You are on page 1of 20

PCPrD0902

Toarr<tN
AIR OOLED PACKAGED

FLOOR STANDING TYPE


DUCT TYPE
COOLING ONLY 50Hz B-410A

4.1,
7A :
R
DUCT TYPE
I
L

FLOOH STANDING TYPE


DIRECT AIR BLOW TYPE

E
DUCT CONNECTION TYPE

ffi
HFC R-4 l0ALine LIp
for Factories and Oftices
We have entered an era in which being recognized as an environmentally
responsible corporate citizen has taken utmost importance.
Even when selecting air conditioners, a new model featuring HFC R-410A
refrigerant could be the perfect step in promoting your corporate image.

Product Line Up m4ioil ="&


FLOOR STANDTNG TypE Cooling only

29.3
Capacity'" 100,000
25,200

DIRECT AIR BLOW


TYPE
I= E:
t- l=
lu
c
F E IE tffi
L-- t=
z FVGRO5NVl FVGRO6NV,I FVGROSNVl FVGRl ONVl
6 RURO8NY1
z RURT ONY1

ffiffi
FVPGBlONYl
tL
Outdoor unit RURlONYl V
OUTDOOR UNIT
F,",*""*-.;l

DUCr rypE . -C,qrlllg r!]yl


HP 5 6 8
iranar-iirr' kW 14.7 17.6 23.5 29.3
\rcr]rcrrrr r.rr ' Btu/h 50,000 60,000 100,000
kcal/h 12,600 15,100 25,200

DUCT TYPE
ispecil caiions Pad6 'l
q,.= r\,1 F\, flq;
13,14 lndoor
Dimensiors Page Unit FDRO5NYl FDF06NYl FDROSNY1 FDB] ONY1
Ouldoor !nii RURO6NYl BUBOSNYl

OUTDOOR UNIT

F"""-;;a
'zCapac ly nc udes indoor,an motor heal
. DIRECT AIR BLOW TYPE I DUCT CONNECTION TYPE I
Direct air blow from indoor unit . DUCT TYPE I
with plenum Air blow via connected ducts
a Comlortable factory air conditioning using multiple indoor
a Comfortable air conditioning of the entire faclory by connecting a
units installed in accordance with the space.
blow duct at the lop of the indoor unit.
a lnstallation is next to walls, so units will not affect the
factory layout even if the changes are made.
Nore Ducls ro be prccurcd localy.

-=ffifr"--

50Hz
't3 18L
15 Nice,
35.2 52.8 58.6
120.000 160.00q 180.000 - 200 000 cool air in the factory
30.200 1 t0,300 45,400 s0 400
or in the cafeteria

L $
l
a3r-:-!@
Effi
-liMrlttf*n
ffiffi
\'F'
.VPGRl3NY1 FVPGRl5NYl
Y--
FVPGHlSNYl FVPGR2ONY,I
Y RURtaNYt RuRlSNYl ntrnznltw
"-
=*,

45300 50,400

!F !: s lr
_l)
,;.

FDR1lNlll , FD.)B1!NY1 FDR18NY1 FQR2ONY1


RUR13NY1 BUR 15NY1 zuR18NY1 BUR2ONY1
AIR COOLED PACKAGED AIB CONDITIONERS

Flexible design
I FLOOR STANDING TYPE
DIRECT AIR BLOW TYPE Enhanced varieties of factory

U Faclory mod fical on


I Cohtacl sa es ior more inlomallon

l,4odily wiring lor cenlral control


adapler kir (DAT107A55) nslallation

Change lan molor and pulley


Discharge grill plenum chamber
Side discharge qrlon discharge p enum chamber

FVGRlONVl
Frcnt suction h glr efliciency liLlerchamber

Froni suction base llange lorhont suction


hlgh etllciency tiller chamber

I Suction grillfor front suction


hish etticiency filter chamber
DUCT CONNECTION TYPE
tr
tr tr
tr tr
Remoie senso(Themistor ior suciion a r) !
Alliresh airapplication I
Low ouldoor iemp.15'C application
and long pipe 70rn applcalon
I
cenlra conlro adaprorkt
(exl€.na termna for ON/OFF, abnorma)r DAT]07455

LCD rernole conlrolleG BFCrC62

inielligent Touch ControlleP DCS601C5l


Central remote contro er,
Unified ON/OFFconlroLeF DCS301B61
BURlONYl
FVPGRlONYl ScheduletimeF DST3olBA6l
Bemore seqsor (lhernislor lor
for suction airlJ
airp Kqcsor'1l
Kqcsol
t R".ol" - BFCr\"6r
"o"ir"ll"'o I

rW ng modlicaton is needed on lloor sta.d modelto connectwith cenlralconlro ADP kl

I DUCT TYPE 'zNeed lo use


3central
centralconvo adapler kll ior opton.onnecton
.onl rol ad aple r kl and Lco remole conlroler is necessary lor oplion conneclion

Quiet Operation
Equipped with scroll compressor for
quiet operation
FDRlONYl
Smooth running, Low
vibration, low operating
sound.

