You are on page 1of 20

Continuous Renal Replacement Therapy in the Adult Intensive Care Unit: History and Current Trends

Susan Dirkes and Kimberly Hodge


Crit Care Nurse 2007;27:61-80
2007 American Association of Critical-Care Nurses Published online http://www.cconline.org Personal use only. For copyright permission information: http://ccn.aacnjournals.org/cgi/external_ref?link_type=PERMISSIONDIRECT

Subscription Information http://ccn.aacnjournals.org/subscriptions/ Information for authors http://ccn.aacnjournals.org/misc/ifora.shtml Submit a manuscript http://www.editorialmanager.com/ccn Email alerts http://ccn.aacnjournals.org/subscriptions/etoc.shtml

Critical Care Nurse is the official peer-reviewed clinical journal of the American Association of Critical-Care Nurses, published bi-monthly by The InnoVision Group 101 Columbia, Aliso Viejo, CA 92656. Telephone: (800) 899-1712, (949) 362-2050, ext. 532. Fax: (949) 362-2049. Copyright 2007 by AACN. All rights reserved.

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

ClinicalArticle

Continuous Renal Replacement Therapy in the Adult Intensive Care Unit


History and Current Trends
Susan Dirkes, RN, MSA, CCRN Kimberly Hodge, RN, CCRN-CMC

cute renal failure (ARF) is a common complication in critically ill adult patients in critical care units.

This article has been designated for CE credit. A closed-book, multiple-choice examination follows this article, which tests your knowledge of the following objectives: 1. Identify indications for intermittent dialysis and continuous renal replacement therapy (CRRT) 2. Review variations and advantages and disadvantages of CRRT 3. Examine potential complications of CRRT

ARF is defined as a sudden decline or cessation of renal function. Characteristics include inability of the kidneys to excrete wastes and maintain fluid, electrolyte, and acid-base balance.1,2 Despite advances in treatment, data from the past several decades continue to indicate that ARF still is associated with high mortality rates, ranging from 25% to 90%.3,4 Factors that may influence the rates include the increasing age of patients and the existence of comorbid conditions (eg, diabetes, preexisting renal disease, vascular disease).1 Historically, the treatment of ARF has been supportive. The primary Authors

focus of intermittent hemodialysis is to replace renal function by removing excess water and wastes. The standard of care for patients treated with intermittent hemodialysis may not be applicable to critical care patients because of the nature of the latter patients illness and catabolic state, the presence of systemic inflammatory syndrome with or without sepsis, and other organ failure.5 In this article, we review treatment of ARF in critically ill patients, indications for intermittent hemodialysis and continuous renal replacement therapy (CRRT), and the use of other variations of CRRT currently under investigation.

Susan Dirkes is a clinical educator at NxStage Medical, Lawrence, Mass. Kimberly Hodge is the Advanced Cardiac Life Support and Pediatric Advanced Life Support senior educator for the Emergency Response Training Institute at Clarian Health, Indianapolis, Ind.
Corresponding author: Susan Dirkes, 6326 Sterling Dr, Newport, MI 48166 (e-mail: sdirkes@umich.edu). To purchase electronic or print reprints, contact The InnoVision Group, 101 Columbia, Aliso Viejo, CA 92656. Phone, (800) 809-2273 or (949) 362-2050 (ext 532); fax, (949) 362-2049; e-mail, reprints@aacn.org.

Management of ARF
Medications ARF can be managed in some patients by nondialytic interventions such as loop diuretics (furosemide and bumetanide). Recently, the effect of diuretics in critically ill patients

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 61


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

with ARF has been questioned. Mehta et al6 and Shilliday et al7 found that the use of diuretics in critically ill patients with ARF was associated with an increased risk of death and nonrecovery of renal function. If medications are not effective, the choice of treatment and dialytic therapy should ideally mimic the efficacy of the native kidney and, at the same time, not delay the recovery of renal function. Therapy should be individualized according to each patients urgency and need for the therapy and hemodynamic tolerance. Intermittent Hemodialysis Intermittent hemodialysis is still a commonly used treatment for ARF in the critical care unit for some patients. The dialysis is typically done 3 times a week. This timing evolved to ensure that patients were treated sufficiently to provide an adequate state of health.8 These treatment principles applied to patients in chronic renal failure, not to critically ill patients. Intermittent hemodialysis is also used for many patients because it is relatively inexpensive (approximately $130 per treatment, not including staffing) and of short duration (typically 3-4 hours).9 Treatment of a patient 3 times a week allows for a considerable increase in the serum levels of urea nitrogen and creatinine and for variations in electrolyte, water, and acidbase balance between treatments. Orders for intermittent hemodialysis typically require, at a minimum, removal of the previous 24 hours fluid intake during the dialysis treatment. Critically ill patients are prone to hypotension because of the severity of their illness. Therefore,

removal of 2 to 3 L/h of fluid in a patient in an unstable condition may make it difficult to use conventional intermittent hemodialysis.10,11 As a result, critically ill patients with ARF will not achieve adequate water or waste removal with traditional dialysis.12 Repeated episodes of hypotension during intermittent hemodialysis also can lead to ischemia of the nephrons each time the dialysis is performed.2,13 Therefore, the ability of the remaining nephrons to survive, as well as the potentially adverse effects of aggressive fluid removal, should direct the choice of therapy. Continuous Renal Replacement Therapy As the search for better treatments for ARF continues, research findings are indicating that the technique and timing as well as the type of renal replacement therapy used may affect patients survival and recovery of renal function.14-16 The concerns about hemodynamic stability during hemodialysis, nephron injury, and the inability to adequately remove excess water and solutes have led to the development of a slower, less aggressive renal replacement therapy: continuous renal replacement therapy (CRRT). CRRT is an extracorporeal process in which blood is removed from the arterial lumen of a catheter by a peristaltic blood pump and pushed through a semipermeable membrane before being pumped back into patients via the venous lumen of the catheter. These catheters are typically placed in the internal jugular or subclavian vein. When the blood passes through the membrane (hemofilter or dialyzer), electrolytes

and small- and medium-sized wastes are removed from the blood by convection and diffusion. Fluid removal is achieved by ultrafiltration at an established hourly rate and on a continuous basis.17

Types of CRRT
In 1977, Kramer et al18 described a therapy called continuous arteriovenous hemofiltration in which a patients own blood pressure moved the blood from an artery to a vein through a highly porous hemofilter. The blood flow through the hemofilter was driven by the patients mean arterial pressure, and ultrafiltration was achieved by raising and lowering the drain bag in relation to the patient. The blood flow rate was slow because of frequent hypotension experienced by critically ill patients. It resulted in a low driving pressure of the blood through the circuit, much less than what a blood pump can achieve. This slow blood flow limited the volume of ultrafiltrate that could be obtained, which limited the adequacy of the dialysis. A major drawback to continuous arteriovenous hemofiltration was the use of a large catheter in a major artery, commonly the femoral artery, a practice associated with risks for infection, distal thrombosis formation, disconnection, and exsanguination. In the 1980s, a blood pump, such as those used in intermittent hemodialysis, and a double-lumen catheter in a large vein were used to provide a consistent blood-flow rate without the risks associated with the arteriovenous approach. This method of CRRT was called venovenous hemofiltration and has been adopted as the standard for CRRT.

62 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

CRRT mimics the functions of the kidneys in regulating water, electrolytes, and wastes by continuing 24 hours a day, for several days, slowly removing fluid and solutes. The indications that led to the development of CRRT include patients who had fluid overload, diuretic resistance, hemodynamic instability, and azotemia.2 Because fluid removal with CRRT is much slower than with intermittent hemodialysis, CRRT is an ideal therapy for critically ill patients in unstable conditions. For example, a net ultrafiltration rate of 12.5 mL/min is required to remove 3 L of plasma water during 4 hours of intermittent hemodialysis. The same amount can be removed with CRRT in 24 hours with a net ultrafiltration rate of 2 mL/min.19 Removing fluid more slowly and in smaller volumes in hours or days may provide enhanced hemodynamic stability. Membranes in CRRT High-efficiency membranes are used in CRRT for maximum water and waste removal. High-efficiency membranes include high-flux dialyzers and hemofilters. The membranes used are synthetic and biocompatible.20,21 The capability of dialysis membranes lies in the surface area, membrane thickness, pore size and density, and potential to adsorb proteins.22 High-efficiency membranes have both high membrane permeabilities and larger pore sizes and therefore are desirable for CCRT. In all methods of CRRT, as blood flows through the hemofilter, plasma water is filtered through the pores in the hemofilter membrane and produces the ultrafiltrate. The ultrafiltrate produced during CRRT is composed primarily of water, elec-

Replacement fluid

Ultrafiltrate pump

Fluid pump Hemofilter Blood pump From the patient To the patient Air detector

Figure 1 System for continuous venovenous hemofiltration.

