The standard method of showing a contact is by indicating the circuit

condition it produces when the actuating device is in the . state. (A)Energized (B)Deenergized (C)None of the above
2. Switch symbols are also used to indicate an open or closed path of

.. (A)Current flow (B)Voltage flow (C)Pressure flow

3. A normally open momentary pushbutton closes as long as the button is held

.. (A)Up (B)Down (C)Forward

4. A normally closed momentary pushbutton opens as long as the button is held

... (A)Up (B)Down (C)Forward

5. Coil symbol .. frequently indicates a motor starter.

(A)CR (B)M (C)NO

6. Coil symbol.. indicates a control relay.

(A)CR (B)M (C)NO

7. Contactors and Relays use an .. action.

(A)Electric (B)Magnetic (C)electromagnetic

8. Control-circuit wiring is represented by a .. line.

(A)Heavier-weight (B)Lighter-weight (C)Dash

9. Power-circuit wiring is represented by a . line.

(D)

Heavier-weight

(E)Lighter-weight (F) Dash

10. Pressure switches are control devices that respond to changes in .. of

liquid or air.

(A)Voltage (B)Power

(C)pressure

11. means supervisory control and data acquisition.

(A)PLC (B)SCADA (C)fuzzy

12. .is the apparatus which presents process data to a human

operator, and through this, the human operator monitors and controls the process. (A)A supervisory ( computer ) system (B)A human-machine interface (C)Remote terminal unit

13. .., gathering (acquiring) data on the process and sending

commands (control) to the process. (A)A supervisory ( computer ) system (B)A human-machine interface (C)Remote terminal unit

14. . connecting to sensors in the process, converting sensor

signals to digital data and sending digital data to the supervisory system. (A)A supervisory ( computer ) system (B)Remote terminal unit (C)Programmable logic control

15. .. used as field devices because they are more economical,

versatile, flexible, and configurable than special-purpose RTUs. (A)A supervisory ( computer ) system (B)Remote terminal unit (C) Programmable logic control PLC

16. connecting the supervisory system to the Remote

Terminal Units. (A)Communication infrastructure (B)A human-machine interface (C)Remote terminal unit

17.

Switch symbols are also used to indicate an open or closed path of... (A)current flow (B)voltage (C)resistance

18.

Variations of switch symbols are used to represent .. (A)limit switches (B)foot switches (C)pressure switches (D) all of the above

19.

. Switches, like contacts, (A)require another device or action to change their state (B)dont require any other devices to operate (C)operate on their own

20. In the case of a .someone must manually change the position of the switch. (A)Automatic switch. (B)manual switch (C)ATS

21.

There are two basic types of..: momentary and maintained (A)ATS (B)Switch (C)Pushbuttons

22. A normally open momentary pushbutton closes as long as the button is .. (A)held down (B)held up 23. A normally closed momentary pushbutton .as long as the button is held down. (A)Opens (B)Closes 24. A maintained ..latches in place when the button is pressed. (A)ATS (B)Pushbutton (C)Pressure switch 25. are used in electromagnetic starters, contactors, and relays (A)Coils (B)Capacitors (C)Speed control 26. The purpose of contactors and relays is to (A)Protect against lightening (B)open and close associated contacts (C)take signal from contacts 27. ..are used to protect motors from overheating due to an overload on the driven machinery (A)Overvoltage relay (B)Overload relays (C)Pressure switch 28. When excessive current is drawn for a predetermined amount of time, the overload relay .. (A)Opens and the motor is disconnected from its source of power.

(B)Closes and the motor is connected to source of power (C)Closes and motor starts operating 29. A .is a small electric light used to indicate a specific condition of a circuit. (A)Push button (B)Contactor (C)pilot light