3**,) FUR05NYT 59 dB 60 dB
and great reliability.
Easy operation
Digital remote control comes standard Refrigerant pre charged for up to 7.5 metres
with indoor unit. I Allowable rerrigerant pjpe length and level difference

Temperature setting is possible by button operation. The sei E;;;;It ,*,h""I T vil"*I
temperature is conveniently displayed on the LED.
FURO5NY],2ONY] zs ." ,,"?9"1,....- so-
Floor standing type (Shndard accessory) NoleirAddiliona retrigerant charging is required itthe retrigerantpipe s longerthanihe
ndicared lengrh.

4-direction piping affords more freedom


ol layOut (ApPriesro RURo5N/o6N)
Piping can be run from the front, bottom, right or rear surface
17
according to how the unit is installed.
ln case of RUB08-20N, piplng can be drawn out in two
directionsjront, and under side.
A Compressor operar on lamp.

r.g Temp. stlng up .0 LED disptay Cool operalion lamp.

Note I Lt.annolbe usediorFVPGBlO 20NYl


-40

Durability
Duct type (opiionat accessory) Heat exchange fins provided with
anti'COf fOSiOn tfeatment (Appr€s10ar oLtdoo, Ln,ts)
To achieve increased durability by improved resistance to salt
corrosion and atmospheric pollution, coated PE fins (with
special acryl pretreatment) are used for the heat exchanger of
the outdoor unit.

Space savings
2 TenFeralure scale 6 Fan nd cator amp lnstallation space is saved thanks to a more
3 Temperalure selting 7 Coollndlcalor lamp compact outdoor unit, This also makes it
Mode seling 'O compressor 2 indicator tahp
easier to install.
A_.

Previous 20HP outdoor unit


NEriv 53%
RUB2oNYI space saved

Design flexibility BUGlOAUY1 x 2 120HP) compared to


pevious model

Designed for long refrigerant piping. 1


1;
50 m maximum length and 30 m maximum level difference I
to cover medium- and large-scale building needs. :)
-' 765
l.240mm
Outdoor unit roof
inctallation possible
tor plenty ol leeway.
lo

diflerence
I FLOOR STANDING TYPE
DIRECT AIR BLOW TYPE

380 415 V

11.2

unit

14 \a 25

4 5 (Charqed lor7.5

Piping unil

T FLOOR STANDING TYPE


DUCT CONNECTION TYPE

5,720
Belt Drve
'15

compressor Hermelica y sealed scrolliype


9.0 5.0+5 0 67+6.7 7 5+7.5 90+9.0
POLYOL ESTER
L 3.3 50 6.5
Befrioerant charae {B-410A) kq 6 0 (Charoed Ior7.5 m) 4.5 (Charo€d lor 7.5 nr) 80 (Charged ror 75 m)
380V dBA 61 61 62 63 63
415V dBA 62 62 63 64 164
D mensions (H).r'VxD) 1.680)e30x765 1,680x1,240x765
206 243 319 322 329
.CDB
21 lo 46
Beirigerant lndoor Lquid a'l2.7 (Btazinol d15.9 (Brazrno)
Piping Gas d28.6 (Blazinq) d34.9 (B.azinq)
Dra n PS 18 nlernallhread

Gas d28.6 (Brazinq)


D'a n
50
30
\ore -D.rForool'q'ap. ie.daodpoo"'.rororr 9to drionr'q.r-, a' eno.,.'coB '9.'civB ou'doo renp 35'cDB Tq-'. e ge.a o ppno ( r 'o'ro-!r
!-., r o.t , h.r b.. -orvp' o ral.6.6ar,r.dd'.o.di 9 oll5pa'"nete.qaid(.F"a D." qop"'ao--"-F.a Fsa'6'o.p,har!'ShF.osnq'
3capac
ly inc udes indoor lan molor heal
DUCT TYPE
FDBlONYl
RURlONYl

Bel drive
51
=
130)€50 500x1,130>€50

Hermelically sealed scro typ€

YOL ESTEB

6l
t

PS 1B lnlerna lhread

FDR13NY1
BUB2ONYl

21.5
35.1
88.4

Airfrow raie (H)

