Product data sheet 3RV2021-1EA10

CIRCUIT-BREAKER SZ S0,
FOR MOTOR PROTECTION, CLASS 10,
A-REL. 2.8...4A,
N-REL. 52A SCREW CONNECTION,
STANDARD SW. CAPACITY

General technical data:


product brand name SIRIUS

Product designation 3RV2 circuit breaker

Size of the circuit-breaker S0

Size of contactor / can be combined / company-specific S00

Number of poles / for main current circuit 3

Product function

• Short circuit protection Yes

• overload protection Yes

• Phase failure detection Yes

• System protection Yes

• motor protection Yes

• motor protection with overload relay function No

• starter protection No

• Transformer protection No

• Disconnector functionality Yes

• Main switches with supply disconnect function and EM-STOP No


switches

Design of the operating mechanism selector switch

Product component

• Auxiliary switch No

3RV2021-1EA10 subject to modifications


Page 1/ 5 11/21/2014 © Copyright Siemens AG 2014
• undervoltage release No

• Trip indicator No

Product expansion

• Auxiliary switch Yes

• optional / motor drive No

Insulation voltage / with degree of pollution 3 / Rated value V 690

Surge voltage resistance / Rated value kV 6

Protection class IP

• of the terminal IP20

• on the front IP20

Protection against electrical shock finger-safe

Installation altitude / at height above sea level / maximum m 2,000

Relative humidity

• during operation % 10 … 95

Ambient temperature

• during transport °C -50 … +80

• during storage °C -50 … +80

• during operation °C -20 … +60

Shock resistance / acc. to IEC 60068-2-27 25g / 11 ms

Usage category

• acc. to IEC 60947-4-1 AC-3

Active power loss / total / typical W 6

Main circuit:
Operating current / Rated value A 4

Operating voltage / Rated value V 690

Type of voltage / for main current circuit AC/DC

Operating frequency

• Rated value Hz 50 … 60

Operating current / at AC-3 / at 400 V / Rated value A 4

Protective and monitoring functions:


Type of protection Increased safety

Certificate of suitability / ATEX Yes

Design of the overload circuit breaker thermal

Adjustable response value current / of the current-dependent A 2.8 … 4


overload release

Trip class CLASS 10

Design of the short-circuit trip magnetic

3RV2021-1EA10 subject to modifications


Page 2/ 5 11/21/2014 © Copyright Siemens AG 2014
Response value current / of the instantaneous short-circuit A 52
release

Operational short-circuit current breaking capacity (Ics) / with


AC

• at 240 V / Rated value kA 100

• at 400 V / Rated value kA 100

• at 500 V / Rated value kA 100

• at 690 V / Rated value kA 4

Maximum short-circuit current breaking capacity (Icu)

• with AC / at 240 V / Rated value kA 100

• with AC / at 400 V / Rated value kA 100

• with AC / at 500 V / Rated value kA 100

• with AC / at 690 V / Rated value kA 6

Breaking capacity short-circuit current (Icn)

• with 1 current path / for DC / at 150 V / Rated value kA 10

• with 2 current paths in series / for DC / at 300 V / Rated value kA 10

• with 3 current paths in series / for DC / at 450 V / Rated value kA 10

Installation/ mounting/ dimensions:


Mounting type screw and snap-on mounting onto 35 mm standard
mounting rail according to DIN EN 60715

mounting position any

Depth mm 96

Height mm 97

Width mm 45

Connections/ terminals:
Arrangement of electrical connectors / for main current circuit Top and bottom

Design of the electrical connection / for main current circuit screw-type terminals

Type of connectable conductor cross-section

• for main contacts

• single or multi-stranded 2x (1 ... 2,5 mm²), 2x (2,5 ... 10 mm²)

• finely stranded

• with core end processing 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm²

• for AWG conductors / for main contacts 2x (16 ... 12), 2x (14 ... 8)

UL/CSA ratings:
Operating voltage / acc. to UL 60947 / Rated value V 600

Full-load current (FLA) / for three-phase AC motor

• at 480 V / Rated value A 4

• at 600 V / Rated value A 4

3RV2021-1EA10 subject to modifications


Page 3/ 5 11/21/2014 © Copyright Siemens AG 2014
Certificates/ approvals:
General Product Approval Declaration of Test Certificates
Conformity

Special Test Type Test


Certificate Certificates/Test
Report

Shipping Approval

Shipping Approval other

Confirmation other Environmental


Confirmations

Further information:
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs

Industry Mall (Online ordering system)


http://www.siemens.com/industrymall

Cax online generator


http://www.siemens.com/cax

Service&Support (Manuals, Certificates, Characteristics, FAQs,...)


http://support.automation.siemens.com/WW/view/en/3RV2021-1EA10/all

Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...)
http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=3RV2021-1EA10

3RV2021-1EA10 subject to modifications


Page 4/ 5 11/21/2014 © Copyright Siemens AG 2014
last change: Nov 20, 2014

3RV2021-1EA10 subject to modifications


Page 5/ 5 11/21/2014 © Copyright Siemens AG 2014

You might also like