You are on page 1of 16

for more: efesotomasyon - sanch inverter

Drive Solutions International

SANCH Inverter Series


Low noise, high performance,
multi-functional alternating
current inverters

SANCH ORGANISATION
for more: efesotomasyon - sanch inverter

Corporate introduction

SANCH Electric Corporation, together with three leading enterprises and several affiliated
organisations in China and Taiwan has been established to supply “Total Project Solutions” in Industrial
Automation. Sanch is geared to integrate the development, manufacture and systems engineering for
local and international clients alike.
Our professional teams of engineering, product development, manufacturing and integration staff,
devote themselves to the development and application of motor, electric, electronic, microelectronic,
information and control technology.
We continue to maintain close co-operation with scientific research institutions both at home and
abroad, in order to provide “intelligent” products that not only offer the best solutions, but also have a
“humanised” approach to functionality.
At present, our manufacturing capacity is over 100,000 devices per annum. This includes products
such as:
■ Industrial Human Machine Interface units (HMI)
■ A/C Frequency Inverters (INVERTER)
■ Intelligent Control Instruments
■ Programmable Logic Controllers (PLC)
■ Peripheral equipment for Industrial Process Control (IPC)
■ Microcomputer Controllers for various applications
■ and many others.
In order to service the Chinese market, we have already established dozens of marketing,
distribution agents and service organisations, to cover the Northern, Eastern, Central and Southern
areas. A Pathway Management System and CRM Customer Relationship Centre with high-efficiency
logistic and linkage service has also been established.
SANCH have already applied their range of products and services to the following industries; textile,
dye, ceramic, transportation, building, metallurgy, chemical, light, military, etc.
SANCH philosophy is to continually improve the electric management platform to account for all
facets of applications, thus maximising the competitiveness of technology, quality, service and
efficiently in accordance with the principle of satisfying our customers and creating excellent products.
SANCH actively promote a philosophy of maximising production outputs and yet minimising energy
consumption,using modern technological developments.
Our goal is to achieve “Automation–Energy Saving–Green World”, and we will try our best to
improve the environment and society as a whole.

Hsieh Yu Kuang – President

Corporate headquarters: Quanzhou, Fujian, Peoples Republic of China

TiV Technology • Interaction • Vitality


for more: efesotomasyon - sanch inverter

Technology
Interaction
Vitality

TiV
for more: efesotomasyon - sanch inverter

Products Introduction

Product Features
SANCH manufacture 4 series of alternating current motor drives: S800, SA, SE, S3000. All of them
incorporate high speed microprocessors and Sine-wave Pulse Width Modulation (SPWM) technology.
The drives utilize sensorless control by the Vector method with Voltage/Frequency being developed.
New generation IGBT components are used at the core of these units. This results in drives which are
smaller, more energy efficient and with a reduction of Electro-Magnetic Interference (EMI).

Model Instruction

S800 - 2 0 0 4 1 A
Name of Product Series: 2:220V Applicable motor: Input Voltage
Variable Frequency Drive capacity 1: 1-PHASE Version
002:0.2kW 3: 3-PHASE
004:0.4kW
007:0.75kW

S A - 4 0 5 5 B
Name of Product Series: 2:220V Applicable Power: Edition
Multifunctional and 4:440V 007:0.75kW 075:7.5kW
General- applications 015:1.5kW 110:11kW
022:2.2kW 150:15kW
037:3.7kW 185:18.5kW
055:5.5kW 220:22kW

S E - 2 0 0 4 1 A
Name of Product Series: 2:220V Applicable Power: Input Voltage
High performance and 002:0.2kW 1: 1-PHASE Edition
mini-type 004:0.4kW
007:0.75kW

S3000 - 300 G /370 P 43 A


Edition
Name of Product Series: Type of Frequency Inverter
Multifunctional Vector Type/ G: Constant Torque
Multifunctional Fan and Water pump P: Variable Torque Input Voltage
Applicable Power: 43:440V 3-PHASE
055:5.5kW 370:37kW
075:7.5kW 450:45kW
110:11kW 550:55kW
150:15kW 750:75kW
185:18.5kW 900:90kW
220:22kW 1100:110kW
300:30kW

