1. Name of the Manufacturer :
2. Normal continuous rating :
3. Normal ratio of transformation :
4. PHASE CONNECTIONS
a) HV Winding :
b) LV Winding :
c) Vector group reference number and :
symbol
5. MAXIMUM TEMPERATURE RISE
a) Of oil by Thermometer :
b) Of Winding by resistance :
c) By Hot spot temperature Indicator :
d) Ambient Temperature adopted :
6. Limit for Hot spot temperature for which :
the transformer is designed
7. Temperature gradient between windings :
and oil
8. Voltage to earth for which the star point :
will be insulated
9. Type of cooling :
10. MAXIMUM FLUX DENSITY IN IRON AT
NORMAL VOLTAGE, FREQUENCY AND
RATIO
a) Core :
b) Yoke :
11. MAXIMUM CURRENT DENSITY IN
WINDING AT CMR
a) HV Winding Amps/sq.cm. :
b) LV Winding amps / sq.cm :
Volume-III : Section-II 2
Guaranteed Technical Particulars
S.N Description
o
12. Magnetizing Current (HV) at normal :
voltage and ratio (Amps)
13. Power Factor of Magnetizing current at :
normal voltage and frequency
14. a) Guaranteed no load loss at normal :
ratio rated voltage and frequency
(Max.)
b) Guaranteed load loss at normal ratio, :
rated output, rated voltage, rated
frequency and 750C average winding
temperature including auxiliary losses,
if any (Max.)
15. Guaranteed total losses at}At Normal At :
lowest At highest rated output, tap
rated voltage, rated frequency and 750C
average winding temperature including
auxiliary losses if any (Max.)
16. Total losses at rated output, rated :
voltage, rated frequency and maximum
attainable temperature at site including
auxiliary losses if any. (Max.)
18. Efficiencies at normal ratio, rated voltage,
rated frequency and 750C average
winding temperature for the outputs of.
a) Full load :
b) 3/4 Full load :
c) 1/2 Full load :
d) 1/4 Full load :
19. Resistance per phase of (at normal tap)
a) HV Winding (Ohms) :
b) LV Winding (Ohms) :
20. Reactance per phase of (at normal tap)
a) HV Winding (Ohms) :
b) LV Winding (Ohms) :
Volume-III : Section-II 3
Guaranteed Technical Particulars
S.N Description
o
21. Resistance voltage drop at 750C average :
winding temperature expressed as
percent of rated voltage.
22. Reactance voltage drop expressed as :
percent of rated voltage
23. Impedance voltage at normal: at normal
at lowest at highest and 750C average
winding tap temperature expressed as
percent of rated voltage. (Indicate tap
nos.)
a) Between HV and LV winding :
b) Positive Sequence HV :
c) Positive Sequence LV :
24. Regulation at full load at 750C
a) Unity Power Factor :
b) 0.8 Power Factor (Lagging) :
25. Type of transformer (Core or Shell) :
26. Width of track gauge :
27. Core
a) Material of Core lamination :
b) Thickness of Core Plates :
c) Whether Core Plates are grain :
oriented cold rolled
d) Insulation of core lamination :
e) Insulation of core bolts :
f) Insulation of core bolt washers :
g) Insulation of core and plates :
h) Details of oil ducts in cores :
i) Whether in the plane and at right :
angle to the plane of winding
ii) Across the plane of laminations :
Volume-III : Section-II 4
Guaranteed Technical Particulars
S.N Description
o
28. Windings
a) Type of Winding
i) HV Winding :
ii) LV Winding :
b) Insulation of HV winding
c) Insulation of LV winding
d) Insulation between HV & LV winding
e) Power frequency High Voltage Tests
i) Test Voltage for 1 minute withstand
test on High Voltage Windings
(Induced)
ii) Test Voltage for one minute
withstand test on Low voltage
windings
iii) Test Voltage for one minute
withstand test on Neutral end of
high voltage winding
iv) Impulse test on High Voltage
Winding 1/50 full wave withstand
v) Impulse test on low voltage winding
1/50 full wave withstand
vi) Wave form for impulse test
g) Inter turn insulation HV/LV
i) Extent of extreme and turns
reinforcement
ii) Extent of end turns reinforcement
iii) Extent of turns adjacent to tapping
reinforced
iv) Test Voltage for ten seconds 50
cycles inter turn insulation test on (i)
v) Test Voltage for ten seconds 50
cycles inter turn insulation test on (ii)
Volume-III : Section-II 5
Guaranteed Technical Particulars
S.No Description
vi) Test Voltage for ten seconds 50
cycles inter turn insulation test on
(iii)
vii) Test Voltage for ten seconds 50
cycles inter turn insulation test on
main body of the winding
h) Type of Axial coil supports
i) High Voltage Winding
ii) Low Voltage winding
i) Type of radial coil supports
i) High Voltage Winding
ii) Low Voltage Winding
j) Whether HV windings are inter leaved
k) Details of special if any, made to
improve stress conditions
l) Size of cooling ducts
m) Drawings to scale indicating flow of
oil in the radial and axial ducts of each
limb and winding
29. Maximum out of balance force in winding
on short circuit at the terminals
30. Thickness of Transformer tank plate:
a) Sides mm
b) Bottom mm
c) Radiator Plate mm
31. Type and details of winding hot spot
temperature detector
32. Power requirement of heater in
conservator
33. Buchholz relay description, data, range of
settings schematic diagram etc.
