ANORIZ Hydro 12. AM-010 Application Module (6Al, 440, 4PT100) ‘The AM-010 module is an extension module for the boards AB-310 and AB-320. Thus, the number of analog inputs and outputs of the AB-boards can be expanded as needed. For the maximum number of AM-010 in the device please reter to Device Features. Top view of module AM-010 12.1, Features * 6x Analog input for 4 .. 20 mA, +20mA or +10 V + 2x Temperature measuring (2- or 3-wire measuring of PT100) + 4x Analog output for 4 .. 20 mA, +20 mA or + 10 V DGB-004-1.02 HIPASE Data Sheets Page 143 of 353, 12.2. Ordering data and technical data Complete board Material number Board woth Went Dimensions inl. terminals (Height x Wiethx Depth) Power consumption (Interna) Temperature range wih specied accuracy Working temperature range ‘lowed sit postion in MEDIUM sized housing ‘lowed sit postion in LARGE sized housing Characteristic value in coniguraton code of device 232x178 x20mm CGB.014- (can not be ordered separately) Page 144 of 353 DGB-004-1.02 HIPASE Data Sheets ANORIZ Hydro 12.3, Analog Inputs The group Alt .. Alg and the group Al4 .. Al6 are internally supplied separately. For a redundant configuration for ‘example a pair of Alt and Ald must be used. CAUTION: The default setting for the measuring ranges of the inputs is voltage measurement. To avoid damaging the module, before the first application of the input signals the proper input range of the input signals must be selected by HIPASE engineering tool! Technical Data Analog Inputs Data points ‘Measuring range of input signal erm measuring ransducar) Max. alowod input signal ‘Behavior at signal overage or wie broak Input frequency range ‘rout titer tine constant hardware ‘Accuracy of module input in votage measuring mado within speciiod tomporature range {accuracy of extemal measuring transducer not included) ‘Accuracy of module input in curent measuring mode within spect temperature range {accuracy of extrnal measuring transducer not included) Rozoltion Sampling rato Moimum burden atvotage measuring mode Maximum burden a current measuring mode EMC immunity Isolation volage ‘Special wiing recommendations Wire cross section alt. 6 Alt. AI6 Following ranges are configurable by using jumpers: 10 . +40 VDC (factory dofauit satin) (0.. 20 mA (select mode 0 ..20 mA or 4.20 mA in HIPASE. Engineering Too's) (CAUTION: In boars parameters settings of HIPA: ‘Tool for AM-O10 the measuring range nas to bes contiguted on hardware by jumper positions. £1200, 22 mA ‘Saturation esp, 20r0 0. 500 He better 800 us, lowpass 1. order (:3 48 @ 600 Hz) 1% 1% 15 bit + 1 biteign [ADC 4 kepe,rodused to theps for FUP 204Ohm 10.0hm 1EC 6025526, EN 6119-2, IEC 61850:9.£4.2.0 ‘Connection - Ground: 1.5 kV {50 He), 2.5 KV peak (12/50 ps) (Connection - Connection: 1.5 kV (50 Hz), 2.5 KV peak (12/50 ps) Place shielded wires with low inductance and do not place neat ines that are subjected to high voltage or curent changes. Apply cable shield atthe ground point faston plug) of AM-OT0! 1.0... 1.8 mm stranded, wih ferrule DGB-004-1.02 HIPASE Data Sheets Page 145 of 353, ‘Wire cross section AWG (keri) 17-15 stranded, with ferule Page 146 of 353 DGB-004-1.02 HIPASE Data Sheets ANORIZL Hydro Configuration of measuring range A coincidence between the selected range by jumper position and the tool parameters must be ensured! in header Analog Input Measuring rango ‘Measuring range for jumper 0.20 mAresp. 