Cutler-Hammer Low-Voltage Distribution Equipment F3-1

January 1999 Meter Centers


General Description – Meter Breaker Panels

WMB101224S CGBT2125S

WMB101224S CGBT30M2F

Description Specifications ■ Surface units are supplied with


mounting tabs.
Service entrance equipment that Ratings single-phase, 3-wire,
■ Molded bus supports assure rigid
combines meter sockets and a 120/240 volts ac; 100 through 225
construction and security of bus
circuit breaker distribution section ampere main breaker and main lug
bars.
in a rainproof enclosure. In addition types; 10,000 amperes rms symmet-
to residential installations, Cutler- rical short circuit rating. ■ Flat deadfront and sealable pull
Hammer meter-breakers are equally section contain captive screws.
applicable for rural service entrance, Features ■ Lockable distribution cover. Dead-
mobile homes, and for temporary front has a lifting handle.
power on construction sites. ■ Both BR and CH type branch
They are listed by Underwriters circuit breakers are available. ■ Raised distribution panel and
Laboratories, Inc., File No. E52977. increased wireway space speed
■ Overhead or underground installation and wiring of branch
service. circuit breakers.
Cutler-Hammer meter sockets con- ■ Meets latest NEC wire bending
form to UL Specification 414 and space requirements.
AEIC-EEI-NEMA standards (MSJ-7). 100 and 125 Ampere Devices
Neutrals are factory bonded to the ■ Fifth jaw can be installed in the
■ Center feed main breaker high-
enclosure. These meter-breaker 3 o’clock or 9 o’clock position.
lights this all-new distribution
combinations fulfill EUSERC Utility ■ Slotted sealing screws at hub section. Even distribution of load
requirements except as noted. with sealing position provided. and cooler operating ambient
Two styles are available so that ■ Semi-flush with nail flange or increase component reliability.
either BR or CH type branch breakers surface mounting. ■ Compact enclosure is light in
can be used. Units are rated 10,000 ■ Meter mounting and under- weight for easy installation.
AIC. Ground bars are available for ground pull sections are utility
field installation. sealable.
■ Meter socket ring landing will
Further Information
accept locking security rings. CAT.73.01.T.E

CAT.71.01.T.E
F3-2 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

General Description – Residential Commercial Meter Stacks

Numbering System for Cutler-Hammer


Multiple Metering Products
Residential Modular Metering Stacks
1 MM 4 12 R RLB
Phases Blank = Ring
1 or 3 RL = Ringless
RLB = Ringless with
Type of Metering Horn Bypass
MM = Multiple Metering WB = Wall Bracket
BSK = Bussed Spacer
Enclosure EB12 = 12-inch Elbow
Number of Meters R = Outdoor EB16 = 16-inch Elbow
2, 3, 4, 5 or 6 Ampere Rating Blank = Indoor
Meter Center Types Blank = Accessory 12 = 125 Amps
20 = 200 Amps
Blank = Accessory
Meter Packs
Used in applications where there are
six or less tenants which require Commercial Modular Metering Stacks (35MM, 37MM, 35SS and 37SS)
sockets for utility metering. Meter
Packs are self-contained assemblies 3 7 MM 1 20 R 12
and include a utility termination
F compartment for incoming cables
3-Phase
Only
12 = 1200A Main
Bus Ampacity
which is integral to the device. AB = Phases A&B
Number of Jaws AC = Phases A&C
This product is typically installed at BC = Phases B&C
5 or 7
residential apartment complexes, Enclosure
duplexes, triplexes, etc., in single- Type of Metering R = NEMA 3R
phase, 120/240 volt, 600 ampere MM = Commercial
Metering Module
maximum ratings. SS = Safety Socket Socket Amperage
20 = 200 Amps
Meter Stacks Number of Meters 40 = 400 Amps
1, 2, 3 or 4
Residential 1MM and 3MM Stacks
As with meter packs, modular Meter Packs
metering is typically installed at
residential apartment complexes, 1 MP 4 12 2 R
duplexes, triplexes, etc. However, 1 Phase R = Ring
modular metering allow for as many RRL = Ringless
sockets as needed to fit the particu- Type of Metering RRLB = Ringless with
MP = Meter Pack Horn Bypass
lar application. These devices can be LK = Lug Kit
ordered with any main device (MTB, SC = Crimp Lug
Number of Meters Landing
MCB, MFS, or BPS) for main discon- 2, 3, 4, 5 or 6 Bus Amp Rating
2 = 200 Amps Pad Kit
nect or electrical protection. Blank = Accessory Ampere Rating
4 = 400 Amps SFK = Semi-Flush
12 = 125 Amps
6 = 600 Amps Flange Kit
Commercial 35MM, 37MM, 35SS, 20 = 200 Amps
Blank = Accessory Blank = Accessory
and 37SS Stacks
These devices are primarily used in
light commercial applications such Main Service Modules
as strip malls, office complexes, and 3 MTB 800 R BLK
industrial parks. In addition to the
residential stacks (1MM and 3MM) Phases BLK = Box Lug Kit
1 or 3 CLK = Compression Lug
these devices can be ordered with B = Bottom Feed
any main device (MTB, MCB, MFS, Type of Metering Enclosure T = Top Feed
or BPS) for a main disconnect or MTB = Main Terminal Box R = NEMA 3R UG = Pull Box
electrical protection. MCB = Main Circuit Breaker
BPS = Bolted Pressure Switch
MFS = Main Fusible Switch
UGPB = Underground Pull Box Ampere Rating
400 = 400 Amps 1200 = 1200 Amps
600 = 600 Amps 1600 = 1600 Amps
800 = 800 Amps 2000 = 2000 Amps

