2 TPU 4X . X X INDOOR SUPPORTING CURRENT TR ANSFORMERS

Parameters Units

Highest voltage for equipment 3.6 - 12 kV

Power frequency test voltage, 1 min. 10 - 42 kV

Lighting impulse test voltage 40 - 95 kV

Rated primary current 10 - 3 200 A

Rated short-time thermal current 2 - 100 kA/ 1s

Reconnectable (primary till 400-800 A) primary or


secondary

Description Technical data


The TPU 4x.xx transformers are cast in epoxy The transformer can be mounted in any position.
resin and designed for insulation voltages up to The transformer body is fixed by using four
12 kV. The 3.6 kV and 7.2 kV versions have the screws. Earth clamp M8 is on the transformer
same dimensions as the 12 kV. For certain types base plate.
of panels there is a need for extra long creepage
distance on the transformers. For this purpose Rated primary voltages
you can order current transformers with „ribs on 3.6 kV; 7.2 kV; 12 kV
the top”. The transformers are manufactured in
conformity with dimensions stated hereunder. Rated primary currents
The TPU 4x.xx transformers are designed as sin- 10; 15; 20; 25; 30; 40; 50; 60; 75; 100; 150; 200;
gle-turn or multi-turn versions, with one trans- 300; 400; 500; 600; 750; 1 000; 1 250; 1 500;
former ratio or with double ratio having the pos- 2 000; 2 500; 3 000 and 3 200 A; primary recon-
sibility to be reconnectable on the primary or on nectable modification max till 400-800 A. Other
the secondary side. The number of secondary primary currents can also be agreed upon with
windings (from 1 to 6 – max. 12 secondary termi- the customer.
nals - 2 rows), depends on the combination of the
technical parameters (such as the accuracy class, Rated secondary currents
burden, short-circuit current, overcurrent fac- 5 A; 1 A, others on request (possibility to combine
tor…) and the transformer dimensions size. different values in one transformer)

When agreed between the manufacturer and the Accuracy classes


customer the TPU transformers can be provided 0.2; 0.2S; 0.5; 0.5S; 1; 3; 5; 5P10; 5P15; 5P20; 10P10;
with the voltage indication system. For this pur- 10P15; 10P20; others on request.
pose, however, it is necessary to know in what in-
sulation level the transformers shall operate. The Rated frequency
secondary windings are used for measurement or 50 Hz or 60 Hz, others on request
protection purposes, or for special use (testing
winding, „X” class windings). One terminal of each The transformers are designed and manufactured
secondary winding used and one terminal of in conformity with the following standards and
short-circuited and not used winding have to be recommendations: IEC, VDE, ANSI, BS, GOST and
earthed during the transformer operation. The CSN, others on request.
secondary windings are lead out into a cast-type
secondary terminal box with plastic cover. The Cantilever strength
terminal cover is sealable. The terminals are pro- 5 kN
vided with M5 screws for the termination and
with throughgoing holes for direct earting (first Permissable torques for screw connections
row of secondary terminals).
M5 max 3.5 Nm min 2.8 Nm

M8 max 20 Nm min 16 Nm

M12 max 70 Nm min 56 Nm


3


01 Marking of current Code designation - TPU current transformers
transformer outlets -
example TPU x x . x x
a Single-core design
b Double-core design voltage current dimension primary terminals
c Three-core design
d Single-core design,
4….up 0… to 600 A multiturn 1..short 148 mm, DIN 1..no pr.rec., no ribs /40x80mm, 80x80mm/
reconnectable on the
secondary side
to 12 kV 1... to 1 250 A, combi 2..long 148 mm, DIN 2..prim. rec., no ribs /40x80mm, 80x80mm/
e Double-core design, multiturn, singleturn* 3..short, wide.. 184 mm 3..no pr.rec., with ribs /60x68mm, 80x80mm/
reconnectable on the 3…to 1 250 A singleturn 4..long, wide…184 mm 4..prim. rec., with ribs /40x80mm, 80x80mm/
secondary side 4…to 1 500 A singleturn 5..middle 148 mm, DIN
f Double-core design, 5…to 2 000 A singleturn
reconnectable on the 6…to 2 500 A singleturn
primary side 7…to 3 000 A singleturn
8…to 3 200 A singleturn

