FEDERAL SPECIFICATION NITROGEN, TECHNICAL

Federal Specification BB-N-411C, dated January 3, 1973, is hereby canceled and has been replaced by Commercial Item Description A-A-59503.

MILITARY INTERESTS: Custodians Army - AV Navy - SH Air Force - 68 Reviewers Army - AR, EA, MD Navy - AS, MC, OS, YD Other - DS

CIVIL AGENCY COORDINATING ACTIVITY: GSA-FSS Preparing activity: DLA-GS (Project 6830-1040)

AMSC N/A

FSC 6830

DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.

BB-N-411C January 3, 1973 SUPERSEDING FED. SPEC. BB-N-4116 September 10, 1964 FEDERAL SPECIFICATION NITROGEN, TECHNICAL This specification was approved by the Commissioner, Federal Supply Services, General Services Administration, for use of all Federal Agencies. 1. 1.1 1.2 SCOPE AND CLASSIFICATION Scope. This specification covers gaseous and liquid nitrogen.

Classification.

1.2.1 Types, grades, and classes. The nitrogen shall be of the following types, grades, and classes, as specified (see 6.2): Type I Type II Grade A Grade B Grade C Class 1 Class 2 2. Gaseous. Liquid. 99.95 percent pure. 99.50 percent pure. 99.50 percent pure, moisture content not specified (type I only). Oil free. Oil tolerant (Type I only) (see 6.3).

APPLICABLE DOCUMENTS

2.1. Specifications and standards. The following specifications and standards of the issue in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent specified herein: Federal Specification RR-C-901 Federal Standard FED. STD. No. 123 - Marking for Domestic Shipment (Civilian Agencies). - Cylinders, Compressed Gas: With Valve of Plug and Cap; ICC 3AA.

FSC 6830

BB-N-411C (Activities outside the Federal Government may obtain copies of Federal Specifications, Standards, and Handbooks as outlined under General Information in the Index of Federal Specifications and Standards and at the prices indicated in the Index. The Index, which includes cumulative monthly supplements as issued, is for sale on a subscription basis by the Superintendent of Documents, U.S. Government Printing Office, Washington, DC 20402.) (Single copies of this specification and other Federal Specifications required by activities outside the Federal government for bidding purposes are available without charge from Business Service Centers at the General Services Administration Regional Offices in Boston, New York, Washington, DC, Atlanta, Chicago, Kansas City, MO, Fort Worth, Denver, San Francisco, Los Angeles, and Seattle, WA.) (Federal Government activities may obtain copies of Federal Specifications, Standards, and Handbooks and the Index of Federal Specifications and Standards from established distribution points in their agencies.) Military Specifications. MIL-V-2 MIL-T-704 Military Standards. MIL-STD-101 MIL-STD-105 MIL-STD-129 MIL-STD-147 - Color Code for Pipelines and for Compressed Gas Cylinders. - Sampling Procedures and Tables for Inspection by Attributes. - Marking for Shipment and Storage. - Palletized and containerized Unite Loads 40" x 48" Pallets, Skids, Runners, or Pallet-Type Base. - Valve; Cylinder, Gas. - Treatment and Painting of Material

(Copies of Military Specifications and Standards required by suppliers in connection with specific procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 2.2 Other publications. The following documents form a part of this specification to the extent specified herein. Unless otherwise indicated, the issue in effect on date of invitation for bids or request for proposal shall apply. DEPARTMENT OF TRANSPORTATION 49 CFR 171-190 - Code of Federal Regulations. (Application for copies should be addressed to the Superintendent of Documents, Government Printing Office, Washington, DC 20402.) 2

BB-N-411C NATIONAL BUREAU OF STANDARDS Handbook H28 - Screw-Thread Standards for Federal Services Application for copies should be addressed to the Superintendent of Documents, Government Printing Office, Washington, DC 20402.) COMPRESSED GAS ASSOCIATION, INC. CGA Specification G-10.1 CGA Pamphlet C-6 CGA Pamphlet C-1 Commodity Specification for Nitrogen (first edition, dated 1969). Standards for Visual Inspection of Compressed Gas Cylinders. Methods for Hydrostatic Testing of Compressed Gas Cylinder.

