You are on page 1of 55

BD-AF

Central Data Bank


List of Building Materials

A. General

Department: Buildings

Type of building material: Structural Fixing

Applications: Drill-in/Cast-in Anchors

B. Acceptance criteria

Testing standards:
Testing of drill-in anchors and cast-in anchors should be in
accordance with BS 5080.

Conditions of Acceptance:
• The factor of safety of structural fixing systems (drill-in anchors
and cast-in anchors) shall not be less than 3.
• Structural fixing systems shall be properly installed and securely
fixed to the parent structure in accordance with the manufacturer’s
specifications/recommendations.
• Suitability of the structural fixing system in terms of fire
performance as well as any need for fire protection of the exposed
parts of the fixing system shall be considered individually.
• Where drill-in anchors are used for cladding works or for
supporting steel cantilevered canopy structures, strength tests on
a representative number of the drill-in anchors may be required.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Fischer Steel fischerwerke Artur Zinc-plated steel, or Drill-in anchors BS 5080: Parts 1 N/A University of Hong A-MIS-487, January 1991 18/01/2005 No-objection letter issued
Anchors Fischer GmbH & stainless steel A4. subject to axial &2 Kong, Department A-MIS-488 in 1991.
001
Co. KG tension and of Civil &
Types EA M8, shear. Structural Updated information on
M12 & M16 (See remarks) Engineering place of manufacture to
be provided by the
manufacturer.

The application of the


anchors is to be
considered individually
with regard to the fire
resistance aspect.
BD-AF
Fischer Steel fischerwerke Artur Zinc-plated steel Drill-in anchors BS 5080: Parts 1 N/A University of Hong A-MIS-487, January 1991 18/01/2005 No-objection letter issued
002 Anchors Fischer GmbH & subject to axial &2 Kong, Department A-MIS-488 in 1991.
Co. KG tension and of Civil &
Types FB 8/50, shear. Structural Updated information on
10/50 & 12/50 (See remarks) Engineering place of manufacture to
be provided by the
manufacturer.

The application of the


anchors is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Hemax 820 Harris & Edgar Grade 303 austenitic Drill-in anchors BS 5080: Part 1: N/A John Laing RD/82/116/ST August 1982 18/01/2005 No-objection letter
003 Parallel Limited stainless steel fixed in concrete 1974 Research and issued in 1993.
Expansion base material Development
Bolts (See remarks) and subject to Limited. Updated information on
axial tension and place of manufacture to
M8, M10, BS 5080: Part 2: Laing Technology be provided by the
shear. NAMAS TS931095 July 1993
M12, M16 & 1986 Group Limited manufacturer.
M20 Details and load
capacities of the Structural applications
anchors are as which may be exposed
shown in to fire will be considered
appendix A to individually.
BD’s letter Ref.
Tests for quality control
BD
and workmanship may
GR/SEG/AF(9)
be required during
of 6 September
construction.
1993.
BD-AF
Hilti HHS Hilti (Hong Kong) Galvanized steel Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter
004 Self-drilling Limited drill-in anchors issued in 1984.
Anchor * Test report could
(See remarks) not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Hilti HKD Hilti (Hong Kong) N/A Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
005 Anchor Limited drill-in anchors in 1984.
* Test report could
(See remarks) not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
BD-AF
Hilti HSA Stud Hilti (Hong Kong) N/A Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
006 Anchor Limited drill-in anchors in 1984.
* Test report could
(See remarks) not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Hilti Hilti Corporation Stainless steel grade Drill-in anchors BS 5080: Parts 1 N/A Hong Kong AN-1 January 1994 18/01/2005 No-objection letter issued
007 HSA –303 303 fixed in concrete &2 University, Civil in 1994.
Stud Anchor (See remarks) base material Engineering AN-2
and subject to Department Updated information on
M8, M10 & axial tension and Testing Laboratory place of manufacture to
M12 shear. be provided by the
manufacturer.
Details and load
capacities of the Structural applications
anchors are as which may be exposed to
shown in fire will be considered
appendices A & individually.
B to BD’s letter
Tests for quality control
Ref. (3) in BD
and workmanship may be
GR/SEG/AF(13)
required during
of 1 March
construction.
1994.

BD-AF Hilti HSC Hilti Galvanized steel Drill-in anchors BS 5080: Parts 1 HOKLAS Hong Kong AN56 May 1992 18/01/2005 No-objection letter issued
Safety Anchor Aktiengesellschaft fixed in concrete &2 University, Civil in 1993.
008 AN57 May 1992
base material Engineering
AM8x40, (See remarks) and subject to Department Updated information on
AM8x50, AN82 June 1993 place of manufacture to
axial tension and Testing Laboratory
AM10x40, shear. be provided by the
AM12x60, manufacturer.
IM8x40, Details and load
IM10x50, capacities of the Structural applications
IM10x60 & anchors are as which may be exposed to
IM12x60 shown in fire will be considered
appendix A to individually.
BD’s letter Ref.
Tests for quality control
(15) in BLD(B)
and workmanship may be
GR/SEG/AF(6)
required during
of 8 July 1993.
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Hilti HSL Hilti (Hong Kong) Grade 8.8 galvanized Heavy duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
009 Heavy Duty Limited steel drill-in anchors in 1984.
Anchor * Test report could
(See remarks) not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.