Volume-III : Section-II 6
Guaranteed Technical Particulars
S.No Description
34. Bushings:
a) Type
b) Dry flash over voltage
c) Wet flash over voltage
d) Dry 60s withstand test voltage
e) Wet 60s withstand test voltage
f) Full wave withstand test voltage with
1.2/50 micro seconds wave (+) Positive
(-) Negative
g) Creepage distance in air
h) Recommended gap setting mm
i) Weight of assembled bushing (Kgs)
j) Quantity of oil (ltrs.)
35. Free space required at top for removal of
bushings (mm)
36. Total volume of conservator liters
37. Volume of conservator between the
Highest and lowest levels liters
38. Cooling system
a) Type and make of Fan motors for
forced air cooling equipment
b) Rating and speed of motors
c) Efficiency of motors at full load
d) Temperature rise of motors at full
load
e) Number of fan motors
39. Period of continuous working at full load
without fans
40. Continuous kVA rating without fans
41. Calculated time constants
a) Natural cooling
Volume-III : Section-II 7
Guaranteed Technical Particulars
S.N Description
o
42. Details of on load tap changing gear
a) Make
b) Type
c) Rating:
i) Rated voltage
ii) Rated current
iii) Step voltage
iv) Number of steps
d) Approximate overall weight
e) Approximate overall dimensions
(HxWxD)
f) Approximate overall quantity of oil –
litres
43. Weight of copper required to complete
the transformer (Kgs.)
44. Weight of steel required to complete the
transformer (Kgs.)
45. Weight of fittings and parts detached for
transport (Kgs.)
46. Weight of core and windings (Kgs)
47. Weight of complete transformer with all
fittings and oil (Kgs.)
48. Weight of complete transformer arranged
for transport of the heaviest package, if
broken down (Kgs.)
49. Weight of oil in the transformer (Kgs.)
50. Dimensions of the transformers in meters
a) Maximum height to top of bushings
b) Overall length
c) Overall breadth
d) Heaviest package for transport
Volume-III : Section-II 9
Guaranteed Technical Particulars
S.N Description
o
51. Taps
52. Fault levels for which the transformer is
designed
53. List of accessories and fittings being
provided for transformer
54. Whether the materials covered by this Bid Yes/No.
have been fully type tested and if so,
whether the copies of the type test
certificates enclosed to the bid offer.
55. Whether oil temperature indicator Yes / No
provided
56. Type and size of oil temperature
indicator and whether supervisory alarm
contacts provided
57. Type of oil level indicator and whether
supervisory alarm contact for low oil level
provided
58. Type and size of Gas operated relay and
whether supervisory alarm and trip
contacts provided and their sizes and
Nos.
59. Whether winding temperature indicator
with supervisory alarm indicator and trip
contacts provided and their sizes and
Nos.
60. Ratio and type of C.T. used for winding
temperature indicator
61. Type and size of Thermostat used
62. No. of Breathers provided
S.N Description
o
65. Valve sizes and Numbers required/fitted
66. Size of Rail gauge for installation in yard
67. Wheel base
68. a. Type and make of pressure relief
device
b. No. of each type of devices per
transformer unit (Nos.)
c. Minimum pressure at which the device
operates (kPa)
69. Performance Guarantee
S. No Description Unit
S. No Description Unit
Whether contacts silver are plated
18.
and thickness of plating
Whether breaker designed to
19. close and latch on making current
release ?
Whether trip free or fixed trip
20.
mechanically and electrically
21. Type of closing
22. Type of tripping
23. Normal voltage of :
a) Closing/tripping mechanism
b) Spring charging motor
Allowable variation of voltage for
24.
above
Power required at normal voltage
25.
for
a) Trip coil
b) Closing coil
c) Spring charging motor
Weight of circuit breaker with arc
26.
extinguishing medium
27. Opening time in cycles
28. Making time in cycles
29. Opening time at :
a) 10% of rated short circuit
current
b) 50% of rated short circuit
current
c) 100% of rated short circuit
current
Heat dissipation at normal current
30.