I
unit
14 ta 25

POLYOL ESTER

64

Ppns
unit

unit

NolerBaied.oolngcapa(lesarebasedonlheolow'n!conduons:Sucllonlemp.27"CDB19.5'cwB:ouldoorremp35"CDB.Equivrelrigeratonppng5m(hozontar)
d,..hoi,.herbe@rvF''o,\rF.r-d.,rco4.oong.oJtSoa'anet-r\do.caDu.rqooera.01..ese.atu6sa.6<oaF4hdrhq.pornq.od-be.!o.o.ors
3capa.ly inc udes indoorlan moro. heai.
Fan Performance
I FLOOR STANDING TYPE
DUCT CONNECTION TYPE

FVPGR,I3NYl
FVPGBl5NYl

o
I
E30
E

,9
E

!l!r0

Air flow rate (m"/min) Air flow rate (m"/min)

FVPGFlsNY,I
FVPGB20NYl

r-
DUCT TYPE

FDR05NYl

I
E
E
9,s

E
g
LJ]

Air llow rate (mrmin) Air rlow rale (mr/min)

FDBoSNY1
J
"tI
I
,F

E"i
I le
u
$-t E

.9 ,s[ !

9lh
Y I t,J

,t
I
I

Air ilow rate (mr/min)

FDB13NY1 FDRlSNYT
FDBlsNYl S FDR2ONYI

6 o
f6 a
gE g€5
E
3n
E,'
z
t t
9," ;io

Air flow rate (m"/min) Air flow rate (m,/min)


I FLOOH STANDING TYPE
DIRECT AIR BLOW TYPE

FVGROsMOSN FVGROSMlON
RUROSMO6N RURO8WlON

Hlr

I FLOOR STANDING TYPE


DUCT CONNECTION TYPE
1
FVPGRlON FVPGR13M5Ml8N/2ON
EURlON RUR13Ml5M18M2ON

DUCT TYPE
FDB05WO6N FDBOSN/,ION FDB13Ml5N/18N/2ON
BUB05M)6N BUBO8MlON BUB13NA5N/18N/2ON
DIMENSIONS tu"it,,,r
I FLOOR STANDING TYPE
DIRECT AIR BLOW TYPE

FVGRO5NVl
FVGRO6NVl B c D

FVGRO5NVl 750 124 d95 d 19.1


FVGROSNVl FVGRO6NVl 750 124 d9.5 d 19.1

1 E- ---
*l
FVGRO8NV] 950 920 a 12.7 622.2
(,Liquid pipe conn. (C) C122aI b'azirg

ldl l @ Gas pipe conn. (D) c1220T braz ns


@ Upper drain oullet (PS 1B lnlerna thread)
@ Power supply & conlrol wire iniake
O Digital remote conlroller

FVGRlONVl

O Liquid pipe conn. (o 12 -7) C122or fiaztng


e)Gas plpe conn. @2A.q U22AT b'azing
O Upper diain outlet (PS 1B lnternallhread)
@ Power suppy & controlwire inlake
O Digital rcmole coniroller

Fpffi,*l

10
DIMENSIONS p"i,',,r
I FLOOR STANDING TYPE
DUCT CONNECTION TYPE

FVPGRlONYl
I
(, Liquid p pe conn. (o 12.7) C122or fiazins
@ Gas pipe conn. (o 28.6) C1220T brazing
@ Upper drain ouiet (PS 1B lnlernaithread)
@ Lower drain outet (PS 1B lnlernalihread)
@ Powersupply & controlwire intake
@ Digilal rcmote coniroler

FVPGB'I3NYl
B C D G H J K L
FVPGRl5NYl FVPGRl3NY] 1170 477 3!8 295 344 1210 70 1144 245 612.7 d286
FVPGR.ISNYl FVPGR]5NY1 1170 4n 398 295 344 1210 1170 1144 205 d15.9 034.9
FVPGR20NYl FVPGBl8NYl 1474 558 438 407 1510 1470 237 d15.9 634.9
FVPGR2ONY] 147A 558 438 401 1510 1470 231 d15.9 034.9

O Liquid pipe conn. ( K ) C122OI *azing


e) Gas pipe conn. ( L ) C1220T brazins
G) Upperdrain outlet (PS lB nlernailhread)
(4) Lowerdrain ouiei (PS 1B nternallhread)
O Power supply & conllolwire iniake
@ Dioilal remote coniroller

soE,so;;l
soR3150157
soR3r50153

11
DUCT TYPE

FDRO5NYl

OLiquid pipe connecton (o 9.5)


@Gas pip€ conneciion (o 19.1)
@Drain pipe connection (PS lB lnlernalthread)
G) Eadh terminal

