4
1.2 Test Strategy ................................................................................................................................... 5
1.2.1 Test Intensity .................................................................................................................................... 5
1.3 Realisation Data.............................................................................................................................. 6

1.4 Test Results Summary................................................................................................................... 6


1.4.1 Restrictions ....................................................................................................................................... 6
1.4.2 Problems........................................................................................................................................... 6
1.4.3 Remarks ........................................................................................................................................... 6

2 Configuration .................................................................................................................................. 7

2.1 ECOTEL GSM3-3x........................................................................................................................... 7


2.1.1 Configuration Advices....................................................................................................................... 7
2.2 HiPath 4000 ..................................................................................................................................... 7

2.3 Configuration Block Diagram........................................................................................................ 8

3 Test Results in Detail ..................................................................................................................... 9

3.1 Reliability......................................................................................................................................... 9
3.1.1 HiPath 4000 ...................................................................................................................................... 9
3.1.1.1 HiPath Modules ................................................................................................................................ 9
3.1.1.2 Restarts ............................................................................................................................................ 9
3.1.2 ECOTEL ........................................................................................................................................... 9
3.2 Test within Call Processing......................................................................................................... 10
3.2.1 Connection to a/b 2405 & 2406 FXO Port ..................................................................................... 10
3.2.2 Connection to a/b Trunk FXS port .................................................................................................. 10
3.3 Remarks......................................................................................................................................... 11

4 Configuration Data ....................................................................................................................... 12

4.1 HiPath 4000 ................................................................................................................................... 12

5 Confirmation ................................................................................................................................. 23

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 2 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

History of Change

Date Description Name

2008-03-31 Initial Creation Josef Glasl


PSE ECT AES2

2009-01-28 Review and Update Peter Bergmann


SEN ESM GSI TSC GS 2
E-mail: peter.bergmann@siemens.com
phone: +49 (69) 797-9044
Frank Meisenzahl
2009-02-09 Certification Test,
SEN ESM GSI TSC GS 1
update test results
E-mail: frank.meisenzahl@siemens.com
phone: +49 (69) 797-86234
Bernhard Emmert
VIERLING Communications GmbH
E-mail: bernhard.emmert@vierling.de
phone: +49 9194-97243
Frank Meisenzahl
2009-mm-dd Review Final document
SEN ESM GSI TSC GS 1
Signing test results
E-mail: frank.meisenzahl@siemens.com
phone: +49 (69) 797-86234
Bernhard Emmert
VIERLING Communications GmbH
E-mail: bernhard.emmert@vierling.de
phone: +49 9194-97243
Burkhard Speitkamp
2009-mm-dd Review, HiPath 4000 development
SEN ESY
E-mail: burkhard.speitkamp@siemens.com
phone: +49 (89) 722-33791
Peter Bergmann
2009-mm-dd Release
SEN ESM GSI TSC GS 2
E-mail: peter.bergmann@siemens.com
phone: +49 (69) 797-9044

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 3 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

1 Overview

1.1 Test Object

1.1.1 Basis Equipment

Test system: HiPath 4000

Software Version: HiPath 4000 V4.0 R2.1.59

1.1.2 Digital Communications ECOTEL GSM-GW

Certification: Test of interface functionality


- against failures and
- of the features
of the
Test Equipment: ECOTEL GSM3-3x
Software Release: V1.1.14

HW / FW Release: ---

Manufacturer: Address:
VIERLING Communications GmbH
Pretzfelder Straße 21
D-91320 Ebermannstadt
Description: ECOTEL is a GSM Gateway connected to HiPath 4000 via a/b-ports (FXO).
ECOTEL can be used in FXS-mode via TMBD-Trunk.
Documentation:

Test Network:

Test See chapter 2


Configuration:

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 4 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

1.2 Test Strategy


The main goal of this testing is to test
• the external interfaces
• the system failure/recovery behaviour
• the main functionality
of this component within the system as a whole.

The external interfaces are:


• a/b trunk ports on TMBD-Board / Q2025-X300
• a/b ports on SLMA24-Board / Q2246-X

1.2.1 Test Intensity


Scopes of the test are:

- Verification of the correct interworking of ECOTEL GSM Gateway with HiPath 4000.
- Restart behaviour

Note:
The testing of the product with regard to compliance to requirements for Product Safety, EMV, Network
Access Interfaces and Radiation Protection were not performed.
Siemens Enterprise Communications GmbH & Co. KG therefore assumes no responsibility for the
compliance to these requirements.

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 5 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

1.3 Realisation Data

Test Preparation: 2009-02-09

Test Duration: 2009-02-10 – 2009-02-11

Test Location: HiPath Ready Lab Frankfurt


Lyoner Straße 27
D-60528 Frankfurt
Test Personnel: Frank Meisenzahl
SEN ESM GSI TSC GS 1
E-mail: frank.meisenzahl@siemens.com
phone: +49 (69) 797-86234
Bernhard Emmert
VIERLING Communications GmbH
E-mail: bernhard.emmert@vierling.de
phone: +49 (9194) 97243

1.4 Test Results Summary

ECOTEL GSM3-3x V1.1.14 is ready for link to HiPath 4000 V4.