1
for more: efesotomasyon - sanch inverter

Products Introduction

S800 Series
Low Noise High-Performance
■ Rated Voltage (V): 220V single/three phase ■ Power Range (kW): 0.2kW~0.75kW ■ Output Frequency: 1.0~400Hz
Features:
■ Compact and easy to install
■ Easy to operate
■ 4-level speed auto torque compensation
■ Auto slip compensation
■ Parameter locking/reset adjustable carrier
■ Uses interface design of port making wiring easier
■ Frequency setting potentiometer
■ RS-485 in-line with built in interface

SE Series
Mini-type with High-Performance and Low Noise
■ Rated Voltage (v): 220v single phase ■ Power Range (kW): 0.2 kW~0.75kW ■ Output Frequency: 1.0~400Hz
Features:
■ Compact and easy-to-install & operate
■ Frequency setting potentiometer attached to operator
■ Group parameters, easier operation
■ Adjusting accelerating/decelerating time automatically
■ Compact, 2HP (include that less than 2HP) is fan cooled
■ 4-Level speed and 4-level programmable operation
■ Modbus communication format
■ Parameters cipher-locked
■ S-curve, setting the accelerating/decelerating time independently

SA Series
Multifunctional and General Applications
■ Rated Voltage (V): 220V / single phase 220V/three phase 440V/phase
■ Power Range (kW):0.75~22kW ■ Output Frequency: 1.0~400Hz
Features:
■ Automatic torque compensation
■ RS-485 in-line interface build-in
■ 2-level accelerating/decelerating time
■ Automatic slip compensation, automatic voltage regulation (AVR)
■ 8-level preset table speed
■ Restart after instantaneous power-off
■ All-dimensional protection

S3000 Series
Multifunctional Vector Type/Multifunctional Fan and Water pump
■ Rated Voltage (V): 440V three phase ■ Power Range (kW): 5.5kW~110kW ■ Output Frequency: 0.1~400Hz
Features:
■ Automatic setting for acceleration / deceleration
■ 16-level preset table speed, switch of 4-level accelerating/decelerating time
■ RS-485 in-line interface build-in
■ Automatic control of motor parameters, precise location control
■ Automatic voltage regulation (AVR)
■ All-dimensional protection
■ Include PID circuit control
■ Senseless Vector control
■ Program and vector control of fan and water pump makes it more economical

2
for more: efesotomasyon - sanch inverter

Technical Specification
[S800 and SE Series]
Input Voltage S800 Single-phase 220V 0r 3 Phase 220V
SE Series Single-phase 220V
Model S800-2 1
002 004 007
Model SE-2 1
Applicable Motor Power (kW) 0.2 0.4 0.75
Rated output capacity (kVA) ) 0.6 1.0 1.6
Output

Rated output current (A) 1.6 2.5 4.2


Maximum output voltage (V) Three-phase corresponding input voltage
Range of output frequency (Hz) 1.0~400Hz
Power Supply

Rated input current (A) 4.9 6.5 9.7


Admissible variation range of Single-phase power supply 200-240V 50/60Hz
input voltage
Variation range of power ±5%
supply frequency
Control mode SVPWM spatial vector modulation (carrier frequency
3kHz~10kHz)
Control Characteristic

Resolution of output frequency 0.1Hz


Torque characteristic Torque and speed drop compensation function, trigger
torque can be up to 150% in 5Hz
Overload tolerance One minute under 150% of Rated output current
Accelerating and 0.1~600 seconds (can be set independently)
decelerating time
V/F curve Random V/F curve setting
Action adjustment to avoid Set by the percent of Rated current, 20~200%
losing speed
Panel operating Set by ▲ ▼ button or V, R
Frequency External signal Potentiometer 5kΩ / 0.5W, DC 0~+10V (input impedance
setting 47 kΩ), 4~20mA (output impedance 250Ω), multifunction
signal input selection 1~3 (3-level speed; jog, up/down
Operating Characteristic

instruction), communication setting


Operating Panel operating Set by RUN, STOP button
setting External signal MO,M1 ,M2, M3 combined to all sorts of mode to operate;
signal RS-485 communication port
Multifunction input signal Level speed instruction 0~3 selection, Jog instruction,
disable instruction of accelerating and decelerating,
switch instruction of first, second accelerating and
decelerating, counter, program running, selection of
external B.B. (NC, NO)
Multifunction output signal Operating frequency, setting frequency, counter reached in
operating, null speed, abnormal indication in B.B.,
LOCAL/REMOTE indication, program running indication
Other Functions AVR function, S-curve, avoiding over-voltage and over-
current speed losing, abnormal record check, carrier
frequency adjustment, reverse disable setting, direct
current setting, starting frequency setting, restart after
instantaneous power-off, upper and lower limits of
frequency, parameter locking / resetting
Protective Function Over-voltage, over-current, low-voltage, overload limits,
electronic thermocouple, overheat, self-check, ground
protection, abnormal port
Type of Cooling Air-blast cooling
Using location Lower than 1000m, indoor (keep from corrosive gases,
Environment

liquids and dust)


