You are on page 1of 15

RENEWABLE ENERGY

SERIES 4000
FLOODED DEEP CYCLE BATTERY S2 L16-HC

Specifications

Weight 57.5 kg 127 lbs

Length 31.8 cm 12.5"

Width 18.1 cm 7.13"

Height Inc. Term. 43.2 cm 17"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container High Density Polypropylene


Series 4000 Warranty 3 Years
Cover High Density Polypropylene
Volts 2 BCI L16
Handles Rope / Plastic Handle
Cells 1 Plates/Cell 49

Terminal Type LT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Cables Optional: 19" 4/0 interconnect cable

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 155 A

Maximum Charge Current (String) 255 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 3119
Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 3898

Reserve Capacity (RC @ 25A) 2584 Minutes

Reserve Capacity (RC @ 75A) 679 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 1535 AH 15.35 A

@ 72 Hour Rate 1495 AH 20.77 A

@ 50 Hour Rate 1442 AH 28.84 A

@ 20 Hour Rate 1335 AH 66.75 A

@ 15 Hour Rate 1255 AH 83.66 A

@ 10 Hour Rate 1202 AH 120.15 A

@ 8 Hour Rate 1148 AH 143.51 A

@ 5 Hour Rate 1068 AH 213.60 A

@ 1 Hour Rate 627 AH 627.45 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.
Rev.#2 | May 2019
FLOODED DEEP CYCLE BATTERY S2 L16-SC

Specifications

Weight 59 kg 130 lbs

Length 31.8 cm 12.5"

Width 18.1 cm 7.13"

Height Inc. Term. 43.2 cm 17"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container High Density Polypropylene


Series 4000 Warranty 3 Years
Cover High Density Polypropylene
Volts 2 BCI L16
Handles Rope / Plastic Handle
Cells 1 Plates/Cell 53

Terminal Type LT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Cables Optional: 19" 4/0 interconnect cable

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 175 A

Maximum Charge Current (String) 290 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 3378
Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 4223

Reserve Capacity (RC @ 25A) 2909 Minutes

Reserve Capacity (RC @ 75A) 764 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 1728 AH 17.28 A

@ 72 Hour Rate 1683 AH 23.38 A

@ 50 Hour Rate 1623 AH 32.46 A

@ 20 Hour Rate 1503 AH 75.15 A

@ 15 Hour Rate 1413 AH 94.19 A

@ 10 Hour Rate 1353 AH 135.27 A

@ 8 Hour Rate 1293 AH 161.57 A

@ 5 Hour Rate 1202 AH 240.48 A

@ 1 Hour Rate 706 AH 706.41 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.
Rev.#2 | May 2019
FLOODED DEEP CYCLE BATTERY S2 L16

Specifications

Weight 54.5 kg 120 lbs

Length 31.8 cm 12.5"

Width 18.1 cm 7.13"

Height Inc. Term. 43.2 cm 17"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container High Density Polypropylene


Series 4000 Warranty 3 Years
Cover Polypropylene
Volts 2 BCI L16
Handles Rope / Plastic Handle
Cells 1 Plates/Cell 43

Terminal Type LT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Cables Optional: 19" 4/0 interconnect cable

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 135 A

Maximum Charge Current (String) 225 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 2729
Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 3411

Reserve Capacity (RC @ 25A) 2263 Minutes

Reserve Capacity (RC @ 75A) 594 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 1344 AH 13.44 A

@ 72 Hour Rate 1309 AH 18.18 A

@ 50 Hour Rate 1263 AH 25.25 A

@ 20 Hour Rate 1169 AH 58.45 A

@ 15 Hour Rate 1099 AH 73.26 A

@ 10 Hour Rate 1052 AH 105.21 A

@ 8 Hour Rate 1005 AH 125.67 A

@ 5 Hour Rate 935 AH 187.04 A

@ 1 Hour Rate 549 AH 549.43 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.
Rev.#2 | May 2019
FLOODED DEEP CYCLE BATTERY S6 145

Specifications

Weight 32 kg 70.5 lbs

Length 25.9 cm 10.19"

Width 18.1 cm 7.13"

Height Inc. Term. 29 cm 11.4"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 44 mm 1.75"

Container Polypropylene
Series 4000 Warranty 3 Years
Cover Polypropylene
Volts 6 BCI GC2H
Handles Top Molded Strap Brackets
Cells 3 Plates/Cell 17

Terminal Type DT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 30 A

Maximum Charge Current (String) 50 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 710 Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 888

Reserve Capacity (RC @ 25A) 484 Minutes

Reserve Capacity (RC @ 75A) 127 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 320 AH 3.2 A