trolytes, wastes, and some dialyzable drugs.23 High membrane permeability and large pore size provide excellent clearance of small-molecular-weight solutes and larger substances, up to the maximum pore size.24,25 Examples of small-molecular-weight substances (<0.5 kd) are urea, electrolytes, vitamins, and certain medications. Largemolecular-weight substances such as albumin, red and white blood cells, and drugs bound to proteins cannot pass through a hemofilter membrane (typically with a maximum pore size of 50 kd) because of the large size of the substances.26 Another potential benefit of the use of high-permeability dialyzers and hemofilters is the ability to remove cytokines, which are middlemolecular-weight substances, or decrease their concentration by adsorption to the membrane.27 These inflammatory cytokines, such as interleukin-1, interleukin-6, and interleukin-8, contribute to sepsis and may be altered or removed in CRRT.28 Although no conclusive data confirm the link between the

beneficial clinical effects observed in patients with sepsis who have CRRT, the effect of cytokine removal by adsorption and the preliminary observations of patients outcomes are encouraging.29,30 Continuous Venovenous Hemofiltration Continuous venovenous hemofiltration (CVVH, Figure 1) is defined as a venovenous technique where the ultrafiltrate produced during membrane transit is replaced in part or completely with appropriate replacement solutions to achieve blood purification and volume control.31 In CVVH, convection and ultrafiltration are used to remove waste products. Convection is the movement of solutes under pressure through a membrane along with the movement of water. Convective therapies appear to have advantages over other continuous therapies because of the ability to remove a wider range of solutes with the ultrafiltrate, including some cytokines, a characteristic that may affect patients outcomes.32,33

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 63


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

Physiological fluids termed replacement fluid are used to replace the majority of ultrafiltrate removed hourly, in order to prevent instability and to replace electrolyte losses during CVVH. Replacement fluids generally consist of balanced electrolyte solutions that closely resemble the composition of the ultrafiltrate lost minus the wastes.34 Replacement fluids are infused either into the arterial side of the circuit before the hemofilter, a method called predilution/prefilter, or into the venous side of the circuit after the hemofilter, a method called postdilution/ postfilter. Both methods of fluid replacement achieve the goal of replacing ultrafiltrate volume and electrolytes while removing wastes by convection.23,35 The predilution method of infusing replacement fluid also provides a continuous flush for the hemofilter that dilutes the blood flowing through the filter, a situation that may decrease hemofilter clotting and increase the clearance of solutes.36 Postdilution infusion of solutions replaces fluid and electrolytes but does not affect clotting in the hemofilter. Increasing the volume of ultrafiltrate produced in CVVH by increasing the infusion of replacement fluid increases clearance of both small- and middlemolecular-weight substances by solute drag.23,37,38 Currently, no electrolyte solutions have been specifically approved by the Food and Drug Administration for infusion as replacement fluid. Solutions that are used include lactate- or bicarbonate-based or custom pharmacymixed fluids. Because of the lack of these approved replacement solutions in volumes greater than 1 L, the cost of mixing custom solutions

Dialysate Ultrafiltrate pump Dialysate pump

Hemofilter Blood pump From the patient To the patient Air detector

Figure 2 System for continuous venovenous hemodialysis.

and the ability to provide large volumes for patients treatment, some physicians use purchased customcompounded pharmacy fluids in large volumes or may use commercial solutions as an off-label prescription. Continuous Venovenous Hemodialysis In continuous venovenous hemodialysis (CVVHD, Figure 2), diffusion and ultrafiltration are used to remove waste products. The fluids used are known as dialysate fluids. Dialysate is infused countercurrent to the blood flow, into the outside compartment of the hemofilter to provide a diffusion of wastes from the blood.39 The dialysate fluid is not infused into the blood as in CVVH, rather it is infused into the outside compartment of the hemofilter or dialyzer. In diffusive therapy, small molecular wastes and electrolytes diffuse from the high concentration in the blood into the sterile dialyzing fluid on the other side of the membrane and are removed in the ultrafiltrate. Historically, CRRT fluids were run at lower flow rates, approximately

1 L/h, because no research was available that indicated better treatment efficiency with higher rates and because many older machines lacked the option to increase flow rates. When dialysate is run at lower flow rates, such as 10 to 20 mL/min, the dialysate is almost completely saturated with the wastes.19 However, if the dialysate is run at faster rates, 30 to 60 mL/min, the amount of small molecular waste cleared increases. Diffusion in CVVHD does not affect clearance of larger molecular weight substances. Research40,41 indicates that increasing the dialysate rate improves the efficacy of dialysis. Most current CRRT equipment allows fluid rates to be prescribed at the higher rates, often up to 150 to 200 mL/min to improve clearance. For CVVHD, dialysate solutions are available from a variety of sources. The solutions may be mixed by hospital pharmacies, peritoneal dialysate solutions may be used, or commercial solutions approved by the Food and Drug Administration may be purchased. Disadvantages of relying on hospital pharmacies to mix either

64 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

dialysate or replacement solutions include the high cost of labor to produce multiple liters of solutions consistently and safely for ongoing CRRT treatments. Peritoneal dialysate solutions contain large amounts of glucose and are lactate based, making them less suitable for CVVHD. Lactate solutions may worsen metabolic acidosis in patients with metabolic derangements and hepatic failure.42 Bicarbonate-based solutions are preferred for patients with hepatic failure who cannot metabolize the lactate and are also more physiological than are lactate solutions. Several commercial dialysate solutions in large volumes are currently available, such as PrismaSate (Gambro, Lakewood, Colo), Baxter Premixed Dialysate and ACCUSOL (Baxter, Deerfield, Ill), PureFlow (NxStage Medical, Lawrence Mass), and Duosol (B. Braun, Bethlehem, Pa). These solutions provide a wide choice of electrolyte compositions and the choice of bicarbonate- or lactatebased solutions to meet individual patients needs. Continuous Venovenous Hemodiafiltration In continuous venovenous hemodiafiltration (CVVHDF, Figure 3), diffusion, convection, and ultrafiltration are used to remove wastes and water. In this method, dialysate and replacement fluids are used simultaneously in various combinations of rates. The goal is to offer both a convective therapy, for clearance of middle-molecular-weight substances, and a diffusive therapy, for removal of smaller substances.43 This therapy was widely used to provide a more efficient dialysis when machines were limited in the ability

Dialysate Replacement fluid Ultrafiltrate pump Dialysate pump

Fluid pump Hemofilter Blood pump From the patient To the patient Air detector

Figure 3 System for continuous venovenous hemodiafiltration.

to infuse large quantities of fluids. However, current technology for CRRT provides the ability to infuse fluid, either replacement or dialysate, at higher rates to provide efficient therapy. The ability to use only a single fluid effectively also improves the simplicity of performing CRRT. Slow Continuous Ultrafiltration Slow continuous ultrafiltration (SCUF, Figure 4) is a hemofiltration therapy used primarily for fluid removal.44 No dialysate or replacement fluids are used because wastes,

electrolyte balance, and acid-base status may not be as critical an issue in patients who have SCUF and in patients who have other CRRTs. As it is removed from the hemofilter, ultrafiltrate is regulated to provide a slow, continuous removal of plasma water for diuresis, for example, 50 to 500 mL/h to achieve fluid balance. SCUF is a good therapy of choice when the only goal is fluid removal and the patient does not have azotemia. Patients who may benefit from SCUF include those who are refractory to diuretics or who need adjunc-

Ultrafiltrate pump

Hemofilter Blood pump From the patient To the patient Air detector

Figure 4 System for slow continuous ultrafiltration.

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 65


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

tive fluid removal, such as patients with pulmonary edema, sepsis, heart failure, or acute respiratory distress syndrome who need diuresis to improve pulmonary function. Research45,46 indicates that excess fluid that can be effectively and slowly removed in critically ill patients may improve oxygenation, cardiac output, and mean arterial pressure. In infants and children, research47,48 suggests that earlier intervention with CRRT and fluid overload is associated with greater survival, indicating that fluid removal may have a beneficial effect on outcome.

Table 1 Anticoagulation options in continuous renal replacement therapy


Option Comments

Flushes with isotonic Not an anticoagulant sodium chloride solution Helps flush the hemofilter, possibly prolonging filter life Heparin Regional citrate Easy, inexpensive May cause bleeding or heparin-induced thrombocytopenia More labor intensive than other options Requires diligent monitoring of results of laboratory tests, such as serum levels of sodium, ionized calcium, and bicarbonate Requires infusion of calcium outside the circuit Provides good anticoagulation Large sodium load occurs when trisodium citrate used May cause alkalosis Variable success Need brisk blood-flow rates and may not prevent clotting Simplest method Heparin infused before the filter and protamine infused after the filter Requires diligent monitoring of anticoagulation to keep system patent Protamine may cause adverse reactions Good anticoagulation, but much more expensive than other options