Environment temperature -10C~40°C (no dewing and icing)
Storage temperature -20°C ~60°C
Humidity Below 90%RH (no dewing)
Vibration 9.80665m/s2 below 20Hz (1G) 5.88 m/s2 below 20~50Hz (0.6G)

3
for more: efesotomasyon - sanch inverter

Terminal Wiring Diagram [S800 and SE Series]

Wiring part of alternating current motor drive is divided into main circuit and control circuit. User should connect
the circuitry according to the following wiring circuit.
The standard wiring diagram of default S800 and SE series alternating current motor drive is listed as follows. If
operated by digital control panel, there is only power circuit wiring terminal.

Main Circuit Power Supply


SE
MCCB
R(L1) R(L1)

S(L2) S(L2)

S800
MCCB
R(L1) R(L1) U/T1

S(L2) S(L2) V/T2 IM


3~
T(L3) T(L3) W/T3 Motor

Factory default
settings +18V
FWorward/Stop M0 4.7K
+18V RA
Multi-function indication output
Reverse/Stop M1 4.7K contacts
+18V 120VAC/28VDC3A
Reset M2 4.7K RC Factory default: fault indication
+18V
Multi-step 1 M3 4.7K
RJ-11
1:+EV
Common Signal GND 2:GND
3:SG-
➞ 4:SG+
6 1
Power Supply for Potentiometer RS-485
+10V 10mA MAX Communication port
Master Frequency Setting 3 Main circuit (power)
Anolog Voltage 2 terminal
VR AVI
0~10VDC
Control circuit terminal
VR:3k~5k 1
Analog current 4~20mA GND
Please use shielded cable

Note: Do not plug a Modem or telephone line to the RS-485 communication port, permanent
damage may result. Terminals 1 & 2 are the power source for the optional copy keypad and
should not be used while using RS-485 communication.

4
for more: efesotomasyon - sanch inverter

Specification [SA Series]

220V Single Phase/3 Phase series


Model SA- (_) 007 015 022
Maximum applicable output 0.75 1.5 2.2
power of motor (kW)
Maximum applicable output 1 2 3
power of motor (HP)
Output

Rated output capacity (kVA) 1.9 2.5 4.2


Rated output current (A) 5.0 6.5 11
Output frequency range 0.1~400HZ
Overload tolerance Keep 60 seconds under 150% of Rated output current
Maximum output voltage Corresponding input power supply
PH number, voltage, Single phase/ Three phase, 200-240VAC, 50/60Hz
frequency
Intput

Admissible variation range Voltage: ±15% frequency: ±5%


of voltage, frequency
Input current (A) 11/7.4 15/10 27/15
Cooling System Air-blast cooling

440V Single Phase/3 Phase series


Model SA- (_) 007 015 022 037 055 075 110 150 185 220
Maximum applicable output 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22
power of motor (kW)
Maximum applicable output 1 2 3 5 7.5 10 15 20 25 30
power of motor (HP)
Output

Rated output capacity (kVA) 2.3 3.2 4.2 6.3 9.9 13.7 18.3 24.4 28.9 34.3
Rated output current (A) 3.0 4.2 5.5 8.2 13 18 24 32 38 45
Output frequency range 0.1~400HZ
Overload tolerance Keep 60 seconds under 150% of Rated output current
Maximum output voltage Corresponding input power supply
PH number, voltage, Three phase, 380-480VAC, 50/60Hz
frequency
Intput

Admissible variation range Voltage: ±15% frequency: ±5%


of voltage, frequency
Input current (A) 4.2 6.0 7.2 8.5 14 20.6 28 30 39 49
Cooling System Air-blast cooling

5
for more: efesotomasyon - sanch inverter

Specification [SA Series]

Control mode Using SPWM spatial vector modulating technology


Output frequency range 0.1~400Hz
Frequency setting resolution 0.1Hz
Output frequency resolution 0.1Hz
Control Characteristic

