Webinar Stylish
Content

A. Indoor unit
1. Installation
2. New functions
3. Components
4. Removal procedures
5. New error codes
6. Options
7. Field settings

B. Outdoor units
1. RXA-A
2. MXM-M

2 Webinar split Stylish - Internal use only


A. INDOOR UNIT

Range :

3 Webinar split Stylish - Internal use only


1. Installation
Backplate
For full procedure  see installation manual

Additional information  Always use ALL screws to avoid noise problems !!!

4 Webinar split Stylish - Internal use only


2. New functions

Intelligent eye operation :


Perfect airflow this function will be the same as in EMURA 2
with
grid eye sensor Comfortable airflow operation :
! new function for Stylish !

5 Webinar split Stylish - Internal use only


2. New functions
Comfort airflow operation : HEATING MODE

6 Webinar split Stylish - Internal use only


2. New functions
Comfort airflow operation : HEATING MODE

7 Webinar split Stylish - Internal use only


2. New functions
Comfort airflow operation : COOLING & DRY MODE

8 Webinar split Stylish - Internal use only


2. New functions
Intelligent eye operation

9 Webinar split Stylish - Internal use only


2. New functions
Wireless LAN connection with : Integrated W-LAN adapter

10 Webinar split Stylish - Internal use only


2. New functions
Wireless LAN connection with : Integrated W-LAN adapter

 Install Daikin online controller APP on your device : smartphone, tablet, …


Android 4.0.3 or later
iOS 7.1.2 or later

 Connection methodes : wireless adapter with your device

Method 1 “Connect wireless adapter to home network ”


a) Connect using the WPS button on the router (IF PRESENT)
b) Connect using the SSID and KEY number

Method 2 “Connect wireless adapter directly to your device”


Connect using the SSID and KEY number

11 Webinar split Stylish - Internal use only


2. New functions
Method 1 “Connect wireless adapter to home network ”
a) Connect using the WPS button on the router (IF PRESENT)

Modem/W-LAN

Internet

WPS button

12 Webinar split Stylish - Internal use only


2. New functions
Method 1 “Connect wireless adapter to home network ”
b) Connect using the SSID and KEY number

Modem/W-LAN

Internet

13 Webinar split Stylish - Internal use only


2. New functions
Where to find : SSID & KEY numbers

14 Webinar split Stylish - Internal use only


2. New functions
Methode 2 “Connect wireless adapter directly to smart your device”

Modem/W-LAN

Internet

15 Webinar split Stylish - Internal use only


3. Components
Motors  5 !!! M1S S400:1-5 Big swing flap motor
M2S S400:6-10 Small swing flap motor
M3S S400:11-15 Left/right air direction motor
M4S S401 Front panel motor
M1F S200 Fan motor

16 Webinar split Stylish - Internal use only


3. Components
Overview
A4P / S700: Streamer unit

R1T / S301: heat exchanger thermistor

17 Webinar split Stylish - Internal use only


3. Components
Overview

M1S / S400 :
big swingflap motor

M4S / S401: front panel motor

MS / S200: fan motor

M2S / S400 : small swingflap motor


M3S / S400 : Left right air directon motor (grid eye)

18 Webinar split Stylish - Internal use only


3. Components
Overview

A6P / S601 : grid eye sensor


(& intelligent eye)

S920 / S800 : button/leds/


Signal receiver PCB

A5P / S600:
humidity sensor(not promoted)
& Indoor room sensor R2T

A7P / S801: Integrated wifi control PCB

19 Webinar split Stylish - Internal use only


4. Removal procedures
Remove casing

1) Click front panel up

2) Remove screw

20 Webinar split Stylish - Internal use only


4. Removal procedures

3) Lose connector

Always lose connector


before remove
the casing !!

In case the connector has come loose, color sequence :


Up-down  brown-yellow-blue-black-red

21 Webinar split Stylish - Internal use only


4. Removal procedures

4) Remove casing

For further removal procedures : see service manual

22 Webinar split Stylish - Internal use only


5. New errorcodes
C9 Indoor room temperature
CC Humidity sensor error

23 Webinar split Stylish - Internal use only


5. New errorcodes
AH streamer unit error

24 Webinar split Stylish - Internal use only


5. New errorcodes
CE grid eye sensor

25 Webinar split Stylish - Internal use only


6. Options
Connectivity

!!! Free S21 connector

26 Webinar split Stylish - Internal use only


6. Options
Free S21 connector : Connector is smaller than in previous models
 use cable EKRS21 for compatibility

27 Webinar split Stylish - Internal use only


6. Options

!!!

28 Webinar split Stylish - Internal use only


6. Options
How to connect EKRS21 cable :

29 Webinar split Stylish - Internal use only


7. Field settings

To set a different address In case 2 indoor units are installed in 1 room, different
addresses for 2 users can be set
Thermo off cooling : fan on/off When set temperature in cooling is reached , unit goes in
thermo off and the fan stops running. Use this setting to keep
the fan running
Autorestart After a power failure the unit automatically start up again. To
change this, set unit in “autorestart off”
Heating only Set unit in heating only mode (no cooling possible)

Cooling only Set unit in cooling only mode (no heating possible)

Adjust target set temperature in When there is a big difference between the indoor room
heating operation temperature and the set temperature in heating mode, adjust
the target set temperatue.

30 Webinar split Stylish - Internal use only


7. Field settings
To set a different address

31 Webinar split Stylish - Internal use only


7. Field settings
Thermo off cooling : fan on / fan off

32 Webinar split Stylish - Internal use only


7. Field settings
Autorestart

33 Webinar split Stylish - Internal use only


7. Field settings
Heating only

 Or on outdoor in case of multi MXM-N (see further slides)

34 Webinar split Stylish - Internal use only


7. Field settings
Cooling only

 Or on outdoor in case of multi MXM-N (see further slides)

35 Webinar split Stylish - Internal use only


7. Field settings
Adjust target set temperature in heating operation

WHAT ?

 see next slide

36 Webinar split Stylish - Internal use only


7. Field settings
Adjust target set temperature in heating operation

HOW ?

37 Webinar split Stylish - Internal use only


B. OUTDOOR UNIT

FTXA-A is compatible with outdoor units :

Multi’s

38 Webinar split Stylish - Internal use only


1. RXA-A

Only Capacities 42 & 50 have a high pressure switch

39 Webinar split Stylish - Internal use only


1. RXA-A Extra error code :

40 Webinar split Stylish - Internal use only


2. MXM-M (multi outdoor)

Also for FTXA-A

41 Webinar split Stylish - Internal use only


2. MXM-M (multi outdoor)

42 Webinar split Stylish - Internal use only


2. MXM-M (multi outdoor)

43 Webinar split Stylish - Internal use only


2. MXM-M (multi outdoor)

44 Webinar split Stylish - Internal use only


Thank you
Thank you

You might also like