BD-AF Hilti HSL-TZ Hilti Corporation Zinc galvanized Drill-in anchors BS 5080: Parts 1 N/A University of Hong AN11 October 1991 18/01/2005 No-objection letter issued
Heavy Duty grade 8.8 steel subject to axial &2 Kong, Department in 1992.
010 (See remarks) AN24 December
Anchor tension and of Civil &
shear. Structural 1991 Updated information on
M8, M10, AN25 place of manufacture to
Engineering
M12, M16 & be provided by the
M20 manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Hilti HST-R Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Parts 1 N/A Hong Kong AN85 August 1993 18/01/2005 No-objection letter issued
011 Safety Anchor fixed in &2 University, Civil in 1993.
(See remarks)
uncracked Engineering AN86 September
M8, M10, concrete base Department 1993 Updated information on
M12, M16, material and Testing Laboratory place of manufacture to
M20 & M24 subject to axial be provided by the
tension and manufacturer.
shear.
Structural applications
Details and load which may be exposed to
capacities of the fire will be considered
anchors are as individually.
shown in
Tests for quality control
appendix A to
and workmanship may be
BD’s letter Ref.
required during
(19) in BD
construction.
GR/SEG/AF(6)
of 15 December
1993.

BD-AF Hilti HVA Hilti (Hong Kong) N/A Heavy duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
Adhesive Limited anchors in 1984.
012 * Test report could
Anchor (See remarks)
not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Ramset Ramset Fasteners N/A Heavy duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
013 Chemset (H.K.) Ltd. anchors in 1989.
Chemical * Test report could
(See remarks)
Anchor not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.

BD-AF Ramset Ramset Fasteners N/A Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
Dynabolt (H.K.) Ltd. anchors in 1989.
014 * Test report could
Anchor
(See remarks) not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
BD-AF
Ramset Ramset Fasteners N/A Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
015 Dynaset (H.K.) Ltd. anchors in 1989.
Anchor * Test report could
(See remarks)
not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Ramset Terrier Ramset Fasteners N/A Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
Self-drilling (H.K.) Ltd. anchors in 1989.
016 * Test report could
Anchor
(See remarks) not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
BD-AF
Ramset Ramset Fasteners N/A Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
017 Trubolt Anchor (H.K.) Ltd. anchors in 1989.
* Test report could
(See remarks)
not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Rawlplug Rawlplug Company Zinc plated, or Drill-in chemical BS5080 N/A Swedish National 87B1.1801 1988 18/01/2005 No-objection letter issued
Kemfix Ltd. stainless steel (grade anchors subject equivalent Testing Institute in 1994.
018
Chemical 303) to axial tension
Anchor (See remarks) and shear. Updated information on
place of manufacture to
M8, M10, Load capacities be provided by the
M12, M16, of the anchors manufacturer.
M20 & M24 are as shown in
appendix C to Structural applications
BD’s letter Ref. which may be exposed to
(19) in BD fire will be considered
GR/SEG/AF(10) individually.
.
Tests for quality control
and workmanship may be
required during
construction.
BD-AF
Rawlplug Rawlplug Company Zinc plated steel Drill-in anchors BS 5080 N/A Thornliebank N/A* N/A 18/01/2005 No-objection letter issued
019 Rawlbolt Ltd. subject to axial equivalent in 1994.
tension and * Test report could
(See remarks)
M6, M8, M10, shear. not be retrieved. Updated information on
M12, M16, place of manufacture to
M20 & M24 Load capacities be provided by the
of the anchors manufacturer.
are as shown in
appendix A to Structural applications
BD’s letter Ref. which may be exposed to
(19) in BD fire will be considered
GR/SEG/AF(10) individually.
.
Tests for quality control
and workmanship may be
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Rawlplug Rawlplug Company Zinc plated, or Drill-in anchors BS 5080 N/A Thornliebank N/A* N/A 18/01/2005 No-objection letter issued
Tufbolt Ltd. stainless steel (grade subject to axial equivalent * Test report could in 1993.
020
303 or 316) tension and not be retrieved.
M6, M8, M10, (See remarks) shear. Updated information on
M12, M16 & place of manufacture to
M20 Load capacities be provided by the
of the anchors manufacturer.
are as shown in
appendix A to Structural applications
BD’s letter Ref. which may be exposed to
(14) in BD fire will be considered
GR/SEG/AF(10) individually.
.
Tests for quality control
and workmanship may be
required during
construction.
BD-AF
Spit Fix Signode Hong Kong Stainless steel grade Drill-in anchors Testing methods HOKLAS Hong Kong A-MIS-477 August 1990 18/01/2005 No-objection letter issued
021 Anchor Ltd. 303 subject to axial were given in the University, Civil in 1990.
tension and test reports. Engineering A-MIS-480 August 1990
(See remarks)
M10 & M12 shear. Department Updated information on
A-MIS-478 August 1990 place of manufacture to
Testing Laboratory
be provided by the
A-MIS-481 August 1990
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Spit Fix Signode Hong Kong Grade 5.8 steel. Drill-in anchors Testing methods HOKLAS Hong Kong A-MIS-474 July 1990 18/01/2005 No-objection letter issued
022 Anchor Ltd. subject to axial were given in the University, Civil in 1990.
tension and test reports. Engineering A-MIS-482 August 1990
(See remarks)
M16 shear. Department Updated information on
Testing Laboratory place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Sunway Sunway Metal Stainless steel (SUS Drill-in anchors BS 5080: Part 1: N/A MateriaLab 910064t10008 January 1991 18/01/2005 No-objection letter issued
Anchor Bolt Manufactory 304) subject to axial 1974 Limited 901714t4858 in 1992.
023 August 1990
tension and
Model (See remarks) shear. Updated information on
SW-M-10 place of manufacture to
Engineering PD/2257/89
be provided by the
Materials Research January 1989
manufacturer.
& Laboratories
Ltd. Structural applications
BS 5080: Part 2:
July 1991 which may be exposed to
1986 SL0972 fire will be considered
individually.
OPP Testing
Services Ltd. Quality control
procedures for
manufacturing of the
anchors should be in
accordance with the
Sunway’s Quality Control
Procedures (Revision A)
and the subsequent
amendment to the
sampling rate of the
pull-out and shear tests s,
submitted to BD on
28.8.92 and 22.10.92
respectively.

