Basic command for 2G BTS1.

For UP/DOWN Status-


RLCRP: CELL=ALL
;( if shows 0 for all value site/sector will be down)2. If site down check the
condition of PCM �if it is ABL (not working) verify theloop test to identify the
fault and if PCM is working check the alarm on BTS.3. For finding the PCM use
command-
RXTCP: MOTY=RXOTG, CELL=cell;
(cell id with sector i.eBST001A)It gives TG VAULE
RXAPP: MO=RXOTG-tg $;
(tg$ is TG VALUE)It gives device no. use last device
RADEP: DEV=dev$;
(dev$ is device value i.eRBLT-2719)It gives SNT value
NTCOP: SNT=snt$;
Find the device no that is used in dev$ and corresponding vaule of DIP4. Check the
status of PCM
DTSTP: DIP=dip$;
(dip$ is DIP VALUE i.e 83RBLT)
DTQDP: DIP=dip$; & DTQUP: DIP=dip$;
(FOR finding error on PCM,Check the value of es, ses uas & SLIP ,these value must
be 0 or constant)5. If PCM condition found working then BLOCK /DEBLOCK to get
managed objectin working condition use command
RXBLI:MO=mo$,subord,force;RXESE:MO=mo$,subord;RXESI:MO=mo$,subord;RXBLE:MO=mo$,subo
rd;
(mo$ - RXOTG-tg$, RXOCF-tg$, RXOCON -tg$ ,RXOIS-tg$,RXOTRX-tg$-teivalue ,RXOTX-tg$-
tei value,RXORX-tg$- tei value,RXOTS-tg$-tei value-timeslot no)Page
1
of
4

6. For finding the faulty managed object use command


RXASP: MO=RXOTG- tg$;
This alarm list contains various alarms like BTS INT UNAFFECTED, BTS INTAFFECTED,
PERMANENT FAULT, some alarms can be removed by usingBLOCK/DEBLOCK commands.7. For
finding fault code on particular managed object (mo) use
RXMFP: MO=mo$;
This command shows fault code class and code some description is bellow
?
IF mo$ is RXOCF then FAULT CODE IS
2A-33 RX diversity lost2A-8 VSWR limits exceeded2A-57 RX PATH IMBLANCE (VSWR)2A-39
RX cable disconnected (Related faults: RXORX 1B:9 - RX cabledisconnected)2A:7 RXDA
amplifier current faults (CDU FAULTY Need replacement
)
2A-21 internal power capacity reduced (PSU unit faulty or power off)2A-41 lost
communication to TRU2A:23 Climate capacities reduced (Check fans and the Fan
Control Unit)2A:9 Power limits exceeded (Related faults: RXOTX 1B:2 TRU faulty
needreplacement)
?
If mo$ is RXOTRX then fault code is
1A-13 TX saturation (TRU FAULTY Need replacement)2A-12 TX output power limits
exceeded (Related faults: TX 1B:13)block/deblock unit if not work Change TRU2A-13
TX saturation (Related faults: TX 1B:14 - TX saturation)block/deblock unit if not
work Change TRU2A:25 TX max power restricted block /deblock unit if not work Change
TRU2A:43 internal configuration fail block /deblock unit if not work Change
TRU2A:42 Hardware IDB inconsistent check combiner chip & then IDBAny alarm found
other than mentioned above on any manage object then pleaseconsult with MSC
Gorakhpur
8. FOR replacement of TRU
First get local mode on TRU by pressing Local /Remote button on TRU2
nd
power off the TRU3
RD
with the help of T10 Screw driver open the 2 pair screw on upper/lowerend of unit4
th
replace the faulty unit with new one5
th
power on and wait until Local Lamp get constant glow6
th
again get remote status by pressing Local /Remote button on TRUPage
2
of
4

Wait for operation condition by 5minute if not operational block/deblock fromBSC if


not work contact with MSC Gorakhpur
Same processors adopt for CDU replacement (except Local/remote)Caution must be
taken for wiring of units
Tools (basic) used for hardware replacement are-32� wrench8/9 wrenchNoze
pliersT10T8
For analysis of TCH BLOCKING
1. Find that site working in full configuration by using commandRXCDP: MO=RXOTG-
tg$; (ALL mo must be configured)
If any BLOCKED found then use command
RXASP: MO=RXOTG-tg$; (to find the all alarm and reason of block)IF LOCAL MODE found
than try to make REMOTE otherwiseCheck the fault code by commandRXMFP:MO=mo$; (to
find the exact fault code to make decision thathardware if faulty or not if
hardware is faulty and need replacement thenbook the fault to ericsson and if the
hardware is not faulty theBLOCK/DEBLOCK to make unit operational )
If any mo not block then check the half rate is on or off
For checking half rate use commandRLDHP: CELL=cell; (DHA=ON)If DHA not ON use
command to on itRLDHC: CELL=cell, DHA=ON;If traffic is more than for witch site is
configured (as erlang B table ) thenincrease the value of half rate by using
commandRLDHC: CELL=cell, DTHAMR=100, DTHNAMR=100;Erlang B tableTRU (Per sector)
Traffic that supported on full rate1 2.2E2 8.0E3 14.5E4 21.4E5 28.5E6 35.8E7 43.1E8
50.5E
If none of the above case so new BTS is required to release congestion