Professional Documents
Culture Documents
Omega
Yanmar diesel powered attenuated generator sets, designed and assembled on a heavy duty base in a rugged attenuated canopy provide reliable smooth uninterrupted power for long periods of operation in all conditions.
Construction Features
Constructed to QA Std ISO 9001 Heavy Duty Steel Base Frame Large Capacity, 24 hr Base Fuel Tank Canopy Enclosure in Cold Rolled Steel Fire Retarded Sound Insulation Sound level 70-75 dB(A) @ 7M Powder Paint Finish Stainless Steel Locks and Hinges Engine Fluid Spill Containment Area Resilient Anti-Vibration Mounts Forklift Access Points Waste Oil Drain Pump External Diesel Fuel Filling Point Internally Installed Maintenance Light High Impedance Type Exhaust Silencer Maintenance Free Lead Acid Battery Battery Isolator Switch Battery Isolator Lock Out Lever Assembly External Emergency Stop Button Control Panel Analogue Instrumentation A/C Generator Frequency (Hz) A/C Generator Volts A/C Generator Amps A/C Outlet Distribution Moulded Case Main Circuit Breaker Switched Outlet Sockets 1 x 15A and 32A, 500V, 5 pin (3 Ph set) 2 x 15A, 250V (1 Ph set) Outlets Circuit Breakers RCD Protection / Single Phase
Alternator Features
Stamford industrial alternators are manufactured to QA level BS EN ISO 9001 and meet the requirements of BS EN 60034 and the relevant sections of the international standards such as BS 5000, VDE 0530, NEMA MGI-32, IEC 34, CSA C22.2-100 and AS1359 Rated Voltage, 415V and 240V Rated Frequency 50 Hz Single Bearing, Brushless Insulation Class H Protection Rating IP23 AVR Regulation 1.0% Voltage Fluctuation below 0.5% Frequency Fluctuation below 0.5% Phone Interference THF<2%
Performance Data
Model AP6YA-1 AP8YA-1 AP10YA-1 AP13YA-1 AP15YA-1 AP18YA-1 AP21YA-1 AP34YA-1 AP42YA-1 Prime kVA kWe 6.0 8.4 10.5 13.3 15.0 17.9 20.8 34.4 42.8 4.8 6.7 8.4 10.6 12.0 14.3 16.6 27.5 34.2 Standby kVA kWe 6.5 9.3 11.6 14.5 17.0 19.5 23.1 38.8 47.3 5.2 7.4 9.3 11.6 13.6 15.6 18.5 31.0 37.8 Engine Model 3TNV70 GGE 3TNV76 GGE 3TNV82A GGE 3TNV88 GGE 3TNV84T GGE 4TNV88 GGE 4TNV84T GGE 4TNV98 GGE 4TNV98T GGE Cyl (L) 0,85 1,11 1,33 1,64 1,49 2,19 1,99 3,31 3,31
Performance Data
Model AP6YA-3 AP8YA-3 AP10YA-3 AP12YA-3 AP15YA-3 AP17YA-3 AP20YA-3 AP33YA-3 AP42YA-3 Prime kVA kWe 5.8 8.1 9.9 12.5 14.8 17.4 20.5 33.5 41.9 4.6 6.5 7.9 10.0 11.8 13.9 16.4 26.8 33.5 Standby kVA kWe 6.2 9.0 11.0 13.8 16.8 19.0 22.9 37.5 46.3 5.0 7.2 8.8 11.0 13.4 15.2 18.3 30.0 37.0 Engine Model 3TNV70 GGE 3TNV76 GGE 3TNV82A GGE 3TNV88 GGE 3TNV84T GGE 4TNV88 GGE 4TNV84T GGE 4TNV98 GGE 4TNV98T GGE
PRP: Prime Power is available for an unlimited number of annual operating hours with variable load applications, in accordance with ISO8528-1. A 10% overload capability is available for a period of 1 hr within 12 hr period of operation in accordance with ISO3046-1. LTP: Standby Power is applicable for suppling emergency power in variable load applications for up to 200 hrs per annum in accordance with ISO8528-1. Overload not applicable. AC electrical ratings are calculated using Power Factor of 0.8 Rating in accordance to ISO 3046 - 25C ambient temperature, 100 kPa atmospheric pressure and 30% RH.
PO Box 1156 Booragoon Western Australia 6954 121 Dowd Street Welshpool Western Australia 6106 Telephone +61 08 9356 6088 Fax +61 08 9356 6022 sales@dieselsplus.com.au
Manufactures specifications, materials and features are intended as a guide and are subject to changes without notice.