1.4.1 Restrictions

None

1.4.2 Problems
Sporadically, calls to the HiPath 4000 incoming via GSM gateway (FXO mode)
1)
have issues with DTMF signalization.
When calling an inexistent H4K number using DTMF suffix dialling (FXO mode)
2)
the connection isn’t released (may result in significant costs)
Parameter “SOTL” in AMO SCSU (German version) may not be set for users
with analog connection as the Rückauslösung (backward release) will not work in
3) this case.
The HiPath RG module has to be set to 25 Hz and 65 V or the ringing signal will
not be high enough for HKS. This set-up also works for FXO.

1.4.3 Remarks

None

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 6 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

2 Configuration

2.1 ECOTEL GSM3-3x

2.1.1 Configuration Advices


Configuration of ECOTEL was done by VIERLING Communications GmbH staff.
VIERLING Communications GmbH staff attended the certification test.

2.2 HiPath 4000


HW-Version: HiPath 4500 ECX

SW-Version: HiPath 4000 V4 R2.1.59

a/b-ports SLMA24 Q2246-X (Ext. 2405 und 2406)


a/b-Trunk TMBD Q2025-X300

Phones
Up0e-phones: optiPoint 500 standard (Ext. 2410)
optiPoint 500 basic (Ext. 2411 & 2413)
optiSet advance conference (Ext. 2412)
Analogue phones Set 351 T2 (Ext. 2497)
IP phone OpenStage 60G (Ext. 2483)
CMI phones Gigaset S1 Professional (Ext. 2465)

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 7 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

2.3 Configuration Block Diagram

ECOTEL GSM 3-3x connected to a/b – Port (FXO-Mode)

GSM-Netz

SLMA a/b Port

ECOTEL GSM 3-3x connected to a/b – Trunk (FXS-Mode)

GSM-Netz

TMBD a/b Port

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 8 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

3 Test Results in Detail

3.1 Reliability
After regaining normal processing state the functionality of ECOTEL was checked. Disturbance has to be
detected by ECOTEL and the whole system has to come to normal processing state without manual
interference.

3.1.1 HiPath 4000

3.1.1.1 HiPath Modules


No Test Procedure Expected Result a/b-Trunk / -Subscriber
Pull the connection cable between The whole system returns to
ECOTEL and the HiPath port and normal operating mode without
1. OK / OK
put it back again manual interferences.

Pull HiPath modules and put it back The whole system returns to
again normal operating mode without
2. OK / OK
manual interferences

3.1.1.2 Restarts
No Test Procedure Expected Result a/b-Trunk / -Subscriber
Soft Restart of HiPath4000 The whole system comes back
to work without manual
3. OK
interferences.

Hard Restart of HiPath4000 The whole system comes back


to work without manual
4. OK
interferences.

Reload of HiPath4000 The whole system comes back


to work without manual
5. OK
interferences.

Power off/on of HiPath4000 The whole system comes back


to work without manual
6. NP
interferences.

3.1.2 ECOTEL
No Test Procedure Expected Result a/b-Trunk / -Subscriber
Power off / on ECOTEL ECOTEL comes back to work
7. OK
without manual interferences.
Restart of ECOTEL ECOTEL comes back to work
8. OK
without manual interferences.

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 9 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

3.2 Test within Call Processing


This test part checks the correct operation of ECOTEL connected to the HiPath 4000 System. For that
different call scenarios are executed.

3.2.1 Connection to a/b 2405 & 2406 FXO Port


No Test Procedure Result HP4K
9. Up0E phone outgoing call OK
10. DECT phone outgoing call OK
11. IP phone outgoing call (HFA-phone) OK
12. Analogue phone outgoing call OK
13. ISDN phone outgoing call NS
14. 3 party conference (1 int, 2 ext.) OK
15. DTMF detection OK | Problems 2)
16. Incoming call to all types of extension phones OK
17. Toggle OK
18. External line on hold, MOH OK
19. External subscriber makes an enquiry NP
20. External subscriber toggles NP
21. External subscriber transfers the call NP
2 GSM modules of Ecotel GSM GW used
22. NP
simultaneously.
23. Incoming call without DDI OK
24. Incoming call with wrong DDI OK | Problems 3)
25. Incoming call with incomplete DDI OK
26. Incoming call to busy extension OK
27. Incoming call camp on OK
28. Incoming call to hunting group OK
29. Release timeout without DTMF-suffix dialling OK

3.2.2 Connection to a/b Trunk FXS port


No Test Procedure Result HP4K
30. Up0E phone outgoing call OK
31. Analogue phone outgoing call OK
32. IP phone outgoing call (HFA-phone) OK
33. 3 party conference (1 int., 2 ext.) OK
34. DTMF detection OK | Problems 2)
35. Incoming call OK
36. Toggle OK
37. External Call to busy extension OK
38. External subscriber makes an enquiry NP
39. External subscriber toggles NP
40. External subscriber transfers the call NP
41. External line on hold, MOH OK
42. Incoming call without DDI NP
43. Incoming call with wrong DDI NP
44. Incoming call with incomplete DDI NP
45. Incoming call to busy extension OK
46. Incoming call camp on NP
47. Incoming call to hunting group NP
48. Release timeout without DTMF-suffix dialling NP

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 10 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

3.3 Remarks

Meanings of Abbreviations:
OK Test passed
NOK Test failed
NA Test not applicable
NP Test not processed
NS Situation not supplied
NOK *X Error / restriction with description
*X Remark to Functionality

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 11 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