PWM carrier frequency Adjust from 3kHz to 15kHz


Torque enhancing Automatic torque enhancement and automatic slip compensation, starting torque
can be up to 150% of rated torque in 2Hz
Jumping frequency Three points set from 0.1~400Hz
Accelerating/decelerating time 0.1~600 seconds (2-level accelerating/decelerating time can be set independently)
Avoid position of losing speed Set as 50~200% of rated current according to load characteristic of motor
Direct current braking Operating from 0.1-60Hz when stopped, braking current is 0-100% of rated
current, starting time is 0-5 seconds, stopping time is 0-25 seconds
Rising braking torque 20% (external optional braking resistor can be up to 125%) (built-in for 1-1 OHP
braking electro-crystal and external braking unit module for 15-60HP)
V/F curve Set table V/F curve

Frequency Digit operator Set by ▲ ▼ button


setting signal External terminal 0-5VDC/0-10VDC, 4-20Madc, in-line communication port (RS-485)
Operating Characteristic

Operating Digit operator Set by RUN STOP JOG button


setting External terminal 2-line (Fwd/Stop, Rev/Stop. Fwd/Rev) / 3-line operating, inching operation,
signal in-line communication port (RS-485)
Intelligent input terminal Switch of 8-level preset table speed, switch of first/second accelerating/
decelerating time; no external breaking input in accelerating/decelerating,
inching operation; increasing/decreasing frequency terminal setting,
count terminal
Intelligent output terminal Speed is not zero in operating when reached output frequency; external breaking
indication is displayed when counter and over-torque is outputted, low-voltage
checking, operating mode indication, abnormal fault output, external
abnormal breaking
Analog Signal Output Corresponding practical output frequency or output current
Fault Signal Port Connect “ON” when alternating current driver faulted (a relay with “C” terminal
or two open output)
Built-in Function Upper and lower limit setting of output frequency, restarting after instantaneous
power-off and abnormal fault; time setting of S curve accelerating/decelerating,
automatic voltage regulating output adjustment; digit frequency output signal,
abnormal record, parameter locking, parameter factory setting; prohibit reversal,
avoid losing speed under over-current and over-voltage, electronic
heat-driving electricity
Protection Function Over-voltage, over-current, low-voltage, external abnormal breaking input,
motor overload, ground over-current, overload and overheat of driver
Digit Operator Include eight function keys, 7-level display with five digits, 5-condition LED;
preset table frequency, practical output frequency and current displayed, user-set
unit; parameter browse, modification and locking, abnormal fault display; can
operating, stop, reset, positive/reversal, job
Operating environment -10˚C ~+40˚C (dust protector should be opened in +40˚C -+50˚C )
temperature
Environment

Storage temperature -20˚C -+60˚C


Operating environment humidity Below 90%RH (no dewing)
Mounting height Lower than 1000m, no corrosive gases, liquids, dusts
Vibrancy 9.80665m/s2 below20Hz (1G), 5.88 m/s2 in 20~5QHz (0.6G)

6
for more: efesotomasyon - sanch inverter

Terminal Wiring Diagram [SA Series]

Wiring part of alternating current motor is divided into main circuit and control circuit. User can
see the terminal of main circuit and control circuit after lifting the external cover. User should
connect the circuitry according to the following wiring circuit.
The standard wiring diagram of SA series alternating current motor drive is listed as follows.
If operated by digital control panel (IP-03, IP-05), there is only main circuit wiring terminal.

DC reactor
Braking Resisttance (Optional)

Short-Circuit Sheet

N P1 P B1
(+) / B2

R R U Induction Motor

Power Supply S S V

T T W
(Single-phase can be input by
any of the two terminals
Accessory Power Supply +EV Grounding

Multifunction input No. 1 1


M11

Multifunction input No. 2 1


M12 AFM

H
Multifunction input No. 3 1
M13

REV/STOP REV/STOP 2
REV ACM
6
2 Analog Frequency / Current Meter
FWD/STOP RUN/STOP
FWD RA
Abnormal Reset
RST 7
RB
External Abnormal Multifunctional Indication Output Port
EF below AC 250V 2A
RC
Input Signal Triggered by Counter 3 below DC 30V 2A
TRG

Digit Frequency Meter 4


MO1
DFM 8
Digit Signal Common Port Multifunctional PHC
DCM MO2
Output Port
below 48V 50mA
5 +10V
Analog Voltage 3 0V
Frequency Instruction MCM
AV1
0~+10V 2
1K~5K 1
AC1 SG+ Signal + Port
Analog Current
Frequency Instruction SG- Signal - Port
4~20mA ACM 9 Computer
Analog Signal Common Port RS-485 Serial
Communication Interface
AC MOTOR DRIVE