02 1 Secondary terminal
box (3 secondaries and * TPU 41.41 and TPU 41.43 only
voltage indicator)


03 2 Secondary terminal
box (2 secondaries and
grounding screw)

a b c

d e f


01

Standartized insulation levels of TPU 4x.xx transformers


3.6 / 21 / 45 kV 7.2 / 27 / 60 kV 12 / 28 / 75 kV
3.6 / 10 / 40 kV 7.2 / 20 / 60 kV 12 / 35 / 75 kV
12 / 42 / 95 kV

— —
02 03
4 TPU 4X . X X INDOOR SUPPORTING CURRENT TR ANSFORMERS

Dimensional Drawings

— —
TPU40.11
TPU 40.11 WEIGHT: 20-24kg
Weight: 20-24kg TPU40.12
TPU 40.12 WEIGHT: 19-25kg CREEPAGE
Weight: 19-25kg
TPU 43.11
TPU 43.11
CREEPAGE DISTANCE: mm
Creepage distance: mm Creepage distance: 215 mm
DISTANCE: 215mm

266 266

2
2

220

220
Pg16 14 Pg16 14

M8 M8
38

38
28

28
20

20
25 25
4

4
32 120 32
32 120 32
12

12
23 23 23
12

12

39,5
125

125
148

125

125
148
107

107
40

20 M12 M8 M12
80 135 80,5 135
10 270 15 10 270 15
335 335

Drawing n. Polarity Drawing n. Polarity


44614000 P1 to secondary terminal 44614020 P1 to secondary terminal
44614010 P2 to secondary terminal 44614030 P2 to secondary terminal

— —
TPU40.13
TPU 40.13 WEIGHT: 20-24kg CREEPAGE
Weight: 20-24kg TPU40.14
TPU 40.14 WEIGHT: 19-25kg CREEPAGE
Weight: 19-25kg
TPU 43.13 DISTANCE: 214mm DISTANCE: 215mm
TPU 43.13 Creepage distance: 214mm Creepage distance: 201mm
266
266 253
253
2
2

248
220
248
220

Pg16 14
Pg16 14
M8
M8
38
28

20
38
28

20

25
4

25 32 120 32
4

12

23 23 23
32 120 32
12
12
12

39,5
125

125
148
107

86
125

125
148
107

60
86

M8 M12
18 M12 80,5 135
68 135
10 270 15
10 270 15 335
335

Drawing n. Polarity Drawing n. Polarity


44614040 P1 to secondary terminal 44614060 P1 to secondary terminal
44614050 P2 to secondary terminal 44614070 P2 to secondary terminal
5

— —
TPU40.21
TPU 40.21 WEIGHT: 29-37kg CREEPAGE
Weight: 29-37kg TPU40.22
TPU 40.22 WEIGHT: 29-37kg CREEPAGE
Weight: 29-37kg
TPU 43.21
TPU 43.21
DISTANCE: 201mm
Creepage distance: 201mm
DISTANCE: 215mm
Creepage distance: 215mm

386 386

2
220

220
Pg16 14 Pg16 14

M8 M8
38

38
28

28
20

20
25 25
4

4
32 120 32 32 120 32
23 23 23
12

12
12

12

39,5
125

125
148

125

125
148
107

107
40

20 M12 M8 M12
80 255 80,5 255
10 390 15 10 390 15
455 455

Drawing n. Polarity Drawing n. Polarity


44614080 P1 to secondary terminal 44614100 P1 to secondary terminal
44614090 P2 to secondary terminal 44614110 P2 to secondary terminal

— —
TPU40.23
TPU 40.23 WEIGHT: 29-37kg CREEPAGE
Weight: 29-37kg TPU40.24
TPU 40.24 WEIGHT: 29-37kg CREEPAGE
Weight: 29-37kg
TPU 43.23 DISTANCE: 214mm DISTANCE: 215mm
TPU 43.23 Creepage distance: 214mm Creepage distance: 215mm

386 386
282 282
2

2
248

248
220
220

Pg16 14 Pg16 14

M8 M8
38

38
28

28
20

20

25 25
4

32 120 32
32 120 32 23 23 23
12

12
12

12

39,5
125

125
148

125

125
148
107

107
60
86

86

18 M12 M8 M12
68 255 80,5 255
10 390 15 10 390 15
455 455

Drawing n. Polarity Drawing n. Polarity


44614120 P1 to secondary terminal 44614140 P1 to secondary terminal
44614130 P2 to secondary terminal 44614150 P2 to secondary terminal
6 TPU 4X . X X INDOOR SUPPORTING CURRENT TR ANSFORMERS