@Suspension bracket

Fp#"*^ I

DUCT TYPE

FDRO6NYl

ZlL \

L*],

iltl
OLiquid pipe connection (a 9.5)
@Gas pipe connection (o 19.1)
(ODrain pipe connection (PS 1B lnternalthread)
@Eadh leminal
OPower suppty
@ Suspension bracket

12
DIMENSIONS ."",.,,,,
DIJCT TYPE

FDFOSNYl / lONYl

tr-- -J
t=I
ilmffii
lili
Ilffit
r----
="]--n
lFDR0sNYll IFDRl0NYlI
(DLiquid pipe conneclon (o 12.7)
@ Gas pipe conneclion lc)
€)Drain pipeconnection
(PS 1B lniernalthread)
@) Earth lermlna

$s aOSuspension bracket

-1"

B C D E G
FDBOSNY] 876 4XP.180=720 I130 1180 1230 o22-?
FDRlONYl I076 5XP.180.900 1330 1380 1430 028.6

DUCT TYPE

FDR13NY1 / 15NY1 /18NY1 /2ONY1

lFDRlsNYll lFDRlsNYll
lFDRlsNYll IFDB20NY1]
O EvaPoraior air inlel conneclion
er Evaporator air outlei connection
G) L quid pipe conneclion (J)
(O cas pipe conneclion (K)
ODrain pipe connecrion
B C D E G H J K (PS 1B lnternalthroad)
FDRl3NYl 10.031 ho es lxPl50=135( 1442 1620 1710 1750 1770 24 a12.t 028 6
@Earlh lerminal
't7t 0
8)Power supply intake
FDBl5NY] l0 03lhoes IXP 150=135C 1442 1620 1750 1T7A 24 015.9 034 9
@The holes lor anchor bolts
FDR]8NY1
12.d31hoes 11XP1t0=165t 1162 1980 2470 2110 2224 54 0159 034I
FDR2ONYl

Noles: rPrepared holeslor M4iappng screw


OUTDOOR UNIT

RUR05NYl
RUR06NYI

@ Liq uid pips conn ecrion


@ Seryice pod (in the unir)
@ Grounding lerm nal Ms (in switch bor)
@ Rel gerani plplng inlake
(O Power supply wning inhk6
oLo-rrore eflahe [;;]o;-

OUTDOOR UNIT

FUROSNYl
RURl ONY1 Noles)1 ,Delall Fo. Frc.r S d6 Afd Detail For Bonom side
ln.lical€ Th6 Dimensions Arler Fixing The Anached piping.

(D) Breins mnneciion

112.7 Fla€ conneclion

DETA L FOR FBONT S DE

DETA L FOF BOTTOII SIDE

O Liquid pipe connection pon


OGasppe &nnecllon pon

aO Powercord roulinq hole (sde)


@ Powercord routi.s hoe (nonl)
G) Powerco.d rolling ho e (lronl)
B c D O Powe. cord rooiing hote (bofloml
BUROSNY] 69 16 165 :22_2 @ Wne rouli.g hole (lronl)
O Pipe routins hol6 (lronl)
--;;"*^r
BUB]ONY1 75 22 171 i286 : 3DO62A37A
G Pipe routing hole (bonom)

14
IIIMENSIONS ,""*,,,,
OUTDOOR UNIT

1102
RURl3NY'I rPrh oirordatr bo' hos)
I
RUR15NY1
RUR18NY1
RUR2ONYl

#Iil \riv
I N-r- r
li"[ H -]ljm[5n
-l
163 43
lEllHrffi+
.176

r;;
DETAIL FOR FBONT S DE

an
E ]--er-llf
- ]
lll.l s lllffiffi
roJ
E!l"l
lfl.JH*
176
liacl I

DETA L FOR BOTTOM S]DE

O Lquid pipe connecton pod


Noles)1.oelai Stde
For Fronr side And DetarrFor Bolrom @ cas pipe conneclion port
lndicate The Dimen6 ons Aller Fxing The aflached P p n9. (o croundino lerminal
@ Power cord rouling hoe (side)
B c (B) Brainq @nnector 6 Power cord roulins hol6 (rronl)
22 )28.6 i12.7 O Power cord roulins hole (rronl)
(C) Flare conneclion O Power cord routing hote (bottom)
24 ;349 n5.9 19 wne routing ho e (iront)
@ Pipe routing hoe (rrofl)
(0 Pipe routinq hole (botlom)