Main Circuit Terminal Control Circuit Terminal

7
for more: efesotomasyon - sanch inverter

Specification [S3000 Series]

Input Voltage Level 440V level


Model S3000-_______43__ 055 075 110 150 185 220 300 370 450 550 750
Apply for rated power of 3- φ
motor (kW) 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Apply for rated power of 3- φ
Output Rated

motor (HP) 7.5 10 15 20 25 30 40 50 60 75 100


Constant torque output
current (A) 13 18 24 32 38 45 60 73 91 110 150
Variable torque output
current (A) 16 22 30 40 47 56 75 91 1113 138 188
Rated output capacity (kVA) 9.9 14 18 24 29 34 46 56 69 80 100
Maximum output voltage(V) Three-phase power supply 380~440V corresponding to input voltage
Power

Rated input voltage/frequency 380/400/415/440 VAC three phase, 50/60 Hz


Operating voltage/frequency 340~500VAC, 47~63 Hz
Control system Selection of sine wave PWM
1: vector control; 2: torque control; 3: V/F control
Activating torque Activating torque is more than 150% in 0.5Hz
Control range of speed 1:100 (can be up to 1:1000 when have external PG)
Control precision of speed ±0.5% (can be up to ±0.02%)
Control Characteristic

Speed reactivity 5Hz (can be up to 30Hz under vector control)


Maximum output frequency (Hz) 0.00 to 400.00 Hz
Frequency output precision Digit instruction ±0.005%, analog instruction ±0.5%
Frequency setting resolution Digit instruction 0.01 Hz, analog instruction: maximum output frequency
is 1/1000 (bit)
Torque limit Maximum 200% torque current
Torque precision ±5%
Accelerating/decelerating time 0.00~600.00 seconds/ 0.0~6000.00 seconds
V/F curve Random V/F curve based on four points & quadratic curve
Frequency setting signal +10V, ± 10V, 4~20mA, pulse wave input
Dynamic brake About 20%
Motor protection Electronic thermocouple protection
Over-current protection Current restrain 170%, over-current protection 200% of rated current
Protection Characteristic

Ground protection for current Current leakage protection; 50% peak value of rated current
leakage
Overload capacity Constant/variable torque 150% for 60 seconds; 200% for 2 seconds
Voltage protection Over-voltage position: Vdc>400/800 V; low-voltage position: Vdc<200/400 V
Over-voltage protection for input Surge wave absorber (MOV)
power supply
Over-heat protection Built-in temperature sensor
Instantaneous power-off Parameter setting can be up to 5 seconds
compensation
Protection level NEMA1/IP21
Operating temperature -10°C~40°C for UL & -10°C~50°C for CE
Environment

Storage temperature -20°C~60°C


Humidity Below 90% RH (non-condensing)
Vibration 1 .OG below 20Hz, 0.6G at 20-60 Hz
Cooling system Air-blast cooling (RUN, STOP)
Mounting height Lower than 1000m,
Keep from corrosive gases, liquid and d
H
for more: efesotomasyon - sanch inverter

Terminal Wiring Diagram [S3000 Series]

Wiring part of frequency inverter is divided into main circuit and control circuit.
User can see the terminal of main circuit and control circuit after removing the casing cover.
User should connect the circuitry according to the following wiring circuit
The standard wiring diagram of S3000 is listed as follows:

Braking Resistance (Optional)

Breaker without Fuse Wire


P1 P2 B
NFB R(L1)
R
S S(L2) U(T1) Motor
T T(L3)

SA V(T2) M
MC
RB 3~
Recommended protection
circuit for abnormal or RC W(T3)
OFF ON
instantaneous power-off
MC

24V
Factory setting is ‘Sink’ RA
FWD Multifunctional 240VAC 2.5A
FWD/Stop
RB Contact Output 120VAC 5A
REV 24VDC 5A
REV/Stop
RC
Multifunctional Input Terminal

Mi1 Factory setting is ‘Fault Instruction’


Multi-level Speed Instruction 1
Mi2 MRA Factory setting is ‘Instruction in
Factory setting

Multi-level Speed Instruction 2 Operating’