CAT.71.01.T.E
Cutler-Hammer Low-Voltage Distribution Equipment F3-3
January 1999 Meter Centers
Technical Ratings – Residential and Commercial Meter Stacks

Meter Packs
Description Features of Meter Packs
■ 1MP units are self-contained ■ Indoor/outdoor construction.
(main terminal box included) for ■ Provision for 2-pole breaker
installations requiring up to six (plug-on type for 125A sockets
meter socket positions in a single and bolt-on type for 200A
enclosure. sockets).
■ Units are not gangable with any ■ Overhead, underground, and back
other metering device. tenant feeds.
■ Approved by major power com- ■ Series rating up to 100,000 AIC.
panies. UL listed and meets the
service and electrical require- ■ Bondable neutral.
ments of EUSERC and CECHA. ■ 120/240 Vac, 1-phase 3 wire
■ All ringless devices include 5th metering device.
jaw as standard. ■ 600A max. horizontal bus rating.
■ Applications:
Garden apartments and town
houses
Duplex, triplex, quadplex F
construction
Small condominiums.

Mains
Description
■ Offering: main terminal/lug com- ■ Mechanically and electrically built
partment, main circuit breaker, for use with 1MM, 3MM, 35MM,
main fusible switch, main bolted 37MM, 35SS, and 37SS stacks.
pressure switch, main fusible Due to 800A cross bus rating on
switch with pullbox (meets 1MM and 3MM devices if main is
EUSERC electrical requirements), rated higher than 800A, stacks
cable tap box – termination must be center fed from the main.
compartment without cross bus
(meets EUSERC electrical Due to 1200A cross bus rating on
requirements) 35MM, 37MM, 35SS, and 37SS
devices, if main is rated higher
than 1200A, stacks must be center
fed from the main.

Features of Main Device


■ System Application ■ Main device rating ■ All main devices are suitable for
Single-phase, 3-wire tenant meter- Main terminal box, 400-1200A indoor or outdoor application.
ing through 3MM, 35MM, 35SS ■ Knockouts provided in bottom
Molded case circuit breaker,
meter socket modules from 120/ endwall of enclosures.
400-2000A
240V, 1-phase, 3-wire system or ■ Metering modules may be bolted
208Y/120V, 3-phase, 4-wire net- Fusible switch, 400-1200A to one or both sides of the main
work metering. device.
Bolted pressure contact switch,
Three-phase, 4-wire tenant meter- 1200-2000A
ing through 37MM or 37SS meter
socket modules from 208Y/120V,
3-phase, 4-wire or 240/120V,
3-phase, 4-wire delta system.

CAT.71.01.T.E
F3-4 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

Technical Ratings – Residential and Commercial Meter Stacks

Residential Stacks (1MM, 3MM)


Description
■ Mechanically and electrically built ■ Applications:
to bolt up to mains and commer- Garden apartments (if 6 disc or
cial stacks. less, use 1MP, greater than 6 disc
■ Offered with four horizontal cross order appropriate main and resi-
buses (for 3-phase incoming dential stack)
voltage).
Large condominiums.
■ All ringless devices include 5th
jaw as standard.

Features of 1MM/3MM
■ 1MM and 3MM system applica- ■ Choice of 2-pole tenant circuit ■ Choice of ring or ringless type
tion – single-phase 3-wire meter- breaker types. meter socket covers.
F ing on 120/240V, 1-phase, 3-wire
systems.
125A plug-on: ■ Removable backwall knockout
plates are standard on all meter
Type BR – 60 through 125
■ 3MM system application (only) – modules.
amperes – 10,000 AIC
single-phase network metering ■ Can be mounted with 35MM,
on 208Y/120V, 3-phase, 4-wire Type BRH – 60 through 125 37MM, 35SS, and 37SS – will bolt
systems. amperes – 22,000 AIC together in many different
Field phase balancing easily Type BRHH – 100 through 125 arrangements.
accomplished – front accessible amperes – 42,000 AIC ■ UL listed – suitable for use as
■ All 1MM and 3MM modules have Service Entrance Equipment.
200A bolt-on:
800A cross bus
Type WCC – 100 through 225
1MM devices include three cross
amperes – 10,000 AIC
buses (A, B, and N)
Type WCHH_H2X – 60 through 225
3MM devices include four cross
amperes – 25,000 AIC
buses (A, B, C, and N)
Type WCHH_H4X – 60 through 225
■ Offered with indoor and outdoor
amperes – 42,000 AID
enclosures.
■ Slip together, captive-bolt joint Type WCHH_X – 60 through 225
design interconnects with 1200A amperes – 100,000 AIC
cross bus in 35MM and 37MM ■ Separate breaker compartment
devices, 800A cross bus in 35SS with enclosed cross bus, and
and 37SS devices. separate meter socket covers,
■ Choice of 125A maximum (plug- provide access for tenant addi-
on) or 200A maximum (bolt-on) tions while maintaining power
tenant breaker modules. metering security of installed
equipment.