Tests for quality control


and workmanship may be
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Upat EXA Upat GmbH & Co. Stainless steel grade Drill-in anchors BS 5080: Parts 1 N/A University of Hong A-MIS-484 September 18/01/2005 No-objection letters
Express 303 for M6 subject to axial & 2, or otherwise Kong, Department A-MIS-485 1990 issued in 1990 and 1991.
024 (See remarks)
Anchor tension and as stated in the of Civil and
Stainless steel grade shear. test reports. Structural July 1991 Updated information on
AN5
M6 & M12 A1 for M12 Engineering place of manufacture to
AN6
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
BD-AF
Upat EXA Upat GmbH & Co. Stainless steel grade Drill-in anchors BS 5080: Parts 1 HOKLAS Hong Kong AN64 September 18/01/2005 No-objection letter issued
025 Express A1-70 subject to axial &2 University, Civil 1992 in 1992.
(See remarks)
Anchor tension and Engineering AN65
shear. Department Updated information on
M8 & M10 Testing Laboratory place of manufacture to
Details and load be provided by the
AN62
capacities of the manufacturer.
August 1992
anchors are as AN63
shown in Structural applications
appendix A to which may be exposed to
BD’s letter Ref. fire will be considered
(31) in BLD(B) individually.
GR/SEG/AF(4).
Tests for quality control
and workmanship may be
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Upat EXA Upat GmbH & Co. Zinc-plated steel, or Drill-in anchors BS 5080: Parts 1 N/A University of Hong AN5 July 1991 18/01/2005 No-objection letters
Express hot-dipped subject to axial &2 Kong, Department AN6 issued in 1991, 1992 and
026 (See remarks)
Anchor galvanized steel. tension and of Civil and 1993.
shear. Structural AN20
M6, M8, M10, November Updated information on
Engineering AN22
M12, M16 & 1991 place of manufacture to
M20 be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
BD-AF
Upat PSE Upat GmbH & Co. Zinc-plated steel Heavy duty BS 5080: Parts 1 N/A University of Hong AN5 July 1991 18/01/2005 No-objection letter issued
027 14/25 Anchor drill-in anchors &2 Kong, Department in 1991.
(See remarks)
subject to axial of Civil and AN6
M10 tension and Structural Updated information on
shear. Engineering place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
BD-AF
Upat PSE Upat GmbH & Co. Zinc-plated steel Heavy duty BS 5080: Parts 1 N/A University of Hong AN21 November 18/01/2005 No-objection letter issued
028 18/25 Anchor drill-in anchors &2 Kong, Department 1991 in 1992.
(See remarks)
subject to axial of Civil and AN23
M12 tension and Structural Updated information on
shear. Engineering place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Upat PSE Upat GmbH & Co. Zinc-plated grade Heavy duty BS 5080: Parts 1 HOKLAS Hong Kong AN55 April 1992 18/01/2005 No-objection letter issued
24/25 Anchor 8.8 steel drill-in anchors &2 University, Civil AN53 in 1992.
029 (See remarks) subject to axial Engineering
M16 tension and Department Updated information on
shear. Testing Laboratory place of manufacture to
be provided by the
manufacturer.

Structural applications
which may be exposed to
fire will be considered
individually.

Tests for quality control


and workmanship may be
required during
construction.
BD-AF
Upat PSE Upat GmbH & Co. Zinc-plated grade Heavy duty BS 5080: Parts 1 HOKLAS Hong Kong AN55 April 1992 18/01/2005 No-objection letter issued
030 28/25 Anchor 8.8 steel drill-in anchors &2 University, Civil in 1992.
(See remarks)
subject to axial Engineering AN53
M20 tension and Department Updated information on
shear. Testing Laboratory place of manufacture to
be provided by the
manufacturer.

Structural applications
which may be exposed to
fire will be considered
individually.