4 Configuration Data

4.1 HiPath 4000


FXO-Konfiguration in der Hipath 4000
<ab-scsu:2405;
AB-SCSU:2405;
H500: AMO SCSU GESTARTET

------------------------- ENDGERAETE-DATEN ----------------------------------


TLNNU =2405 COS1 =15 WABE =0 RNGI =0
LAGE = 1- 1- 91- 0 COS2 =15 VBZ =0 RNGZ1 =
GERKON =ANATE LCOSS1 =7 BUM =0 RNGZ2 =
INBETR =JA LCOSS2 =1 RRSB =NEIN
PMIDX =0 ALARMNR =0 LCOSD1 =7 WMUSIK =0 RRSF =NEIN
GETLNNU =NEIN AMTFANG =NEIN LCOSD2 =1 SOND = NAWA
COFIDX =0 WAHL =VAR PULSTYP = PULSPGL=
CIRCIDX = QUITT = TEXTSEL=
DHPAR =MFVTLN NEONMWI=
ANSCHL =DIR FLASH =JA MFVBLK =NEIN ZZU :NEIN
------------------------- AKTIVIERUNGSKENNZEICHEN FUER LM -------------------
ANRS :NEIN FRZA :NEIN
FRSAS :NEIN FRSAF :NEIN FRSAD :NEIN ANSS :NEIN
------------------------- LM UND GRUPPENZUGEHOERIGKEITEN --------------------
AUN : SAMMELANSCHLUSS : JA DIENST(E): SPR
NACHTVARIANTE : NEIN
------------------------- TEILNEHMER MERKMALE (AMO SDAT) --------------------
KEINE
-----------------------------------------------------------------------------

AMO-SCSU -111 TEILNEHMERDATEN VERWALTEN


ABFRAGEN DURCHGEFUEHRT;

<ab-scsu:2406;
AB-SCSU:2406;
H500: AMO SCSU GESTARTET

------------------------- ENDGERAETE-DATEN ----------------------------------


TLNNU =2406 COS1 =15 WABE =0 RNGI =0
LAGE = 1- 1- 91- 1 COS2 =15 VBZ =0 RNGZ1 =
GERKON =ANATE LCOSS1 =7 BUM =0 RNGZ2 =
INBETR =JA LCOSS2 =1 RRSB =NEIN
PMIDX =0 ALARMNR =0 LCOSD1 =7 WMUSIK =0 RRSF =NEIN
GETLNNU =NEIN AMTFANG =NEIN LCOSD2 =1 SOND = NAWA
COFIDX =0 WAHL =VAR PULSTYP = PULSPGL=
CIRCIDX = QUITT = TEXTSEL=
DHPAR =MFVTLN NEONMWI=
ANSCHL =DIR FLASH =JA MFVBLK =NEIN ZZU :NEIN
------------------------- AKTIVIERUNGSKENNZEICHEN FUER LM -------------------
ANRS :NEIN FRZA :NEIN
FRSAS :NEIN FRSAF :NEIN FRSAD :NEIN ANSS :NEIN
------------------------- LM UND GRUPPENZUGEHOERIGKEITEN --------------------
AUN : SAMMELANSCHLUSS : JA DIENST(E): SPR
NACHTVARIANTE : JA
------------------------- TEILNEHMER MERKMALE (AMO SDAT) --------------------
KEINE
-----------------------------------------------------------------------------

AMO-SCSU -111 TEILNEHMERDATEN VERWALTEN


ABFRAGEN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 12 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<ab-sa:2405;
AB-SA:2405;
H500: AMO SA GESTARTET
+------------------------------------------------------------------------------+
| SAMMELANSCHLUESSE FUER ALLE WABE DIENST = SPR |
+------------+-----------------+---+-------------------------------------------+
| RNR |NAME UND |ART| |
| |VERKEHRSSITUATION| | | |
| | |L|Z| |
| | 1 111 2|I|Y| |
| |12345 67890 123 2|N|K| |
+------------+-----------------+---+-------------------------------------------+
|2405 |.**** ***** **. *| |*| TLNNU: |
| | | | | 2405 |
| | | | | 2406 |
| | | | | VBZ: 0 |
| | | | | ANOKAP: 0 RWS: JA VARAO: NEIN |
| | | | | KSANS: NEIN VERLNEXT: JA |
| | | | | AUSFAUL: NEIN UEBLSCHL: NEIN |
| | | | | ABMLDLZT: NEIN |
| | | | | UEBERLAUF: - |
+------------+-----------------+-+-+-------------------------------------------+

AMO-SA -111 SAMMELANSCHLUSS


ABFRAGEN DURCHGEFUEHRT;
<reg-scsu:2405&2406;
REG-SCSU:2405&2406;
H500: AMO SCSU GESTARTET
EINR-SCSU:2405,1-1-91-0,ANATE,0,0,
15,15,7,1,7,1,,,0,0,0,,NAWA,VAR,
MFVTLN,,,,
JA,,NEIN,,,,0,DIR,JA,NEIN,0,;
EINR-SCSU:2406,1-1-91-1,ANATE,0,0,
15,15,7,1,7,1,,,0,0,0,,NAWA,VAR,
MFVTLN,,,,
JA,,NEIN,,,,0,DIR,JA,NEIN,0,;