No anticoagulation

Regional heparinization

Anticoagulation for CRRT


During CRRT, a patients blood is outside the body and in contact with artificial tubing and filters. The result is stimulation of the coagulation cascade and, more important, the complement cascade if a biocompatible membrane is not used. The goal for anticoagulation in CRRT is to reduce clotting in the hemofilter to maximize the CRRT circuit life. Avoiding interruptions in CRRT by preventing clotting provides continuous therapy for the patient. Although CRRT is intended to run for 24 hours a day, the average therapy time is actually closer to 16 hours a day because of interruptions.49 These interruptions can decrease the effect and efficacy of CRRT markedly.50 CRRT can be performed with or without anticoagulation. The choice of anticoagulant depends on the physicians preference, the patients condition, and the familiarity of the nursing staff with anticoagulation regimens.51 At times, the choice is to not give a patient an anticoagulant or use an anticoagulant in the CRRT system. Anticoagulation may not
Direct thrombin inhibitors (eg, Argatroban, lepirudin)

be indicated in patients who have recently had surgery, have sepsis or immunosuppression, or have hepatic failure or thrombocytopenia. Another reason to use anticoagulants is to maximize the CRRT circuit life so that the therapy is continuous for several days. This maximization can reduce the cost of the circuit tubing and components, which often cost approximately $150 to $200 or more a set, and thereby reduce the cost of patients treatment.9,13 Patients receiving anticoagulation for CRRT should be monitored on a routine basis. The most common tests used to monitor coagulation are activated clotting time and activated partial thromboplastin time (aPTT).52 Activated clotting times can be measured at the bedside but require that the critical care staff maintain competency for point-of-care testing. Activated clot-

ting times may be maintained at 180 to 220 seconds or according to institutional protocols.53 The degree of anticoagulation is most commonly determined by using aPTT. The aPTT is maintained at 1.5 to 2 times normal to maintain patency of the circuitry.54 The bedside nurse is responsible for monitoring any adverse effects of anticoagulation, including hemorrhage, formation of hematomas, thrombocytopenia, and allergic reactions. Heparin is the most widely used anticoagulant. Other options include citrate, direct thrombin inhibitors, and flushes with isotonic sodium chloride solution. Ideally, anticoagulation is done without producing systemic anticoagulation in the patient. The type of therapy, the anticoagulant used, and the blood-flow rates are all key components of keeping the CRRT system free of clots (Table 1.)

66 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

Heparin Heparin is the least expensive anticoagulant and can be used either systemically or regionally. When heparin is used, the hemofilter may be flushed with a dilute heparin solution continuously or intermittently. Systemic heparinization includes infusing heparin into a separate intravenous access or into the arterial side of the CRRT circuit. Infusion of the heparin into the arterial side of the CRRT circuit allows mixing of the heparin with the blood from the patient before the blood reaches the filter (prefilter). The heparin can be infused via an intravenous pump or a syringe pump, depending on the CRRT system used. Systemic heparinization provides anticoagulation of the circuit as well as for the patient. Heparin-induced thrombocytopenia is a complication of heparin therapy. This complication is well documented and therefore has limited the popularity of heparin for anticoagulation in recent years.55 Heparin-induced thrombocytopenia occurs when antibodies to heparin bind to coagulation factor IV on platelets, causing platelet activation and aggregation.56 These changes in turn cause the generation of venous and arterial thrombi and a decrease in the platelet count. Even after heparin is discontinued, the platelet count may remain low. Consequently, in patients with heparin-induced thrombocytopenia, the concerns for thrombi and the associated costs of changing CRRT circuits frequently have led to the use of other anticoagulants in CRRT. Regional heparinization involves use of an anticoagulant in the circuit only, not systemic heparinization in

the patient. Heparin is infused directly via a syringe or an intravenous pump into the circuit blood prefilter. Protamine, a heparin antagonist, is delivered via an intravenous pump into the circuit near the catheter on the return blood line to deactivate the heparin.57 Anticoagulation monitoring for regional heparinization requires determining the aPTT of blood from the patient (eg, blood obtained via a peripheral site or an arterial catheter) and the aPTT of blood in the CRRT circuit (usually from the postfilter preprotamine infusion side of the CRRT circuit) regularly. The goal in regional heparinization is a normal aPTT for the patient and an aPTT of approximately 100 seconds for the postfilter level. Advantages of monitoring of aPTT in both the circuit and the patient include tight heparinization, that is, the heparin is not sent to the patient, and therefore anticoagulation occurs only in the circuit. Disadvantages include the requirement for meticulous monitoring of laboratory results and frequent adjustment of dosage of both the heparin and the protamine. Direct Thrombin Inhibitors Argatroban (GlaxoSmithKline, Research Triangle Park, NC) and lepirudin (Refludan, Berlex Pharmaceuticals, Richmond, Calif ) are both direct thrombin inhibitors. Direct thrombin inhibitors are used for their anticoagulant properties in patients with heparin-induced thrombocytopenia who are undergoing CRRT and require anticoagulation. Lepirudin is cleared by the kidneys and therefore may not be the drug of choice for patients in ARF. Arga-

troban is eliminated by the liver and is therefore more suitable for use in patients with renal failure.56 Both Argatroban and lepirudin are infused via an intravenous pump into the arterial or access side of the CRRT system. Both drugs are considerably more expensive than heparin. Citrate Citrate is also used in CRRT because of the compounds excellent anticoagulant ability and potential to prolong circuit life. Calcium is an essential component of the clotting cascade.58 Citrate binds to the calcium in the patients blood within the CRRT system and prevents clotting. Citrate is infused prefilter into the CRRT system, and calcium is typically infused via another intravenous line outside the circuit. Ionized calcium levels are routinely monitored because the ionized form of calcium is a the biologically active form of calcium and accounts for about 50% of the calcium in the blood in normal conditions.59 Citrate is available as a trisodium citrate or as anticoagulant citrate dextrose formula A. Trisodium citrate has a higher sodium content than does anticoagulant citrate dextrose formula A (420 mmol/L vs 112.9 mmol/L).51 Citrate is used in CVVH, CVVHD, CVVHDF, and SCUF. Citrate can be used as a replacement fluid that contains less sodium than normal.60 In CVVHD, a dialysate that also has less sodium than normal may be used to manage the sodium in the citrate solution. Typically, calcium-free solutions are preferred in CRRT to prevent interaction with the infused citrate. Some clinicians use replacement or dialysate solutions containing calcium because the amount of calcium in these solutions

68 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

is small and unlikely to affect the efficacy of the citrate.61 Alkalosis is a potential complication of CRRT and, in particular, citrate anticoagulation because the body metabolizes citrate into bicarbonate.62,63 The resulting alkalosis can be treated by administering sodium chloride to provide hydrogen ions to produce hydrochloric acid, infusing hydrochloric acid, or reducing the citrate infusion rate.23,64 Citrate anticoagulation in patients with hepatic failure or with lactic acidosis may be contraindicated because these patients may not be able to metabolize citrate.54 An essential requirement of citrate anticoagulation is diligent monitoring of all laboratory values, including levels of ionized calcium and sodium and acid-base status. Flushes With Isotonic Sodium Chloride Solution When a patients condition warrants that no anticoagulant be used, the circuit may be flushed at intervals with small boluses of isotonic sodium chloride solution to reduce stagnation of blood in the hemofilter or dialyzer and keep the circuit free of clots. Some protocols dictate that when no anticoagulant is used, the circuit should be flushed with 50 to 100 mL of isotonic sodium chloride solution each hour to reduce stagnation of the blood in the membrane itself. Isotonic sodium chloride solution is not an anticoagulant, so this maneuver may deter clotting in the hemofilter, but it also increases the volume of fluid intake for the patient. Maintaining the patency of the CRRT circuit for a patient who is not given an anticoagulant may pose a challenge. Other options to reduce

clotting in the circuit include the use of blood tubing that minimizes the air-blood interface, such as eliminating the arterial or venous air traps. Tubing designs that provide methods for air removal without using a large air-blood interface and use of circuit design in which the blood flow moves in straight lines instead of around a blood pump may reduce stagnation and pooling of the blood as the blood flows through the circuit. Because replacement fluid is infused directly into the blood prefilter in CVVH, preventing clotting in the hemofilter by diluting the blood may be helpful. Use of a well-placed, large-bore catheter also can help streamline blood flow from the patient and back to the patient. Fluid Management in CRRT Most patients undergoing CRRT are oliguric, anuric, and possibly volume overloaded. The volume of hourly ultrafiltrate removed depends on an hourly fluid-balance calculation and an assessment of the patients volume status. Fluid management in CRRT typically involves hourly calculation of the patients non-CRRT system intake (eg, infusions , medications, feedings) plus fluid loss ordered by the physician minus non-CRRT

system output (eg, urine, drainage fluid, blood loss).23 Excess fluid volume to be removed in a patient with fluid overload is usually termed net loss and is ordered by a physician. An example of net loss volume ordered may be 25 to 200 mL/h more than the hourly intake to ensure a slow and gentle removal of the excess fluid volume (Table 2). The CRRT system infuses and removes fluid after the fluid balance is calculated and the desired volumes are input to the system. The system monitors the volume of the dialysate and/or replacement fluids infused and the volume of fluid removed on an ongoing basis. Scales or balancing chambers are used to manage the administration and removal of fluid. Any volume of fluid infused outside the CRRT system, such as infusions, tube feedings, boluses, and medications, is not accounted for unless the volume is programmed into the machine to be removed. If a scale system is used, the scales balance the weight of the volume of fluid programmed to be lost on the infusion scale and the weight gained on the output scale. In a balancing chamber system, the balance chambers empty and fill precisely, to balance the fluid volume programmed

Table 2 Typical calculation of fluid balance for continuous renal replacement therapy
Variable A: All intake of fluid (eg, infusions, antibiotics, tube feedings, anticoagulants) B: Desired fluid loss ordered by physician C: Output in previous hour (eg, chest tubes, drains, nasogastric tubes) Programmed fluid output D: Actual fluid volume achieved Actual net fluid lost: A C D Example, mL 80 50 10 120 110 -40