(Application for copies should be addressed to the Compressed Gas Association, Inc., 500 Fifth Avenue, New York, NY 10036.) AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). F310-70 Sampling Cryogenic Aerospace Fluids

(Application for copies should be addressed to the American Society for Testing and Materials, 1916 Race Street, Philadelphia, PA 19103.) 3. 3.1 REQUIREMENTS Materials. The nitrogen shall conform to table I. Table I. Properties of Nitrogen, Technical. Property Requirement Grade A Grade B Grade C Purity, min. percent by volume 99.95 99.50 99.50 Oxygen, max. percent by volume 0.05 0.50 0.50 Moisture, max milgm H2O/1 of gas 0.02 0.02 * Odor (see note 2) None None None * No limiting characteristics

BB-N-411C Notes: 1. 2. Purity is the percent nitrogen and includes trace quantities of argon, neon, and helium. All types and grades of nitrogen shall be free of oil contamination and shall have a total hydrocarbon level less than 50 ppm as methane by volume detectable by odor or by test when specified (see 4.4.2.5). Nitrogen, type I and type II shall be produced in processes utilizing liquefaction of air and compressed by a cryogenic liquid converter or a water sealed or dry sealed compressor. The type I nitrogen shall contain no solid particles whose maximum dimensions are greater than 50 microns. This shall be assumed to have been assured by the use of a 10 micron or better nominal filter at or close to the cylinder charging manifold (see 6.4.).

3. 4.

3.2

Containers and valves.

3.2.1 Type I, gaseous. Unless otherwise specified herein, the type I gaseous nitrogen shall be contained in Government-furnished cylinders (see 6.5) which are in accordance with 49 CFR 171-190 and equipped with valves having outlet connections in accordance with Handbook H28 or MIL-V-2 (see 6.3). When specified (see 6.2), new cylinders shall be furnished to the Government by the gas supplier. The cylinders shall be in accordance with RR-C-901 and shall be equipped with valves in accordance with MIL-V-2. When specified (see 6.2.), the gaseous nitrogen shall be contained in supplier owned, DOT approved containers. 3.2.2 Type II, liquid. Type II, liquid nitrogen shall be contained in either supplier owned or Government owned insulated containers or tank trucks as specified (see 6.2). Containers shall be in accordance with 49 CFR 171-190. 3.3 Container maintenance. Unless Otherwise specified (see 6.2), containers that require maintenance shall be precessed by the supplier for serviceability to meet the requirements of this specification and 49 CFR 171-190 (see 6.6). 3.3.1 Processing type I nitrogen cylinder.

3.3.1.1 External inspection. Each cylinder and valve shall be examined for external corrosion or damage in accordance with CGA Pamphlet C-6, and for clarity of markings in accordance with 49 CFR 171-190. The area of the cylinder and valve shall be inspected for contamination. Cylinders having excessive corrosion, physical damage, evidence of exposure to fire or

BB-N-411C evidence of a contaminate that cannot be removed by the supplier's standard handling procedures, or cylinders having a damaged or incorrect valve, or with unclear or incorrect marking shall not be refilled. When the contract or order does not provide for reconditioning of the Government-owned cylinder and valve, any defective cylinder shall be returned unfilled. 3.3.1.2. Hydrostatic testing. Each cylinder shall be inspected to determine the last date of hydrostatic testing. Unless otherwise specified herein, cylinders that have not been hydrostatically tested within 5 years prior to the intended fill date shall be hydrostatics tested and clearly marked in accordance with CGA Pamphlet C-1. Each cylinder subjected to the hydrostatic test shall be dried as specified in 3.3.1.3. When the contract or order does not specify hydrostatic testing, any cylinder requiring hydrostatic test shall be returned to the Government unfilled. When specified (see 6.2), hydrostatic retest period shall be 10 years. 3.3.1.3 Cylinder drying. When required, all cylinders shall be dried by either the hot-gas purging method specified in 3.3.1.3.1, or by the evacuation method specified in 3.3.1.3.2. 3.3.1.3.1 Hot-gas purging method. The cylinder shall be dried by the cylinder valve, inserting a tube extending approximately to the closed end of the cylinder, and passing clean, hot (300 deg. to 350 deg. F.) dry oil free air or nitrogen through the tube until the temperature of the open end reaches 180 deg. F., or the escaping gas reaches 215 deg. to 225 deg. F. The cylinder shall be inverted with the open end down for this hot purge so that the longitudinal axis of the cylinder is not more than 45 degrees from vertical. The supplier's standard drying process shall be acceptable, provided it can be demonstrated that the drying process has eliminated the moisture from the treated cylinder determined by the dewpoint of the escaping gas becoming constant with that of the dry purging gas. 3.3.1.3.2 Evacuation method. The cylinder shall be dried by attaching a vacuum pump to the cylinder valve outlet, opening the valve, and heating the cylinder to approximately 180 deg. F. in an oven or hot water bath while evacuating the cylinder to a pressure of 3 inches of mercury (Hg) or better. 3.3.1.4 Residual pressure and odor. The cylinders shall be inspected for resident pressure and sniff-tested for odor. Any cylinder having no residual pressure shall be pressurized to not less than 25 psi of nitrogen pressure and checked for odor and any condensed contaminants. Any cylinder

