BATTERY CHARGERS FOR THE AMERICAN MARKET

TL EQUALIZER Single-phase

Single-phase ferroresonant battery charger • Front panel with LED’s.

Technical features:

• Single-phase input supply 120/208/240 VAC – Frequency 50/60Hz.


• Different power supply voltages available on request.
• New electronic controller with AP070 card with microprocessor. 4 LEDs signalling the
charge status or possible faults.
• Lab-tested electronic circuit conforming to Directive on Electromagnetic Compatibility
and CE marking.
• 12/24/36 V rated voltages adjustable by jumpers and with 2.40V/cell automatic
threshold setting.
• Time-controlled gas charging phase, adjustable by DIP switch (3 hours as standard).
• Foreseen charging time: 8÷9 hours (without Equalizing charge).
• The Equalizing charge is automatically performed 60 minutes after the last charge
cycle.
• The normal charge and the Equalizing charge will be performed for 16 hours max.
• DIP switches to select and adjust the charging parameters:
1. Autostart
2. Final charge time
3. Quick test
4. Equalizing charge
5. Proportional charge
6. Charge reset due to battery disconnection

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT
MATIC POINT Single-phase

Single-phase battery charger with Wa charging characteristic • Digital display with readout of charging data.

Technical features:

• Single-phase input supply 120/208/240 VAC – Frequency 50/60Hz.


• Different power supply voltages available on request.
• New electronic controller with AP735W card with microprocessor.
• New Software with Ah-control of the charging process.
• Polycarbonate plate with symbols easy and immediate to interpret.
• Complete switching off of charger, if it is disconnected from battery during the
charging process.
• Charging with decreasing current until a voltage of 2.40V/cell is reached and the gas
charging phase begins (adjustable).
• Time-controlled gas charging phase, adjustable by DIP switch (3 hours as standard).
• Foreseen charging time: 8÷9 hours (without Equalizing charge).
• The Equalizing charge is automatically performed 60 minutes after the last charge
cycle.
• The normal charge will be performed for 12 hours max.
• LEDs signalling the charging stages of failures, if any.
• Four-digit LCD with 12 multifunctional symbols displaying the charging data recalled
by pushing the ON/OFF button:
1. current delivered in real time
2. instantaneous voltage at battery terminals
3. initial battery voltage at the beginning of charging process
4. end of charge battery voltage

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT
5. current at the beginning of the charging process
6. current at the end of charging process
7. delivered ampere-hours
8. overall charging time
• The following charging parameters can be programmed by means of DIP
switches/jumpers:
1. Autostart
2. Final charge time
3. Safety timer
4. Equalizing charge
5. Proportional charge

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT
POWER POINT Single-phase

Single-phase ferroresonant battery charger.

Technical features:

Single-phase input supply: 208/240/480 VAC - Frequency 50/60 Hz.

Different power supply voltages available on request.

Transformer adjustments to ±5% VAC.

Tropicalized stray-flux transformer, copper windings with double enamel insulation, class
H, impregnated with non-toxic resins, kiln-dried.

Transformer with UL recognized insulation system which ensures high reliability even in
difficult operating conditions.

Low voltage control circuit (24 VAC).

Overload cutout on transformer.

Rectifier bridge equipped with interference suppressing filters.

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT
Protection fuses on mains input and D.C. output.

Final acceptance test conforming to safety regulations.

Complete with charging cables and battery connectors.

Power cord to be installed by the customer.

It can be stacked up to three units high.

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT
POKER Single-phase

Multivoltage ferroresonant battery charger.

Technical features:

• Mains input: 120V AC ±5%, UL-listed 20A input fuse.


• Input Current: 15A AC max. Equipped with NEMA 5- 15A cables.
• Output: suitable for 12V, 24V, 36V, and 48V lead-acid batteries.

Electromechanical timer adjustable from 0 to 12 hours max.

Electromechanical switch for output voltages selection.

Ammeter: 100A/100mV.

Cabinet with wheels and handlebar for easy handling.

24V AC auxiliary circuit with overload cut-out and 1.6A fuse.

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT
POWER POINT Three-phase

Three-phase ferroresonant battery charger.

Technical features:

Three-phase input supply: 208/240/480/600 VAC - Frequency 50/60 Hz.

Different power supply voltages available on request.

Transformer adjustments to ±5% VAC.

Tropicalized stray-flux transformer, copper windings with double enamel insulation, class
H, impregnated with non-toxic resins, kiln-dried.

Transformer with UL recognized insulation system which ensures high reliability even in
difficult operating conditions.

Low voltage control circuit (24 VAC).

Overload cutout on transformer.

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT
Rectifier bridge equipped with interference suppressing filters.

Protection fuses on mains input and D.C. output.

Final acceptance test conforming to safety regulations.

Complete with charging cables and battery connectors.

Power cord to be installed by the customer.

It can be stacked up to three units high.

63 McIntyre Place Unit 7 & 14 Kitchener, Ontario N2R 1J5 Canada


Tel: 519-748-2287 Fax: 519-748-2297
NEW, USED & REBUILT PARTS – MATERIAL HANDLING EQUIPMENT