Location of the Project : 28⁰ 32' 30" to 28⁰ 33' 40" N

83⁰ 36' 40" to 83⁰ 39' 08" E


Power Development
Capacity : 4.00 MW
Type of Power : Run-of-river
Generation
Turbine Discharge : 1.0 m³/s
Gross Head : 489.70 m
Net Head : 474.76 m
Installed Capacity : 4 MW
Average Annual Energy : 22.07 GWh (before 5% outage and losses)
Dry Energy : 3.29 GWh
Wet Energy : 17.58 GWh
Weir
Type of Weir : Ogee
Size of Weir : 10.5m x 7.0m x 4.0m (LxWxD)
Weir Crest Level : EL. 2256.50m
Geology : Formation I of Higher Himalaya Weir axis
is covered by thick alluvial deposit of
boulder and cobble and is composed of
gneiss, quartzite and schist
Spillway
Type : Overflow
Maximum Flood Level : EL 2256.50 m
(1:100 yr)
Width : 10.5 m
Flood Discharge (1:100 : 50.00 m³/s
yrs)

Headrace Canal

Size of Canal : 1.85m x 1.2 m

Bed Slope : 1 in 20

Length : 21.50 m

Gravel Trap

Section : Rectangular
Size (W x H) : 2.5 m x 2.1 m

Length : 8.00 m

Spillway Type : Overflow side spillway

Spillway Length : 5.00 m

Spillway Crest Level : 2,253.73 m

Gravel Flushing Gate Size : 1 x 0.30 m x 0.30 m

Water Conveyance System

Headrace Pipe

Type : Exposed

Material : Steel

Length : 1,440.00 m

Diameter : 0.90 m

Thickness : 6.00 mm

Hydraulic Slope : 1:500

Geology : Rocks of gneiss and schist


with less than 3 m thick
colluvial deposit
Desander

Type : Dufour, continuous flushing

Size (Lefx B x H) : 40.00 m x 3.30 m x 3.00 m

Desander chamber : 2 No.

Particle size to be settled : 0.15 mm

Trap Efficiency : 95%

Flushing Gate Size : 2x 0.50 m x 0.50 m

Overflow Spillway Crest : 5.0 m


Length
Flushing Canal Length : 15m

Surge Shaft
Type : Inclined Surface Surge Shaft
Length : 45m³
Diameter : 1.50 m
Invert Level : EL 2,246.92 m
Geology : Moderately sloped with thick deposits of
colluvium and residual soil.
Penstock
Type : Exposed
Material : Steel
Length : 1,120.00 m
Diameter : 0.70 m
Thickness : between 22.00 mm and 25.00 mm
Manifolds (L x D x Nos) : 10.27 m x 0.5 m x 2 Nos.
Geology : Covered by < 2 m thick colluvial deposits
Powerhouse
Type of Powerhouse : Surface
Size ( L x B x H) : 20.00 m x 10.60 m x 9.20 m (roof ridge)
Geology : Rocks of Formation I, area covered by
colluviums deposits.
Turbine
Type of Turbine : Pelton
No. of Units : 2
Axis : Horizontal
Number of Jet : 2
Turbine Axis Level : EL 1,764.00 m
Rated Speed : 1,500 rpm
Generator

Type of Generator : Synchronous AC 3 phase


Horizontal shaft
Max Rated Capacity : 2 x 2,500 kVA

Rated Voltage : 6.6 KV

Switchyard

Type : Outdoor, 2 units


Power Transformers : 6.6/33 kV, 3 phase

Main Transformer and Service Transformer

Type : Oil immersed self-cooled outdoor


type
Rated Capacity : 2,500 kVA

Number of Units : 2

Frequency : 50 Hz

Number of Phase : 3 phase

Transmission Line : 3.50 km long 33 kV single circuit


with Dog conductors connected
to Dana Substation
Tailrace

Section : Rectangular

Size (W x H) : 1.2 m x 0.9 m

Length : 32 m

D Shaped Tunnel : 90 m

Hydraulic Slope : 1:250

Important Project Information and Dates


S. No. Description of Works Date/Information
1. PPA Date 2071/12/17
2. RCOD 2076/08/02
3. Financial Closure Date as per PPA -
4. Actual Financial Closure Date 29/12/2071 (12 April 2015)
5. Generation License Date 2071/01/05
6. Expected COD 2076/08/02
Dana Substation at Dana in Myagdi District, 220
7. Connection Point, Voltage Level
kV TL
8. Project Location Annapurna Gaunpalika Ward No. 3, Myagdi
(Formerly Dana VDC 1&2, Myagdi)