— —
TPU40.31
TPU 40.31 WEIGHT: 31-39kg CREEPAGE
Weight: 31-39kg TPU40.33
TPU 40.33 WEIGHT: 31-39kg CREEPAGE
Weight: 31-39kg
TPU 43.31
TPU 43.31 Creepage distance: 215mm
DISTANCE: 215mm TPU 43.33
TPU 43.33 Creepage distance: 215mm
DISTANCE: 215mm
285
255

285

280
220

220
Pg16 14
Pg16 14
M8
M8
38
28

20

38
28

20
25
4

32 120 32
25
12
12

4
32 120 32

12
12
160

160
184
107

60

160

160
184
107

110
60
18 M12
68 135 18 M12
10 270 25 68 135
355 10 270 25
355

Drawing n. Polarity Drawing n. Polarity


44614160 P1 to secondary terminal 44614180 P1 to secondary terminal
44614170 P2 to secondary terminal 44614190 P2 to secondary terminal

— —
TPU40.41
TPU 40.41 WEIGHT: 45-55kg CREEPAGE
Weight: 45-55kg TPU40.43
TPU 40.43 WEIGHT: 45-55kg CREEPAGE
Weight: 45-55kg
TPU 43.41 DISTANCE: 215mm TPU 43.43 DISTANCE: 215mm
TPU 43.41 Creepage distance: 215mm TPU 43.43 Creepage distance: 215mm
395
280

395
2

280
220

220

Pg16 14 Pg16 14

M8 M8
38

38
28

28
20

20

25
4

25
4

32 120 32 32 120 32
12
12
12

12
160

160
184

160

160
184
107

107

110
60

60

M12 18 M12
68 255 68 255
10 390 15 10 390 15
465 465

Drawing n. Polarity Drawing n. Polarity


44614200 P1 to secondary terminal 44614220 P1 to secondary terminal
44614210 P2 to secondary terminal 44614230 P2 to secondary terminal
7

— —
TPU40.53
TPU 40.53 WEIGHT: 28kg CREEPAGE
Weight: 28kg TPU44.11
TPU 44.11 WEIGHT: 25-31kg CREEPAGE
Weight: 25-31kg
TPU 43.53 DISTANCE: 214mm TPU 45.11 DISTANCE: 201mm
TPU 43.53 Creepage distance: 214mm TPU 45.11 Creepage distance: 201mm
TPU 46.11
283 TPU
TPU46.11
47.11
258
TPU47.11
TPU 48.11
TPU 48.11 266

2
248
220

220
Pg16 14 M8
Pg16 14

64
M8
38
28

20

38
25

28

20
4

32 120 32
12

25
12

4
32 120 32

12

12
125

107

125
148
60
86

125

125
148
107

40
80
18 M12
68 135 15
20 M12
10 270 80 135
335
10 270 15
335

Drawing n. Polarity Drawing n. Polarity


1VL4600921R0101 P1 to secondary terminal 44614240 P1 to secondary terminal
1VL4600921R0102 P2 to secondary terminal 44614250 P2 to secondary terminal

— —
TPU44.13
TPU 44.13 WEIGHT: 25-31kg CREEPAGE
Weight: 25-31kg TPU44.21
TPU 44.21 WEIGHT: 40-45kg CREEPAGE
Weight: 40-45kg
TPU 45.13 DISTANCE: 201mm TPU 45.21 DISTANCE: 201mm
TPU 45.13 Creepage distance: 201mm TPU 45.21 Creepage distance: 201mm
TPU 46.13 TPU 46.21
TPU
TPU46.13
47.13 TPU
TPU46.21
47.21
266
TPU47.13
TPU 48.13 250 TPU47.21
TPU 48.21
TPU 48.13 TPU 48.21
386
2
2