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 69


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

in and out, ensuring that the fluid volume desired is accurate. In either type of system, to verify accuracy, a nurse can monitor the therapy history, if available, for the volume of actual fluid removed at the end of each hour and compare that volume with the volume that was programmed. The volumes programmed to be infused and removed by the system should be within the manufacturers error specifications of the system in use. If the volumes are incorrect, or if the nursing assessment indicates an error, additional troubleshooting is required to achieve the patients goals and to ensure the patients safety. Every time an alarm occurs, or the pumps stop on the system, the fluid removal is also stopped. Therefore, under certain conditions, the programmed volume of fluid to be removed may not be the volume that was removed that hour. Regardless of the type of system used, the fluid balance should be calculated hourly or according to the institutional standard to monitor the patients status and fluid balance. Before CRRT is started, patients should have a complete nursing assessment (Table 3). The assessment includes evaluation of the fluid status and the volume of fluid the patient is receiving each hour, the patients baseline blood pressure, dosages of any vasopressors being administered, weight (dry weight before admission and current weight), presence of edema, central venous pressure, pulmonary artery occlusion pressures, cardiac index, and cardiac output if the patient has a pulmonary artery catheter in place. Other helpful measurements include arterial blood gases, arterial oxygen saturation, and mixed venous oxygen saturation. Once CRRT

is started, ongoing measurements of these parameters indicate the patients tolerance of the procedure as well as any improvement in fluid status. Decreases in blood pressure, central venous pressure, pulmonary pressures, and weight may indicate that fluid is being lost and the patient is experiencing the benefits of CRRT. A marked decrease in blood pressure, mixed venous oxygen saturation, or arterial oxygen saturation; an increase in edema; or weight gain may indicate that the therapy objectives are not being achieved or that the circuit is not functioning properly. In this instance, a physician should be notified and fluid removal should be decreased or stopped until the patients condition becomes more stable. Because one goal of CRRT is to reduce fluid overload, the bedside nurse should discuss the possibility of reducing intake to minimal volumes of fluids if at all possible and concentrating medications and infusions to minimize fluid intake. Mechanical failures can occur if alarms are ignored or bypassed without determining the cause of the alarms. If scales are not properly calibrated, the volumes of fluid administered and removed may not be the programmed volumes. Bypassing alarms without correcting the cause of the alarm is a safety hazard.

or more provide a more efficient treatment than do slower rates; however, such large volumes of fluid can quickly lower a patients temperature if the fluids are not warmed.75,76 Effects of hypothermia include dysfunction of clotting factors and platelets, activation of fibrinolysis, and cardiac dysrhythmias.77 Some CRRT manufacturers offer a blood warmer for the blood in the circuit, but most systems have some type of plate or convective warmer for warming the therapy fluids. Before CRRT is started and once it has begun, the patients temperature should be routinely monitored and the warmer temperature increased as necessary to keep the patients temperature near normal. If increasing the warmer temperature does not correct the hypothermia adequately, or fluid warming options are not available, warming blankets and increases in the room temperature may be used. Nursing tasks include monitoring the patients temperature, implementing warming interventions if needed, and monitoring for signs and symptoms of infection (eg, increased white blood cell counts), because the patients temperature is masked by the cooling effect of the circuit.

Air Embolus
Air embolus can occur if a patient receives air in the blood returned. CRRT systems have air detectors built in to detect even microbubbles of air. If the systems safety mechanisms are bypassed, a patient can receive an air embolus. Alarms can occur if the air is not properly removed from the blood circuit during priming or if a port in the circuit is loose or open. Air also can occur

Hypothermia in CRRT
Hypothermia is a complication of CRRT.73,74 The typical blood circuit can contain anywhere from 110 mL to 200 mL or more of blood outside the body at any time, a situation that contributes to cooling of the patient. Solutions such as replacement fluid and dialysate are used at room temperature. Infusion rates of 2 to 5 L/h

70 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

Table 3 Nursing management during continuous renal replacement therapy (CRRT)


Assessment Overall assessment Nursing management Obtain information on the following: Past medical illnesses Current diagnoses Current therapies Medications Laboratory values Allergies Determine the following: Blood pressure, heart rate, cardiac rhythm, Central venous pressure, pulmonary artery pressures, stroke volume, cardiac index/cardiac output, peripheral pulses Measure or calculate the following: Oxygen saturation as measured by pulse oximetry, fraction of inspired oxygen, carbon dioxide levels, PaO2, ventilator settings, respiratory rate and effort, arterial blood gases, ratio of PaO2 to fraction of inspired oxygen Assess gastrointestinal function and nutritional status Assess or determine the following: Edema Body weight Urine output, fluid intake Fluid losses (eg, blood loss, drainage fluid) Calculate CRRT fluid balance Rationale/comments Information obtained about the patients medical history and current treatments can provide information about the effect of the therapy Knowledge of the patient's normal values and current status helps to follow trends, instead of individual values The patient's cardiac status and pulmonary pressures indicate the effect of the fluid removal and the patient's tolerance of the therapy Too much fluid removed can decrease blood pressure significantly65 Respiratory status and parameters can indicate positive effects of the therapy Unwanted changes in arterial blood gases, development of acute respiratory distress syndrome, and increases in pulmonary pressures indicate adverse effects of overhydration Adequate nutritional balance is important to promote wound healing and provide proper metabolic function Ongoing assessment of fluid balance helps determine the effect of the therapy and the patient's tolerance of it Prescribed fluid-balance goals should be compared with achieved goals A physician should be notified if fluid goals cannot be achieved because the patients condition is unstable. Patients undergoing dialytic therapies can become confused as serum urea nitrogen levels increase or decrease This symptom occurs because during dialysis the osmolality of cerebral spinal fluid decreases more slowly than the osmolality of the blood66 Fluid gains may be indicated by increases in blood pressure, pulmonary capillary wedge pressure, and central venous pressure and a decrease in arterial oxygen saturation Fluid losses may be indicated by decreases in blood pressure, central venous pressure, and pulmonary capillary wedge pressure Patients weight often increases as fluid is gained, and an increase in edema may occur Fluid-balance calculations are a potential source of error in CRRT Incorrect calculations can cause unwanted gain or loss of fluid Some patients do not tolerate prescribed fluid removal A physician should be notified about the effect of the prescribed fluid loss 44,65

Cardiovascular assessment

Respiratory assessment

Gastrointestinal assessment Renal/ fluid volume assessment

Neurological assessment

Assess or obtain the following: Mentation Score on Glasgow Coma Scale Pain Medication effects (especially if patient is receiving sedatives or paralytics) Calculate fluid balance once an hour or per institutional policy

CRRT fluid balance calculations

Continued

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 71


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

Table 3 Continued
Assessment Ongoing circuit monitoring Nursing management Observe or check for the following hourly: Blood-flow rate Venous or return pressures Arterial or access pressures Filter pressures (if applicable) Balance pressures (if applicable) Effluent pressures Color of the blood in the circuit Presence of air Rationale/comments The documentation in CRRT is not individually in each hourly value, but in the trends Changes in pressures (ie, increases in filter, balance, and effluent pressures) can indicate clotting Pressures can also alert nurses about disconnection or catheter dysfunction Blood-flow rates and fluid rates may have to be adjusted according to prescription The color of the blood can indicate clotting (eg, the blood becomes very dark) Air should be assessed continually The patients blood is outside the body in a large circuit Hypothermia is a common complication of CRRT Maintaining body temperature promotes healing and helps maintain normal coagulation and normal laboratory values Colder patients may experience cardiac arrhythmias and are prone to using more energy in addition to increasing cardiac output67,68 Patency of the catheter can affect the effectiveness of the therapy Patency can be quickly evaluated by flushing 10 mL of isotonic sodium chloride solution into each lumen of the catheter and assessing resistance by quickly pulling back the blood into the syringe (remove anticoagulant first if applicable); blood should quickly and easily fill the syringe Aspiration of air bubbles or a catch in aspirating blood into the syringe may indicate a problem with the catheter69,70 The type of solution used in CRRT can have a significant effect on a patients electrolyte levels Monitoring laboratory values can assist in preventing sudden changes in electrolyte levels and provide for prompt intervention65,71

Body temperature

Assess for hypothermia and hyperthermia Use a warmer for fluid or blood if indicated

Dialysis catheter care and patency

Monitor catheter patency before and during CRRT and at disconnection of the CRRT system Monitor access pressures hourly to assess catheter flow and detect access problems Manage catheter dressing changes according to institutional policy

Monitoring of electrolyte balance and dialysis solutions

Check for the proper solution, dialysate, or replacement fluid and the proper infusion site Be sure laboratory work is done routinely or per institutional protocol to assess the effectiveness of the therapy Check the solutions to make sure they are the correct prescription and are infusing into the correct port on the circuit: dialysate into the dialysate compartment and replacement fluid into the prefilter or postfilter infusion ports into the blood Provide proper circuit care and interventions to prevent nosocomial infection

CRRT circuit care and management

All circuit interventions require using precautions such as gloves, masks, and aseptic or sterile techniques to protect the patient from exposure to infectious agents Patients receiving CRRT have a higher risk of bloodstream infections than other patients do72 Nurses who provide care for patients receiving CRRT should be able to troubleshoot alarms Overriding alarms without investigating the cause is a safety hazard The alarms should also be distinct and loud enough to be differentiated from other alarms in the room

Alarms

Determine the cause of all alarms

72 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

in the circuit if the access cannot provide the blood flow programmed on the machine. In this situation, the blood pump will run, but a vacuum is created, causing air to move through the circuit. In each of these situations, the nurse caring for the patient is responsible for troubleshooting the system to determine the source of the air or for checking the help screens on the system to determine if therapy can be resumed. After the system is primed and brought to the bedside and before the connection with the patient is established, the circuit should be checked to ensure that all air has been removed. It is imperative to verify that the arterial or access side of the access tubing is securely connected to the catheter and, even more important, that the venous or return side of the tubing is securely attached to the catheter. If the venous side of the blood tubing is not connected securely to the catheter, an air embolism can occur because the blood will have traveled past the machines air detector. Nurses must continually assess the circuit tubing for the presence of air.

or to an inability to detect signs of clotting in the hemofilter is detrimental to the patient and may affect the patients safety. Nurses yearly competency testing should include a review of rinsing patients blood back in addition to a review of machine alarms.