BB-N-411C having an odor or containing condensed contaminants which can not be removed by the supplier's standard handling procedure shall not be refilled. When the contract or order does not provide for reconditioning of the Government owned cylinders, the cylinders shall be returned unfilled. 3.3.1.5 Hammer test. During the inspection process, each cylinder shall be subjected to hammer testing for progressive corrosion or for the presence of contaminants which are not odor bearing. Cylinders that do not resound clearly shall not be refilled. When the contract or order does not provide for reconditioning of the Government-owed cylinders, the cylinders shall be returned unfilled. 3.3.1.6 Cylinder evacuation. Prior to filling, all cylinders shall be evacuated to a pressure of mercury (Hg) or better. 3.3.2 Painting. Government-furnished containers for nitrogen requiring repainting shall be cleaned, treated, and painted in accordance with MIL-T-704. The Government-furnished cylinders for type I gaseous nitrogen which are repainted shall be color coded and marked in accordance with MIL-STD-101. 3.3.3 Valves. Unless otherwise specified (see 6.2), replace valves for defective valves in Government-furnished cylinders for type I gaseous nitrogen shall be supplier furnished and installed and shall be in accordance with MIL-V-2. 3.4 Capacity. Containers of gaseous nitrogen shall be filled to the rated service pressure. The settled pressure in a filled container shall be within 25 pounds per square inch gage (psig) pressure of the pressure that corresponds to the settled container temperature as shown on Table II. Unless otherwise specified (see 6.2), containers of liquid nitrogen shall be filled to the rated capacity. Containers shall be filled in accordance with 49 CFR 171-190.

BB-N-411C TABLE II. Pressure-Temperature Conversion Chart. Settled pressure (expressed in psig) which corresponds to the rated service pressure for a container filled to capacity. Settled Container service pressure--gaseous nitrogen Temp of 1800 2015 2200 2265 2400 3500 -50 1270 1207 1528 1574 1653 2385 -48 1279 1417 1540 1588 1667 2404 -46 1288 1427 1552 1601 1680 2423 -44 1297 1437 1564 1614 1693 2442 -42 1306 1447 1575 1627 1707 2460 -40 1315 1457 1585 1630 1720 2479 -38 1342 1468 1597 1643 1733 2497 -36 1338 1478 1609 1655 1746 2516 -34 1342 1488 1621 1667 1758 2534 -32 1351 1499 1632 1678 1771 2552 -30 1360 1509 1643 1689 1783 2571 -28 1369 1519 1654 1701 1795 2589 -26 1378 1529 1665 1713 1807 2608 -24 1387 1539 1676 1724 1819 2627 -22 1396 1550 1688 1735 1831 2645 -20 1405 1560 1699 1746 1843 2664 -18 1414 1570 1710 1757 1855 2683 -16 1423 1580 1722 1768 1868 2711 -14 1432 1590 1733 1780 1881 2730 -12 1441 1601 1744 1792 1893 2748 -10 1449 1611 1755 1804 1905 2757 - 8 1458 1621 1767 1815 1918 2776 - 6 1467 1631 1778 1827 1930 2795 - 4 1476 1641 1789 1839 1943 2813 - 2 1484 1651 1800 1850 1955 2832 0 1494 1661 1811 1861 1968 2851 + 2 1503 1671 1823 1873 1980 2869 4 1511 1682 1833 1885 1993 2888 6 1520 1692 1845 1896 2005 2906 8 1528 1702 1856 1908 2017 2925 10 1538 1712 1867 1920 2030 2943 12 1546 1722 1878 1931 2042 2962 14 1555 1732 1889 1942 2055 2980 16 1563 1742 1901 1954 2067 2999 18 1573 1753 1912 1966 2079 3017 20 1582 1763 1923 1978 2092 3036 22 1590 1773 1934 1989 2104 3055 24 1599 1783 1945 2000 2116 3073 26 1608 1793 1956 2013 2129 3092 28 1616 1803 1967 2024 2141 3111 30 1625 1814 1978 2035 2154 3129 7