CAT.71.01.T.E
Cutler-Hammer Low-Voltage Distribution Equipment F3-5
January 1999 Meter Centers
Technical Ratings – Residential and Commercial Meter Stacks

Commercial Stacks (35MM, 37MM, 35SS, and 37SS)


Description
■ Mechanically and electrically built ■ All commercial stacks contain
to bolt up to mains and residential four horizontal cross buses.
stacks. ■ Applications:
■ 35MM and 37MM stacks contain Strip malls
meter blocks with test bypass and
jaw release. Light commercial multiple
metering projects.
■ 35SS and 37SS stacks utilize
meter socket with test bypass
feature (meets EUSERC electrical
requirements).

Features of 35MM, 37MM, 35SS,


and 37SS (Commercial Multiple
Metering) F
■ 35MM and 35SS system applica- ■ 35SS modules are equipped with Type WCHH_X – 60 through 225
tion – 120/240V, 1-phase, 3-wire a EUSERC approved 1-phase ring amperes – 100,000 AIC
systems and 208Y/120 volt net- style meter socket and test blocks.
Short circuit ratings from 10,000
work metering. ■ 37SS modules are equipped with through 100,000 AIC using
■ 37MM and 37SS system applica- a EUSERC approved 3-phase ring WCHH_X tenant breakers. These
tion – 208Y/120V, 3-phase, 4-wire style meter socket and test blocks. breakers are series rated to protect
delta systems. ■ Combination indoor/outdoor standard 10,000 AIC Cutler-Ham-
■ 35MM and 37MM incorporate enclosures with removable top mer breakers in downstream
1200A cross bus and 35SS and cap, bottom plate and back plate loadcenters or panelboards
37SS contain 800A cross bus. for field installed knockouts (all Can be mounted with 1MM/3MM
Both designs can be intercon- blank plates). modules – will bolt together in
nected wih all other commercial ■ Choice of 2- or 3-pole tenant many different arrangements.
metering as well as residential circuit breaker types:
(1MM and 3MM devices). UL listed – suitable for use as
Type WCC – 100 through 225 Service Entrance Equipment.
■ 35MM are equipped with 1-phase amperes – 10,000 AIC
5-jaw, lever bypass, and jaw
release meter sockets. Type WCHH_H2X – 60 through
225 amperes – 25,000 AIC
■ 37MM are equipped with 3-phase,
7-jaw, lever bypass, and jaw Type WCHH_H4A – 60 through
release meter sockets. 225 amperes – 42,000 AIC

CAT.71.01.T.E
F3-6 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

Technical Ratings – Residential and Commercial Meter Stacks

Series Combination Short Circuit Rating


General 1MM, 3MM 125A Meter Module 1MM, 3MM, 2000A Meter Modules,
When tenant breakers are installed When used with Main Switch, main 35MM, 37MM, 35SS and 37SS
in Cutler-Hammer metering mod- breaker, or main lug modules, this 225A Meter Modules
ules per the short circuit current meter module is UL listed for the When used with Main Switch, main
ratings below, the branch breakers short circuit rating at 240 Vac maxi- breaker, or main lug modules, these
installed in the Cutler-Hammer mum in rms symmetrical amperes meter modules are UL listed for the
downstream panel rated 10,000 AIC per table below. short circuit rating at 240 Vac maxi-
or greater are protected to the listed mum in rms symmetrical amperes
Tenant Breaker Amperes UL Listed Series
series AIC rating. Refer to the down- Catalog Number Maximum Short Circuit per table below.
stream panel marking for the proper 2-Pole Rating
Tenant Amperes UL Listed
series combination short circuit BRHH_____ 125 42,000 Breaker Maximum Series
ratings. These ratings apply to both BRH_____ 125 22,000 Catalog Short
1MM 35MM,
BR_____ 125 10,000 Number
200A 37MM,
Circuit
loadcenter types BR and CH. 2 -or 3-Pole
35SS, 37SS
Rating
When Type BRHH or BRH tenant 225A
The short circuit rating is limited to
breakers are installed in this meter CHH 200 225 100,000
the lowest interrupting rating of any
module, then Cutler-Hammer break- CHH_____H4 200 225 42,000
tenant breaker installed or to the CHH_____H2 200 225 25,000
ers rated 10,000 AIC or greater CC 200 225 10,000
lowest marked interrupting rating of
installed on the load side of this
the main switch, main breaker, or
meter module may be protected for When Type CHH tenant breakers are
main lug modules.
F short circuits up to 22,000 AIC with installed in these meter modules,
then Cutler-Hammer breakers rated
Replacement or additional breakers Type BRH breakers or 42,000 AIC
shall be of the same type and manu- with Type BRHH breakers. 10,000 AIC or greater installed on
facturer and shall have an interrupt- the load side of these meter mod-
See load side breaker panel marking
ing rating equal to or greater than ules may be protected for short
for proper short circuit current
the interrupting rating of any tenant circuits up to 100,000 AIC.
rating.
breaker presently installed in the
See load side breaker panel marking
meter module.
The Watt-Hour Meter is not for proper short circuit current
Included in the Short Circuit rating.
Current Rating (Per UL67).