(KW)
Whether 12 Nos. adjustable
(either in ‘NO’ or ‘NC’) auxiliary
31.
contacts over and above those
required for been provided or not.
Current carrying capacity of
32.
auxiliary switches.
No. of breaker operations
33. necessary (before inspection and
maintenance of :
a) Switching at rated load
Volume-III : Section-II 13
Guaranteed Technical Particulars
S. No Description Unit
2. Validity of tender :
4. Type :
5. Terms of payment :
6.E 11 KV Switchboard
a) PT Circuits
b) CT Circuits
c) DC supply Circuits
d) Other Circuits.
1. Type of tank/Installation
2. Type of mounting
4. Conforming to standard
31.8 Application -- -- -- -- --
32. Weight of oil (Kg.)
33. Total Weight (Kg.)
34. Mounting details
35 Overall dimensions
36. Characteristics (whether
graphs enclosed):
b. Magnetisation curves
37. Core
Type
d) Class of accuracy
Height mm
Length mm
Breadth mm
23. Grade of oil.
Signature of Bidder...........
Date .........................
Volume-III : Section-II 23
Guaranteed Technical Particulars
2) 100% load
3) 75% load
4) 50% load
5) 25% load
17 Regulation at :
a) Unity P.F.
b) 0.8 P.F. at 75o C
18 % Impedance at 75o C
19 Flash Test :
(i) HV 28 kV / 50 HZ for 1 minute
(ii) LV 3 kV/50 Hz for 1 minute
20 Over potential Test (Double Voltage and
Double frequency for 1 minute)
21 Impulse test
22 Mass of : (kg)
a) Core lamination (minimum)
b) Windings (minimum)
c) Tank and fittings
d) Oil
e) Oil quantity (minimum) (litre)
f) Total weight
23 Oil Data :
1. Quantity for first filling (minimum) (litre)
2. Grade of oil used
3. Maker’s name
4. BDV at the time of filling (kV)
24 Transformer:
1) Overall length x breadth x height (mm x
mm x mm)
2) Tank length x breadth x height
3) Thickness of plates for
a) Side plate (min)
b) Top and bottom plate (min)
4) Conservator Dimensions
25 Radiation:
1) Heat dissipation by tank walls excluding
top and bottom
2) Heat dissipation by cooling tube
3) Diameter and thickness of cooling tube
4) Whether calculation sheet for selecting
cooling area to ensure that the transformer is
capable of giving continuous rated output
without exceeding temperature rise is
enclosed.
26 Inter layer insulation provided in design for :
1) Top and bottom layer
Volume-III : Section-II 25
Guaranteed Technical Particulars
Signature of Bidder...........
Date .........................
Volume-III : Section-II 26
Guaranteed Technical Particulars
2.1 Aluminium
a) Carbon %
b) Manganese %
c) Phosphorus %
d) Sulphur %
e) Silicon %
2.3 Zinc
3.1 Diameter
a) Nominal mm
b) Maximum mm
c) Minimum mm
4.1 Diameter
Volume-III : Section-II 27
Guaranteed Technical Particulars
a) Nominal mm
b) Maximum mm
c) Minimum mm
5.0 Galvanizing
Signature of Bidder...........
Date .........................
Volume-III : Section-II 29
Guaranteed Technical Particulars
Signature of Bidder...........
Date .........................
Volume-III : Section-II 30
Guaranteed Technical Particulars
Signature of Bidder...........
Date .........................
Volume-III : Section-II 32
Guaranteed Technical Particulars
Surge Arrestor
Line Disconnector
Terminal Clamp
4. Surge Arrestor
5. Frequency (Hz)
Sl.
Description Particulars
No.
a) Protected
b) Total
Sl.
Description Particulars
No.
17. Dis-connector
a) Constructional Details
a) Constructional details
b) Degree of protection
b) Accurancy
c) Range (mA)
Signature of Bidder...........
Date .........................
Volume-III : Section-II 35
Guaranteed Technical Particulars
Signature of Bidder...........
Date .........................
Volume-III : Section-II 37
Guaranteed Technical Particulars
Signature of Bidder...........
Date .........................
Volume-III : Section-II 39
Guaranteed Technical Particulars
2 Type of insulator
4 Dimensions
6 Color of glaze
Signature of Bidder...........
Date .........................