BB-N-411C TABLE II. Pressure-Temperature Conversion Chart. Settled pressure (expressed in psig) which corresponds to the rated service pressure for a container filled to capacity. Settled Container service pressure--gaseous nitrogen Temp of 1800 2015 2200 2265 2400 3500 32 1634 1824 1990 2046 2166 3148 34 1643 1834 2001 2058 2178 3167 36 1652 1844 2012 2070 2190 3185 38 1660 1854 2023 2082 2203 3204 40 1669 1864 2034 2093 2215 3222 42 1677 1874 2045 2105 2227 3241 44 1686 1884 2056 2116 2240 3260 46 1695 1894 2068 2128 2252 3278 48 1704 1904 2079 2139 2264 3297 50 1713 1914 2090 2150 2276 3316 52 1721 1924 2101 2162 2289 3334 54 1730 1934 2112 2173 2301 3353 56 1739 1944 2123 2185 2313 3371 58 1748 1954 2134 2196 2326 3389 60 1756 1964 2145 2208 2338 3408 62 1765 1975 2156 2219 2350 3426 64 1774 1985 2167 2230 2362 3445 66 1782 1995 2178 2242 2375 3463 68 1791 2005 2189 2253 2387 3482 70 1800 2015 2200 2265 2400 3500 72 1809 2025 2211 2279 2412 3519 74 1817 2035 2222 2288 2424 3537 76 1826 2045 2233 2300 2437 3556 78 1834 2055 2244 2310 2449 3574 80 1843 2065 2256 2322 2461 3598 82 1851 2075 2267 2333 2473 3601 84 1861 2085 2278 2345 2486 3620 86 1869 2095 2289 2357 2498 3639 88 1878 2105 2300 2368 2510 3658 90 1887 2115 2311 2379 2522 3686 92 1896 2225 2322 2390 2534 3705 94 1904 2135 2333 2402 2546 3723 96 1912 2145 2344 2414 2559 3741 98 1921 2154 2355 2425 2571 3760 100 1930 2164 2366 2436 2583 3778 102 1939 2174 2377 2448 2595 3796 104 1948 2184 2388 2459 2608 3814 106 1956 2194 2399 2470 2620 3832 108 1964 2204 2410 2482 2631 3850 110 1973 2214 2421 2494 2644 3868 8

BB-N-411C TABLE II. Pressure-Temperature Conversion Chart. Settled pressure (expressed in psig) which correspond to the rated service pressure for a container filled to capacity. Settled Container service pressure--gaseous nitrogen Temp of 1800 2015 2200 2265 2400 3500 112 1982 2224 2432 3505 2656 3887 114 1991 2234 2443 2516 2669 3905 116 2000 2244 2454 2528 2680 3924 118 2008 2254 2465 2539 2693 3942 120 2017 2263 2476 2550 2705 3961 122 2025 2273 2486 2561 2718 3979 124 2034 2283 2498 2573 2729 3996 126 2043 2293 2509 2584 2741 4014 128 2051 2303 2520 2595 2754 4032 130 2060 2313 2530 2607 2766 4049 132 2069 2323 2541 2618 2778 4067 134 2078 2333 2553 2630 2790 4048 136 2086 2342 2564 2641 2803 4101 138 2094 2352 2574 2652 2814 4119 140 2103 2362 2585 2663 2826 4136 142 2111 2372 2596 2675 2839 4154 144 2120 2381 2608 2686 2851 4172 146 2129 2391 2619 2697 2863 4189 148 2138 2401 2630 2709 2875 4207 150 2147 2411 2641 2720 2887 4224 3.5 4. Leakage. Containers and valve shall not leak after being filled.