The Watt-Hour Meter is not


Included in the Short Circuit
Tenant Downstream Panel Current Rating (Per UL67).
Breaker (Type CH or BR)

Load Side Tenant Downstream Panel


Main Meter
Breakers Breaker (Type CH or BR)
Module Module

Main Meter Load Side


Module Module Breakers

CAT.71.01.T.E
Cutler-Hammer Low-Voltage Distribution Equipment F3-7
January 1999 Meter Centers
Technical Ratings – Residential and Commercial Meter Stacks

Series Combination Short Circuit Rating


1MP 125A Meter Module 1MP 200A Meter Module
This All-In-One Meter Module is UL This All-In-One Meter Module is UL
listed for the short circuit rating at listed for the short circuit rating at
240 Vac maximum in rms symmetri- 240 Vac maximum in rms symmetri-
cal amperes per table below. cal amperes per table below.
Tenant Breaker Amperes UL Listed Series Tenant Breaker Amperes UL Listed Series
Catalog Number Maximum Short Circuit Catalog Number Maximum Short Circuit
2-Pole Rating 2- or 3-Pole Rating

BRHH_____ 125 42,000 CHH_____ 200 100,000


BRH_____ 125 22,000 CHH_____H4 200 42,000
BR_____ 125 10,000 CHH_____H2 200 25,000
CC_____ 200 10,000
When Type BRHH or BRH tenant
breakers are installed in this meter When Type CHH tenant breakers
module, then Cutler-Hammer break- are installed in this meter module,
ers rated 10,000 AIC or greater then Cutler-Hammer breakers rated
installed on the load side of this 10,000 AIC or greater installed on
meter module may be protected for the load side of this meter module
short circuits up to 22,000 AIC with may be protected for short circuits
Type BRH breakers or 42,000 AIC up to 100,000 AIC.
with Type BRHH breakers. See load side breaker panel marking F
See load side breaker panel marking for proper short circuit current rating.
for proper short circuit current rating.

The Watt-Hour Meter is not The Watt-Hour Meter is not


Included in the Short Circuit Included in the Short Circuit
Current Rating (Per UL67). Current Rating (Per UL67).

Downstream Panel Downstream Panel


All-In-One (Type CH or BR) All-In-One (Type CH or BR)
Meter Tenant Meter Tenant
Module Breaker Module Breaker

Load Side Load Side


Breakers Breakers

The above ratings for both 125A and 200A tenant positions apply to both type BR and
CH loadcenters and 10,000 AIC branch breakers.

CAT.71.01.T.E
F3-8 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

Technical Ratings – Residential and Commercial Meter Stacks

Series Combination Short Circuit Rating The Watt-Hour Meter is not


Included in the Short Circuit
General listed series AIC rating. Refer to the Current Rating (Per UL67).

The table below lists the specific downstream panel marking for the
downstream loadcenter branch proper series combination short Tenant Downstream Panel
Breaker (Type CH or BR)
breakers that may be series rated circuit ratings.
with upstream tenant breakers. Replacement or additional breakers Load Side
When tenant breakers are installed shall be of the same manufacture
Main
Module
Meter
Module Breakers
in Cutler-Hammer metering mod- and type and shall have an interrupt-
ules per the table below, the branch ing rating equal to or greater than
breakers installed in the Cutler-Ham- the interrupting rating of any tenant
mer downstream panel rated 10,000 breaker installed.
AIC or greater are protected to the

Series Combination Short Circuit Ratings – 240 Volts Ac


Main Module Meter Module Tenant Feeder Breaker Type Tenant Feeder Loadcenter Branch Breaker System AIC
Overcurrent Device 1MM, 3MM, 35MM, 37MM, 35SS, 37SS Breaker Short (1- or 2- Pole) Rating
Breaker Type or Class Fuse or Loadcenter Main Breaker Circuit Rating 120/240V ac Max

None None BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 10000
Without Main BR_, WCC_, BW_ 10000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 10000
Disconnect.
BRH_ 22000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22000
F Cable Tap Box Type
MTB, UGTB BWH_, WCHH_H2 25000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 25000
BRHH_, WCHH_H4 42000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 42000
WCHH_ 100000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 100000
Main Switch Module BR_, WCC_, BW_ 10000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 10000
Type MFS With Class T
Fuse, 800A Max BRH_ 22000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22000
BRH_ 22000 BD, BR, BRD, BQ, BQC, GFCB 100000➀
BWH_, WCHH_H2 25000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 25000
BRHH_, WCHH_H4 42000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 42000
BRHH_, WCHH_H4 42000 BD, BR, BRD, BQ, BQC, GFCB 100000➀
WCHH_ 100000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 100000
Main Switch Module BR_, WCC_, BW_ 10000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 10000
Type BPS
With Class L Fuse, BRH_ 22000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22000
1200A-1600A BWH_, WCHH_H2 25000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 25000
BRHH_, WCHH_H4 42000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 42000
WCHH_ 100000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 100000
Main Breaker Module BR_, WCC_, BW_ 10000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 10000
Type MCB With
LC, LD, LSE (600A Max) BRH_ 22000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22000
MC, MA (800A Max) BWH_, WCHH_H2 25000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 25000
BRHH_, WCHH_H4 42000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 42000
Main Breaker Module WCHH_ 100000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 100000
Type MCB With ND
1200A Max BRHH_ 42000 BD, BR, BRD, BQ, BQC, GFCB 65000

