You are on page 1of 2

2780 Waterfront Pkwy. E. Dr. Suite 200 Indianapolis, IN 46214 Phone: 317-328-5660 Fax: 317-328-5668 Sales: 1-800-437-3188 www.calumetspecialty.

com

Product Data Sheet


If you have questions regarding this product, please contact your Sales Representative. Customer Service and Technical Service can be reached at 1-800-437-3188.

Product: Revised: HazMat Name: STCC: Test Viscosity, CST @ 0C Viscosity, CST @ 40C Viscosity, CST @ 100C Viscosity, SUS @ 100F Gravity, API, 60F Density @ 15C, KG/DM3 Flash Point, COC, C Flash Point, COC, F Pour Point, C Pour Point, F Color, ASTM Aniline Point, C Aniline Point, F Neut. No., MG KOH/G Water Content, ppm Dielectric Breakdown @ 60 HZ Disk Electrodes, KV KV 1.02 MM Gap KV 2.03 MM Gap Dielec. Brkdwn, Impulse Conds. 25C, Needle Neg. to Sphere Grounded, 25.4 MM Gap, KV Corrosive Sulfur Interfacial Tension, Dynes/CM Oxidation Stability 72 hr Sludge, Mass % 72 hr Acid No., MG KOH/G 164 hr Sludge, Mass % 164 hr Acid No., MG KOH/G Oxidation Stability, RBOT, MIN Oxid.Inhib. Content, Mass% Gassing Tendency Micro L/MIN (Procedure B) Power Factor, 25C, % Power Factor, 100C, % Visual Examination PCB Content, PPM
Printed 1/12/2012 10:35 AM EST

Caltran 60-30 (Type II) 02/10/2010 Non-Regulated 29-114-15 Method D445 D445 D445 D2161 D4052 D4052 D92 D92 D97 D97 D1500 D611 D611 D974 D1533 D877 D1816 D1816 D3300 MIN

Product Code:

3020-00-J

MAX 76.00 12.00 3.00

Typical 62.23 9.23 2.35 58.58 28.5 0.8838 151 304 -56 -69 L0.5 75.8 168.4 0.013 11 42 30 60

0.9100 145 293 -40 -40 0.5 63.0 145.3 0.03 35 30 20 35

D1275 (Method B) D971 D2440

145 n/corros. 40 0.1 0.3 0.2 0.4

300 n/corros. 48.0 0.01 0.01 0.03 0.01 220 0.26 +24 0.001 0.04 B&C <1
Page: 1/2

D2112 D2668 D2300 D924 D924 D1524 D4059

195 0.30 +30 0.05 0.30 B&C 1

2780 Waterfront Pkwy. E. Dr. Suite 200 Indianapolis, IN 46214 Phone: 317-328-5660 Fax: 317-328-5668 Sales: 1-800-437-3188 www.calumetspecialty.com

Product Data Sheet

Copyright 2008 Calumet Specialty Products Partners, L.P. Calumet's sampling and testing procedures in effect at the time of production will be used for certification testing. Results may be based on tank certification, manufacturing data, periodic testing and/or most recent product restock. Typical values only represent the values one would expect if the property were tested in our laboratories with our test methods on the specified date. Some product properties are not frequently measured, and accordingly typical values are not based on a statistically relevant number of tests. The information in this document relates only to the named product. The user is solely responsible for all determination regarding any use and any process.

Printed 1/12/2012 10:35 AM

EST

Page: 2/2

You might also like