@ 72 Hour Rate 315 AH 4.38 A

@ 50 Hour Rate 298 AH 5.95 A

@ 20 Hour Rate 250 AH 12.5 A

@ 15 Hour Rate 238 AH 15.83 A

@ 10 Hour Rate 220 AH 22 A

@ 8 Hour Rate 215 AH 26.88 A

@ 5 Hour Rate 198 AH 39.5 A

@ 1 Hour Rate 100 AH 100 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250. Rev.#1 | March 2019
FLOODED DEEP CYCLE BATTERY S6 GC2-HC

Specifications

Weight 31.5 kg 69.5 lbs

Length 25.9 cm 10.19"

Width 18.1 cm 7.13"

Height Inc. Term. 27.9 cm 11"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container Polypropylene
Series 4000 Warranty 3 Years
Cover Polypropylene
Volts 6 BCI GC2
Handles Top Molded Strap Brackets
Cells 3 Plates/Cell 19

Terminal Type DT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 30 A

Maximum Charge Current (String) 45 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 625 Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 781

Reserve Capacity (RC @ 25A) 445 Minutes

Reserve Capacity (RC @ 75A) 117 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 294 AH 2.94 A

@ 72 Hour Rate 290 AH 4.03 A

@ 50 Hour Rate 274 AH 5.47 A

@ 20 Hour Rate 230 AH 11.5 A

@ 15 Hour Rate 219 AH 14.57 A

@ 10 Hour Rate 202 AH 20.24 A

@ 8 Hour Rate 198 AH 24.73 A

@ 5 Hour Rate 182 AH 36.34 A

@ 1 Hour Rate 92 AH 92 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250. Rev.#1 | March 2019
FLOODED DEEP CYCLE BATTERY S6 GC2

Specifications

Weight 28 kg 61.5 lbs

Length 25.9 cm 10.19"

Width 18.1 cm 7.13"

Height Inc. Term. 27.9 cm 11"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container Polypropylene
Series 4000 Warranty 3 Years
Cover Polypropylene
Volts 6 BCI GC2
Handles Top Molded Strap Brackets
Cells 3 Plates/Cell 17

Terminal Type DT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 25 A

Maximum Charge Current (String) 40 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 547 Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 684

Reserve Capacity (RC @ 25A) 406 Minutes

Reserve Capacity (RC @ 75A) 107 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 269 AH 2.69 A

@ 72 Hour Rate 265 AH 3.68 A

@ 50 Hour Rate 250 AH 5A

@ 20 Hour Rate 210 AH 10.5 A

@ 15 Hour Rate 200 AH 13.3 A

@ 10 Hour Rate 185 AH 18.48 A

@ 8 Hour Rate 181 AH 22.58 A

@ 5 Hour Rate 166 AH 33.18 A

@ 1 Hour Rate 84 AH 84 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250. Rev.#1 | March 2019
FLOODED DEEP CYCLE BATTERY S6 L16-HC

Specifications

Weight 55.5 kg 122.5 lbs

Length 31.8 cm 12.5"

Width 18.1 cm 7.13"

Height Inc.
42.55 cm 16.75"
Term.

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container High Density Polypropylene


Series 4000 Warranty 3 Years
Cover High Density Polypropylene
Volts 6 BCI L16
Handles Rope / Plastic Handle
Cells 3 Plates/Cell 17

Terminal Type LT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Cables Optional: 19" 4/0 interconnect cable

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 50 A

Maximum Charge Current (String) 85 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 1040
Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 1299

Reserve Capacity (RC @ 25A) 861 Minutes

Reserve Capacity (RC @ 75A) 226 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 512 AH 5.12 A

@ 72 Hour Rate 498 AH 6.92 A

@ 50 Hour Rate 481 AH 9.61 A

@ 20 Hour Rate 445 AH 22.25 A

@ 15 Hour Rate 418 AH 27.89 A

@ 10 Hour Rate 401 AH 40.05 A

@ 8 Hour Rate 383 AH 47.84 A

@ 5 Hour Rate 356 AH 71.20 A

@ 1 Hour Rate 209 AH 209.15 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.
Rev.#2 | May 2019
FLOODED DEEP CYCLE BATTERY S6 L16-SC

Specifications

Weight 56.5 kg 124.5 lbs

Length 31.8 cm 12.5"

Width 18.1 cm 7.13"

Height Inc.
42.55 cm 16.75"
Term.