Main Breaker Module BR_, WCC_, BW_ 10000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 10000
Type MCB With
LHE, HLD, LDC (600A Max) BRH_ 22000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22000
MAY (800A Max) BWH_, WCHH_H2 25000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 25000
NBY, HND, NDC (1200A Max)
BRHH_, WCHH_H4 42000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 42000
WCHH_ 100000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 100000

➀ 100,000 with Class T fuse, 600A maximum

CAT.71.01.T.E
Cutler-Hammer Low-Voltage Distribution Equipment F3-9
January 1999 Meter Centers
Dimensions and Knockouts

Main Service Modules


Bottom Feed Fusible Switch and Combination Fusible
Main Circuit Breakers, Terminal Boxes, and Pull Boxes Switch with Pull Box

A A C

E B E B

F F

C D 17.000
D (431.80)
Main CB, Terminal Box and Pullboxes Bottom Feed Switch and Combination Switch/Pullbox

F
Top Feed Fusible Switch Bolted Pressure Switch

A C
A C

E B
E B

F
F

D 17.000
(431.80) D 25.000
(635.00)
Top Feed Switch (No Knockouts)

See page F3-10 for dimensions.

CAT.71.01.T.E
F3-10 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

Dimensions and Knockouts

Approximate Dimensions (not to be used for construction purposes)


Main Device Width Height Depth Mounting Center Line of Knockouts in Bottom Endwalls Except No
Wall Mounting KOs for Top Feed Switch or Bolted Pressure
Bracket Switch Conduit Diameter-Inches
A B C D E F
Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm Inches mm

Terminal Box (1) 2-1/2–3– (1) 63.50–76.20–


400 and 600 Ampere 13-1/2 342.50 48-3/4 1238.25 7 177.80 0 – 54 1371.60 30-5/8 777.88 3-1/2, 4, (1) 1/2 88.90–101.60 (1)
12.70

800 and 1200 Ampere 20 508.00 47-5/8 1209.68 11-3/4 298.45 12 304.80 51-1/2 1308.10 30-5/8 777.88 (2) 1/2–3/4–1, (2) 12.70–19.05–25.40
(4) 2 2-1/2–3– (4) 50.80–63.50–
3-1/2–4 76.20–88.90–101.60
Main Circuit Breaker with 20 508.00 47-5/8 1209.68 11-3/4 298.45 12 304.80 51-1/2 1308.10 30-5/8 777.88 (2) 1/2–3/4–1, (2) 12.70–19.05–25.40
Box Lugs (4) 2 2-1/2–3– (4) 50.80–63.50–
400 Ampere – 1200 Ampere 3-1/2–4 76.20–88.90–101.60
Main Circuit Breaker with 24-7/8 631.83 57-1/8 1450.98 14-7/8 377.83 16 406.40 57-1/8 1450.98 44 1117.60 none
Box Lugs 1400 Ampere –
2000 Ampere
Main Circuit Breaker with 20 508.00 61 1549.40 11-3/4 298.45 12 304.80 65 1651.00 44 1117.60 (2) 1/2–3/4–1, (2) 12.70–19.05–25.40
Compression Lugs (4) 2 2-1/2–3– (4) 50.80–63.50–
400 Ampere – 1200 Ampere 3-1/2–4 76.20–88.90–101.60
Main Fusible Switch – 20 508.00 47-5/8 1209.68 11-3/4 298.45 12 304.80 51-1/2 1308.10 30-5/8 777.88 (2) 1/2–3/4–1, (2) 12.70–19.05–25.40
Bottom Feed (4) 2 2-1/2–3– (4) 50.80–63.50–
F Main Fusible Switch – 20 508.00 47-5/8 1209.68 11-3/4 298.45 12 304.80 51-1/2 1308.10 18-1/8
3-1/2–4
460.38 (2) 1/2–3/4–1,
76.20–88.90–101.60
(2) 12.70–19.05–25.40
Top Feed (4) 2 2-1/2–3– (4) 50.80–63.50–
3-1/2–4 76.20–88.90–101.60
Main Fusible Switch – 33-1/2 850.90 52-3/4 1339.85 11-7/8 301.63 16 406.40 56-1/4 1428.75 30-3/4 781.05 (5) 3-1/2–4–5, (5) 88.90–101.60–
1200 Ampere (1) 3/4–1–1-1/4– 127.00 (1) 19.05–
1-1/2 25.40–31.75–38.10
Bolted Pressure Switch 33-1/2 850.90 66-1/2 1689.10 19-1/2 495.30 28 711.20 60 1524.0 30-5/8 777.88 None
Main Fusible Switch with (2) 1/2–3/4–1, (2) 12.70–19.05–25.40
Pull Box (4) 2 2-1/2–3– (4) 50.80–63.50–
400 Ampere 20 508.00 61 1549.40 11-3/4 298.45 12 304.80 65 1651.00 44 1117.60 3-1/2– 76.20–88.90–101.60