Tests for quality control


and workmanship may be
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Upat UKA-3 Upat GmbH & Co. Chemical anchor Chemical anchor BS 5080: Parts 1 N/A University of Hong A-MIS-486 September 18/01/2005 No-objection letters
EAP Chemical consists of a with anchorage & 2, or otherwise Kong, Department A-MIS-487 1990 issued in 1990 and 1991.
031 (See remarks)
Anchor stainless steel (grade to be achieved as stated in the of Civil and
316) threaded stud by the bond test reports. Structural Updated information on
M8, M10, with nut and washer formed by the Engineering place of manufacture to
AN5
M12 & M16 and a glass capsule cured chemical be provided by the
AN6
containing quartz mortar between manufacturer.
July 1991
aggregate, epoxy the stud and the
The application is to be
acrylate resin and a surrounding
considered individually
small glass capsule concrete.
with regard to the fire
containing the
resistance aspect.
hardener.
BD-AF
Upat UKA-3 Upat GmbH & Co. Chemical anchor Chemical anchor BS 5080: Parts 1 HOKLAS Hong Kong AN54 April 1992 18/01/2005 No-objection letter issued
032 EAP Chemical consists of a with anchorage &2 University, Civil in 1992.
(See remarks)
Anchor zinc-plated steel to be achieved Engineering AN52
(grade 5.8) threaded by the bond Department Updated information on
M20 & M24 stud with nut and formed by the Testing Laboratory place of manufacture to
washer and a glass cured chemical be provided by the
capsule containing mortar between manufacturer.
quartz aggregate, the stud and the
Structural applications
epoxy acrylate resin surrounding
which may be exposed to
and a small glass concrete.
fire will be considered
capsule containing
individually.
the hardener.
Tests for quality control
and workmanship may be
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Upat USA Upat GmbH & Co. Stainless steel grade Drill-in anchors BS 5080: Parts 1 HOKLAS Hong Kong AN59 May 1992 18/01/2005 No-objection letter issued
Wedge Anchor A4 subject to axial &2 University, Civil AN60 in 1992.
033 (See remarks) tension and Engineering
M8, M10 & shear. Department Updated information on
M12 Testing Laboratory place of manufacture to
be provided by the
manufacturer.

Structural applications
which may be exposed to
fire will be considered
individually.

Tests for quality control


and workmanship may be
required during
construction.
BD-AF
HIT-C100 Hilti (Hong Kong) Modified epoxy Injection system N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
034 Injection Ltd. acrylate resin for grouting of in 1990.
System for adhesive deformed * Test report could
(See remarks)
Deformed reinforcement. not be retrieved. Updated information on
Reinforcement place of manufacture to
be provided by the
manufacturer.

The application of this


rebar system is to be
considered individually
with regard to the fire
resistance.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HIT- Hilti Corporation Two-component Anchorage of BS 5080: Part 1: N/A Hong Kong MI-960181 June 1996 18/01/2005 No-objection letter issued
Rebar adhesive based on Y10 & Y16 1993 University, Civil MI-960182 in 1996.
035 (See remarks)
Fastenings resin and deformed Engineering
cementitious agents. reinforcement as Department Updated information on
structural fixing Testing Laboratory place of manufacture to
in concrete base be provided by the
material for Hong Kong manufacturer.
BS 5080: Part 2: MI-960178
internal building N/A University, Civil June 1996
1986 MI-960177 Structural applications
works only. Engineering
Department which may be exposed to
Setting details, Testing Laboratory fire will be considered
recommended individually.
load capacities
Tests for quality control
and the user
and workmanship may be
guide are as
required during
shown in
construction.
appendices A &
B to BD’s letter
Ref. (17) in BD
GR/SEG/ADH(1
)
BD-AF
Ramset Ramset Fasteners N/A Chemical N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
036 Chemset (H.K.) Ltd. injection system in 1989.
Injection for heavy duty * Test report could
(See remarks)
System anchor fixing. not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
N/A*
BD-AF Red Head Signode Hong Kong N/A Chemical N/A N/A N/A N/A 18/01/2005 No-objection letter issued
* Test report could
Epcon Ltd. injection system in 1990.
037 not be retrieved.
Ceramic 6 for anchor
Injection (See remarks) fixing. Updated information on
System place of manufacture to
be provided by the
M16 & M20 manufacturer.