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container High Density Polypropylene


Series 4000 Warranty 3 Years
Cover High Density Polypropylene
Volts 6 BCI L16
Handles Rope / Plastic Handle
Cells 3 Plates/Cell 18

Terminal Type LT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Cables Optional: 19" 4/0 interconnect cable

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 55 A

Maximum Charge Current (String) 95 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 1169
Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 1462

Reserve Capacity (RC @ 25A) 943 Minutes

Reserve Capacity (RC @ 75A) 248 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 560 AH 5.60 A

@ 72 Hour Rate 545 AH 7.58 A

@ 50 Hour Rate 526 AH 10.52 A

@ 20 Hour Rate 487 AH 24.35 A

@ 15 Hour Rate 458 AH 30.52 A

@ 10 Hour Rate 438 AH 43.83 A

@ 8 Hour Rate 419 AH 52.35 A

@ 5 Hour Rate 328 AH 65.52 A

@ 1 Hour Rate 229 AH 228.89 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.
Rev.#2 | May 2019
FLOODED DEEP CYCLE BATTERY S6 L16

Specifications

Weight 51 kg 112.5 lbs

Length 31.8 cm 12.5"

Width 18.1 cm 7.13"

Height Inc.
42.55 cm 16.75"
Term.

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 57 mm 2.25"

Container High Density Polypropylene


Series 4000 Warranty 3 Years
Cover High Density Polypropylene
Volts 6 BCI L16
Handles Rope / Plastic Handle
Cells 3 Plates/Cell 15

Terminal Type LT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Cables Optional: 19" 4/0 interconnect cable

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 45 A

Maximum Charge Current (String) 75 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 910
Voltage vs. Depth of Discharge
Marine Crank Amps (MCA) 32°F / 0°C 1137

Reserve Capacity (RC @ 25A) 755 Minutes

Reserve Capacity (RC @ 75A) 198 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 449 AH 4.49 A

@ 72 Hour Rate 437 AH 6.07 A

@ 50 Hour Rate 421 AH 8.42 A

@ 20 Hour Rate 390 AH 19.50 A

@ 15 Hour Rate 367 AH 24.44 A

@ 10 Hour Rate 351 AH 35.10 A

@ 8 Hour Rate 335 AH 41.93 A

@ 5 Hour Rate 312 AH 62.40 A

@ 1 Hour Rate 183 AH 183.30 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.
Rev.#2 | May 2019
FLOODED DEEP CYCLE BATTERY S12 185

Specifications

Weight 61 kg 134.5 lbs

Length 39.1 cm 15.38"

Width 17.8 cm 7"

Height Inc. Term. 36.5 cm 14.38"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 51 mm 2"

Container Polypropylene
Series 4000 Warranty 3 Years
Cover Polypropylene
Volts 12 BCI 921
Handles Rope / Plastic Handle
Cells 6 Plates/Cell 9

Terminal Type DT Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Cables Optional: 19" 4/0 interconnect cable

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 25 A

Maximum Charge Current (String) 40 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity Voltage vs. Depth of Discharge


Cold Crank Amps (CCA) 0°F / -17°C 648

Marine Crank Amps (MCA) 32°F / 0°C 810

Reserve Capacity (RC @ 25A) 406 Minutes

Reserve Capacity (RC @ 75A) 107 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 279 AH 2.79 A

@ 72 Hour Rate 265 AH 3.68 A

@ 50 Hour Rate 250 AH 5A

@ 20 Hour Rate 210 AH 10.5 A

@ 15 Hour Rate 200 AH 13.3 A

@ 10 Hour Rate 185 AH 18.48 A

@ 8 Hour Rate 181 AH 22.58 A

@ 5 Hour Rate 166 AH 33.18 A

@ 1 Hour Rate 84 AH 84 A
Rev.#1 | March 2019
Amphere hour capacity ratings based on specific gravity of 1.280.
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.
FLOODED DEEP CYCLE BATTERY S12 24

Specifications

Weight 21.5 kg 47.5 lbs

Length 27.9 cm 11"

Width 17.1 cm 6.75"

Height Inc. Term. 23.8 cm 9.38"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Container ABS

Cover ABS
Series 4000 Warranty 3 Years
Handles Plastic Strap
Volts 12 BCI Grp 24

Cells 6 Cycle Life vs. Depth of Discharge

Terminal Type DT

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 10 A

Maximum Charge Current (String) 20 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity Voltage vs. Depth of Discharge


Cold Crank Amps (CCA) 0°F / -17°C 550

Marine Crank Amps (MCA) 32°F / 0°C 690

Reserve Capacity (RC @ 25A) 150 Minutes

Reserve Capacity (RC @ 75A) 43 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 106 AH 1.06 A

@ 20 Hour Rate 85 AH 4.25 A

@ 15 Hour Rate 80 AH 5.33 A

@ 10 Hour Rate 72 AH 7.23 A

@ 8 Hour Rate 71 AH 8.82 A

@ 5 Hour Rate 69 AH 13.8 A

@ 1 Hour Rate 31 AH 30.6 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Rev.#1 | March 2019