(2) 1/2–3/4–1, (2) 12.70–19.05–25.40


(4) 2 2-1/2–3– (4) 50.80–63.50–
600 and 800 Ampere 20 508.00 61 1549.40 11-3/4 298.45 12 304.80 65 1651.00 44 1117.60 3-1/2–4 76.20–88.90–101.60
(1-Phase)
(2) 1/2–3/4–1, (2) 12.70–19.05–25.40
(4) 2 2-1/2–3– (4) 50.80–63.50–
600 and 800 Ampere 25 635.00 61 1549.40 11-3/4 298.45 12 304.80 65 1651.00 44 1117.60 3-1/2–4 76.20–88.90–101.60
(3-Phase)
(5) 3-1/2–4–5, (5) 88.90–101.60–
(1) 3/4–1–1-1/4– 127.00 (1) 19.05–
1200 Ampere 33-1/2 850.90 61-1/2 1562.10 11-7/8 301.63 16 406.40 65-1/4 1657.35 48 1219.20 1-1/2 25.40–31.75–38.10
Pull Box
400 Ampere 16-3/8 415.93 44-7/8 1139.83 7-7/8 200.03 8 203.20 45-3/4 1162.05 28-5/8 727.08 (2) 4 101.60
800 Ampere 24-3/8 619.13 46-7/8 1190.63 11-7/8 301.63 12 304.80 47-3/4 1212.85 32-1/4 819.15 (3) 4 101.60
1200 Ampere 32-1/2 825.50 56-7/8 1444.63 12 304.80 17-3/4 450.85 57-3/4 1466.85 42-1/4 1073.15 (4) 5 127.00

CAT.71.01.T.E
Cutler-Hammer Low-Voltage Distribution Equipment F3-11
January 1999 Meter Centers
Dimensions and Knockouts

Modular Metering Stacks


1MM, 3MM, 125A

9.000 9.000
(228.60) (228.60)
Typ. Typ.

2 3 4 5 6
High High High High High
41.625 41.625 48.250 57.250 66.250
(1057.23) (1057.23) (1225.55) (1454.15) (1682.75)
Plate
Plate Plate Plate Plate
1.000 (25.40),
1.250 (31.75),
1.500 (38.10),
2.000 (50.80),
2.500 (63.50)

F
1.000 (25.40), 1.250 (31.75), 1.500 (38.10),
1.000 (25.40), 1.000 (25.40), 1.000 (25.40), 1.000 (25.40), 2.000 (50.80), 2.500 (63.50)
1.250 (31.75), 1.250 (31.75), 1.250 (31.75), 1.250 (31.75),
1.500 (38.10), 1.500 (38.10), 1.500 (38.10), 1.500 (38.10), 7.250
2.000 (50.80), 2.000 (50.80), 2.000 (50.80), 2.000 (50.80), (184.15)
2.500 (63.50) 2.500 (63.50) 2.500 (63.50) 2.500 (63.50)
12.250
(311.15)

1MM, 3MM, 200A

12.125
(307.98)
TYP

2 High 3 High 4 High


52.375 52.375 60.875
(1330.33) (1330.33) (1546.23)

1.250 (31.75), 1.500 (38.10),


2.000 (50.80)
Plate Plate Plate
7.250
(184.15)

13.500
(342.90)

CAT.71.01.T.E
F3-12 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

Dimensions and Knockouts

Modular Metering Stacks, Continued


35MM and 37MM

14.000
(355.60)
Typ.
25.375 52.625 52.625 66.625
(644.53) (1336.68) (1336.68) (1692.28)

Plate

F Plate Plate Plate

Plate

18.250
(463.55)

35SS and 37SS

21.375
(542.93)
12.000 9.563
(304.80) 0.406 Dia. (242.90)
(10.31)
4-Holes

21.375
21.375 (542.93)
(542.93)
12.000 9.563
12.000 9.500 (242.90) 19.500
(304.80) (495.30)
(304.80) (241.30)

6.500 6.500 6.500


(165.10) (165.10) (165.10)

29.375 68.875
(746.13) (1749.43)
25.000 17.750 19.500
(450.85) 19.500
(635.00) (495.30) (495.30)
Centerline
of Wall 62.438
13.500 Mounting 47.375 43.000 (1585.93)
(342.90) Screws (1203.33) (1092.20)
31.500
(800.10) 31.500
(800.10)
KO 1.500 (38.10),
2.000 (50.80), 2.500 (63.50)

Wire Seal Slot and Sealing Screw

Ribbon Seal or Barrel Lock Hasp

Bottom (Typ.)
8.750 13.563 3 KOs 1.500 (38.10),
(222.25) (344.50) 2.000 (50.80), 2.500 (63.50)
Inside

CAT.71.01.T.E
Cutler-Hammer Low-Voltage Distribution Equipment F3-13
January 1999 Meter Centers
Dimensions and Knockouts

1MP Meter Packs


125A Maximum Tenant Breaker

24.125
Mounting for 2.00 (50.80), 2.500 (57.15) (612.78)
3.000 (76.20) Conduit Hubs 36.125
11.625 (917.58)
(295.28) Ground
Lug
7.500 Ground
(190.50) Lug

9.000
53.875 (228.60) 47.250
(1368.43) (1200.15) Neutral
Lug
48.250 41.625
Neutral (1057.28) 9.000
28.500 (1225.56)
39.125 Lug (228.60)
(993.78) (723.90) 35.750 35.750
(908.05) (908.05)
Omit for Omit for 5 Meter

L of Wall Mtg. Brkt.