280

220

Pg16 14
220

Pg16 14 M8
38

M8
28

20

25
4

32 120 32
38
28

20

12
12

25 32 120 32
4
12

12

125

125
148
107

40
80
125

125
148
107

40
80
90

20 M12
80 255
10 390 15
455
20 M12
80 135
10 270 15
335

Drawing n. Polarity Drawing n. Polarity


44614260 P1 to secondary terminal 44614280 P1 to secondary terminal
44614270 P2 to secondary terminal 44614290 P2 to secondary terminal
8 TPU 4X . X X INDOOR SUPPORTING CURRENT TR ANSFORMERS

— —
TPU44.23
TPU 44.23 WEIGHT: 40-45kg CREEPAGE
Weight: 40-45kg TPU44.31
TPU 44.31 WEIGHT: 34-42kg CREEPAGE
Weight: 34-42kg
TPU 45.23
TPU 45.23
DISTANCE: 201mm
Creepage distance: 201mm
TPU 45.31
TPU 45.31 Creepage distance: 210 mm
DISTANCE: 210mm

TPU 46.23 TPU 46.31


TPU
TPU46.23
47.23 TPU
TPU46.31
47.31
TPU47.23
TPU 48.23 TPU47.31
TPU 48.31
TPU 48.23 386 TPU 48.31 285
280

2
2

220
280
Pg16 14

220
M8
Pg16 14

M8

38
28

20
38

25
28

4
32 120 32
20

12
12
25
4

32 120 32
12

12

160

160
184
107
125

125
148
107

40
80
40
80
90

20 M12
80 255
10 390 15 20 M12
455 80 135
10 270 25
355

Drawing n. Polarity Drawing n. Polarity


44614300 P1 to secondary terminal 44614320 P1 to secondary terminal
44614310 P2 to secondary terminal 44614330 P2 to secondary terminal

— —
TPU44.33
TPU 44.33 WEIGHT: 34-42kg CREEPAGE
Weight: 34-42kg TPU44.41
TPU 44.41 WEIGHT: 46-58kg CREEPAGE
Weight: 46-58kg
TPU 45.33 DISTANCE: 210mm TPU 45.41 DISTANCE: 210mm
TPU 45.33 Creepage distance: 210mm TPU 45.41 Creepage distance: 210mm
TPU 46.33 285 TPU 46.41
TPU
TPU46.33
47.33 255 TPU
TPU46.41
47.41
TPU47.33
TPU 48.33 TPU47.41
TPU 48.41
TPU 48.33 TPU 48.41 395
2

2
280

220
220

Pg16 14
Pg16 14
M8

M8
38
28

20
38

25
4
28

20

25 32 120 32
12
12

32 120 32
4
12
12

160

160
184
107

40
80
160

160
184
107

110
40
80

20 M12
80 255
10 390 15
20 465
M12
80 135
10 270 25
355

Drawing n. Polarity Drawing n. Polarity


44614340 P1 to secondary terminal 44614360 P1 to secondary terminal
44614350 P2 to secondary terminal 44614370 P2 to secondary terminal
9


TPU44.43
TPU 44.43 WEIGHT: 46-58kg CREEPAGE
Weight: 46-58kg
TPU 45.43
TPU 45.43
DISTANCE: 210mm
Creepage distance: 210mm
TPU 46.43
TPU
TPU46.43
47.43
TPU47.43
TPU 48.43
TPU 48.43 395
280

280
220
Pg16 14

M8
38
28

20

25
4

32 120 32
12
12
160

160
184
107

110
40
80

20 M12
80 255
10 390 15
465

Drawing n. Polarity
44614380 P1 to secondary terminal
44614390 P2 to secondary terminal
— —
C O N TA C T U S NOTE We reserve all rights in this document and in
1VLC000501 Rev.9, en 2019.02.22

ABB s.r.o. We reserve the right to make technical the subject matter and illustrations con-
EPDS Brno changes or modify the contents of this docu- tained therein. Any reproduction, disclosure
Videnska 117, 619 00 Brno, ment without prior notice. With regard to to third parties or utilization of its contents -
Czech Republic purchase orders, the agreed particulars shall in whole or in parts - is forbidden without
Tel.: +420 547 152 021 prevail. ABB does not accept any responsibil- prior written consent of ABB.
+420 547 152 854 ity whatsoever for potential errors or possi-
Fax: +420 547 152 626 ble lack of information in this document. Copyright© 2019 ABB
E-mail: kontakt@cz.abb.com All rights reserved

www.abb.com

You might also like