ANCHOR BOLT DESIGN

Axial load/ pull up load, T=26 kip


Yield strength of steel, fy = 50 ksi
Tensile strength of steel, fu= 58 ksi
Assume, bolt dia, d= 16mm
Area, A =0.312 in2

For pull up
Tensile strength of steel, Ft= 0.375xFu =21.75 ksi

For shear
For pull up
Tensile strength of steel, Ft= 0.4xFu =23.2 ksi
Maximum capacity of one bolt, qmax= 21.75 x 0.312 = 6.786 kip
Require number of bolt, N= 26/6.786 =4 nos
Allowable bond stress, u=

Embedded length, Ld = 12.3 in ( Ld = Asfs/U o )


I)
ii) 13.13 in ( Ld = 0.04AbFu/ f'c )
iii) 14.61 in ( Ld = 0.0004dbFu )
iv) 12 in (Minimum embedded length)

Provide minimum embedded length= 14.61 inch


Considering 6 nos 16mm dia anchor bolt is sufficient
Total length of anchor bolt = 14.61 +4 + (12 x 0.63)
= 26.17 inch
= 665 mm
Considered base plate thickness= 16mm
(4 mm added
ADEQUATE