Front-Loading Automatic Washer

PRODUCT MODEL NUMBERS OVERALL DIMENSIONS


NFW7300W Washer dimensions Custom undercounter installation-washer only
27" 2" (50 mm)
501/4" (686 mm)
Electrical: A 120 volt, 60 Hz., AC only, 15- or 20-amp, (1276 mm)
fused electrical supply is required. A time-delay fuse
or circuit breaker is recommended. It is recommended
that a separate circuit serving only this washer be 36" min.
provided. (914 mm)
36"
(914 mm)
Drain System Options
1" 27" 1"
Standpipe drain system - wall or floor (views A & B) (25 mm) (686 mm) (25 mm)
The standpipe drain requires a minimum diameter
standpipe of 2" (50 mm). The minimum carry-away
301/2"
capacity can be no less than 17 gal. (64 L) per minute. (775 mm)

The top of the standpipe must be at least 30" (762 mm)


high and no higher than 96" (2.4 m) from the bottom
of the washer. For closet installation, with a door, the minimum ventilation openings in the top
and bottom of the door are required. Louvered doors with equivalent air ventilation
openings are acceptable.
A. B.
Recessed or closet installation - Washer on pedestal

3"
30" min. (76 mm) 38" min.
(762 mm) (965 mm)
48 in.2
48" (310 cm2)
(1220 mm)

Laundry tub drain system (view C)


The laundry tub needs a minimum 20 gal. (76 L) 24 in.2
capacity. The top of the laundry tub must be (155 cm2) 3"
(76 mm)
at least 30" (762 mm) above the floor.
1" 301/2" 4" 1" 27" 1" 1" 301/2" 4"
(25 mm) (775 mm) (102 mm) (25 mm) (686 mm) (25 mm) (25 mm) (775 mm) (102 mm)
Floor drain system (view D)
The floor drain system requires a siphon break that A B A B
may be purchased separately. See “Tools and Parts.” A - Recessed area A - Side view - closet or confined area
B - Side view - closet or confined area B - Closet door with vents

The siphon break must be a minimum of 28" (710 mm) Recessed or closet installation - Stacked washer and dryer
from the bottom of the washer. Additional hoses might
be needed.

48 in.2*
(310 cm2) 3"
(76 mm)
28" min.
30" min. (710 mm)
(762 mm)
3"
(76 mm)
*** Min. top and bottom air openings
24 in.2* for closet door.
C. D.. (155 cm2) *** External exhaust elbow requires
additional space.
1" (25 mm)
*** Wall, door and floor molding may
require additional spacing.
For cabinet installation, with a door, the minimum 12" (305 mm)
ventilation openings in the top are required.
7"
(178 mm) 7"
(178 mm)

72"
9" (1829 mm)
(229 mm)

1"
4" 311/2" 1" 27" (25 mm) 51/4"** 1"*** 27" 1"***
(102 mm) (800 mm) (25 mm) (686 mm) (25 mm)
(133 mm) (25 mm) (686 mm)
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation Ref. W10252719
our products, we reserve the right to change materials and specifications without notice. Instructions packed with product. Specifications subject to change without notice. 06/2010