QUALITY ASSURANCE PROVISIONS

4.1 Responsibility for inspection. Unless otherwise specified in the contract or purchase order, the supplier is responsible for the performance at all inspection requirements as specified herein. Except as otherwise specified in the contract or order, the supplier may use his own are any other facilities suitable for the performance of the inspection requirements specified herein, Unless disapproved by the Government. The Government reserves the right to perform any of the inspections set forth on the specification where such inspections are deemed necessary to assure supplies and services conform to prescribed requirements. 4.2 Classification of inspection. Inspection shall be classified as follows: (a) (b) Quality conformance inspection (see 4.3). Inspection of preparation for delivery (see 4.5). 9

BB-N-411C 4.3 Quality conformance inspection. Inspection lot.

4.3.1

4.3.1.1 Type I, gaseous. A lot shall consist of all cylinders filled from the some source during a consecutive 24 hour period. A source is considered to be either an individual nitrogen producing process, or an individual storage container to which no nitrogen is added after the initial filling. Once nitrogen is added to a storage container from which cylinders are being filled, that storage container is prescribed as being a different source. 4.3.1.1.1 Sampling, Type 1. Sampling shall be from filled cylinders which shall be selected in accordance with MIL-STD-105, inspection level S-4. 4.3.1.2 Type II liquid. Each filled container shall be considered a lot.

4.3.1.2.1 Sampling, type II. Sampling of type II liquid oxygen shall be in accordance with ASTM F310-70 Standard Method of Sampling Cryogenic Aerospace Fluids. 4.3.1.3 Sampling, small containers. Type II nitrogen shall be drawn from each container. When specified (see 6.2), bulk liquid nitrogen used exclusively for filling an entire order of small liquid containers may be sampled and tested immediately prior to the actual transfer in lieu of testing samples from the small liquid containers. 4.3.2 Examination. Each container shall be examined as specified in 4.4.1. Presence of one or more defects shall be cause for rejection. 4.3.3 Tests.

4.3.3.1 Individual. Each container shall be tested as specified in 4.4.2.4 for leakage. Failure of the test shall be cause for rejection. 4.3.3.2 Samples. Samples selected in accordance with 4.3.1.1.1 and 4.3.1.2.1 shall be tested in accordance with 4.4.2. AQL shall be 2.5 percent defective. The nitrogen sample for testing shall be representative of the type I nitrogen supplied in the cylinders. 4.4 Inspection procedure.

4.4.1 Examination. Each container of nitrogen shall be examined as specified herein for the following defects:

10

BB-N-411C 101. Container or valve not as specified. 102. Container maintenance not as specified. 103. Capacity not as specified. 4.4.2 Tests. Before any test, sufficient nitrogen shall be permitted to flow to displace any other gas present in the test equipment lines. Liquid nitrogen shall be in vapor form for the tests. 4.4.2.1 Purity and oxygen. The purity and the oxygen content, percentages by volume, shall be determined by Gas Chromatograph as outlined in 4.4.2.1.1 or by one of the oxygen analysis methods specified in section 5.5 of CGA Specification G-10.1, with the following provisions: (a) (b) (c) (d) The comparison tube apparatus described in 5.5.7 of MA G-10.1 shall not be applicable. Analytical instruments shall be appropriately calibrated and operated within the maximum range as specified in CGA G-10.1. Orsat apparatus, if used, shall be such that accuracy shall be at least plus or minus 0.01 percent by volume for grade A nitrogen and at least plus or minus 0.1 percent by volume for grades B or C nitrogen. In case of dispute the gas, chromatograph method shall be the reference standard.