15
FVGRO5NVl
FVGRO6NVl
FVGROSNVl
FVGRlONVl

FVPGRl3NYl
FVPGRl5NYl
FVPGRlSNYl
FVPGR20NYl

16
nit: mm

! For RUR05NY1/06NY1
When there is an obstruction When there is an obstruction
on the inlet side on the outlet side
When the overhead space is open When the overhead space is open
1. For single unit installation 1. For s ng e unit
insta lation
When there is an I

obstruction only
on the inlet side -t.
2. fo. se',es insralalron
(more than two units) +'

When there are


obstructions on
t...
both sides

When there is an obstruclion


in the overhead space
1. For single unit
installation
2. For series installation
(more than two units)
!
When there are
obsiructlons on
both sides 2. For series installation
(more than two units)

When there is an obstruction


in the overhead space
1. For single unit installation When there are obstructions on both
the inlet and outlet sides
Doh6rn I Fororh€rpafferns pear€ rel.r

When lhe obsiruction on lhe outlel side s higher lhan


the unll iiself (There is no linril io the height oi the
obstruclion on ihe outel side.) It
When the overhead space is open
1. For Single unit installation

L>H

2. For series installation


2. For series installation (more than two units) (more than two units)
When there are obstructions
on the inlet side and
both lateral
sides

17
t For RUR08NY1/1 0NY1/1 3NY1/1 5NY1/1 8NY1/20NY1 (Please refer lo engineerng dalabook lor olher inslalaton palterns )

For single unit installation For installation in rows

Pattern 1 Paltern 1

.t

io
/t-n'/
i F.-,
.,,,,1, )i)) )i, ,2,,,,,.

-1*,,^.=- Patlern 2

Pattern 3 Pattern 3 wal h6 qhronL€sl,ict6d

, t*"",^""

For centralized group layout


Paltern 1

//,/a, 1,"::.:-:.:,,,,,,,,,,,,// ,zr.


I,/
na
,
,,
/.
W'
Pattern 2
/ / /,, l:.,iry'r-,,,, / / / / / / / / // / / ,at
,@@z ,/,

,/,

rHeights
oiwals in.ase ol Parterns r and 2:

side Heqlrlunrestrcted.
nsta alion space 1o be shown n th s drawing s based on the coolnq operat on at 35 degrees ouldoor a rremperaiure
When the desgn ouldoor an lemperalLre exceeds 35 degrees or the load exceeds max mom ab lty because ol much
.generalon oadolhealina ouldoo. un l,lake the sucl on s de space more broadly than lhe space io be shown in this draw ng.
'l1lhe above wal heights are exceeded then h2l2 and hl/2 should be added toihe fronr and suclion side seryce spaces
llF--'t--'l n r
*, d]l--H
il ilffi ll# '*:" .l
respectively as shown in lhe liQUre on the rqhl.
rwhen nsla lnO the un ls mosl appropriate paflern should be se ected lrom those shown above in order 10 obtain the best tl in
the space avaiable a ways bear.O n m nd the need lo eave enough space lor a person to pass between un ts and wa I and
for the an to circuLale lree y.

,o,ld?o 'oud
"." d.co r )
]l_----u.| ae
'The un ls shou d be inslaled to leave suflic enl spa.e al lhe lront lor rhe on sre relrgeranl p ping work lo be ca(led out

t 18
w'llins Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
'
l\ lmproper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.

' Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories- Use ol unauthorised parts and accessories or
improper installation of parts and accessories can result in water or relrigerant leakage, electrical
shock, lire or explosion.

'Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
ll you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


'1. Air conditioners shouid not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. lf the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. lf you need to install
the outdoor unit close to the sea shore, contact your local diskibutor.

Oealer PT DA'K'N
HEAD oFFICE l
Wisma KE,AI 18th Floor
Jl. JendralSudlrman Kav.3, JakartaPusal10220
Telp : +6221 5724 377
Fax : +6221 5724 366/55
Websile rwwwdaikin.co.d
SEFVICE AIiD SPAFE PAXTE, 92899 . TBiniru Ce €r, Telp. : 021 -295 6t 950 . Bekasi, Te p, 021 2945 0585,
Tanqennq,Telp,r02l-53141l95.Bandung,Tep.:022-5225150.SnErang,Tetp.:0243412695iyoolakarta,Ietp.0274-551321
surab.rd,Telp.:031 503 1138 . Denpassr,16 p.:0361-900 5514 r irakassar, Te o.: 0411-446 263 . PEIembang, Tetp.:0711,319 776
Pek nbaru,Ietp, 0761-561139

Daikin Contact Center : 0800 1 081 081 O0ll Free)


Spec ficalions, des gis and olher contenl appearing in lhis brochure are curenl as oi March 2OO9 but sublect to change wihoul rotice.