AMO-SCSU -111 TEILNEHMERDATEN VERWALTEN


REGENERIEREN DURCHGEFUEHRT;
<reg-sa
RNR = 2405;
REG-SA:2405;
H500: AMO SA GESTARTET
EINRICHTEN-SA:SPR,2405,,,0,
2406

,ZYK,0," ",,,
,,,,,;

AMO-SA -111 SAMMELANSCHLUSS


REGENERIEREN DURCHGEFUEHRT;
<

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 13 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

FXS-Konfiguration in der Hipath 4000


<ab-bcsu:tab,1,1;
AB-BCSU:TAB,1,1;
H500: AMO BCSU GESTARTET

ADRESSE : LTG 1 LTU 1 SOURCE GROUP 1 ALARMNR-LTU 0


-----+-----------+--------+---+-+-+---+-+------------+------------+------------
| | | |S|H|AL-| | | |
| SOLL | BG |FCT|E|W|ARM| | IST | HW- | BG
EBT | BG | TYP |ID |C|Y|NR | | BG |STAND INFO | ZUSTAND
-----+-----------+--------+---+-+-+---+-+------------+------------+------------
19 | Q2258-X RG 0| | Q2258-X | 1 - | READY
25 | Q2096-X200 DIU-S2 A 0| | Q2096-X200 | 1 D762-C | READY
31 | FREI 0| | FREI | |
37 | Q2316-X10 STMI2 1 * A 0| | Q2316-X10 | 1 -05 - | READY
+--------------------------------+-+------------+------------+------------
| IP ADRESSE : 192.168. 40. 70 B-KANAELE : 120 ANZBKAN : 90
| BLOCK-NR : 2 RESERV. LINES UMGEWANDELT : NEIN
| 1. FUNKT : HG3570 1 LINES B-KANAELE : 120 ANZBKAN : 90
| SECURITY STATUS: 1:[ ] 2:[ ] 3:[ ] 4:[ ] 5:[ ] 6:[ ] 7:[ ] 8:[ ]
| (SIEHE ENDE) 9:[ ] 10:[ ] 11:[ ] 12:[ ] 13:[ ] 14:[ ] 15:[ ] 16:[ ]
+--------------------------------+-+------------+------------+------------
43 | FREI 0| | FREI | |
49 | Q2193-X200 SLC24 A 0| | Q2193-X200 | 1 -F4 - | READY
55 | FREI 0| | FREI | |
61 | Q2025-X300 TMBD A 0| | Q2025-X300 | 1 B008-D | READY
67 | FREI 0| | FREI | |
73 | Q2248-X LTUCE 0| | Q2248-X | 1 -03 - | READY
79 | Q2096-X200 DIU-S2 A 0| | Q2096-X200 | 1 D762-C | READY
85 | Q2096-X200 DIU-S2 A 0| | Q2096-X200 | 1 D762-C | READY
91 | Q2246-X SLMA24 A 0| | Q2246-X | 1 -07 - | READY
97 | Q2316-X10 STMI2 1 A 0| | Q2316-X10 | 1 -05 - | READY
+--------------------------------+-+------------+------------+------------
| IP ADRESSE : 192.168. 40. 50 B-KANAELE : 120 ANZBKAN : 97
| BLOCK-NR : 6 RESERV. LINES UMGEWANDELT : NEIN
| 1. FUNKT : HG3550 3 LINES B-KANAELE : 90 ANZBKAN : 67
| 2. FUNKT : WAML 1 LINES B-KANAELE : 30 ANZBKAN : 30
| SECURITY STATUS: 1:[ ] 2:[ ] 3:[ ] 4:[ ] 5:[ ] 6:[ ] 7:[ ] 8:[ ]
| (SIEHE ENDE) 9:[ ] 10:[ ] 11:[ ] 12:[ ] 13:[ ] 14:[ ] 15:[ ] 16:[ ]
+--------------------------------+-+------------+------------+------------
103 | Q2324-X510 STMI4 1 A 0| | Q2324-X510 | 1 -07 - | READY
+--------------------------------+-+------------+------------+------------
| IP ADRESSE : 192.168. 40. 30 B-KANAELE : 60 ANZBKAN : 60
| BLOCK-NR : 7 RESERV. LINES UMGEWANDELT : NEIN
| 1. FUNKT : HG3530 120 LINES B-KANAELE : 60 ANZBKAN : 60
| SECURITY STATUS: 1:[ ] 2:[ ] 3:[ ] 4:[ ] 5:[ ] 6:[ ] 7:[ ] 8:[ ]
| (SIEHE ENDE) 9:[ ] 10:[ ] 11:[ ] 12:[ ] 13:[ ] 14:[ ] 15:[ ] 16:[ ]
+--------------------------------+-+------------+------------+------------
109 | FREI 0| | FREI | |
115 | FREI 0| | FREI | |
121 | Q2205-X WAML 1 A 0| | Q2205-X | 1 -09 - | READY

+----+----+---------------------------+-+------------+------------+--------+
| KEIN SECURITY STATUS VERFUEGBAR, DA DAS FEATURE SPE NICHT AKTIVIERT IST |
+---------+----------------------------------------------------------------+
AMO-BCSU -111 KONFIGURIEREN DER LTU-BAUGRUPPEN
ABFRAGEN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 14 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<ab-buend:99;
AB-BUEND:99;
H500: AMO BUEND GESTARTET

