You are on page 1of 2

Product Information

m Bulletin 04-01 Rev 10/04

Nafion®
perfluorinated membranes

Nafion® NE-2030
DESCRIPTION
Nafion® NE-2030 is the latest development in the High Performance family of membranes offered by DuPont.
Introduced in mid-2004, it uses the same proven polymers as N982 while exhibiting significantly lower
voltage. NE-2030 shares the same reinforcement with N982 and N2010, ensuring safe and reliable operation.
Nafion® NE-2030 is a high performance membrane for narrow and zero gap electrolyzers for the production of
chlorine and 30-35% caustic soda.

NE-2030
• is reinforced for safe operation
• is modified on both the anode and cathode surface to enhance gas release
• is supplied in “WX” and “TX” forms

PERFORMANCE
• Commercial Performance

Membrane Narrow Gap Cell*


Type Cell Voltage Current
(V) Efficiency (%)

NE-2030 2.87 >96

N-982 2.95 >96

* Conditions: Narrow gap, DSA anode, Nickel cathode, 32% NaOH, 200 g/l anolyte, 90 deg. C, 3.0 kA/m2

FORM
Membrane in WX form is pre-expanded and wet in pH 10 solution. WX is an easy to use membrane and
is less prone to damage during handling. Refer to Technical Bulletin 93-03, “Nafion® Membrane WX
Products,” for more information.

Membrane in TX form is pre-expanded, and ready to install directly into chloralkali electrolyzers without
any pretreatment. Refer to Technical Bulletin No. 93-02 for information on TX membranes.

To ensure optimum performance of Nafion® NE-2030 in a commercial electrolyzer, please contact your
representative for Nafion®.

Note: The side marked CATH must be installed facing the cathode; otherwise, the
membrane will be irreversibly damaged in use.
SIZE AND PACKAGING
Nafion® membranes are available in custom sizes with widths up to 1.5 meters and lengths up to 4
meters.

WX membrane
Small sheets are sealed in polyethylene pouches and shipped flat, in wooden containers. Large sheets
are rolled on plastic tubes, wrapped with a polyethylene sheet, and shipped in a water tight plastic
container.

TX membrane
Small sheets are sealed in pouches and shipped flat in wooden containers. Large sheets are rolled on a
polyethylene covered fiberboard tube, wrapped with a polyethylene sheet, and shipped in a plastic
container.

ORDER INFORMATION
The NE designation of Nafion® NE-2030 denotes an experimental product which is subject to change,
may require a secrecy agreement, and for which data feedback may be expected. The size availability of
this product may vary, please contact your local Nafion® representative for details.
____________________________________________________________________________
For more information about Nafion® or to place an order, contact:

DuPont
Nafion® Global Customer Service
22828NC 87 HWY W.
Fayetteville, NC 28306, U.S.A.
Telephone: (910) 678-1380 or (910) 678-1337
Domestic U.S.A. Only: (800) 436-1336 Fax: (910) 678-1342
_________________________________________________________________________________________
Nafion® is a DuPont registered trademark for its brand of perfluorinated polymer products, made and sold only by
E.I. DuPont de Nemours and Company.

The data listed here fall within the normal range of product properties, but they should not be used to establish
specification limits nor used alone as the basis of design. This information is based on technical data DuPont believes to
be reliable. It is intended for use by persons having technical skill, at their own discretion and risk. This information is
given with the understanding that those using it will satisfy themselves that their particular conditions of use present no
health or safety hazards. Because conditions of product use are outside our control, DuPont makes no warranties, express
or implied, and assumes no obligation or liability in connection with any use of this information or for results obtained with
respect to these products. This information is provided gratis, and buyer assumes the sole responsibility for results
obtained in reliance thereon. The disclosure of the information is not a license to operate under or a recommendation to
infringe any patent of DuPont or others.

CAUTION: Do not use in medical applications involving permanent implantation in the human body. For other medical
applications, see “DuPont Medical Caution Statement”, H-50102.