Mi3 MRC
Multi-level Speed Instruction 3 Multifunctional Contact Output
Mi4 (Open Output) 48VDC50mA
Multi-level Speed Instruction 4
Mo1 Factory setting is ‘Frequency Reach
Mi5
Multi-level Speed Instruction 5 Indication’
Mi6
Multi-level Speed Instruction 6
DCM
Common Terminal of Digit Signal
Mo2 Factory setting Is ‘Driver Ready
Sink Mode Indication’
*Voltage can’t be directly input to the above signal
Optical Coupling Output Common
+10V MCM Port
Power Supply for Frequency Setting
3 +10V 20mA Digit Frequency Output Terminal
DFM
5K 2 AVI Factory magnification is set as 1:1
Main Speed Instruction
1 0~10V (47KΩ) Duty=50%10VDC
Digit Signal Common Terminal
4~20mA DCM
ACI Multifunctional Analog Output
-10~+10V AFM Terminal
AUI Factory Setting is ‘Output
Analog Signal Common Port Frequency’
ACM
0~10VDC/2mA
ACM
Analog Signal Common Port
RS-485
Serial Communication

*Communication pin definition: pln1:no connected pin2: GND pin3: SG- pin4: SG+ pin5:/pin6: no connected

9
for more: efesotomasyon - sanch inverter

Overall Dimension Drawing

S800 SE Series
C UNIT: mm

H2
H1
H
H1
H

D1

C W1 D1
W D
W1 W

Model H H1 H2 W W1 D D1 C
S800-20021A
S800-20041A 135.3 123.9 – 72.7 59.7 140.5 132.2 4.6
S800-20071A
SE-20021A
SE-20041A 132.0 126.1 48.5 68.0 61.9 131.0 122.0 5.0
SE-20071A

SA Series
UNIT: mm
C H1 LENGTH W W1 H H1 D C mass
remark
MODEL mm kg
SA-2007B
SA-2015B
SA-4007B
W1

SA-4015B
126.5 113.6 174 159.4 144.5 5.5 1.55
SA-4022B
SA-4007C
SA-4015C
SA-4022C
H
SA-2022
SA-4037 190.5 175.1 225 207.2 159 5.5 2.55
SA-4055
SA-2022B
132 119.5 236 205 163 5.5 3.0
D

SA-4037B
Using fan

SA-4037C
132 119.5 236 205 171 5.5 3.9
SA-4055C
SA-4055B
132 119.5 236 205 192 5.5 4.0
SA-4075C
SA-4075 7.0
203.3 185.3 323.3 308 180 6.5
SA-4110 7.5
SA-4075B
SA-4110B 200 186.2 320 300.6 194.5 7.0 6.0
SA-4150C
SA-4150
10.5
SA-4150B
SA-4185
250 225.5 403 3835 216 5.5 11
SA-4185B
SA-4220
SA-4220B

10
for more: efesotomasyon - sanch inverter

Overall Dimension Drawing

3000 Series (7.5HP ~ 10HP)


UNIT: mm

W D W1
C
H

H1
Model H H1 W W1 D C
S3000-055G/075P43A
320 300.6 200.2 186.2 194.5 7.0
S3000-075G/110P43A

3000 Series (15HP ~ 30HP)


UNIT: mm

W1 C
H
H1

D
W

Model H H1 W W1 D C
S3000-110G/150P43A
S3000-150G/185P43A
403 383.5 250 225.5 216 10.0
S3000-185G/220P43A
S3000-220G/300P43A

11
for more: efesotomasyon - sanch inverter

Overall Dimension Drawing

3000 Series (40HP ~ 50HP)


UNIT: mm
W D
W1 C
H1
H

W2

Model H H1 W W1 W2 D C
S3000-300G/370P43A
553 530 266 210 180 277.1 10
S3000-370G/450P43A

3000 Series (60HP ~ 75HP)


UNIT: mm
W D
W1 C
H1
H

W2

Model H H1 W W1 W2 D C
S3000-450G/550P43A
652.6 630 2308.2 250 220 282 10
S3000-550G/750P43A

12
for more: efesotomasyon - sanch inverter

Drive Solutions International

International Office
Phone: +61 3 9795 2887
Fax: +61 3 9795 7882
Mobile: +61 419 424 246
Business Centre
Room 505, Fudan Technology Building
11, Guo Tai Road, Shanghai, 200433 PRC
Phone: +86 21 5169 6555
Fax: +86 21 6140 0501
Factory Headquarters
3, Zixin Road, Jiangnan High Tech Park
Licheng District, Quanzhou City, Fujian
Province PRC
Phone: +86 595 2898 3312
Fax: +86 595 2898 3388

Contents subject to change without notice

SISC2006

You might also like