4.20mA “=10VDC xao2 At xs02 A ‘Tamper connection: ‘Tamper connection: xe02 Ag Pin3.6 and 4-6 Pint-3 and 2-4 46 246 x702 Ae xe02 AS 135 902 Ae ‘Assignment Alt .. AI6 with jumper position DGB-004-1.02 HIPASE Data Sheets Page 147 of 353, Data points - Outputs Data point name Value Board Parameters ‘Transtomer primary value ‘Transfomer secondary value Rated value ‘Transfomer ‘connected Minimum value Maximum value Offset “Time constant lowpass fiter Fit characterise lowpass fitor Measuring range Daa ype fate Value seting taut range “aie 1 1000 v6 wovanvaal, 10008 Sim so.stv av 004.0088 001 +002.-+002A 901 + -se00 v4 Wivanva'sl, 10008 oom en in a + -s000 v8 WNARVAel, 1000V,A hm 1 sea v8 WivenVAel, — 1000V.8 Om 200000 +200000 pu os ‘sous. 190m8 Sms Kein ter Titpass 1 Orang Tetpass ang Tiles 2 Sere “10. +1000 10.10 o.2om is 4..20m8 Value pu ‘Setting step 0,001 V, A, opty 0,001 V, A, 0,001 V.A 0,001 V, A, 0000001 pu tus Description Value of signal of analog input Description Rated input value of current voltage transformer or measuring twansducor Rotor to data sheot of measuring transducer. ‘Selectable only if parameter Transformer connected’ Is ‘Yes! Rated output value of measuring transducer connected wih HIPASE device, Feter to dala sheet of measuring transducer. ‘Selectable only f parameter Transformer connected Is ‘Yes: Rated value of measured plant variable, ‘Selectable only if parameter Transformer connected Is Yes ‘Yes: input scaling based on transtormer data No: input scaling based on straight line equation y= kx +4 ‘Assignment of the lower end range ofthe analog input (4 mA, -10 \, 20 mA) fo the lowest possible primary value ofthe transducer connected to HIPASE device. [Assignment ofthe upper end range ofthe analog input (20 mA, +10 V) tothe highest possible primary value o the transducer Connected to HIPASE device. COset correction value used to compensate a possible DC ‘component ofthe input signal Filter ime constant for one or two lowpass fiers. ‘Activation and setin of lowpass fiter steepness. lowpass fter 1. order. 20 dB each decade lowpass fiter 2. order 40 dB each decade 4.20 mA range suppor wire-break detection Page 148 of 353 DGB-004-1.02 HIPASE Data Sheets ANORTZL Hydro Connection of Analog Input M- “| Measuring 1 Transducer 2 1in/vin D [4.20ma cou 2 ALO1 or0.. 10V | ‘Connection of measuring transducer with 4.. 20 moO. TOV output to analog inout Alt (Other Inouts Al-02 .. AL-06 connected inthe same way) DGB-004-1.02 HIPASE Data Sheets Page 149 of 353, 12.4. Analog Outputs ‘The selection of the output signal range is done exclusively in HIPASE engineering tool. No jumpers must be set. The group AO1 ... AOS and the group AOS .. AOS are internally supplied separately. For a redundant configuration for example a pair of AO-01 and AO-04 must be used. CAUTION: The default setting for the outputs is voltage output. I a voltage output is connected to a current input, the internal power supply can be overloaded for the group AO-01 .. AO-03 or AO-04 ... AO-06. To avoid damaging the module, before the first application of the output signals the proper output range of the output signals must be selected by HIPASE engineering tool! Technical Data ‘Analog Outputs Data points Output signal Behavior a signal ovetrange or wire break up treqvency range uur titer time constant nareware ‘Accuracy of module output within spectied temperature range Resolution Output rate Max. burden at curent ouput mode Min, burden at voltage output mode EMC immunity Isolation voltage Special wirng recommendations Wire cross section Wire cross section AWG (kemi) aot .4 Configurable ranges in HIPASE Engineering Too! 40...