+------------------------------- FORMAT = L -----------------------------------+


| BUENDELNUMMER : 99 BUENDELNAME: TEST-VIERLING MAX-ANZAHL: 4 |
| ZEICHUM : NEUTRAL |
| UNTERGR.NUMMER: 53 GERAETETYP : HKZ ANZFANG : 0 |
| SUCHART : ZYKLISCH ANZACD : * |
| ANZAHL DER ZUGEORDNETEN RICHTUNGEN : 1 PRIORITAET: 1 |
| TDDRFLAG : ON TDDRTHRESHOLD: 0 SOURCEGROUPIDX : 1 |
| GDTRRGL : 0 ACDPMGRP : 0 |
| FOLGENDE SATZLAGEN (LTG-LTU-EBT-SATZNUMMER) SIND ZUGEORDNET: |
+------------------------------------------------------------------------------+
| 1- 1- 61-0 | 1- 1- 61-3 | | | |
+------------------------------------------------------------------------------+

AMO-BUEND-111 BUENDEL
ABFRAGEN DURCHGEFUEHRT;
<ab-tacsu;
AB-TACSU;
H500: AMO TACSU GESTARTET
ANALOGE SAETZE (FORMAT=L)
LAGE | 1-1-61-0 | 1-1-61-3 |
--------|--------------------------------|--------------------------------|
GERTYP | AS1 | AS1 |
GER | HKZ | HKZ |
COTNR | 99 | 99 |
COPNR | 99 | 99 |
WABE | 0 | 0 |
VBZ | 0 | 0 |
BUNR | 99 | 99 |
COFIDX | 0 | 0 |
SATZNR | | |
ZLNR | 99 | 99 |
INBETR | J | J |
COS | 99 | 99 |
LCOSS | 7 | 7 |
LCOSD | 7 | 7 |
ENACHT | | |
KNNR | 1-1-499 | 1-1-499 |
ALARMNR | 0 | 0 |
CARRIER | 1 | 1 |
ZONE | LEER | LEER |
LIN | 0 | 0 |
CIDDGTS | KEINE | KEINE |
CBMATTR | KEINE | KEINE |
SRCGRP | 0 | 0 |
CLASSMRK| EC G711 G729AOPT | EC G711 G729AOPT |
TCCID | | |
DITIDX | 0 | 0 |
TRTBL | GDTR | GDTR |
RULEIDX | 0 | 0 |
ATNTYP | | |
GEB | 1 | 1 |
ZIVO | 2497 | 2497 |
---------------------------------------------------------------------------

AMO-TACSU-111 ANALOGE LEITUNGSSAETZE KONFIGURIEREN


ABFRAGEN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 15 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<ab-cossu:cos,99;
AB-COSSU:COS,99;
H500: AMO COSSU GESTARTET
+------+-----------------+---------------+-----------------+
| COS | SPRACHE | FAX | DEE |
+------+-----------------+---------------+-----------------+
| 99 |> |
| | FBKW | FBKW | FBKW |
| | QVKW | QVKW | QVKW |
| | GESP | GRUBE | GRUBE |
| | AULEXT | UENW | UENW |
| | UENW | | |
| | AULERU | | |
+------+-----------------+---------------+-----------------+

AMO-COSSU-111 BERECHTIGUNGSKLASSEN
ABFRAGEN DURCHGEFUEHRT;

<ab-cot:99;
AB-COT:99;
H500: AMO COT GESTARTET

COT: 99 INFO:
GERAET: UNAB QUELLE: DB
PARAMETER:
UMLEITEN AMTSGESPRAECH UASE
LEITUNG MIT MELDEKRITERIUM MVLT
UEBERGABE IM BESETZT-, RUF- ODER GESPRAECHSZUSTAND UELM
KOMMENDE LEITUNG VON ANLAGE OHNE LCR OLCR
VOREINGESTELLE KNOTENNUMMER DER LEITUNG VERWENDEN VKNN
KOMMENDE LEITUNG VON ANLAGE OHNE LCR (DATEN) OLRD
HKZ LEITUNG MIT AUSLOESEUEBERWACHUNG HKZA
KEIN TON KTON

AMO-COT -111 CLASS OF TRUNK


ABFRAGEN DURCHGEFUEHRT;

<ab-cop:99;
AB-COP:99;
H500: AMO COP GESTARTET

COP: 99 INFO:
GERAET: UNAB QUELLE: DB
PARAMETER:
LEITUNG MIT MFV-WAHL MFVW
LEITUNG MIT LEITUNGSUEBERWACHUNG BZW. AUSLOESEQUITTUNG LUEW
KOMMENDE BELEGUNG HKZ FUEHRT ZU FEST EINGERICHTETEM TLN DITR
ZWISCHENWAHLZEIT 1 ZWZ1
IMPULS-PAUSE-VERHAELTNIS MFV VAR=3 (PULS=200MS/PAUSE=200MS) MFV3

