ABB central inverters raise reliability, efficiency and ease on installation to new levels. The inverters are aimed at system integrators and end users who require high performance solar inverters for large photovoltaic power plants and industrial and commercial buildings. The inverters are available from 100 kW up to 500 kW, and are optimized for cost-efficient multimegawatt power plants. Worlds leading inverter platform The ABB solar inverters have been developed on the basis of decades of experience in the industry and proven technology platform. Unrivalled expertise from the worlds market and technology leader in variable speed AC and DC drives is the hallmark of the new solar inverter series.
Based on ABBs highly successful platform of industrial drives - the most widely used industrial drives on the market the inverters are the most efficient and cost-effective way to convert the direct current generated by solar modules into high-quality and CO 2-free alternating current that can be fed into the power network. Solar inverters from ABB ABB central inverters are ideal for large photovoltaic power plants and medium sized power plants installed in commercial or industrial buildings. High efficiency, proven components, compact and modular design and a host of life cycle services ensures ABB central inverters provide a rapid return on investment.
Highlights High efficiency and long operating life Modular and compact product design Extensive DC and AC side protection Power factor compensation as standard Fast and easy installation Complete range of industrial-type data communication options, including remote monitoring Life cycle service and support through ABBs extensive global service network
eldbus connection and integrated DC cabinets. The inverters are customized and congured to meet end user needs and are available with short delivery times. Effective connectivity ABBs transformerless central inverter series enables system integrators to design the solar power plant using a combination of different power rating inverters, which are connected to the medium voltage grid centrally. In certain conditions, the ABB central inverters topology allows a parallel connection directly to the AC side, enabling electricity to be fed to the grid via a single transformer. This avoids the need for each central inverter to have its own transformer, thereby saving cost and space. However, in systems where the DC side needs to be grounded, an inverter dedicated winding within a transformer, or a separate transformer, must be used always.
PVS800-57-0100kW-A 100 kW 120 kWp 450 to 750 V (- 825 V*) 900 V (1000 V*) 245 A < 3% 1 (+/-) / 4 100 kW 195 A 300 V 50 / 60 Hz < 3% Yes TN and IT 98.0% 97.5% < 350 W < appr. 55 W 230 V, 50 Hz 1030 / 2130 / 644 550 kg
5) 6) 7) 8)
PVS800-57-0250kW-A 250 kW 300 kWp 450 to 750 V (- 825 V*) 900 V (1000 V*) 600 A < 3%
PVS800-57-0500kW-A 500 kW 600 kW p 450 to 750 V (- 825 V*) 900 V (1000 V*) 1145 A < 3%
2)
2)
4 (+/-) / 16 500 kW 965 A 300 V 50 / 60 Hz < 3% Yes TN and IT 98.0% 97.6% < 600 W
2)
50 / 60 Hz < 3% Yes TN and IT 98.0% 97.6% < 300 W < appr. 55 W 230 V, 50 Hz 1830 / 2130 / 644 1100 kg
*
Power consumption Own consumption in operation Standby operation consumption External auxiliary voltage Dimensions and weight Width / Height / Depth, mm (W / H / D) Weight appr.
1) 2) 3) 4)
8)
Inverter limits the power to a safe level Optional MCB inputs, 80 A each Grid voltage (+/- 10%) Grid frequency (48 to 63 Hz)
At nominal power 300 V output must be IT type Without auxiliary power consumption at 450 V UDC 115 V, 60 Hz optional
PVS800 inverter
EMC filter
PVS800 inverter
EMC filter
Type designation Environmental limits Degree of protection Ambient temperature range (nominal ratings) Maximum ambient temperature
11) 10)
Filter
EMC filter
PVS800-57-0250kW-A 250 kW IP22 / IP42 +50 C 15% to 95% 2000 m 75 dBA
13) 9)
EMC filter
Filter
-15 C to +40 C
-15 C to +40 C
-15 C to +40 C
Relative humidity, not condensing Maximum altitude (above sea level) Maximum noise level Cooling air flow Protection Ground fault monitoring Grid monitoring Anti-islanding
9) 9) 9)
2000 m 75 dBA 1300 m 3/h Yes Yes Yes Yes Yes Yes ABB local control panel 1/2 3/1
1880 m3/h Yes Yes Yes Yes Yes Yes ABB local control panel 1/2 3/1 Modbus, PROFIBUS, Ethernet
3760 m3/h Yes Yes Yes Yes Yes Yes ABB local control panel 1/2 3/1
DC reverse polarity AC and DC short circuit and over current AC and DC over voltage and temperature User interface and communications Local user interface Analog inputs / outputs Digital inputs / relay outputs Fieldbus connectivity Product compliance Safety and EMC Certifications and approvals Grid support
9) 10) 11) 12) 13)
CE conformity according to LV and EMC directives VDE, CEI, UNE, RD, EDF Reactive power compensation, Power reduction, Low voltage ride through
9)
Optional Frosting is not allowed. May need optional cabinet heating. Power derating after 40 C Power derating above 1000 m. Above 2000 m special requirements. At partial power typically < 70 dBA Product flyer for PVS800 | ABB solar inverters 3
Adapter module
Internet Remote PC
3-phase 20 kV
250 kWp solar array Central inverter Central inverter 250 kWp solar array
Accessories Solar array junction boxes with string monitoring Remote monitoring solutions Warranty extensions possible Solar inverter care contracts
Options Increased IP ratings for cabinets Integrated DC input extension cabinets AC output grounding switch Cabinet heating I/O extensions Extended voltage range, 1000 VDC max. DC grounding (negative and positive) Fieldbus and Ethernet connections
Support and service ABB supports its customers with a dedicated service network in more than 60 countries and provides a complete range of life cycle services from installation and commissioning to preventative maintenance, spare parts, repairs and recycling.
For more information contact your local ABB representative or visit: www.abb.com/solar www.abb.com