Transport Procedures
At times, a patient receiving CRRT may need to go out of the critical care unit for a diagnostic procedure or test (eg, computed tomography or angiography). Before the patient leaves the critical care unit, the connection with the CRRT system is discontinued, and the patients blood is returned to the patient by flushing the blood back with isotonic sodium chloride solution. The machine is placed in a recirculation mode while the patient is away. When the patient returns to the critical care unit, the system is taken out of recirculation mode, the connection between the patient and the machine is reestablished, and therapy is resumed. Flushing the patients blood back in this situation not only minimizes blood loss but also allows maximum use of the CRRT circuit if the circuit is not clotted. Institutions should have protocols in place to guide the length of time CRRT can be discontinued while the isotonic sodium chloride solution recirculates. Protocols can be developed by using the manufacturers guidelines and recommendations from the infection control service and the blood bank.

Minimizing Blood Loss in CRRT


Minimizing blood loss in patients receiving CRRT is always a priority. Prompt attention to alarms and knowledge of troubleshooting can prevent loss of blood in the circuit. Nurses caring for a patient receiving CRRT should know how to perform an automatic or manual return of the patients blood when CRRT is discontinued or the circuit is clotted. As mentioned earlier, some circuits can hold 200 mL or more of blood. Ongoing blood loss due to failure to rinse the blood back to the patient

Innovative Developments With CRRT


Timing of therapy, early initiation of renal replacement therapy, and

the adequacy of dialysis (eg, dialysis dose) may affect patients outcomes.78-81 The impact of adequate amount or dose of dialysis in ARF has been long debated. In CRRT, an adequate dose is considered the amount of dialysis, with fluids, based on the patients weight required to provide a therapeutic treatment, as opposed to conventional dialysis in which not only the patients weight but also the time on dialysis is taken into account.35,79 Some think that the actual dose of dialysis delivered in ARF is low and is strongly affected by the patients underlying disease process, hypercatabolic state, hemodynamic instability, and volume overload.1,14,82 The importance of dose of dialysis is being examined in a randomized trial83 by researchers at the Department of Veterans Affairs and the National Institutes of Health. The purpose of the trial is to determine the effect of conventional dialysis dose versus intensive dialysis on patients outcomes. The aim is to compare traditional methods of dosing in CRRT and intermittent hemodialysis, as well as in slow extended dialysis. Other dose-related research suggests that higher blood-flow rates (200-300 mL/min) can enhance clearance in CRRT. These higher blood-flow rates combined with fluid infusion rates determined on the basis of body weight may improve morbidity and mortality and also preserve renal function. Ronco et al84 studied administration of replacement fluid at rates of 20, 35, and 45 mL/kg per hour with use of moderate bloodflow rates in CRRT. In patients given fluids at rates of 20 mL/kg per hour, survival was 41%, whereas in patients

74 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

given fluids at 35 and 45 mL/kg per hour, survival was 57%. In addition, 90% or more of the survivors in the 35 and 45 mL/kg per hour group had full return of renal function. The weight-based fluid doses used in the study84 were higher than the smaller volumes of fluids thought to be beneficial in the past. Slow Extended Daily Dialysis A therapy that some think provides the same or similar benefits of 24-hour CRRT is termed slow extended daily dialysis (SLEDD) or SHIFT therapy, because the therapy is completed during a single nursing shift. SLEDD is done exactly as CRRT is but is completed in a shorter time, such as 8 to 12 hours instead of 24 hours of continuous treatment. Compared with other methods of CRRT, SLEDD requires higher fluid-flow rates, higher blood-flow rates, and higher hourly volumes of fluid removed to condense the treatment.85 The shorter duration allows patients to be treated with renal replacement, for example, during the night shift but also be free for tests, rehabilitation, or discontinuation of ventilator support during the day. Diligent assessment of patients hemodynamic stability and fluidvolume status is imperative when SLEDD is used because compared with other CRRT methods, approximately double the amount of fluid may need to be removed in a shorter time. During SLEDD, anticoagulant may not be required because of the shorter treatment time. Some researchers86,87 have indicated that SLEDD or SHIFT therapy combines excellent waste removal and supports cardiovascular stability and is still as efficient as a 24-hour CRRT.

Nonrenal Indications for CRRT Novel approaches of using CRRT to treat sepsis have been proposed. A method of high-volume ultrafiltration of 4 to 6 L/h for 6 to 8 hours termed pulse hemofiltration may provide benefits such as elimination of cytokines and middle-molecularweight substances known to cause sepsis.88-90 Researchers91,92 continue to examine using continuous hemofiltration to remove inflammatory mediators in patients with sepsis. Ronco et al93 suggest that the management of patients with multiorgan dysfunction syndrome should focus not only on renal replacement but also on a multiorgan support therapy. Multiorgan support therapy is based on the principle that all organs share one thing in common: contact with blood. Therefore, blood purification and modulation of the blood composition may have a potential effect on all body organs. On the basis of this principle, CRRT may support several organs at one time by early detection and correction of the abnormalities that occur in multiorgan dysfunction syndrome. The results of other studies94-96 suggest that sepsis can be treated by using hemoperfusion. In hemoperfusion, a plasma filtrate sorbent filter is used in place of a hemofilter on a CRRT-type circuit. In hemoperfusion, adsorption of the solutes is a primary mechanism of cytokine clearance. The sorbent filter used can be either charcoal or a synthetic material. The filters adsorb cytokines and appear to improve survival in animal models of sepsis.97 A similar treatment for sepsis is coupled plasma filtration.98 In this treatment, plasma is filtered to improve blood purification; blood is

passed through a hemofilter-type membrane with larger pores so that the blood is separated from the plasma water and proteins, which are removed. The plasma is then pumped through another filter to remove water and smaller molecular weight substances. Because the substances removed are larger than those removed in CRRT alone, the benefit of coupled plasma filtration may be an increase in the removal of cytokines from the plasma of patients who have sepsis. This model is based on the benefits of plasmapheresis in critically ill patients.99 Treatment of decompensated heart failure with ultrafiltration has been studied in the past and currently is being examined more closely.100,101 Patients who have myocardial dysfunction or congestive heart failure are often refractory to conventional therapy (eg, diuretics and inotropic agents). CRRT for the removal of excess fluid can improve myocardial elasticity and cardiovascular stability and optimize fluid balance for patients who may also have some degree of renal impairment.102 Some applications of this therapy include the use of traditional CRRT machines to perform SCUF for short periods and the use of more specialized equipment and peripheral intravenous blood access for simple removal of plasma water. The use of a bioengineered artificial kidney is yet another exciting area of research.103 Humes et al103 have performed research in the treatment of patients in ARF in which CRRT is used in tandem with a bioartificial kidney, known as a renal tubule assist device. CRRT can replace some functions of the kidneys, such as water and waste removal,

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 75


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

but it does not provide the metabolic, immunological, or endocrine functions of the kidneys. This bioartificial kidney contains human renal proximal tubule cells that are grown and seeded inside the fibers of a conventional hollow fiber dialyzer. Humes et al postulate that when the tubule cells are bathed in ultrafiltrate from the CRRT circuit, the cells act similar to a human kidney. The use of human renal tubule cells may provide a dynamic, interactive, and individualized therapy that responds to the pathophysiological conditions of critically ill patients, reducing morbidity and mortality by providing a more complete renal replacement therapy.104,105 Phase 2 clinical trials with the bioartificial kidney have recently been completed, and some results are promising. Studies106,107 to date have indicated that mortality does not differ between patients who have had CRRT and patients who have had intermittent hemodialysis, but critically ill patients may experience other benefits from CRRT that are not possible with intermittent hemodialysis. Although CRRT has many benefits, like any other therapy, it does not guarantee survival. Patients requiring CRRT are often in a tenuous situation, and once CRRT is started, the therapy may or may not be discontinued without resulting in death. The decision to initiate CRRT requires clear and explicit understanding by patients and their families about the indications for the therapy and the potential that the therapy may or may not affect recovery. Critical care nurses have a responsibility to advocate for patients and patients families, encourage questions, and partici-

pate in education of patients and patients families about CRRT. Recent research indicating treatment with larger volumes of fluids each hour to provide a more adequate therapy may affect how CRRT continues to be used in critical care units.84,88-90 Some centers have set standards for care of patients receiving CRRT that require a ratio of 1 nurse to 1 patient, not only because of the severity of illness of patients receiving CRRT but also because of the additional burden of managing multiple liters of fluid volumes each hour and monitoring an extracorporeal blood circuit.65,71 This paradigm shift may contribute to an increased nursing workload if containers of therapy fluid and ultrafiltrate require replacement and disposal several times a shift or per hour. (Note: most commercial fluid and disposal bags are 2.5- to 7-L bags.) If the practice of using higher volumes of fluids increases, the issue of nursing time required to replace multiple liters of fluids for therapy and dispose of larger volumes of ultrafiltrate more frequently will have to be addressed.

junction with a bioartificial kidney will require further research and may offer promise for patients in whom ARF develops in the critical care unit.
Financial Disclosures
None reported.