This anchor system is not


to be used for fire
resisting construction.
BD-AF
Halfen HTA Halfeneisen GmbH Channel: hot-dip Cast-in channels BS 5080: Part 1: HOKLAS Testconsult Far S/017/90/1 January 1991 18/01/2005 No-objection letter issued
038 Cast-in & Co. galvanized mild steel used as structural 1974, or East Ltd. in 1992.
Channel (See remarks) grade St 37-2, or fixings in otherwise as
stainless steel grade building works. stated in the test Updated information on
Type HTA A4 reports. place of manufacture to
52/34 Details and load Wiss, Janney, be provided by the
N/A Elstner Associates, WJE No. 880203 November
(52x34x5.2kg./ Bolt: grade 4.6 steel capacities of the manufacturer.
Inc. 1988
m [, with M10, cast-in channels
M12, M16 or are as shown in Structural applications
M20 bolts) appendix A to which may be exposed to
BD’s letter Ref. fire will be considered
(9) in BLD(B) individually.
GR/SEG/5/8(III).
Tests for quality control
and workmanship may be
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Halfen HTA Halfeneisen GmbH Channel: hot-dip Cast-in channels BS 5080: Part 1: HOKLAS Department of N/A April 1993 18/01/2005 No-objection letter issued
Cast-in & Co. galvanized mild steel used as structural 1974 Civil & Structural in 1994.
039
Channel grade St 37-2 fixings in Engineering, Hong
(See remarks) building works. Kong Polytechnic Updated information on
Type HTA Bolt: grade 4.6 steel, place of manufacture to
50/30 or stainless steel Details and load be provided by the
(50x30x3.4kg./ grade A4 capacities of the manufacturer.
BS 5080: Part 2: Department of N/A
m [, with M10, cast-in channels HOKLAS January 1994
1986 Civil & Structural Structural applications
M12, M16 or are as shown in
M20 bolts) appendix A to Engineering, Hong which may be exposed to
BD’s letter Ref. Kong Polytechnic fire will be considered
BD individually.
GR/SEG/5/8(III)
Tests for quality control
of 13 April 1994.
and workmanship may be
required during
construction.
BD-AF
Halfen HTA Halfeneisen GmbH Channel: hot-dip Cast-in channels BS 5080: Part 1: HOKLAS Testconsult Far S/017/90/1 January 1991 18/01/2005 No-objection letter issued
040 Cast-in & Co. galvanized mild steel used as structural 1974, or East Ltd. in 1992.
Channel (See remarks) grade St 37-2 fixings in otherwise as
building works. stated in the test Updated information on
Type HTA Bolt: grade 4.6 steel, reports. place of manufacture to
40/22 or stainless steel Details and load Wiss, Janney, be provided by the
N/A Elstner Associates, WJE No. 880203 November
(40x22x2.2kg/ grade A4 capacities of the manufacturer.
Inc. 1988
m[, with M10, cast-in channels
M12 or M16 are as shown in Structural applications
bolts) appendix A to which may be exposed to
BD’s letter Ref. fire will be considered
(9) in BLD (B) individually.
GR/SEG/5/8(III)
Tests for quality control
of 18 November
and workmanship may be
1992.
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Halfen HTA Halfeneisen GmbH Channel: hot-dip Cast-in channels BS 5080: Part 1: HOKLAS Department of N/A April 1993 18/01/2005 No-objection letter issued
Cast-in & Co. galvanized mild steel used as structural 1974, or Civil & Structural in 1993.
041
Channel grade St 37-2, fixings in otherwise as Engineering, Hong
(See remarks) stainless steel grades building works. stated in the test Kong Polytechnic Updated information on
Type HTA A2 or A4 reports. place of manufacture to
38/17 Details and load be provided by the
(38x17x1.8kg/ Bolt: grade 4.6 steel, capacities of the manufacturer.
m[, with M10, stainless steel grades cast-in channels Wiss, Janney,
N/A WJE No. 880203 November
M12 or M16 A2 or A4 are as shown in Elstner Associates, Structural applications
1988
bolts) appendix A to Inc. which may be exposed to
BD’s letter Ref. fire will be considered
(23) in BD individually.
GR/SEG/5/8(III)
Tests for quality control
of September
and workmanship may be
1993.
required during
construction.
BD-AF
Jordahl Anchor Jordahl Deutsche Channel: mild steel Anchor channels BS 5080: Part 1, HOKLAS Hong Kong AN62 June 1992 18/01/2005 No-objection letter issued
042 Channel Kahneisen grade St37-2 used as structural or otherwise as University, Civil in 1992.
Gesellschaft West fixings in stated in the test Engineering
Type JTA W GmbH. Bolt: grade 4.6 steel building works. reports. Department Updated information on
54/40/4.0 or stainless steel Testing Laboratory place of manufacture to
(See remarks)
(54x40x5.19kg grade A4 Details and load be provided by the
/m[, with Type capacities of the manufacturer.
B bolts of anchor channels
M10, M12, are as shown in Structural applications
M16 or M20]. appendix A to N/A 2..2/195414 March 1980 which may be exposed to
Institute for fire will be considered
BD’s letter Ref.
Material Testing individually.
(11) in BLD(B)
(BAM)
GR/SEG/AF(8)
Tests for quality control
