You are on page 1of 5

GENERAL NOTES:

1. DO NOT SCALE FROM THE DRAWINGS.


2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH OTHER
RELEVANT ARCHITECTURAL , STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
SPECIFICATIONS.

Rear Elevation
302

A B C D

S-01
A
5,730 230 3,730 13,730
300 250 300 50 230
230 1,800 800 600 600 800 1,000 1,500 1,000 1,000 1,500 8,500 1,500 1,000 230

3
230

230
1,725

1,600 150 1,800 150 1,800


2,500

±0
150

Min-supermarket
Lubricants shop
6,730
1,500

6,500
0FFICE

Right Elevation
Left Elevation
302

301
8,160
5,500 230 3,500 230 13,500 230
2,500

±0 ±0
230

230
2
Rev Description Drawn Checked Date
1,190
970

970
Location:

Proposed Petrol station to be


1 built at Kisiwani Vijibeni Kigamboni Dar es salaam
230

230
Plot No.........254....................
1,730 2,500 1,500 980 2,500 250 230 4,520 2,500 980 1,230 4,500 Block No....A........................
230 5,500 230 230 2,750 230 7,020 230 230 5,500 230
Client:
23,420
Names: Fahad Said Mohamed
PO. Box: .............
City: Dar es salaam, Tanzania
S-01

Email: -
A

301
Consultant:
Fron Elevation

Drawing title:

0. Ground Floor-Shops

Scale Drawn By: Checked By: Sheet no. Size


A. Mmasy
1:100 Date:
A3
Dec -2019
Dwg. Number Project. Number Rev

A.01.1
GENERAL NOTES:
1. DO NOT SCALE FROM THE DRAWINGS.
2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH OTHER
RELEVANT ARCHITECTURAL , STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
SPECIFICATIONS.

Rear Elevation
302

A B C D

S-01
A
5,730 3,730 13,730

3
6,730

Right Elevation
Left Elevation
302

301
2
1,190

1 Rev Description Drawn Checked Date

Location:

Proposed Petrol station to be


built at Kisiwani Vijibeni Kigamboni Dar es salaam
900 900 900 900 900 900 900 900 900 900 800 Plot No.........254....................
Block No....A........................

Client:
S-01
A
Names: Fahad Said Mohamed
PO. Box: .............
301 City: Dar es salaam, Tanzania
Fron Elevation Email: -

Consultant:

Drawing title:

1. Roof Plan-Shops

Scale Drawn By: Checked By: Sheet no. Size


A. Mmasy
1:100 Date:
A3
Dec -2019
Dwg. Number Project. Number Rev

A.01.2
GENERAL NOTES:
1. DO NOT SCALE FROM THE DRAWINGS.
2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH OTHER
RELEVANT ARCHITECTURAL , STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
SPECIFICATIONS.

1 2 3

IT4 roofing sheets color to be decided


2" x 2" purlins spaced at 350mm c/c
2" x 6" rafters spaced at 1500mm c/c

1,200
300

2" x 2" ceiling brandering at

700
12mm Tuff glass 60cm c/c
4" x 6" Pergola spaced at 900mm c/c Gypsum ceiling board

300
Min-supermarket
3,500
3,600

Rev Description Drawn Checked Date

2,500
Location:

Proposed Petrol station to be


built at Kisiwani Vijibeni Kigamboni Dar es salaam
Plot No.........254....................
100mm mass concrete 230mm block wall
Block No....A........................
floor reinforced by BRC
Client:

Names: Fahad Said Mohamed


PO. Box: .............
City: Dar es salaam, Tanzania
Email: -

Consultant:

230mm Foundation block wall


-FINISHES AS SPECIFIED
-4-6CM THICK SAND FILLING
-R.C.C FLOOR SLAB AS STRU.DRAWING
-COMPACTED SOIL
Drawing title:

S-01 A-Shops

Scale Drawn By: Checked By: Sheet no. Size


A. Mmasy
1:50 Date:
A3
Dec -2019
Dwg. Number Project. Number Rev

A.02.1
GENERAL NOTES:
A B C D 1. DO NOT SCALE FROM THE DRAWINGS.
2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH OTHER
RELEVANT ARCHITECTURAL , STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
SPECIFICATIONS.

1,500
1,000

1,000
1,000

1,000

3,500
2,500

2,500

301 Fron Elevation


- 1:75

1 2 3
Rev Description Drawn Checked Date

Location:

Proposed Petrol station to be


built at Kisiwani Vijibeni Kigamboni Dar es salaam
1290

Plot No.........254....................

600
Block No....A........................

Client:
210

400

Names: Fahad Said Mohamed


PO. Box: .............
City: Dar es salaam, Tanzania
Email: -
3,500
3,600

Consultant:

Drawing title:

301 Fron Elevation-Shops

Scale Drawn By: Checked By: Sheet no. Size


A. Mmasy
301 Right Elevation
1:75 Date:
Dec -2019
A3

- 1:75
Dwg. Number Project. Number Rev

A.03.1
GENERAL NOTES:
1. DO NOT SCALE FROM THE DRAWINGS.
2. THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH OTHER
RELEVANT ARCHITECTURAL , STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS AND ALL RELEVANT SECTIONS OF THE
SPECIFICATIONS.

D C B A

600
2,000

2,000

2,000

2,500

1,900
500

500

500
302 Rear Elevation
- 1:75

3 2 1
Rev Description Drawn Checked Date

Location:

Proposed Petrol station to be


built at Kisiwani Vijibeni Kigamboni Dar es salaam

500
Plot No.........254....................
Block No....A........................

1,000
Client:

Names: Fahad Said Mohamed


PO. Box: .............
City: Dar es salaam, Tanzania
Email: -

Consultant:

3,600
2,000
500

Drawing title:

302 Rear Elevation-Shops

Scale Drawn By: Checked By: Sheet no. Size


A. Mmasy
1:75 Date:
A3
302 Left Elevation
Dec -2019
Dwg. Number Project. Number Rev

- 1:75 A.03.4

You might also like