B 70
temperature. Apply the test current and maintain it until the temperature of the furnace in steps of approximately 100°C to
resistance of the specimen has become constant. Then increase room temperature. Take measurements at each point when
the current by 40 % and maintain it at this value until the temperature and resistance have become stationary. Note the
resistance has again become constant. If the change in resis- time at which each reading is taken. Define each point by the
tance is greater than 0.1 %, the test current is too large and shall mean of at least one pair of resistance readings for which the
be reduced until the foregoing limitations are reached. current through the sample has been reversed between read-
ings. This is necessary in order to eliminate the effects of
NOTE 1—In the case of nickel-chromium alloy 400°C is a suitable
temperature. thermal electromotive forces.
7.2 Determine the temperature by means of calibrated
6.2 The test current has a negligible effect on the resistance thermocouples, in conjunction with a potentiometer or pyrom-
measurement when the power lost in its passage through the eter of such construction as to ensure an accuracy correspond-
specimen is less than 0.01 W/cm2 of the effective free surface ing to a temperature uncertainty not exceeding 10°C.
of the specimen. For straight specimens and those which are so
coiled or bent that the distance between the adjacent convolu- 8. Temperature-Resistance Curve
tions is greater than five times the maximum transverse 8.1 Plot a curve showing the change of resistance with
dimension of the cross section of the specimen, consider the temperature using the final room-temperature resistance value
free surface to be that surface area of the portion of the as a base. Note the time interval between successive readings
specimen between the potential leads. When, as for the sake of on the curve sheet. Consider the curve thus obtained with
saving space in the furnace, the specimen is wound into a spiral descending temperature as defining the true temperature-
or helix, or bent back and forth upon itself in such a manner resistance characteristics of the material tested.
that the distance between adjacent convolutions is less than five
9. Singular Points
times the maximum transverse dimension of the cross section
of the specimen, consider the free surface to be that surface 9.1 If there are indications that the curve is not smooth at
area of the cylindrical or prismatic volume enclosing the coiled any point, carry the specimen through the temperature cycle
or convoluted specimen. Calculate the power loss due to the again, and take temperature and resistance readings at intervals
measuring current from the following equation: of approximately 25°C in the suspected region.
W 5 I 2 Rm 10. Precision and Bias
10.1 The reproducibility of the change in resistance with
where: temperature depends primarily on the uniformity of tempera-
W = power loss, W, ture of the sample and secondarily on the rate of temperature
I = measuring current A, and
decrease. For nickel-chromium alloys the faster the decrease in
Rm = resistance at maximum test temperature, V.
temperature, the lower the change in resistance.
10.2 The precision of this test method is within 62 %.
7. Procedure
10.3 The bias cannot be determined for reasons detailed in
7.1 Mount the test specimen in the furnace, bring the 10.1.
temperature of the furnace to the maximum specified tempera-
ture of test for the alloy in question, and hold at this value until 11. Keywords
the resistance of the specimen remains constant except for the 11.1 coefficient of resistance; heating elements; resistance
relatively slow changes due to oxidation. Then lower the change; resistors; temperature-resistance
ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned
in this standard. Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk
of infringement of such rights, are entirely their own responsibility.
This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and
if not revised, either reapproved or withdrawn. Your comments are invited either for revision of this standard or for additional standards
and should be addressed to ASTM International Headquarters. Your comments will receive careful consideration at a meeting of the
responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should
make your views known to the ASTM Committee on Standards, at the address shown below.
This standard is copyrighted by ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
United States. Individual reprints (single or multiple copies) of this standard may be obtained by contacting ASTM at the above
address or at 610-832-9585 (phone), 610-832-9555 (fax), or service@astm.org (e-mail); or through the ASTM website
(www.astm.org).