of 9 November
and workmanship may be
1992.
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Jordahl Anchor Jordahl Deutsche Channel: mild steel Anchor channels BS 5080: Part 1, HOKLAS Hong Kong AN62 June 1992 18/01/2005 No-objection letter issued
Channel Kahneisen grade St37-2 used as structural or otherwise as University, Civil in 1992.
043
Gesellschaft West fixings in stated in the test Engineering
Type JTA W GmbH. Bolt: grade 4.6 steel building works. reports. Department Updated information on
50/30/3.0 or stainless steel Testing Laboratory place of manufacture to
(50x30x3.2kg/ (See remarks) grade A4 Details and load be provided by the
m[, with Type capacities of the manufacturer.
B bolts of anchor channels
M10, M12, are as shown in Structural applications
M16 or M20]. appendix A to 2..2/191531 which may be exposed to
N/A January 1979
Institute for fire will be considered
BD’s letter Ref.
Material Testing individually.
(11) in BLD(B)
(BAM)
GR/SEG/AF(8)
Tests for quality control
of 9 November
and workmanship may be
1992.
required during
construction.
BD-AF
Jordahl Anchor Jordahl Deutsche Channel: mild steel Anchor channels BS 5080: Part 1, HOKLAS Hong Kong AN62 June 1992 18/01/2005 No-objection letter issued
044 Channel Kahneisen grade St37-2 used as structural or otherwise as University, Civil in 1992.
Gesellschaft West fixings in stated in the test Engineering
Type JTA W GmbH. Bolt: grade 4.6 steel building works. reports. Department Updated information on
40/22/2.5 or stainless steel Testing Laboratory place of manufacture to
(See remarks)
(40x22x2.04kg grade A4 Details and load be provided by the
/m[, with Type capacities of the manufacturer.
C bolts of anchor channels
M10, M12 or are as shown in Structural applications
M16] appendix A to N/A 2..2/191531 January 1979 which may be exposed to
Institute for fire will be considered
BD’s letter Ref.
Material Testing individually.
(11) in BLD(B)
(BAM)
GR/SEG/AF(8)
Tests for quality control
of 9 November
and workmanship may be
1992.
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Jordahl Anchor Jordahl Deutsche Channel: mild steel Anchor channels BS 5080: Part 1, HOKLAS Hong Kong AN62 June 1992 18/01/2005 No-objection letter issued
Channel Kahneisen grade St37-2 or used as structural or otherwise as University, Civil in 1992.
045
Gesellschaft West stainless steel grade fixings in stated in the test Engineering
Type JTA K GmbH. A4 building works. reports. Department Updated information on
38/17/3.0 Testing Laboratory place of manufacture to
(38x17x1.78kg (See remarks) Bolt: grade 4.6 steel Details and load be provided by the
/m[, with Type or stainless steel capacities of the manufacturer.
H bolts of grade A4 anchor channels
M10, M12 or are as shown in Structural applications
M16]. appendix A to 2..2/191531 which may be exposed to
N/A January 1979
Institute for fire will be considered
BD’s letter Ref.
Material Testing individually.
(11) in BLD(B)
(BAM)
GR/SEG/AF(8)
Tests for quality control
of 9 November
and workmanship may be
1992.
required during
construction.
BD-AF
Jordahl Anchor Jordahl Deutsche Channel: mild steel Anchor channels BS 5080: Part 1, HOKLAS Hong Kong AN51 March 1992 18/01/2005 No-objection letter issued
046 Channel Kahneisen grade St37-2, used as structural or otherwise as University, Civil in 1992.
Gesellschaft West stainless steel grades fixings in stated in the test Engineering
Type JSA K GmbH. A4 or A2 building works. reports. Department Updated information on
28/15/2.3 Testing Laboratory place of manufacture to
(See remarks)
(28x15x1.11kg Bolt: grade 4.6 steel Details and load be provided by the
/m[, with Type or stainless steel capacities of the manufacturer.
D bolts of M6, grade A4 anchor channels
M8 or M10] are as shown in Structural applications
appendix A to N/A 2..2/191531 January 1979 which may be exposed to
Institute for fire will be considered
BD’s letter Ref.
Material Testing individually.
(11) in BLD(B)
(BAM)
GR/SEG/AF(8)
Tests for quality control
of 9 November
and workmanship may be
1992.
required during
construction.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF TRW Nelson TRW Nelson Stud Bars of diameters of Deformed Steel bars were N/A MateriaLab 901865m10099 February 1991 18/01/2005 No-objection letter issued
Deformed Welding Division, 16mm and 19mm anchor stud bars subjected to Limited in 1991.
047
Anchor Stud Control & Fasteners conforming to used as concrete tensile and bend
Bar Group ASTM-A-496. connectors in tests in Updated information on
building works. accordance with place of manufacture to
Type D2L (See remarks) BS 4449: 1978. be provided by the
manufacturer.
Tensile and shear
tests were also The application of the
conducted on anchors is to be
stud welded considered individually
samples. with regard to the fire
resistance aspect.

