CHECKLIST FOR PRECAST BUILDING

PROJECT : GHMC 2BHK DATE OF INSPECTION


CONTRACTOR : INDRAJITH MEHATHA
LOCATION : DUNDIGAL
BLOCK NO : 6

PARTICULARS YES

PRE PRECAST
MOULD
Dimensions of the mould as per area YES
profile of the mould done with the iron table YES
Is the mould cleanliness is done YES
Is the mould cleanliness is done YES
REINFORCEMENT
Different sizes of bars are used in slab(12mm,10mm,8mm) YES
Different sizes of bars are used in wall mm, 16mm) YES
spacing of the bars in slab(150mm,200mm) YES
spacing of the bars in wall(150mm,200mm) YES
types of bars(HYSD) are used or not YES
Is this pre tension in slab
is this post tension in slab YES
CONCRETING (for wall M25)
concrete compaction is done or not (for slab M25) YES
proper surface finishes for walls are done YES

DURING PRECAST
Proper erection of precast wall YES
whether the walls are correctly placed or not YES
proper erection of precast slab YES
whether the slabs are correctly placed or not YES
proper brickwork is done or not(SL,LL,RL) YES
check the proper plastering YES
internal plastering of brickwork(12mm) (1:4) YES
external plastering of brickwork(15mm) (1:6) YES
check the proper flooring is done or not
Is the flooring slope is proper or not
joints are properly fixed or not YES
baker rods used in between slab and wall or not YES

POST PRECAST
Is the building has the good appearance or not YES
check the windows are properly fixed or not YES
check the doors are properly fixed or not YES
proper ventilation is done or not YES
sanitary is properly fixed or not YES
Is the grouting is done or not YES
plumbing is properly done or not YES
painting is done or not
INSPECTION : 6/24/2019

NO REMARK

NO

NO work is going on
NO work is going on
wc is not yet fixed

still work is going on


NO