Purity and oxygen content not as specified in 3.1 shall constitute failure of this test. 4.4.2.1.1 Gas chromatograph apparatus method. The purity of nitrogen shall be determined in accordance with the following gas chromatographic procedures: (a) Apparatus - A gas chromatograph having the following minimum capabilities is required: (1) (2) (3) (4) (b) Temperature control systems capable of maintaining the chromatographic column and detector at the prescribed temperature +/- 1 deg. C. Gas sampling valve. Not wire or thermistor type thermal conductivity detector. Recorder or other readout.

Materials - The following materials are required: (1) Chromatographic column - A tubular column constructed of aluminum, copper or stainless steel, 6 feet long by 1/4 inch outside diameter. (Optimum column size will vary between instruments). The column is to be packed with activated Molecular Sieve 5A or 13X.

11

BB-N-411C (2) (3) Carrier Gas - dry helium of a minimum of 99-95 volume percent purity. Standards - Appropriate standards containing 0.05% by volume oxygen (Grade A) and 0.50% by volume oxygen (Grade B) may be obtained from Gas Supply Facilities or prepared in the laboratory.

(c)

Analysis Parameters - The following general analysis conditions are recommended. The parameters will between instruments. (1) (2) (3) (4) (5) Column temperature - 60 deg. C isothermal Detector temperature (when separate from column) - 150 deg. C Sample size - 0.5cc or as appropriate for instrument Carrier gas flow - 20 ml per minute (will vary with instrument) Detector current - sufficient to easily detect the oxygen requirement of Grade A or B.

(d) (e)

Constituent identification - Employing the operating conditions specified, oxygen followed by nitrogen will elute from the column within 5 minutes. Quantitative measurement - Quantitative measurement of a component concentration depends upon a determination of the peak height or peak area of the component's chromatograph peak. For the determination of oxygen, the peak is sufficiently sharp to recommend the use of peak height in lieu of peak area. To obtain the percent concentration of the oxygen component, a direct comparison is made between the peak height of the oxygen and that of a standard containing a known concentration of oxygen. Both the sample and the standard must be analyzed under identical operating conditions. The volume percent of the oxygen component may be calculated by using the following equation: X % (vol) O2 in Std

% (Vol) O2 - Peak Height O2 in Sample Peak Height O2 in Std

4.4.2.2 Moisture content. The moisture content shall be determined by either the accelerated gravimetric method as specified in 4.4.2.2.1. or one of the moisture content analysis methods specified in section 5.3 of CGA G-10.1 with the following provisions:

12

BB-N-411C (a) (b) The condensed water measurement Method described in section 5.3.1 of CGA C-10.1 is not applicable. Analytical instruments shall be appropriately calibrated and operated within the maximum range as specified in CGA G-10.1. Analytical apparatus shall be such that measurement can be made with a precision of at least plus or 0.002 milligram water per liter of gas. The 0.02 milligram water per liter of gas is equivalent to 26.3 parts per million water vapor by volume, and also to a dewpoint of minus 63.5 deg. F.

(c)

Moisture content not as specified in 3.1 shall constitute failure of this test. 4.4.2.2.1 Accelerated gravimetric method. The moisture content shall be determined by measurement of increase in weight of phosphorus pentoxide (P2O5 when subjected to a flow of a measured volume of nitrogen in the following procedure: (a) The container to be tested shall be inverted in a suitable rack. The container shall be connected to the test apparatus by means of a length of bent, seamless, corrosion-resisting steel tubing, and a high-pressure union needle valves and a glass-to-metal joint. (No rubber connections shall be used; a sleeve Joint secured with "tygon" or equivalent is acceptable). The apparatus shall consist of three U-tube absorbers-in series, each 4 inches high and 1/2 inch in diameter, containing phosphorous pentoxide on glass wool and connected through a water-saturator to a calibrated wet-test meter of 1/20-cubic-foot size equipped with a 1-liter dial. A mercury safety valve shall be connected between the lower-pressure outlet of the needle valve and the first absorber. The steel tube shall be so fabricated that it will first pass through a water bath at room temperature and then into a second bath also at room temperature. The needle valve connecting cylinder to the absorber shall be flushed with nitrogen so that only gas discharged from the cylinder will pass through the absorber. The absorbers shall be brought to constant weight in a steam of dry nitrogen before they are weighed so they will be at all times filled with nitrogen. Before each weighing of the opened absorbers, they shall be opened momentarily to the air, closed, and cleaned. One-hundred liters of gaseous nitrogen shall be discharged through the apparatus at a rate not to exceed 0.4 liter per minute.

