LEVEL PRO Settings (Service Menu)

General rules:
·0Change between menus with Set Up/Down keys
·1Change values with Act Up/Down keys
·2Reset values to default by holding Act Up and Act Dn keys (like resetting
set/act values)
·3Enter submenus with S key, leave with A key

To change into the Wirtgen Menu:


·4Change into Settings Menu with S key (sensor menu, S, PoS etc.)
·5Hold Set Up and Down keys pressed until display changes to SEt UP (2
seconds),
·6Press Set Up, Set Down, S keys in the given order => Display "Hy.P MEn"
(Hydraulik Menu).
·7Service Menus: "Hy.P" - hydraulic parameters, "Pot" - Wire Rope, "SLo" - Slope,
"Son" - Sonic, "LAS" - Prop Laser, "3D" - 3D Sensor, "SysV" - system version, "d"
- firmware date, "FwV" - firmware version, "HrS" - working hours, "n.St" -
number of starts, "Save" - save factory settings, "Load" - restore factory
settings

Hydraulik menu ("Hy.P") for proportional valves:


·8Hydraulic currents in A are in the following order: i.up (old symbol n_C)
MinCurrent Up, i.dn (old u_C) MinCurrent Down, I.up (old I_C) MaxCurrent Up,
I.dn (old U_C) MaxCurrent Down (n, u - small arrows, I, U - big arrows)
·9New menu names since ver. 3022: i.up, i.dn, I.up, I.dn
·10 Cylinder Up/Down in Hydraulik Parameter outputs immediately the set
current. Depending on the arrow (small/big) it will be the Min- or
MaxCurrent. Always check the current with Cylinder Up/Down in Hydraulik
Parameter Menu!
·11 "CAL OFF" - automatic min/max current calibration. Experimental, do
not use.
·12 "SPd" - speed menu. Experimental, do not use.
·13 CL.up (old until ver. 3021 "ICL") - current controller up, CL.dn (old "UCL")
- current controller down
·14 "SCAL OFF" - current controller calibration. Setting to ON will calibrate
all 4 current controllers. Recommended!
·15 "rS" - valve resistance in Ohm. Default 12 Ohm.
·16 "tAu" - valve time constant in ms. Default 25 ms.

Hydraulik menu ("Hy.P") for black/white valves:


·17 Hydraulic pulses in ms are in the following order: p.up (old n_P)
MinPulse Up, p.dn (old u_P) MinPulse Down, P.up (old I_P) MaxPulse Up, P.dn
(old U_C) MaxPulse Down (n, u - small arrows, I, U - big arrows)
·18 New menu names since ver. 3022: p.up, p.dn, P.up, P.dn
·19 Cylinder Up/Down in Hydraulik Parameter outputs immediately the
chosen pulse. Depending on the arrow (small/big) it will be the Min- or
MaxPulse. Always check the pulse with Cylinder Up/Down in Hydraulik
Parameter Menu!
·20 "FrE" - pulsing frequency, default 1.8 Hz
·21 "bS.P" - pulse boost, default 250%. At this value of controlled output
(100% corresponds to PropBand) additional boost outputs will be activated
·22 CL.up (old "ICL") - current controller up, CL.dn (old "UCL") - current
controller down - see above. Currently not used in pulse mode.

"Pot" - Settings for Wire Rope (Grade) sensor


·23 Pb.1 - Proportional Band when S=1. Default 0.6 cm
·24 Pb.9 - Proportional Band when S=9. Default 3.5 cm
·25 Db.1 - Dead Band when S=1. Default 0.1 cm
·26 Db.9 - Dead Band when S=9. Default 0.0 cm
·27 FGF - Filter Frequency. Default 15 Hz
·28 OFF - Offset. When sensor connected, raw value without offset is
displayed in "Set", value with offset in "Act"

"SLo" - Settings Slope


·29 Pb.1 - Proportional Band when S=1. Default 2.0%
·30 Pb.9 - Proportional Band when S=9. Default 4.0%
·31 Db.1 - Dead Band when S=1. Default 0.2%
·32 Db.9 - Dead Band when S=9. Default 0.1%
·33 FGF - Filter Frequency. Default 0.9 Hz. You can try to change it up to 8.0
Hz with old mechanical sensor, up to 1.0-1.2 with new fluid sensor
·34 OFF - Offset. When sensor connected, raw value without offset is
displayed in "Set", value with offset in "Act"