AMTSBERECHTIGUNG:
FERNBERECHTIGUNG FBKW

FERNBERECHTIGUNG:
FERNBERECHTIGUNG FBKW

AMO-COP -111 CLASS OF PARAMETER


ABFRAGEN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 16 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<ab-richt:lrtg,99;
AB-RICHT:LRTG,99;
H500: AMO RICHT GESTARTET
+-----------------------------------------------------------------+
| LRTG = 99 NAME = TEST-VIERLING (NEUTRAL) LDIENST = SPR |
| ZKNNR=1 -1 -99 PZKNNR= 0 ZLNR = 99 |
| ROUTOPT = NEIN REROUT = JA VLVER = JA UMLVER = NEIN |
| MFVUMS = FIX MFVANZ = ZIFFERN MFVTEXT = MFV-WAHL |
| MFVPULS = PP300 BUGS = LIN ROUTATT = NEIN MAINGRP = 71 |
| EMCYRTT = NEIN CONFTON = NEIN RERINGRP = NEIN RTGNR = 72 |
| INFO = |
| KPRCAUL = NEIN |
| KATG = NEIN |
| CLNAMEDL = NEIN |
| FWDSWTCH = NEIN |
| LINFNOT = NEIN |
+-----------------------------------------------------------------+
| BUNUM = 99 LDAT TEST-VIERLING (NEUTRAL) SUBGROUP = 53 |
+-----------------------------------------------------------------+

AMO-RICHT-111 RICHTUNG
ABFRAGEN DURCHGEFUEHRT;
<ab-ldat:lcr,99;
AB-LDAT:LCR,99;
H500: AMO LDAT GESTARTET
+------------------------------------------------------------------------------+
| LRTG = 99 LDPLN NAME = TEST-VIERLING DIENST = SPR |
| TYP = LCR ZKNNR-RICHTUNG = 1 -1 -99 |
| SERVICE INFO = |
+------+-----+-----+----+-----+----------+-----------+----------+------+-------+
| | | | | | ZEITBAND | CARRIER | | | |
|LRTGEL|LWERT|BUNUM| LWR|LBER | ABCDEFGH | ZONE| LATTR | LDSRT|COTIDX |
+------+-----+-----+----+-----+----------+-----------+----------+------+-------+
| 1| 1| 99| 99| 1 | ******** | 1 LEER| KEINE | | 0 |
+------------------------------------------------------------------------------+

AMO-LDAT -111 LCR-RICHTUNGEN


ABFRAGEN DURCHGEFUEHRT;

<ab-lodr:99;
AB-LODR:99;
H500: AMO LODR GESTARTET
+-------------------------------------------------------+
| LWR LWRELPOS LWREL PARAMETER |
+--------+----------------------------------------------+
| 99 | 1 ECHOFELD 2 |
| | 2 ENDE |
+--------+----------------------------------------------+
H03: DIE NAECHSTE FREIE LWR IST 4

AMO-LODR -111 ADMINISTRATION VON LCR-WAHLREGELN


ABFRAGEN DURCHGEFUEHRT;

<ab-ldpln:rnr,998;
AB-LDPLN:RNR,998;
H500: AMO LDPLN GESTARTET

AMO-LDPLN-111 EINRICHTEN WAEHLMUSTERPLAN FUER LCR


ABFRAGEN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 17 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<ab-ldpln:rnr,988;
AB-LDPLN:RNR,988;
H500: AMO LDPLN GESTARTET
+----------------------------------------------------------+
| RNR 988 ---> |
+-------+-------------------------------------+------------+
| LWMNR | LWM | WAPLNUM |
+-------+-------------------------------------+------------+
| 76 | 988-X | 0 |
+-------+--------------------------------------------------+

AMO-LDPLN-111 EINRICHTEN WAEHLMUSTERPLAN FUER LCR


ABFRAGEN DURCHGEFUEHRT;

<ab-wabe:allg,988;
AB-WABE:ALLG,988;
H500: AMO WABE GESTARTET
------------------------------------------------------------------------------
| WAHLBEWERTUNG GUELTIG FUER ALLE WABE-GRUPPEN |
------------------------------------------------------------------------------
| | VERKEHRSSITUATION | KNOTEN/ | VORLEIST/RUFUM |
| RUFNUMMER | 1 11111 11112 22| KENNZAHL | DNI/ZUSATZINFO |
| |0 12345 67890 12345 67890 12| PUNKT | *=EIGENER KNOTEN |
------------------------------------------------------------------------------
| 988 |. .**** ***** **... ..... .*| QUER | |
------------------------------------------------------------------------------

AMO-WABE -111 WAHLBEWERTUNG


ABFRAGEN DURCHGEFUEHRT;

<ab-sa:2410;
AB-SA:2410;
H500: AMO SA GESTARTET
+------------------------------------------------------------------------------+
| SAMMELANSCHLUESSE FUER ALLE WABE DIENST = SPR |
+------------+-----------------+---+-------------------------------------------+
| RNR |NAME UND |ART| |
| |VERKEHRSSITUATION| | | |
| | |L|Z| |
| | 1 111 2|I|Y| |
| |12345 67890 123 2|N|K| |
+------------+-----------------+---+-------------------------------------------+
|2410 |.**** ***** **. *| |*| TLNNU: |
| | | | | 2410 |
| | | | | 2411 |
| | | | | 2412 |
| | | | | 2413 |
| | | | | VBZ: 0 |
| | | | | ANOKAP: 5 RWS: JA VARAO: NEIN |
| | | | | KSANS: NEIN VERLNEXT: JA |
| | | | | AUSFAUL: NEIN UEBLSCHL: NEIN |
| | | | | ABMLDLZT: NEIN |
| | | | | UEBERLAUF: - |
+------------+-----------------+-+-+-------------------------------------------+