References
1. Jorres A. Acute renal failure: extracorporeal treatment strategies. Minerva Med. 2002;93:329-394. 2. Mueller BA, Krause MA, Ronco C, Clark, WR. Considerations in the management of patients in acute renal failure. In: Hrl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, eds. Replacement for Renal Function by Dialysis. 5th ed. Norwell, Mass: Kluwer Academic Publishers; 2004:1181-1202. 3. Clermont G, Acker CG, Angus DC, Sirio CA, Pinsky MR, Johnson JP. Renal failure in the ICU: comparison of the impact of acute renal failure and end-stage renal disease on ICU outcomes. Kidney Int. 2002;62:986-996. 4. Siegel N, Shah S. Acute renal failure: directions for the next decade. J Am Soc Nephrol. 2003;14:2176-2177. 5. Schetz M. Renal replacement therapy in patients with chronic (end-stage) renal failure and acute illness. In: Hrl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, eds. Replacement for Renal Function by Dialysis. 5th ed. Norwell, Mass: Kluwer Academic Publishers; 2004:1139-1153. 6. Mehta RL, Pascual MT, Soroko S, Chertow GM, PICARD Study Group. Diuretics, mortality, and nonrecovery of renal function in acute renal failure. JAMA. 2002;288:2547-2553. 7. Shilliday IR, Quinn KJ, Allison MEM. Loop diuretics in the management of acute renal failure: a prospective, double-blind, placebocontrolled, randomized study. Nephrol Dial Transplant. 1997;12:2592-2596. 8. Gutch CF. Principles of hemodialysis. In: Gutch CF, Stoner MH, Corea AL. Review of Hemodialysis for Nurses and Dialysis Personnel. 6th ed. St Louis, Mo: Mosby; 1999:45. 9. Cerda J, Bunchman TE, Gardner A, Hass J. Hospital reimbursement and cost benefit of CRRT [abstract]. Blood Purif. 2003;21:203204. Abstract Doi 10-1159/000069158. 10. Schortgen F, Soubrier N, Delclaux C, et al. Hemodynamic tolerance of intermittent hemodialysis in critically ill patients: usefulness of practice guidelines. Am J Respir Crit Care Med. 2000;162:197-202. 11. Gaspar LJ, Moreira NM, Moutinho AA, Moreira PJ, Lima HB. Continuous renal replacement therapies. EDTNA ERCA J. 2002;suppl 2;19-22. 12. Brady H, Brenner B, Clarkston M, Lieberthal W. Acute renal failure. In: Brenner BM, Rector FC, eds. Brenner and Rectors The Kidney. Vol 2. 6th ed. Philadelphia, Pa: WB Saunders Co; 2000:1201-1262. 13. Manns B, Doig, CJ, Lee H, et al. Cost of acute renal failure requiring dialysis in the intensive care unit: clinical and resource implications of renal recovery. Crit Care Med. 2003;31:449-455. 14. Palevsky PM, Baldwin I, Davenport A, Goldstein S, Paganini E. Renal replacement therapy and the kidney: minimizing the

Summary
Currently, mortality associated with ARF remains high, and CRRT is becoming the therapy of choice for the treatment of ARF in critically ill patients. CRRT has many benefits for patients in the critical care unit, including improved hemodynamic stability, excellent fluid and solute removal, and possibly other benefits such as enhanced cytokine removal and prevention of sepsis. The use of CRRT in a multicenter trial may be necessary to validate its efficacy in the treatment of ARF. The use of CRRT for nonrenal indications and in con-

76 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

15. 16. 17. 18.

19. 20. 21.

22.

23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. 39. 40.

41.

impact of renal replacement therapy on recovery of acute renal failure. Curr Opin Crit Care. 2005;11:548-554. Demirkilic U, Kuralay E, Yenicesu M, et al. Timing of replacement therapy for acute renal failure after cardiac surgery. J Card Surg. 2004;19:1720. Swartz RD, Messana JM, Orzol S, Port FK. Comparing continuous hemofiltration with hemodialysis in patients with severe acute renal failure. Am J Kidney Dis. 1999; 34:424-432. Price C. Continuous renal replacement therapy. In: Parker J, ed. Contemporary Nephrology Nursing. Pitman, NJ: Anthony Jannetti Publishing; 1998:579-587. Kramer P, Wigger W, Reiger J, Matthaei D, Scheler F. Arteriovenous haemofiltration: a new and simple method for treatment of overhydrated patients resistant to diuretics [in German]. Klin Wochenschr. 1977;55: 1121-1122. Manns M, Sigler M, Teehan B. Continuous renal replacement therapies: an update. Am J Kidney Dis. 1999;32:185-207. Locatelli F, Di Filippo S, Pontoriero G. Fluid and electrolyte balance during extracorporeal therapies. In: Ronco C, Bellomo R, eds. Critical Care Nephrology. Norwell, Mass: Kluwer Academic Publishers; 1998:249-259. Ronco C, Paolo M, Bowry G, Bowry SK. Membranes for hemodialysis. In: Hrl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, eds. Replacement for Renal Function by Dialysis. 5th ed. Norwell, Mass: Kluwer Academic Publishers; 2004:301-323. Schmaldienst S, Hrl WH. The biology of hemodialysis. In: Hrl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, eds. Replacement for Renal Function by Dialysis. 5th ed. Norwell, Mass: Kluwer Academic Publishers; 2004:157-179. Chelamcharia M, Leypoldt JK, Cheung AK. Dialyzer membranes as determinants of the adequacy of dialysis. Semin Nephrol. 2005; 25:81-89. Clark WR, LeBlanc M, Levin N. The Acute Dialysis Quality Initiative, IV: membranes for CRRT. Adv Ren Replace Ther. 2002;9:265-267. Clark WR, Hamburger RJ, Lysaght MJ. Effect of membrane composition and structure on solute removal and biocompatibility in hemodialysis. Kidney Int. 1999;56:2005-2015. Johnson CA, Simmons WD. Dialysis of Drugs. City, State: Nephrology Pharmacy Associates Inc; 2002:1-9. De Vriese AS, Colardyn FA, Philippe JJ, Vanholder RC, De Sutter JH, Lameire NH. Cytokine removal during continuous hemofiltration in septic patients. J Am Soc Nephrol. 1999;10:846-853. Morgera S, Slowinski T, Melzer C, et al. Renal replacement therapy with high-cutoff hemofilters: impact of convection and diffusion on cytokine clearances and protein status. Am J Kidney Dis. 2004;43:444-453. Schindler R, Senf R, Frei U. Influencing the inflammatory response of hemodialysis patients by cytokine elimination using large pore membranes. Nephrol Dial Transplant. 2002;17:17-19. Clark WR, Winchester JF. Middle molecules and small-molecular-weight proteins in ESRD: properties and strategies for their removal. Adv Ren Replace Ther. 2003;10:270-278. Ronco C, Bellomo R. Nomenclature for renal replacement therapies. In: Ronco C, Bellomo R, eds. Critical Care Nephrology. Norwell, Mass: Kluwer Academic Publishers; 1998: 1169-1176. Cole L, Bellomo R, Davenport P, Tipping P, Ronco C. Cytokine removal during continuous renal replacement therapy: an ex vivo comparison of convection and diffusion. Int J Artif Organs. 2004;27:388-397. Tetta C, DIntini V, Bellomo R, et al. Extracorporeal treatments in sepsis: are there new perspectives? Clin Nephrol. 2003; 60:299-304. Schetz M, LeBlanc M, Murray PT. The Acute Dialysis Quality Initiative, VII: fluid composition and management in CRRT. Adv Ren Replace Ther. 2002;9:2282-2289. Clark WR, Turk JE, Kraus MA, Gao D. Dose determinants in continuous renal replacement therapy. Artif Organs. 2003;27:815-820. Uchino S, Fealy N, Baldwin I, Morimatsu H, Bellomo R. Pre-dilution vs post-dilution during continuous veno-venous hemofiltration: impact on filter life and azotemic control. Nephron Clin Pract. 2003;94:c83-c84. Ronco C, Bellomo R. Principles of solute clearance during continuous renal replacement therapy. In: Ronco C, Bellomo R, eds. Critical Care Nephrology. Norwell, Mass: Kluwer Academic Publishers; 1998:1213-1223. Ledebo I. Convective therapies, current status and perspectives. Ther Aphre Dial. 2005; 9:223-227. Ronco C, Levin NW. Mechanism of solute transport in extracorporeal therapies. Contrib Nephrol. 2005;149:10-17. Brunet S, Leblanc M, Geadah D, Parent D, Courteau S, Cardinal J. Diffusive and convective solute clearances during continuous renal replacement therapy at various dialysate and ultrafiltration flow rates. Am J Kidney Dis. 1999;34:486-492. Ronco C, Ricci Z, Bellomo R. Importance of increased ultrafiltration volume and impact on mortality: sepsis and cytokine story and the role for