(b)

13

BB-N-411C (c) The gas volume corresponding to the gain in weight shall be calculated to 760 mm. of mercury and 70 deg. F. The moisture content shall be computed in term of milligrams per liter.

4.4.2.3 Odor. Filled containers of nitrogen shall be sniff-tested. A sniff-test in made by wafting a low level of effluent vapor from a liquid nitrogen container or escaping gas from a nitrogen cylinder pot the tester's nostrils with a hand or a card. The detection of many odor in the effluent gas from any container shall constitute failure of this test. 4.4.2.4 Leakage. All containers after filling shall be tested for leakage by applying a soap solution to all portions of the valve and the junction of the valve and cylinder. Care shall be taken to ensure that the solution utilized does not contaminate the valve outlet. Any leakage as evidenced by bubbling of the soap solution shall constitute failure of this test. 4.4.2.5 Total hydrocarbon content. When specified (see 6.2), a total hydrocarbon content shall be determined by means of one of the total hydrocarbon methods specified in section 5.5 of CGA specification G-10.1. 4.5 Inspection of preparation for delivery. Each container of nitrogen shall be examined for compliance with the requirements of 5.1 and the marking shall be examined to determine whether any marking is missing, illegible, incorrect, or incomplete. Any one defect shall be cause for rejection. 5. PREPARATION FOR DELIVERY Shipment of the containers of nitrogen shall conform to

5.1 Packing. 49 CFR 171-190.

5.1.1 Palletization. When specified (see nitrogen contained in cylinders shall be pelletized in accordance with MIL-STD-147. 5.2 Marking. The containers shall be marking in accordance with 49 CFR 171-190. Each container shall be stenciled or tagged with the type, grade, and class of nitrogen it contains. 5.2.1 Civil agencies. In addition to the marking specified in 5.2, the containers shall be marked in accordance with FED. STD. No. 123. 5.2.2 Military agencies. In addition to the marking specified in 5.2, the containers shall be marked in accordance with MM-STD-129. 6. NOTES

6.1 Intended use. Gaseous nitrogen is used for pressurizing fuel tanks and hydraulic system accumulators, superpressurizing carbon dioxide and

14

BB-N-411C fluorocarbon cylinders (e.g., fire extinguishers), purging equipment calibrating instruments, and providing insert atmospheres. Oxygen systems may be purged with class 1 nitrogen. The grade A nitrogen in a gaseous state is specifically intended for purging missile systems equipment. Grade A and grade B, class nitrogen are suitable for purging aircraft oxygen converters, pressurize aircraft struts, and purging and pressurizing rocket engine propellant systems. Liquid nitrogen is used as a cooling agent in low temperature processes, as an agent to shield against heat effects on temperature-critical apparatus, and as a source of gaseous nitrogen. 6.2 Ordering data. Purchasers should exercise any desired options offered herein, and procurement documents should specify the following: (a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) Title, number, and date of this specification. Type, grade and class of nitrogen required (see 1.2). When new cylinders are to be furnished to the Government by the gas supplier or when the gaseous nitrogen is to be contained in supplier-owned containers (see 3.2.1). Whether liquid nitrogen is to be delivery in supplier-owned or Government-furnished containers or tank trucks (see 3.2.2). Extent of maintenance required on Government-furnished containers (see 3.3 and 6.6). When hydrostatic testing is required every 10 years in lieu of 5 years, (see 3.3.1.2). When replacement valves for Government-furnished cylinders are not to be furnished by the supplier (see 3.3.3). Quantity of liquid nitrogen required in a container, if loss than rated capacity (see 3.4). When bulk liquid nitrogen way be tested in lieu of sample small liquid containers filled from bulk source (see 4.3.1.3). When total hydrocarbon content test is required (see 4.4.2.5). When cylinders are to be palletized (see 5.1.1).

