You are on page 1of 2

R

Mustang Series
Standard Materials
Body & Cover: Ductile Iron ASTM A536 Coating: NSF Listed Fusion Bonded Epoxy Lined and Coated 316 Stainless Steel
H I C H

M400 (Globe) M1400 (Angle)


01/05

Globe

Angle

Trim: Elastomers:

Buna-N (standard) EPDM (optional) Viton (optional) Stainless Steel


A B D E

Stem, Nut & Spring:

Dimensions
A VALVE SIZE 4 6 8 10 12 14 16 GLOBE 150# 15 20 25-3/8 29-3/4 34 39 41-3/8 B GLOBE 300# 15-5/8 21 26-3/8 31-1/8 35-1/2 40-1/2 43-1/2 C COVER TO CENTER 10-5/8 13-3/8 16 17-1/8 20-7/8 24-1/4 25 D ANGLE 150# 7-1/2 10 12-3/4 14-7/8 17 19-1/2 20-13/16 E ANGLE 300# 7-7/8 10-1/2 13-1/4 15-9/16 17-3/4 20-1/4 21-5/8 F ANGLE 150# 5 6 8 8-5/8 13-3/4 14-7/8 15-11/16 G ANGLE 300# 5-5/16 6-1/2 8-1/2 9-5/16 14-1/2 15-5/8 16-1/2 H PORT SIZE 3/4 3/4 1 1 1 1 1 I PORT SIZE 3/4 3/4 1 1 1-1/4 1-1/2 2 SHIPPING WEIGHTS* 190 320 650 940 1500 1675 3100
*Estimated in lbs.

Description
The Watts ACV Models M400 and M1400 are full port, single chamber basic valves that incorporate a two-piece disc and diaphragm assembly. This assembly is the only moving part within the valve allowing it to open, close, or modulate as commanded by the pilot control system. The lower portion of this two-piece assembly is a mechanical check feature, which acts independent of diaphragm position or pilot control system, and provides immediate check action when flow ceases. Model M400: Globe Pattern Single Chamber Basic Valve with Mechanical Check Feature Model M1400: Angle Pattern Single Chamber Basic Valve with Mechanical Check Feature

Operating Pressure
150 Flanged = 250 psi / 300 Flanged = 400 psi

Operating Temperature
Buna-N: 160F Maximum EPDM: 300F Maximum Viton: 250F Maximum

8550 Hansen Road Houston, Texas 77075 (Ph) 713.943.0688 (Fx) 713.944.9445 www.wattsacv.com

Flow Data - ACV M400 (Globe) / M1400 (Angle)


Valve Size - Inches Maximum Continuous Flow Rate Gpm (Water) Maximum Intermittent Flow Rate Gpm (Water) CV Factor GPM (Globe) CV Factor GPM (Angle) 4 800 1000 175 215 6 1850 2300 490 571 8 3100 4000 770 990 10 5000 6250 1200 1530 12 7000 8900 1750 2525 14 8500 10800 2125 2885 16 11100 14100 2890 3575
Estimated

Maximum continuous flow based on velocity of 20 ft. per second. Maximum intermittent flow based on velocity of 25 ft. per second. The CV factor of a valve is the flow rate in US GPM at 60 F that will cause a 1 psi drop in pressure. The factors stated are based upon a fully open valve. CV factor can be used in the following equations to determine Flow (Q) and Pressure Drop (r P): Q (Flow) = CV r P rP (Pressure Drop) = (Q/CV)2

Headloss

Angle Globe
4

10

10

100 80 60 40

Pressure Drop (p.s.i.)

30 20

10 8 6 4 3 2

2 100,000

6 8 10

20

40 60 80 100

200

500

1000

2000

5000 10000 20000

Flow Rate - Gallons per minute (Water)

Valve Cover cover capacity Chamber Capacity


Valve Size (in) fl.oz. U.S. Gal 4 22 6 70 1-1/4 2-1/2 4 6-1/2 9-1/2 8 10 12 14 16

Valve Travel
Valve Size (in) Travel (in) 4 1 6 1-1/2 8 2 10 2-1/2 12 3 14 3-1/2 16 4

8550 Hansen Road Houston, Texas 77075 (Ph) 713.943.0688 (Fx) 713.944.9445 www.wattsacv.com

12 14 16

12 14 16