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 77


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

CVVH. EDTNA ERCA J. 2002; suppl 2:13-18. 42. Kierdorf HP, Leue C, Arns S. Lactate- or bicarbonate-buffered solutions in continuous extracorporeal renal replacement therapies. Kidney Int Suppl. November 1999: S32-S36. 43. Ronco C, Brendolan A, Bellomo R. Dialysis techniques: continuous renal replacement therapies. In: Hrl WH, Koch KM, Lindsay RM, Ronco C, Winchester JF, eds. Replacement for Renal Function by Dialysis. 5th ed. Norwell, Mass: Kluwer Academic Publishers; 2004:699-708. 44. Martin RL. Continuous renal replacement therapies. In: Lynn-McHale Wiegand DJ, Carlson KK, eds. AACN Procedure Manual for Critical Care. 5th ed. St. Louis, Mo: WB Saunders Co; 2005:937-960. 45. Dunham CM. Clinical impact of continuous renal replacement therapy on multiple organ failure. World J Surg, 2001;25:669-676. 46. Wang H, Zhang ZH, Yan XW, et al. Amelioration of hemodynamics and oxygen metabolism by continuous venovenous hemofiltration in experimental porcine pancreatitis. World J Gastroenterol. 2004; 11:127-131. 47. Goldstein SL, Currier H, Graf Cd, Cosio CC, Brewer ED, Sachdeva R. Outcome in children receiving continuous venovenous hemofiltration. Pediatrics. 2001;107:1309-1312. 48. Foland JA, Fortenberry JD, Warshaw BL, et al. Fluid overload before continuous hemofiltration and survival in critically ill children: a retrospective analysis. Crit Care Med. 2004;32:1771-1776. 49. Venkataraman R, Kellum JA, Palevsky P. Dosing patterns for continuous renal replacement therapy at a large academic medical center in the United States. J Crit Care. 2002;17:246-250. 50. Luyckx NA, Bonavente JV. Dose of dialysis in acute renal failure. Semin Dial. 2004; 17:30-34. 51. Tobe SW, Aujla P, Walele AA, et al. A novel citrate anticoagulation protocol for CRRT using only commercially available solutions. J Crit Care. 2003;18:121-129. 52. Davenport A, Mehta S. The Acute Dialysis Quality initiative, VI: access and anticoagulation in CRRT. Adv Ren Replace Ther. 2002; 9:273-281. 53. Dorval M, Madore F, Geadeh D, LeBlanc M. Citrate anticoagulation monitoring: postfilter ACT or ionized calcium? Blood Purif. 2002;20:305323. 54. Oudemans-van Straaten HM, Wester JP, de Pont AC, Schetz MR. Anticoagulation strategies in continuous renal replacement therapy: can the choice be evidence based? Intensive Care Med. 2006;32:188-202. 55. Davenport A. Management of heparin-induced thrombocytopenia during continuous renal replacement therapy. Am J Kidney Dis. 1998;32:E3. 56. Hirsch J, Heddle N, Kelton JG. Treatment of heparin-induced thrombocytopenia: a critical review. Arch Intern Med. 2004;164:361-369. 57. Morabito S, Guzzo I, Solazzo A, Muzi L, Luciani R, Pierucci A. Continuous renal replacement therapies: anticoagulation in the critically ill at high risk of bleeding. J Nephrol. 2003;16:566-571. 58. Moffett DF, Moffett SB, Scauf L. Human Physiology: Foundations and Frontiers. St. Louis, Mo: Mosby Year Book Inc; 1993:398. 59. Kraft MD, Btaiche IF, Sacks GS, Kudsk KA. Treatment of electrolyte disorders in adult patients in the intensive care unit. Am J Health Syst Pharm. 2005;62:1663-1682. 60. Palsson R, Laliberte KA, Niles JL. Choice of replacement solution and anticoagulation in continuous venovenous hemofiltration. Clin Nephrol. 2006;65:34-42. 61. Cointault O, Kamar N, Bories P, et al. Regional citrate anticoagulation in venovenous haemodiafiltration using commercial solutions. Nephrol Dial Transplant. 2004; 19:171-178. 62. Rocktaschel J, Morimatsu H, Uchino S, Ronco C, Bellomo R. Impact of continuous venovenous hemofiltration in acid-base balance. Int J Artif Organs. 2003;26:19-25. 63. Morgera S, Scholle C, Voss G, et al. Metabolic complications during regional citrate anticoagulation in continuous venovenous hemodialysis: single-center experience. Nephron Clin Pract. 2004;97:c131-c136. 64. Mehta R. Anticoagulation for continuous renal replacement therapy. In: Ronco C, Bellomo R, eds. Critical Care Nephrology. Norwell, Mass: Kluwer Academic Publishers; 1998:1181-1202. 65. Baldwin I, Bridge N, Elderkin T. Nursing issues, practices, and perspectives for the management of continuous renal replacement therapy in the intensive care unit. In: Ronco C, Bellomo R, eds. Critical Care Nephrology. Norwell, Mass: Kluwer Academic Publishers; 1998:1199-1211. 66. Brouns R, De Deyn PP. Neurological complications in renal failure: a review. Clin Neurol Neurosurg. 2004;107:1-16. 67. Kyles DM. Coagulopathy and transfusion. In: Schell HM, Puntillo KA, eds. Critical Care Nursing Secrets. 2nd ed. St. Louis, Mo: Mosby Inc: 2006:432-445. 68. Gordon P. Post-resuscitation care. In: Kinney MR, Dunbar SB, BrooksBrunn JA, Molter N, Vitello-Cicciu JM. AACN Clinical Reference for Critical Care Nursing. 4th ed. St. Louis, Mo: Mosby Inc: 1998:199-217. 69. LeBlanc M, Bosc JY, Paganini EP, Canaud B. Central venous dialysis

78 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

70. 71.

72.

73. 74.

75.

76.

77.

78.

79.

80.

81.

82.

83.

84.

85.

86.

catheter dysfunction. Adv Ren Replace Ther. 1997;4:377-389. Balta Salai P. Hemodialysis. In: Parker J, ed. Contemporary Nephrology Nursing. Pitman, NJ: Anthony J Jannetti Inc; 1998:527-576. Giuliano KK, Pysznik EE. Renal replacement therapy in critical care: implementation of a unit-based continuous venovenous hemodialysis program. Crit Care Nurse. February 1998;18:40-51. Hoste EA, Blot SI, Lameire NH, Vanholder RC, De Bacquer D, Colardyn FA. Effect of nosocomial bloodstream infection on the outcome of critically ill patients with acute renal failure treated with renal replacement therapy. J Am Soc Nephrol. 2004;15:454-462. Druml W. Metabolic aspects of continuous renal replacement therapies. Kidney Int Suppl. November 1999:S56-S61. Jones SK. Loss of body heat during continuous venovenous hemodialysis (CVVHD) in critically ill patients. Blood Purif. 2003; 21:183-207. Yagi N, LeBlanc M, Sakai K, Wright EJ, Paganini EP. Cooling effect of continuous renal replacement therapy in critically ill patients. Am J Kidney Dis. 1998;32:1023-1030. Rickard CM, Couchman BA, Hughes M, McGrail MR. Preventing hypothermia during continuous veno-venous haemodiafiltration: a randomized controlled trial. J Adv Nurs. 2004;47:393-400. Wolberg AS, Meng ZH, Monroe DM III, Hoffman M. A systemic evaluation of the effect of temperature on coagulation enzyme activity and platelet function. J Trauma. 2004;56:1221-1228. Bent P, Tan HK, Bellomo R, et al. Early and intensive continuous hemofiltration for severe renal failure after cardiac surgery. Ann Thorac Surg. 2001;71:832-837. von Bommel RF. Renal replacement therapy for acute renal failure on the intensive care unit: coming of age? Neth J Med. 2003; 61:239-248. Gettings LG, Reynolds HN, Scalea T. Outcome in post-traumatic acute renal failure when continuous renal replacement therapy is applied early vs late. Intensive Care Med. 1999;25:805-813. Bouman CS, Oudemans-van Straaten HM, Tijssen JG, Zandstra DF, Kesecioglu J. Effects of early high-volume continuous hemofiltration on survival and recovery of renal function in intensive care patients with acute renal failure: a prospective, randomized trial. Crit Care Med. 2002;30:2205-2211. Paganini E, Depner T, Wensley D. The Acute Dialysis Quality Initiative, III: solute control (treatment dose). Adv Ren Replace Ther. 2002;9:260-264. Palevsky PM, OConnor T, Zhang JH, Star RA, Smith MW. Design of the VA/NIH Acute Renal Failure Trial Network (ATN) study: intensive versus conventional renal support in acute renal failure. Clin Trials. 2005;2:423-435. Ronco C, Bellomo R, Homel P, et al. Effects of different doses in continuous veno-venous haemofiltration on outcomes of acute renal failure: a prospective randomised trial. EDTNA ERCA J. 2002;Suppl 2;7-12. Kumar VA, Craig M, Depner TA, Yeun JY. Extended daily dialysis: a new approach to renal replacement for acute renal failure in the intensive care unit. Am J Kidney Dis. 2000;36:294-300. Kielstein JT, Kretschmer U, Ernst T, et al.