+10 VDC (defaut setting) 0..20mA, 42.20mA ‘Saturation resp, ze10 0. 100 Hz £800 ps low-pass 1, order (-3.8 @ 600 He) 1% {5bit+ 1 it sign 1 ksps. 500 Ohm 1kOhm TEC 60255-26, EN 6131-2, IEC 61850-3 £4.20 Connection - Ground: 1.5 kV (50 H2), 2.5 KV peak (12/50 us) (Connection - Connection: 1.5 kV (50 Hz), 2.5 KV peak (1.2150 ys) Place shielded wires with low inductance and do not place near ines that are subjected to high votage or current changes. Apply cable shiold a the ground point (fasion plug) of AM-O101 1.0.1.5 mm stranded, with ferrule 17.15 stranded, with feria Page 150 of 353 DGB-004-1.02 HIPASE Data Sheets ANORIZ Hydro Board parameter Paramtarnave Yale sting range Deut Sang Description ‘Assignment of alowor limit value ofthe Gata point to the lower end of paras eho ue s00000) a 9.000001 the range of the analog output (4 mA, OMA, DV, -10V) ‘Assignment of an upper limit value of the data point to the upper end Maxmumvalue 1.200000 1000 0,000001 Gf the range of the analog output (20 mA, +10 V). -10..+ 10vDC ‘Signal range 0..20mA Be 4.20 mA range supports wire-break detection 4.20 Connection of Analog Output ~ BHT) | x1 4..20ma —-*TTa aco | 14 ee Connection of pointer instrument with moving coil movement to analog output AOT (Other Quiputs AO2... AOS connected in the same way) DGB-004-1.02 HIPASE Data Sheets Page 151 of 353 12.5. Temperature Measuring The transducer is designed for use with PT100 elements in 2- and 3-wire configuration. A temperature range of - 50°C to +200°C would be possible but due to compatibility reasons the range is limited to -40°C to +120°C. Temperatures below -40°C are interpreted as wiring shorts and above +120°C as wire break which will in both case be annunciated. Functional Principle ‘The measuring principle is based on a bridge circuit which is supplied by a reference voltage source. The voltage difference of the two bridge branches is applied for the computation of the temperature. Technical Data P7100 temperature evaluation Compatible measuring sensors Possible connections Data point Max. allowed veitago betweon tominals X19, 10, 11, 12 Moasuing range tomperature solution ADC ‘Actualzation rato of temperature value Measuring resolution ‘Accuracy of tomperature detection within specie tomporature rato EMV immunity Isolation voltage ‘Special wing recommendations Prd Ziel TF101 / G35KV PT100 DIN /2 wire 2: or 3wire:measuting matnod for PT100 evaluation Prt Pra 0,7 Vpoak AG 0,7 VOG 50... 200°C (-§8 . 392°) 151 bitsgn 100 ouput values 2 1k 1k IEC 60265 .26, EN61191-2, IEC 618609 £4.20 Connection - Ground: 1.5 kV (50 He}, 2.5 KV poak (12/50 us) (Connection - Connection: 1.5 kV (50 Hz), 2.5 KV peak (1.2/50 ys) Place shielded wires with low inductance and do nat place neat ines that are subjected to high votage or current changes. Apoly cable shield at the ground point (fasion plug) of AM-010! Page 152 of 353 DGB-004-1.02 HIPASE Data Sheets ANORIZ Hydro Board parameter Parameter name Datatype Value setting Default value Description 1. 