You are on page 1of 1

1 2 3 4

ARKEL ADrive

DOWN
RFO

RPO
RFA

RPA
Controller Board

VO

EN
UP
V1
V3
A A

15
L1 L2 L3 E B P N U V W
KP1 KP2

Contact common

1
EMC Filter Fren KP1 FAST RH
Direnci KF RPY
DOWN RU1
220V 24V DC

2
KP2
B Serisi Trifaze AC3 UP RU2
V-Otomat Sigorta

220ac 24Vdc inspection switch


L1 L2 L3 (optional)
B B
(R) (S) (T)
3-Phase power supply RPY
360V- 420V Motor

1
50/60 Hz
Power Supply of

KP1

KP2
PE 220V 220V contactors must be taken
AC3 AC3 from safety circuit (door locks)

2
Mexhanical Brake Circuit

C
220Vac For a smooth stop , ADrive must continue to drive C

KP1
motor for 1-3 seconds after stop signal is comming
(Ramping to Zero speed).
KP2 So the safety circuit must continue supply KP1 and
KP2 contactors till drive finish. Doors must be
~
~

keep closed till drive end.


+
-

KF
Brake+

Brake-

D D

PROJE : ARKEL ADrive ARKEL


ŞEMA : ARKEL ADrive MOTOR SURUCUSUNUN KUMANDA KARTLARI ILE BAGLANTILARI Elektrik Elektronik Tic. Ltd. Şti.
Dosya Adı : ADRIVE & CONTROLLER CONNECTION PRINCIPLE.SCHDOC Tarih : 7/29/2008 www.arkel.com.tr