http://ccn.aacnjournals.org

CRITICALCARENURSE Vol 27, No. 2, APRIL 2007 79


Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

Efficacy and cardiovascular tolerability of extended daily dialysis in critically ill patients: a randomized controlled study. Am J Kidney Dis. 2004;43:342-349. 87. OReilly P, Tolwani A. Renal replacement therapy III: IHD, CRRT, SLED. Crit Care Clin. 2005;21:367-378. 88. Honore PM, Jamez J, Wauthier M, et al. Prospective evaluation of short-term, highvolume isovolemic hemofiltration on the hemodynamic course and outcome in patients with intractable circulatory failure resulting from septic shock. Crit Care Med. 2000;28:3581-3587. 89. Ratanarat R, Brendolan A, Piccinni P, et al. Pulse high-volume haemofiltration for treatment of severe sepsis: effects on hemodynamics and survival. Crit Care. 2005; 9:R294-R302. 90. Piccinni P, Dan M, Barbacini S, et al. Early isovolaemic haemofiltration in oliguric patients with septic shock. Intensive Care Med. 2006;32:80-86. 91. Schetz M. Non-renal indications for continuous renal replacement therapy. Kidney Int. Suppl. November 1999;S88-S94. 92. Honore PM, Matson JR. Hemofiltration, adsorption, sieving and the challenge of sepsis therapy design. Crit Care. 2002;6:394-396. 93. Ronco C, Inguaggiato P, DIntini V, et al. The role of extracorporeal therapies in sepsis. J Nephrol. 2003;16(suppl 7):S34-S41. 94. Kellum JA, Song M, Ventakaraman R. Hemoadsorption removes tumor necrosis factor, interleukin 6, and interleukin 10, reduces nuclear factor DNA binding, and improves short-term survival in lethal endotoxemia. Crit Care Med. 2004;32:801-805. 95. Song M, Winchester J, Albright RL, Capponi VJ, Choquette MD, Kellum JA. Cytokine removal with a novel adsorbent polymer. Blood Purif. 2004;22:428-434. 96. Kellum JA, Ventakaraman R. Application of blood purification to non-renal organ failure. Int J Artif Organs. 2005;28:445-449. 97. Winchester JF, Silborzweig J, Ronco C, et al. Sorbents in acute renal failure and end-stage renal disease: middle molecule and cytokine removal. Blood Purif. 2004;22:72-77. 98. Bellomo R, Tetta C, Brendolan A, Ronco C. Coupled plasma filtration adsorption. Blood Purif. 2002;20:289-292. 99. Berlot G, Tomasini A, Silvestri L, Gullo A. Plasmapheresis in the critically ill patient. Kidney Int Suppl. 1998;66:S178-S181. 100. Ronco C, Ricci Z, Brendolan A, Bellomo R, Bedogni F. Ultrafiltration in patients with hypervolemia and congestive heart failure. Blood Purif. 2004;22:150-163. 101. Grapsa E, Alexopoulos GP, Margari Z, Terrovitis JV, Kontoyannis DA, Nanas JN. Ultrafiltration in the treatment of severe congestive heart failure. Int Urol Nephrol. 2004;36:269-272. 102. Clark WR, Paganini E, Weinstein D, Bartlett R, Sheinfeld G. Ronco C. Extracorporeal ultrafiltration for acute exacerbations of chronic heart failure: report from the Acute Dialysis Quality Initiative. Int J Artif Organs. 2005;28:466-476. 103. Humes HD, Weitzel WF, Bartlett RH, et al. Initial clinical results of the bioartificial kidney containing human cells in ICU patients with acute renal failure. Kidney Int. 2004; 66:1578-1588. 104. Tiranathanagul K, Eiam-Ong S, Humes HD. The future of renal support: high-flux dialysis to bioartificial kidneys. Crit Care Clin.

2005;21:379-394. 105. de Francisco AL, Pinera C. Challenges and future of renal replacement therapy. Hemodial Int. 2006;10(suppl 1):S19-S23. 106. Augustine JJ, Sandy D, Seifert TH, Paganini EP. A randomized controlled trial comparing intermittent with continuous dialysis in patients with ARF. Am J Kidney Dis. 2004; 44:1000-1007. 107. Teehan GS, Liangos O, Jaber BL. Update on dialytic management of acute renal failure. Intensive Care Med. 2003;18:130-138.

80 CRITICALCARENURSE Vol 27, No. 2, APRIL 2007

http://ccn.aacnjournals.org

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

CE Test

Test ID C0722: Continuous Renal Replacement Therapy in the Adult Intensive Care Unit: History and Current Trends Learning objectives: 1. Identify indications for intermittent dialysis and continuous renal replacement therapy (CRRT) 2. Review variations and advantages and disadvantages of CRRT 3. Examine potential complications of CRRT 1. What is the mortality rate associated with acute renal failure? a. 0% to 15% b. 10% to 25% c. 25% to 90% d. 90% to 100% 2. What type of medication is used to manage acute renal failure? a. Loop diuretics b. Ace inhibitors c. Angiotensin blockers d. Beta blockers 3. What is the goal of ideal treatment of acute renal failure? a. Return to adequate state of health by periodic removal of wastes and excess fluid b. Mimic efficacy of native kidney and not delay recovery of renal function c. Return to maximum state of health by removal of previous 24-hour fluid intake d. Mimic efficacy of native bladder and urethra and not delay recovery of bladder function 4. How does intermittent dialysis affect the kidney in a critically ill patient? a. Potential for ischemia of ureters and bladder-causing spasm b. Potential for ischemia of nephrons c. Potential for ischemia of abdominal wall d. No ischemia since dialysis works effectively to safe guard nephrons 5. How are wastes removed from the blood with CRRT? a. Convection and diffusion b. Conduction and transfusion c. Convection and transfusion d. Conduction and diffusion 6. How is f luid removed from the blood with CRRT? a. Diuretics b. Transfusion c. Ultra filtration d. Conduction 7. What was a major drawback to continuous arteriovenous hemof iltration? a. Use of large catheter in a major artery b. Required arteriovenous fistula c. Required peritoneal catheter d. Required large catheter in major vein 8. What types of substances cannot pass through a hemof ilter (max pore size of 50kd)? a. Urea b. Electrolytes c. White blood cells d. Vitamins 9. What is a benef it of predilution f luids? a. Removes wastes b. Provides electrolytes c. Provides ultra filtrate volume d. Provides continuous flush for hemofilter 10. How does continuous venovenous hemodialysis (CVVHD) differ from continuous venovenous hemof iltration? a. Dialysate is infused into blood in CVVHD b. Dialysate is infused into the outside compartment of the dialyzer in CVVHD c. Blood is infused into dialysate in CVVHD d. Blood is infused into the outside compartment of the dialyzer in CVVHD 11. What type of CRRT is best for f luid removal if the patient does not have azotemia? a. Continuous venovenous hemodiafiltration b. Continuous venovenous hemofiltration dialysis c. Continuous venovenous hemofiltration d. Slow continuous ultra filtration 12. What is a complication of CRRT? a. Gallstones b. Gout c. Hypoxia d. Hypothermia

Test answers: Mark only one box for your answer to each question. You may photocopy this form.

1. K a Kb Kc Kd

2. K a Kb Kc Kd

3. K a Kb Kc Kd

4. K a Kb Kc Kd

5. K a Kb Kc Kd

6. K a Kb Kc Kd

7. K a Kb Kc Kd

8. K a Kb Kc Kd

9. K a Kb Kc Kd

10. K a Kb Kc Kd

11. K a Kb Kc Kd

12. K a Kb Kc Kd

Test ID: C0722 Form expires: April 1, 2009 Contact hours: 1.5 Fee: $11 Passing score: 9 correct (75%) Category: A Test writer: Jane Baron, RN, CS, ACNP

Program evaluation
Objective 1 was met Objective 2 was met Objective 3 was met Content was relevant to my nursing practice K My expectations were met K This method of CE is effective for this content K The level of difficulty of this test was: K easy K medium K difficult To complete this program, it took me hours/minutes. Yes K K K No K K K K K K

Name Address City Country E-mail RN Lic. 1/St Payment by: Card # Signature K Visa K M/C RN Lic. 2/St K AMEX Phone

Member #

State

ZIP

Mail this entire page to: AACN 101 Columbia Aliso Viejo, CA 92656 (800) 899-2226

K Discover

K Check Expiration Date

The American Association of Critical-Care Nurses is accredited as a provider of continuing nursing education by the American Nurses Credentialing Centers Commission on Accreditation. AACN has been approved as a provider of continuing education in nursing by the State Boards of Nursing of Alabama (#ABNP0062), California (#01036), and Louisiana (#ABN12). AACN programming meets the standards for most other states requiring mandatory continuing education credit for relicensure.

Downloaded from ccn.aacnjournals.org by guest on May 26, 2011

You might also like