Quality control tests on


sufficient samples of
completed stud
connections may be
required to be conducted
at a HOKLAS accredited
laboratory.
BD-AF
Ramset Ramset Fasteners N/A Medium duty N/A N/A N/A N/A* N/A 18/01/2005 No-objection letter issued
048 Concrete Insert (H.K.) Ltd. anchors in 1989.
* Test report could
(See remarks)
not be retrieved. Updated information on
place of manufacture to
be provided by the
manufacturer.

The application is to be
considered individually
with regard to the fire
resistance aspect.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HSL-3 Hilti Corporation Galvanized grade 8.8 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 023097ST22409 2 January 2003 28/04/2005 The application is to be
Heavy Duty steel subject to axial 1993 Services Limited considered individually
049 Nuziders, Austria 023097ST22411 2 January 2003
Anchor tension and with regard to the fire
shear. resistance aspect.
M12 & M20
BS 5080: Part 2:
1986 023097ST22409( 2 January 2003
1)
2 January 2003
023097ST22411(
1)

BD-AF Hilti HSC-A Hilti Corporation Galvanized grade 8.8 Drill-in anchors BS 5080: Parts 1 N/A Hong Kong AN56 May 1992 28/04/2005 The application is to be
050 Safety Anchor Zhangjiang, China steel subject to axial &2 University, Civil considered individually
tension and Engineering AN57 May 1992 with regard to the fire
M10x40 shear. Department resistance aspect.
AN82 June 1993
Testing Laboratory

BD-AF Fischer FAZ Fischerwerke Artur Stainless steel A4 Drill-in anchors BS 5080: Part 1 HOKLAS Hong Kong SF-0052R7283 5 February 28/04/2005 The application is to be
051 16/25/146 Fischer GmbH & Co subject to axial Curtain Wall 2005 considered individually
Anchor Bolt KG tension and Testing Centre Ltd. with regard to the fire
Waldachtal, shear. resistance aspect.
M16 In house method N/A
Germany based on BS 5 February
5080: Part 2: SF-T0088R7283 2005
1986
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Anchors for BS 5080: Part 1: N/A Fugro Technical 042835ST41894A 2 November 28/04/2005 The application is to be
500 injection for chemical installation of 1993. Services Limited 2004 considered individually
052 Kaufering, Germany fastening with grade
adhesive with rubber fenders.. with regard to the fire
anchor rod SUS316 anchor rod. BS 5080: Part 2: 2 November resistance aspect, if
1986 042835ST41895A 2004 applicable.
M42

BD-AF Hilti HIT-HY Hilti Corporation Hybrid resin system Anchors for BS 5080: Part 1 N/A Hong Kong AN-44 15 March 28/04/2005 The application is to be
053 150 injection Kaufering, Germany for fixing of fixing of outdoor University, Civil 1995 considered individually
adhesive with galvanized Grade ancillary Engineering with regard to the fire
Grade 460 460 rebar anchor. amenities. Department resistance aspect, if
rebar of Testing Laboratory applicable.
diameter of
16mm

BD-AF Hilti HIT-HY Hilti Corporation Hybrid resin system Anchors for In house method N/A Hong Kong H06099M1487 17 November 28/04/2005 The application is to be
054 150 injection Kaufering, Germany for fixing of fixing of outdoor based on BS Testing Co., Ltd. 1999 considered individually
adhesive with galvanized Grade ancillary 5080: Part 1 with regard to the fire
Grade 460 460 rebar anchor amenities. resistance aspect, if
rebar of applicable.
diameter of
32mm

BD-AF Hilti HDA-T Hilti Corporation Galvanized grade 8.8 Anchors for BS 5080: Part 2: N/A MateriaLab 000324ST00430( 19 April 2000 03/08/2005 The application is to be
055 self-undercut Liechtenstein steel shear 1986 Limited 1) considered individually
anchor connections with regard to the fire
000324ST00430( resistance aspect.
M10, M12, 3) 19 April 2000
M16 & M20
000324ST00430( 19 April 2000
5)
In-house method Fugro Technical 040547ST40553A
Services Limited 31 March
2004
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HSL-3 Hilti Corporation Galvanized grade 8.8 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 023097ST22410 2 January 2003 03/08/2005 The application is to be
Heavy Duty steel subject to axial 1993. Services Limited considered individually
056 Nuziders, Austria
Anchor tension and with regard to the fire
shear. BS 5080: Part 2: resistance aspect.
M16 1986 023097ST22410( 2 January 2003
1)

BD-AF Hilti HSL-3 Hilti Corporation Galvanized grade 8.8 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 023097ST22408 2 January 2003 03/08/2005 The application is to be
057 Heavy Duty Nuziders, Austria steel subject to axial 1993 Services Limited considered individually
Anchor tension and with regard to the fire
shear. BS 5080: Part 2: resistance aspect.
M10 1986 023097ST22408( 2 January 2003
1)
Ramset Fasteners
BD-AF Ramset Grade 316 stainless Heavy duty BS 5080: Part 1: N/A A.E.S. Destructive GS03-0733 AMD Test date is 03/08/2005 The application is to be
(Aust) Pty Limited
058 Trubolt stud steel torque setting 1993 & Non-destructive No. 1 available but considered individually
anchor expansion Testing Ltd. not the report with regard to the fire
Melbourne, BS 5080: Part 2:
T08090SS anchor subject to date resistance aspect.
Australia 1986
axial tension and
M8x90 shear.