6.3 Class 1 and class 2 nitrogen. Gaseous nitrogen is considered oil free, if the gas is compressed with a water-lubricated or dry-seal compressor or a cryogenic converter and if the gas is produced from a liquid nitrogen source. Liquid nitrogen is oil free by nature of the production process. Contamination would be caused by contact with contaminated equipment or by improper container handling methods. Cylinders for nitrogen are considered oil free if the cylinder meet the maintenance criteria specified in 3.3, or if the cylinders an internally cleaned to meet the oil-free criteria specified in RR-C-901. The container maintenance and nitrogen production requirements of BB-N-411 insure that both class 1 and class 2 nitrogen are handled identically. The only remaining difference between

15

BB-N-411C classes is the valve-outlet application. Class I nitrogen cylinders utilize either connection 580 or 000, whereas class 2 nitrogen cylinders use connection 590. Connection 590 is obsolete for nitrogen service and is to be phased out of the Government system. Users should replace valves having connections 590 with valves having connection 580 in normal cylinder maintenance. The 000 connection is a non-standard outlet used to service artillery. Users should consider replacing the connection 000 with connection 580. 6.4 Particulate matter control. For some purposes, such as aircraft oxygen converter purging, pressurization of aircraft struts, and purging and pressurization of rocket engine propellant systems, it is important to control the nitrogen particulate matter content as specified in 3.1. Control of particulate matter in the user's dispensing equipment can be assured by the installation of a 10 micron or better nominal filter in the service line. 6.5 Government-furnished containers. The contracting officer should arrange to furnish the cylinders specified in 3.2.1. 6.6 Maintenance of Government-furnished containers. Purchasers should specify the extent to which Government-furnish containers that require maintenance should be processed by the gas supplier. 6.6.1 The gas supplier should furnish at no additional costs all services which are required at each and every filling of a container to comply with applicable regulations and normal practice. Such services would include, but not be limited to, all inspection, testing, evacuation, and handling services required for the gas supplied. 6.6.2 A schedule of allowable fees should be specified by the purchaser for the gas supplier's performance of services such as the replacement of valves, valve parts, and cylinder caps, hydrostatic testing, cleaning, painting, color coding, marking, and handling of unserviceable containers as required. All materials and components for these services should be furnished by the gas supplier. 6.7 Grade comparison. The limiting characteristics of the nitrogen grades specified herein are considered identical to those of grades presented in Compressed Gas Association (CGA) Specification for Nitrogen, G-10.1 as follows: GRADES A B C G D C

BB-N-411 G-10.1 (ed. 1969)

16

BB-N-411 6.8 Basis of purchase.

6.8.1 Type I (gaseous) nitrogen should be purchased by the cubic foot, based upon normal atmospheric conditions. Gaseous nitrogen is available in several cylinder sizes ranging from 180 through 340 cubic feet capacity at the rated service pressure. 6.8.2 Type II (liquid) nitrogen should be purchased by the pound or by the short ton. The following-conversion factors for liquid nitrogen should be used: Pound (mass) Liquid Liquid Cubic feet of gaseous Gallons Liters nitrogen at 70 deg. F. and 1 atmosphere pressure. 1.0000 0.1484 0.5618 13.8000 6.7380 1.0000 3.7850 93.0100 1.7800 0.2642 1.0000 24.5700 0.0724 0.0108 0.0407 1.0000 6.9 International standardization. Certain provisions (see 3.1) of this specification are the subject of international standardization agreement ASCC Air Standard 14/6 and 14/10, and NATO STANAG'S 3443GGS 3546GGS and 3624GGS. When amendment, revision, or cancellation of this specification is proposed which will effect or violate the international agreement concerned, the preparing activity will take appropriate reconciliation action through international standardization channels including departmental standardization offices, if required. MILITARY INTEREST Custodians: Army - ME Navy - SH Air Force - 68 Review activities: Army - MD User activities: Army - GL Navy - YD, AS, NC Preparing activity: Army - ME Orders for this publication are to be placed with General Services Administration, acting as an agent for the Superintendent of Documents. See section 2 of this specification to obtain extra copies and other documents referenced herein. Price 20 cents each. 17 CIVIL AGENCIES MD - GSA - AGR HEW - COM Project No. 683-0059