AMO-SA -111 SAMMELANSCHLUSS


ABFRAGEN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 18 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<ab-aun:tln,2410;
AB-AUN:TLN,2410;
H500: AMO AUN GESTARTET
+---------------------------------------------------------------------------+
| GRUPPENNUMMER: 3 TEAMNUMMER: |
| NW-RESERVIERT: NEIN |
| |
| ANZEIGE A-NR: NEIN AUFMERKSAMKEITSRUF: MIT3 |
| AUN ZWEITANRUF: NEIN SIGNALISIERUNGSMODUS: ALLE |
| |
| TEILNEHMER: 2410 |
| 2413 |
+---------------------------------------------------------------------------+

AMO-AUN -111 ANRUFUEBERNAHME


ABFRAGEN DURCHGEFUEHRT;

<ab-scsu:2497;
AB-SCSU:2497;
H500: AMO SCSU GESTARTET

------------------------- ENDGERAETE-DATEN ----------------------------------


TLNNU =2497 COS1 =12 WABE =0 RNGI =0
LAGE = 1- 1- 91- 3 COS2 =12 VBZ =0 RNGZ1 =
GERKON =ANATE LCOSS1 =32 BUM =0 RNGZ2 =
INBETR =JA LCOSS2 =32 RRSB =NEIN
PMIDX =0 ALARMNR =0 LCOSD1 =32 WMUSIK =0 RRSF =NEIN
GETLNNU =NEIN AMTFANG =NEIN LCOSD2 =32 SOND =
COFIDX =0 WAHL =VAR PULSTYP = PULSPGL=
CIRCIDX = QUITT = TEXTSEL=
DHPAR = NEONMWI=
ANSCHL =DIR FLASH =JA MFVBLK =NEIN ZZU :NEIN
------------------------- AKTIVIERUNGSKENNZEICHEN FUER LM -------------------
ANRS :NEIN FRZA :NEIN
FRSAS :NEIN FRSAF :NEIN FRSAD :NEIN ANSS :NEIN
------------------------- LM UND GRUPPENZUGEHOERIGKEITEN --------------------
AUN : SAMMELANSCHLUSS : NEIN
NACHTVARIANTE : JA
------------------------- TEILNEHMER MERKMALE (AMO SDAT) --------------------
KEINE
-----------------------------------------------------------------------------
DIESER TEILNEHMER IST IN DER NACHTVARIANTE 3 VORHANDEN.

AMO-SCSU -111 TEILNEHMERDATEN VERWALTEN


ABFRAGEN DURCHGEFUEHRT;
<

<reg-buend:99;
REG-BUEND:99;
H500: AMO BUEND GESTARTET
EINR-BUEND:99 ,"TEST-VIERLING ",4 ,0 ,* ,1 ,ON ,0 ,0 ,NEUTRAL;

AMO-BUEND-111 BUENDEL
REGENERIEREN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 19 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<reg-tacsu;
REG-TACSU;
H500: AMO TACSU GESTARTET
EINRICHTEN-TACSU: 1-1-61-0, , 99, 99, 0, 0, 99, 7, 7,
, 99, 0," ",
99, 1-1-499, 0,1,LEER ,0 ,
KEINE, KEINE, 0,EC &G711&G729AOPT,
" ", 0, GDTR,
0, ,J ,AS1 ,HKZ ,
1, 2497;
EINRICHTEN-TACSU: 1-1-61-3, , 99, 99, 0, 0, 99, 7, 7,
, 99, 0," ",
99, 1-1-499, 0,1,LEER ,0 ,
KEINE, KEINE, 0,EC &G711&G729AOPT,
" ", 0, GDTR,
0, ,J ,AS1 ,HKZ ,
1, 2497;

AMO-TACSU-111 ANALOGE LEITUNGSSAETZE KONFIGURIEREN


REGENERIEREN DURCHGEFUEHRT;

<reg-cossu:cos,99;
REG-COSSU:COS,99;
H500: AMO COSSU GESTARTET
EINR-COSSU:,99,,,,,,,,"";
AEND-COSSU:COS,99,FBKW&QVKW&GESP&AULEXT&UENW&AULERU;
AEND-COSSU:COS,99,,FBKW&QVKW&GRUBE&UENW;
AEND-COSSU:COS,99,,,FBKW&QVKW&GRUBE&UENW;

AMO-COSSU-111 BERECHTIGUNGSKLASSEN
REGENERIEREN DURCHGEFUEHRT;

<reg-cot:99;
REG-COT:99;
H500: AMO COT GESTARTET
EINRICHTEN-COT:99,UASE&MVLT&UELM&OLCR&VKNN&OLRD&HKZA&KTON;

AMO-COT -111 CLASS OF TRUNK


REGENERIEREN DURCHGEFUEHRT;

<reg-cop:99;
REG-COP:99;
H500: AMO COP GESTARTET
EINRICHTEN-COP:99,MFVW&LUEW&DITR&ZWZ1&MFV3,FBKW,FBKW;

AMO-COP -111 CLASS OF PARAMETER


REGENERIEREN DURCHGEFUEHRT;

<reg-richt:lrtg,99;
REG-RICHT:LRTG,99;
H500: AMO RICHT GESTARTET
EINR-RICHT:LRTGNEU,99,SPR,"TEST-VIERLING ",
99,1-1-99,,,
FIX,ZIFFERN,"MFV-WAHL ",PP300,,,99,,NEIN,
NEIN,"",0,
NEUTRAL,NEIN,NEIN,NEIN,NEIN,NEIN,NEIN,NEIN ;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 20 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