L of Wall Mtg. Brkt.

3 Meter
2 KOs for 1.000 (24.50),
2 KOs for 1.240 (31.75), 1.500 (38.10),
1.000 (24.50), 2.000 (50.80) 2.500 (63.50)
4 KOs for 1.000 (25.40), 1.250 (31.75), Conduit
1.250 (31.75), 1.500 (38.10), 2.250 (57.15)
1.500 (38.10) 2.000 (50.80)

C
C

Conduit Back 2.500 (63.50) 2.875 (73.03)


and Side Conduit
KO for 1.500 (38.10), KO for 1.000 (25.40),
2.000 (50.80), 1.250 (31.75), 2 KOs for 2.500 (63.50), 12 KOs for 1.000 (25.40),
15.000 7 KOs for 1.000 (25.40), 27.000
2.500 (63.50), 1.500 (38.10) 3.000 (76.20), 3.500 (88.90) 1.500 (38.10) Conduit
(381.00) 1.500 (38.10) Conduit (685.80)
3.000 (76.20) Conduit Conduit 4.000 (101.60) Conduit

7.000 7.000
F
6.000 (152.40) (177.80) (177.80)
3.625 (92.08)

KO for .500 (12.70) 2.000 2 KOs for 2.500 (63.50), KO for .500 (12.70) Conduit 2.000
Conduit (50.80) 3.000 (76.20), 3.500 (88.90), (50.80)
4.000 (101.60) Conduit
125A Maximum Tenant Breaker

200A Maximum Tenant Breaker

25.500
(647.70)

38.875
(987.43)

Neutral
12.125 Lug
(307.98)
58.000 Ground
70.125 (1473.20) Lug
25.500 (1781.18)
(647.70) 52.375
64.625 Neutral (1330.33) 12.125
Neutral Lug (1641.48) Lug (307.98)
38.000
(965.20) Ground
Ground Lug Lug 35.750
35.750 (908.05)
32.125
(908.05) Omit for
(815.98)
L of Wall Mtg. Brkt.

3 Meter Omit for


CL of Wall Mtg. Brkt.

L of Wall Mtg. Brkt.

12.125 5 Meter
43.625 (307.98)
(1108.08) 4 KOs for 8 KOs for 1.000 (25.40),
1.000 (25.40), 1.250 (31.75), 1.500 (38.10),
13.750 1.250 (31.75), 2.000 (50.80) Conduit
(349.25) 1.500 (38.10),
C

2.000 (50.80)
C

Conduit 2.500 (63.50)


4 KOs for 1.250 (31.75),
2 KOs for 2.500 (63.50), 15.000 6 KOs for 1.250 (31.75),
1.500 (38.10), 15.000 27.000
(381.00) 4 KOs for 1.250 (31.75), 1.500 (38.10),
3.000 (76.20), 3.500 (88.90), 2.000 (50.80) Conduit 2 KOs for 2.500 (63.50), 3.000 (76.20), (381.00) (685.80)
4.000 (101.60) Conduit 3.500 (88.90), 4.000 (101.60) Conduit 1.500 (38.10), 2.000 (50.80) Conduit 2.000 (50.80) Conduit
7.000
7.000 7.000
3.625 (92.08) (177.80)
(177.80) (177.80)
3.625 (92.08) 3.625 (92.08)
KO for .500 (12.70) Conduit 2.250
KO for .500 (12.70) KO for .500 (12.70) Conduit 2.250
(57.15) 2.250
Conduit) (57.15) 2 KOs for 2.500 (63.50), 3.000 (75.20) (57.15)
3.500 (88.90), 4.000 (101.60) Conduit

200A Maximum Tenant Breaker

Note: 3- and 4-position meter packs with 125A


positions and 3 – 6-position meter packs with
200A positions allow straight-in wiring for
either top or bottom cable entry. All others can
be fed from the top, but require looping of the
service cables.

CAT.71.01.T.E
F3-14 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

Dimensions

Typical Lineups
Minimum and maximum height of
1-phase and 3-phase meter sockets
above typical ground level.

1MM/3MM 1MM/3MM 35MM/37MM 35MM/37MM 35MM/37MM 37MM 35MM/37MM


200A 125A 225A Max. 225A Max. 225A Max. 400A
13.500 12.250 19.250 18.250 18.250 18.250 18.250
(342.90) (311.15) (488.96) (463.56) (463.56) (463.56) (463.56)

Wall Hanger Screws


C
L

30.625 35MM/37MM

F 34.250
(869.95) (777.88)

Main Device
35MM/37MM 35MM/37MM 35MM/37MM 35MM/400A
3MM/200A 3MM/125A
Typical Height 31.875 26.000 30.000 30.000 44.000 31.000
Above Ground (809.63) (660.40) (762.00) (762.00) (1117.60) (787.40)
or Floor Level
13.375 17.000
(339.73) 68.250 71.000 (431.80) 72.000 58.000 58.000 58.000 44.000
(1733.56) (1803.40) (1828.80) (1473.20) (1473.20) (1473.20) (1117.60)

CAT.71.01.T.E
Cutler-Hammer Low-Voltage Distribution Equipment F3-15
January 1999 Meter Centers
Typical Specifications