FLOODED DEEP CYCLE BATTERY S12 27

Specifications

Weight 24.5 kg 54 lbs

Length 32.1 cm 12.63"

Width 17.1 cm 6.75"

Height Inc. Term. 23.8 cm 9.38"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Container ABS

Cover ABS
Series 4000 Warranty 3 Years
Handles Plastic Strap
Volts 12 BCI Grp 27

Cells 6 Cycle Life vs. Depth of Discharge

Terminal Type DT

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 15 A

Maximum Charge Current (String) 25 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity Voltage vs. Depth of Discharge


Cold Crank Amps (CCA) 0°F / -17°C 660

Marine Crank Amps (MCA) 32°F / 0°C 825

Reserve Capacity (RC @ 25A) 185 Minutes

Reserve Capacity (RC @ 75A) 53 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 140 AH 1.4 A

@ 20 Hour Rate 105 AH 5.25 A

@ 15 Hour Rate 99 AH 6.58 A

@ 10 Hour Rate 89 AH 8.93 A

@ 8 Hour Rate 87 AH 10.89 A

@ 5 Hour Rate 85 AH 17.01 A

@ 1 Hour Rate 38 AH 37.8 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Rev.#1 | March 2019


FLOODED DEEP CYCLE BATTERY S12 31

Specifications

Weight 29.5 kg 65 lbs

Length 33 cm 13"

Width 17.1 cm 6.75"

Height Inc. Term. 24.1 cm 9.5"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Container Polypropylene

Cover Polypropylene
Series 4000 Warranty 3 Years
Handles Integrated Top Mount
Volts 12 BCI

Cells 6 Plates/Cell 11 Cycle Life vs. Depth of Discharge

Terminal Type DT

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)

Float Voltage Range 2.25 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 15 A

Maximum Charge Current (String) 25 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity Voltage vs. Depth of Discharge


Cold Crank Amps (CCA) 0°F / -17°C 670

Marine Crank Amps (MCA) 32°F / 0°C 906

Reserve Capacity (RC @ 25A) 216 Minutes

Reserve Capacity (RC @ 75A) 64 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 173 AH 1.73 A

@ 20 Hour Rate 130 AH 6.5 A

@ 10 Hour Rate 111 AH 11.05 A

@ 5 Hour Rate 98 AH 19.5 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Rev.#1 | March 2019


FLOODED DEEP CYCLE BATTERY S12 GC

Specifications

Weight 37.5 kg 82.5 lbs

Length 33.3 cm 13.13"

Width 18.2 cm 7.17"

Height Inc. Term. 27.4 cm 10.8"

Product measurements & weights are calculated based on sample data. Individual specifications
are subject to vary due to the manufacturing process, battery components & electrolyte levels.

Electrolyte Reserve 38 mm 1.5"

Container Polypropylene
Series 4000 Warranty 3 Years
Cover Polypropylene
Volts 12 BCI GC12
Handles Top Molded Strap Brackets
Cells 6 Plates/Cell 11

Terminal Type UTL Cycle Life vs. Depth of Discharge

Included Hardware S/S Hex Cap Screw, Nut, Lock & Flat Washer

Size & Thread 5/16"-18 x 1-1/2"

Charge
Charge Voltage Range 14.7-15 V/cell @ 25°C (77°F)

Recommended Charge Current Capacity (String) 15 A

Maximum Charge Current (String) 25 A

5%-10% per month at 25°C


Self-Discharge Rate
(77°F)

Capacity
Cold Crank Amps (CCA) 0°F / -17°C 563

Marine Crank Amps (MCA) 32°F / 0°C 703 Voltage vs. Depth of Discharge
Reserve Capacity (RC @ 25A) 284 Minutes

Reserve Capacity (RC @ 75A) 79 Minutes

Hour Rate Capacity / AMP Hour Current / AMPs


@ 100 Hour Rate 206 AH 2.06 A

@ 72 Hour Rate 195 AH 2.71 A

@ 50 Hour Rate 184 AH 3.69 A

@ 20 Hour Rate 155 AH 7.75 A

@ 15 Hour Rate 147 AH 9.82 A

@ 10 Hour Rate 136 AH 13.64 A

@ 8 Hour Rate 133 AH 16.66 A

@ 5 Hour Rate 122 AH 24.49 A

@ 1 Hour Rate 62 AH 62 A

Amphere hour capacity ratings based on specific gravity of 1.280.


Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Rev.#1 | March 2019

You might also like