FSM

Section: Rotary
Sheet No:
Date: 4/21/2005 Rev.1
Rotary and Sierra Supersedes:

X-Tend Food Grade Filtration Installation Instructions

1) Install new filter during lubricant change out.

2) Remove existing scavenge line between separator tank and airend.

3) Mount the new X-Tend filter mounting head to a rigid surface using the 3
supplied tap-tite screws.

4) Use hoses and fittings supplied in kit to pipe from separator tank to filter
mounting head “in” and then from filter head “out” to airend.

5) Fill the filter module ¾ full with fresh FG lubricant and install on filter head.

6) Record date on module.

7) Operate for 30 minutes and check for leaks.

8) Change module every 6 months or as determined by the Increase in TAN.

Installation kits Filter module

7.5 –100 HP 38430914 38430898


100-500 HP 38431094 38430906

X-Tend 46 Coolant

5 Liter 38433108
5 Gallon 38433116
55 Gallon 38433124