Volume-III : Section-II 40
Guaranteed Technical Particulars
2 Type of insulator
4 Dimensions
6 Color of glaze
18 Performance guarantee
Signature of Bidder...........
Date .........................
Volume-III : Section-II 41
Guaranteed Technical Particulars
A. G.I.Wire :
1. Size of Wire :
3. Tensile strength :
4. Wrapping list :
5. Galvanising conforming to :
IS : 4826 – 1968
Tenderer____________________________
Common Seal
Date :
Volume-III : Section-II 42
Guaranteed Technical Particulars
a) Ground temperature
b) Thermal resistivity of soil 120 C
cm/w
c) Depth of laying 1070 mm.
35. Continuous current rating in air at 40
C
36. Maximum permissible temperature
rise of the conductor for continuous
capacity
37. Current density under conditions
stipulated in 34 above
a) Duct
b) Air
c) Ground
Volume-III : Section-II 44
Guaranteed Technical Particulars
Tenderer____________________________
Common Seal
Date :
Volume-III : Section-II 45
Guaranteed Technical Particulars
12 Power consumption W
13 Efficiency of charger %
14 Rectifier assembly
15 Type of semi-conductor
material
Thyristor - Make/Type
16 Manual voltage regulator
Type
Voltage setting range Volts
17 Degree of protection for
charger enclosure
Volume-III : Section-II 46
Guaranteed Technical Particulars
18 Rectifier transformer
Type/Make
Rating
Insulation class
% age impedance
Temperature rise 0
C
19 Contactors
Type/designation
20 AC MCCB
Type/Rating
21 DC MCCB
Type/Rating
22 Charger dimensions
Height mm
Depth mm
Width mm
23 Enclosure sheet thickness mm
Tenderer____________________________
Common Seal
Date :
Volume-III : Section-II 47
Guaranteed Technical Particulars
Tenderer____________________________
Common Seal
Date :
Volume-III : Section-II 49
Guaranteed Technical Particulars
Sl.No. Description
1. Name and place of the :
manufacturer
2. Continuous max. rating. :
3. Nominal ratio of transformer :
4. Method of Connection HV / LV :
5. Max. Current density in Windings.
a) HV wdg. A/sq.cm :
b) LV wdg. A/sq.cm :
6. a) Max. Hot Spot Temp. (Deg. C). :
b) Ambient air temp. on which :
above is based ( Deg.C).
7. a) Max. Oil temp. (Deg.C). :
b) Ambient air temp. on which :
above is based ( Deg.C).
c) Max. Winding Temperature :
(Deg. C). :
d) Ambient air temp. on which
above is based ( Deg.C).
8. No load losses at Rated voltage :
(watts)
9. Full Load losses at 75 deg C :
(watts)
10. Total losses at 100% Load (watts) :
As per BEE
11. Total Losses at 50% load (watts) :
12. Efficiency at normal voltage
a) Unity Power Factor
At 50% Load :
At 75% Load :
At full Load :
b) 0.8 Power Factor
At 50% Load :
At 75% Load :
At full Load :
13. Regulation at full load as
percentage of normal voltage. :
Volume-III : Section-II 50
Guaranteed Technical Particulars
Sl.No. Description
a) At unity power factor % :
b) At 0.8 Power factor lagging % :
14. % Impedance voltage at normal :
ratio between HV & LV windings
15. Type of transformer core – :
CRGO/Amorphous
16. Type of Insulation used in
a) HV Windings :
b) LV Windings :
17. Type of insulation used in
a) Core bolts :
b) Core bolt washers :
c) End plates :
d) Core lamination :
18. Impulse test voltage level
a. HV Windings :
b. LV Windings :
19. Characteristics of transformer oil :
20. Total content of oil in liters :
21. Whether transformer will be
transported with oil? :
22. Type of transformer tank :
23. Approx. overall dimensions
a) Height mm :
b) Breadth mm :
c) Width mm :
Tank dimensions
a) Diameter mm :
b) Height mm :
24. Excitation current (No load) Amp :
25. Full Load Current Amp :
26. Overload capacity
27. Weight of insulated conductor :
HV (min.) kg. :
LV (min.) kg. :
28. Weight of core (min.) kg :
(CRGO or Amorphous metal)
29. Weight of complete transformer :
Volume-III : Section-II 51
Guaranteed Technical Particulars
Sl.No. Description
for transport kg.
Tenderer____________________________
Common Seal
Date :
(b) Current
36. Sensitivity
Volume-III : Section-II 55
Guaranteed Technical Particulars
Tenderer____________________________
Common Seal
Date :