2.wre PT100 Mode ‘Single Choice 2wire 2. Senire PT100 Connection of Temperature Measuring nf 7 Mio) ' AUXsMe or nue woe | a | il Bo PT-100 2-Leiter I 2.wire connection with PT100 for PTT00 input Pi (Other PT100 inputs PT2 .. PT4 to be connected in same way) 07 08 09 ALT-01 PT-100 S.wire connection with PT100 for PTT0O Input PT? (Other PT100 inputs PT2.. PT4 to be connected in same way) ~ “Am-0101 \ 3-Leiter ! DGB-004-1.02 HIPASE Data Sheets Page 153 of 353, 12.6. Connection for Shield Grounding Connection for Shield Grounding (X1 /P1, P2 and X2/ P1, P2) Faston connection DIN 46942 6.95 X 0,8 Special witng recommendations Wire cross section Wire cross section AWG (keri) Page 154 of 353 2 groups with 2 faston male connectors each Fast-on female plug connector plug width: 6:38 mm plug thickness: 05mm 180° 1.0.1.5 mm stranded with ferule 17.15 stranded wit ferrule DGB-004-1.02 HIPASE Data Sheets ANORIZ Hydro 12.7. Connection diagram -[pe Block diagram with marked red coding pins on the socket as polarity protection / physical view of board cover plate at view to housing backside DGB-004-1.02 HIPASE Data Sheets Page 155 of 353, 12.8. Terminal assignment of terminal strip (X1, X2) x1/o1 x1oe x1/03 x10 x1/05 x1/08 x1o7 x1/08 x1/09 xino xn xia xia xine xan xine Page 156 of 353 au ant a2 ala als ala ptt PT pre Pre 01 01 02 02 Function ‘Analog Input 1+ /M Analg Int -/ 0 ‘Analog Input 2 + M4 Analg Input 2 -/ 0 Analog Int + ‘Analog Input 3 -/0V PT100 temperatura detection 1 +/ Me PT 100 temperature detcton 1 M- PT100 temperature tection 1 aux. votage- PT100 temperatura detection 2 +/ Me PT100 temperature detacton 2 M- PT100 temperature detection 2 aux. votage Analog Our 1 « Analog Output 1 Analog Ourpur2« ‘Analog Output 2 DGB-004-1.02 HIPASE Data Sheets ANORIZ Hydro cone Data point Function x2i01 ala Analog Input 4 +/ M x22 ala Analog Input 4 -/ 0V x203 als Analog Input 5+ / M x204 Als Analog Input 5 -/ 0V x2i05 Als Analog Input 6 +/ M x2i06 als Analog Input 6 -/0V x27 Pra PT100 temperature detacion 3 + / M+ x2i08 Pra PT100 temperature detection 3 M- x20 PT100 temperature detection 3 aux. voltage x20 PT! PT100 temperature detection 4 +/ M+ xan Pv PT100 tomporature dototion 4 M xane PT100 tomporature dotoction 4 aux. voltage xo oa ‘Analog Output 3+ xon4 40a ‘Analog Output 3 x26 fos Analog Output 4+ xen6 04 ‘Analog Output 4 12.9. _ Usage each application Excitation system (in combination with AB-310) ‘+ AIT. Ald for detection of phase currents of thyristor bridge A at current sharing, conductivity supervision of thyristors, ‘+ PT1, PT2 for detection of thyristor bridge temperature of thyristor bridge A ‘+ _A\4... Al6 for detection of phase currents of thyristor bridge B at current sharing, conductivity supervision of thyristors ‘+ PT3, PT4 for detection of thyristor bridge temperature of thyristor bridge 8 DGB-004-1.02 HIPASE Data Sheets Page 157 of 353 12.10. Mechanical terminal coding © Prevents inadvertent plugging of a terminal plug to a non-matching socket in the device. ‘* Protects against misconnections and damage to equipment and plant components. + Plugs and sockets are provided with a unique code pattern. Does not prevent incorrect plugging of a terminal plug to a neighboring module of same type in the device. S| CGB014 : :/- i aU ~ im im pce. MSE: | = Black areas indicate inserted coding pins on the socket (8) and the plug (S} 12.11. Accessories, Spare parts Nomination Material number Details Plug connector with train rot with two screws, Nominal curent: 12 A, Number of contacts: 18, pitch: $08 mm, Connection 195506. mothod: sorow torial, Color: bio (tly, ‘equipped at dolivory) Phoenix Contact FRONT-MSTB 2,5/16- ‘STF-5,08 BU - 1704588 12.12. Validity Document valid for hardware: Mat. No. CGB-014--, Product state: 00 Devices from V 1.00.00 support only application modules from version CGB-014- with product state 00. Page 158 of 353 DGB-004-1.02 HIPASE Data Sheets

You might also like