AMO-RICHT-111 RICHTUNG
REGENERIEREN DURCHGEFUEHRT;

<reg-ldat:99;
REG-LDAT:99;
H500: AMO LDAT GESTARTET
EINRICHTEN-LDAT:99,SPR,1,,99,99,1,,1,LEER,KEINE,,4,,,,,,,,,,,,;

AMO-LDAT -111 LCR-RICHTUNGEN


REGENERIEREN DURCHGEFUEHRT;

<reg-lodr:99;
REG-LODR:99;
H500: AMO LODR GESTARTET
EINRICHTEN-LODR:99,,,,ECHOFELD,2;
EINRICHTEN-LODR:99,,,,ENDE;

AMO-LODR -111 ADMINISTRATION VON LCR-WAHLREGELN


REGENERIEREN DURCHGEFUEHRT;

<REGENERIEREN-LDPLN:WAPLNUM=0,LWM="988";
REGENERIEREN-LDPLN:WAPLNUM=0,LWM="988";
H500: AMO LDPLN GESTARTET

AMO-LDPLN-111 EINRICHTEN WAEHLMUSTERPLAN FUER LCR


REGENERIEREN DURCHGEFUEHRT;

<REGENERIEREN-LDPLN:WAPLNUM=0,LWMNR=76;
REGENERIEREN-LDPLN:WAPLNUM=0,LWMNR=76;
H500: AMO LDPLN GESTARTET
EINRICHTEN-LDPLN:LCRMUST,0,988-X,,99,,,1,,,,NEIN;

AMO-LDPLN-111 EINRICHTEN WAEHLMUSTERPLAN FUER LCR


REGENERIEREN DURCHGEFUEHRT;
<REG-WABE:988,;
H500: AMO WABE GESTARTET
EINRICHTEN-WABE: 988,,,QUER,NEIN,,,,,,,,;

AMO-WABE -111 WAHLBEWERTUNG


REGENERIEREN DURCHGEFUEHRT;
<reg-bcsu:1,1;
REG-BCSU:1,1;
H500: AMO BCSU GESTARTET
EINR-BCSU:RG,1,1,19,"Q2258-X ",UN25H65V,0,0; IMPORTANT ! Set RG to 25 Hz!
EINR-BCSU:DIU,1,1,25,"Q2096-X200",0,,,,,0,,,,,A,0;
EINR-BCSU:IPGW,1,1,37,"Q2316-X10 ",1,0,2,192.168.40.70,
,,,,120,0;
EINR-BCSU:PER,1,1,49,"Q2193-X200",0,5,224,,,,,A,0;
EINR-BCSU:PER,1,1,61,"Q2025-X300",0,0,,,,,,A,0;
EINR-BCSU:DIU,1,1,79,"Q2096-X200",0,,,,,0,,,,,A,0;
EINR-BCSU:DIU,1,1,85,"Q2096-X200",0,,,,,0,,,,,A,0;
EINR-BCSU:PER,1,1,91,"Q2246-X ",0,0,,,,,,A,0;
EINR-BCSU:IPGW,1,1,97,"Q2316-X10 ",1,0,6,,
,,90,30,,0;
EINR-BCSU:IPGW,1,1,103,"Q2324-X510",1,0,7,,
60,,,,,0;
EINR-BCSU:PER,1,1,121,"Q2205-X ",1,0,,,,,,A,0;

AMO-BCSU -111 KONFIGURIEREN DER LTU-BAUGRUPPEN


REGENERIEREN DURCHGEFUEHRT;

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 21 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

<reg-sa:2410;
REG-SA:2410;
H500: AMO SA GESTARTET
EINRICHTEN-SA:SPR,2410,,,0,
2411&2412&2413

,ZYK,5," ",,,
,,,,,;

AMO-SA -111 SAMMELANSCHLUSS


REGENERIEREN DURCHGEFUEHRT;

<reg-aun:tln,2410;
REG-AUN:TLN,2410;
H500: AMO AUN GESTARTET
EINR-AUN: 3,,GRU,2410&2413
,,,NEIN,MIT3,NEIN,ALLE,,,,,;

AMO-AUN -111 ANRUFUEBERNAHME


REGENERIEREN DURCHGEFUEHRT;

<reg-scsu:2497;
REG-SCSU:2497;
H500: AMO SCSU GESTARTET
EINR-SCSU:2497,1-1-91-3,ANATE,0,0,
12,12,32,32,32,32,,,0,0,0,,,
,,,,
JA,,NEIN,,,,0,DIR,JA,NEIN,0,;

AMO-SCSU -111 TEILNEHMERDATEN VERWALTEN


REGENERIEREN DURCHGEFUEHRT;
<

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 22 of 23
Siemens VIERLING / ECOTEL GSM3-3x
Enterprise Communications HiPath 4000 V4

5 Confirmation
Testing personnel confirms that the test cases in chapter 3 were performed and that the results were as
described in this document.

Bernhard Emmert Frank Meisenzahl

VIERLING Communications GmbH SEN ESM GSI TSC GS 1

Owner: Peter Bergmann Test Report of Certification


Department: SEN ESM GSI TSC GS 2
Date: 2010-02-15
Document rep_vierling_ecotel_GSM3-3_h4kv40.doc Page 23 of 23