Typical Specifications Wiring/Terminations B. Fusible switches shall be fur-


A. [Mechanical-type terminals] nished with class L fuse clips.
Ratings [Crimp-type termination provi- Switch contact interrupting
A. The assembly shall be rated to sions] shall be provided for all capacity shall be 12 times the con-
withstand mechanical forces line terminations suitable for cop- tinuous rating of the switch.
exerted during short circuit con- per or aluminum cable and rated C. Fuse access door shall be mech-
ditions when connected directly at 75 degrees C. anically interlocked with the
to a power source having avail- operating handle and shall have
B. Lugs shall be provided in the
able fault current [22,000] provisions for padlocking the
incoming line section for connec-
[42,000] [65,000] [100,000] switch in the open position.
tion of the main grounding
amperes symmetrical at rated
conductor. D. The switch shall utilize a stored
voltage.
Main Circuit Protective Devices energy deadfront operating
Construction mechanism compressed and re-
A. Main protective devices shall be
A. The entire assembly shall be front leased by the operating handle, to
[molded case circuit breakers]
accessible and shall include provide quick positive switching
[bolted pressure switches] [quick-
[main lugs] [a main disconnect action, independent of the operat-
make/quick break fusible
device]. ing handle.
switches].
B. Tenant disconnects shall be E. Switches shall be manually
Molded Case Circuit Breakers
wired for cold sequence and shall operated.
be molded case circuit breakers. A. [Main] [Feeder] [All] protective
devices shall be molded case Quick-Make/Quick-Break Fusible
C. The meter sockets shall be [ring-]
[ringless-] type rated [125 am-
circuit breakers with inverse time Switches F
and instantaneous tripping A. Fusible switches 30 ampere
peres] [200 amperes] [as shown characteristics. through 1200 ampere frames
on the plans] and a bypass [shall shall be furnished with 300V class
be] [shall not be] required. If B. Circuit breakers shall be operated
by a toggle-type handle and shall T-type fuse clips unless
required, the bypass shall be a otherwise scheduled.
[slider-] [horn-] [lever-] [discon- have a quick-make/quick-break
over-center switching mecha- B. Switches shall incorporate safety
nect block-] type. The meter
nism that is mechanically trip- cover interlocks to prevent open-
sockets and associated branch
free. Automatic tripping of the ing the cover with the switch in
protective device positions shall
breaker shall be clearly indicated the ON position.
be completely prewired and
shipped ready for installation by the handle position. Contacts C. Provide defeater for authorized
of the meters and tenant main shall be nonwelding silver alloy personnel.
breakers. Meter sockets shall and arc extension shall be accom-
D. Handles shall have provisions for
include covers with sealing plished by means of DE-ION arc
padlocking and shall clearly indi-
positions. chutes.
cate the ON or OFF position.
Bus C. Circuit breakers shall have a min-
E. Front cover doors shall be pad-
imum symmetrical interrupting
A. All bus bars shall be tin-plated lockable in the closed position.
capacity as indicated on the
aluminum. Main horizontal bus F. Main protective devices shall be
drawings.
bars shall be mounted with all quick-make/quick-break fusible
three phases arranged in the D. Circuit breakers [250-] [400-]
switches as manufactured by
same vertical plane. Bus sizing [600-] [1200-] ampere frame and
Cutler-Hammer.
shall be based on UL standard below shall be manufactured by
Cutler-Hammer with thermal- Tenant Utility Metering
temperature rise criteria for
multiple metering equipment. magnetic or electronic trip units A. For EUSERC serviced areas,
having inverse time-current meter centers shall incorporate
B. Provide a full capacity neutral bus metering sections with tenant
characteristics.
where a neutral bus is indicated feeder circuits using ring-type
on the drawings. E. Circuit breakers shall be UL listed
for series application. meter sockets rated [125] [200]
C. All hardware used for aluminum amperes to meet local utility and/
bus bar connections shall be Bolted Pressure Switches or customer requirements.
high-tensile strength, zinc-plated. A. Main protective devices shall be
B. The self-contained meter sockets
Provide Belleville-type spring bolted pressure contact type and
shall include a test bypass/dis-
washers for all bus joints. shall be UL listed.
connect block per EUSERC
requirements,
– OR –

CAT.71.01.T.E
F3-16 Low-Voltage Distribution Equipment Cutler-Hammer
Meter Centers January 1999

Typical Specifications

A. For non-EUSERC serviced areas,


meter centers shall incorporate
metering sections with tenant
feeder circuits using [ring-] [ring-
less-] type meter sockets rated
[125-] [200] [320] amperes to
meet local utility or customer
requirements. Provide meter
sockets with individual covers
having sealing provisions.
B. Meter sockets shall have manual
bypass and optional internal
barriers.
Enclosures
A. NEMA 1 Enclosure
– OR –
A. Outdoor NEMA 3R Surface-
Mounted Enclosure
Finish

F A. Boxes and trims shall be bonder-


ized and finished with ANSI 61
light gray enamel.
Further Information
Product Guide – PG.32.01.T.E
Modular Metering System for
Residential and Commercial
Applications
Brochure – B.32.A.01.S.E
Multiple Metering Products for
Residential and Commercial
Applications

For a complete product specifica-


tion in CSI format, see Cutler-
Hammer Product Specification
Guide, section 16432.

CAT.71.01.T.E