BD-AF Hilti HSL-GR Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Part : N/A ETS-Testconsult FDA50383 26 May 2005 03/08/2005 The application is to be
059 Heavy Duty Nuziders, Austria subject to axial 1993 Limited considered individually
Anchor tension and shear with regard to the fire
BS 5080: Part 2: resistance aspect.
M12/25 1986 FDA50429 8 June 2005
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Fischer FZA Fischerwerke Artur Stainless steel A4 Drill-in anchors In house method HOKLAS Castco Testing BD/MISCEL 29 April 2004 26/10/2005 The application is to be
18x100 M12 Fischer GmbH & Co subject to axial based on HKHA Centre Ltd. 240427-1 considered individually
060
D/20 A4 KG tension and MTS with regard to the fire
Anchor Bolt shear. (2000/2002) resistance aspect.
Waldachtal, Specification
M12 Germany and BS 5080:
Part 1: 1993 BD/MISCEL
240910-1
In house method Castco Testing
based on BS N/A Centre Ltd. BD/MISCEL
5080: Part 2: 240910-2
1986
BD/MISCEL
13 September
240910-3
2004
BD/MISCEL
240910-4

BD/MISCEL
240910-5

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Anchors for BS 5080: Part 1: N/A Fugro Technical 020323ST20500 Report 26/10/2005 The application is to be
061 500 injection for fixing of installation of 1993 Services Limited certified on 13 considered individually
adhesive with Kaufering, Germany galvanized Grade balustrade (not June 2002. with regard to the fire
Grade 460 460 rebar anchor. for fire resisting resistance aspect, if
rebar of construction) applicable.
diameter of
12mm

BD-AF Fischer EA M6 Fischerwerke Artur Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A Hong Kong I001503M00354 7 March 2003 26/10/2005 The application is to be
062 A4 Anchor Fischer GmbH & Co subject to axial 1993 Testing Co., Ltd. considered individually
Bolt KG tension and with regard to the fire
shear. In house method Castco Testing resistance aspect.
M6 Ningbo, China based on BS Centre Ltd. BD/MISCEL 14 July 2005
5080: Part 2: 250712-9
1986
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Jordahl Anchor Deutsche Kahneisen Channel: hot-dip Anchor channels BS 5080: Part 1: UKAS CERAM Building SW032.02 21 March 26/10/2005 The application is to be
Channel Gesellschaft mbH galvanized mild steel used as structural 1993 Technology 2002 considered individually
063
grade St 37-2 fixings in with regard to the fire
Type JTA W Berlin, Germany building works. National Centre resistance aspect.
53/34 with Bolt: grade 4.6 steel CNAL for Quality BETC-CL1-2005-
Type B bolts of Supervision and 54 23 March Shear load capacity shall
M16 or M20 Test of Building 2005 be limited to not
Engineering exceeding the tensile load
capacity.

BD-AF Hilti HSL-3 Hilti Corporation Galvanized grade 8.8 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 023097ST22412 2 January 2003 26/10/2005 The application is to be
064 Heavy Duty steel subject to axial 1993. Services Limited considered individually
Anchor Nuziders, Austria tension and with regard to the fire
shear. BS 5080: Part 2: resistance aspect.
M24 1986 023097ST22412( 2 January 2003
1)

BD-AF Hilti HSL-3 Hilti Corporation Galvanized grade 8.8 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 023097ST22407 2 January 2003 26/10/2005 The application is to be
065 Heavy Duty steel subject to axial 1993. Services Limited considered individually
Anchor Nuziders, Austria tension and with regard to the fire
shear. BS 5080: Part 2: resistance aspect.
M8 1986 023097ST22407( 2 January 2003
1)

BD-AF Hilti HDA-TR Hilti Corporation A4-80 stainless steel Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50469 9 June 2005 03/02/2006 The application is to be
066 self-undercut subject to axial 1993 Limited considered individually
anchor Liechtenstein tension and with regard to the fire
shear. BS 5080: Part 2: resistance aspect.
M16x190/40 1986 FDA50399 30 May 2005

BD-AF Ramset Ramset Fasteners Zinc-plated steel of Steel threaded BS 5080: Part 1: N/A ETS-Testconsult FDA51110 24 November 03/02/2006 The application is to be
067 ChemSet (Aust) Pty Limited grade 5.8 studs grouted 1993 Limited 2005 considered individually
CS12160 Stud with chemical with regard to the fire
Anchor Melbourne, Australia injection mortar. BS 5080: Part 2: 24 November resistance aspect.
1986 FDA51111 2005
grouted in
EPCON G5

M12x80mm
embedment
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HSA-R Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50772 6 September 03/02/2006 The application is to be
stud anchor subject to axial 1993 Limited 2005 considered individually
068 Liechtenstein tension and with regard to the fire
M10 shear. BS 5080: Part 2: 30 August resistance aspect.
1986 FDA50730 2005

BD-AF MKT Wedge Metall-Kunststoff- Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 993114ST10286( 31 March 21/04/2006 The application is to be
069 Anchor subject to axial 1993 Services Limited 4) 2001 considered individually
B8-10/75 Technik GmbH & tension and with regard to the fire
Co. KG shear. BS 5080: Part 2: 993114ST10286( 31 March resistance aspect.
Weilerbach, 1986 5) 2001
Germany
BD-AF Hilti HIT-HY Hilti Corporation Hybrid resin system Injection system BS 476: Part 20: UKAS Warrington Fire WFRC No. 25 September 21/07/2006 The assessment report no.
070 150 Kaufering, Germany for making 1987 Research Centre C121086 2002 WFRC No. C121086 is
nominal valid until 1 October
anchorage 2007.
connections of
Grade 460 rebars Load carrying capacity of
of diameters up the injection system for
to 25mm in rebar fixing under the
reinforced effects of fire should be
concrete assessed with an
elements up to 4 appropriate factor of
hrs. FRP. safety compatible with the
structural design of the
parent structure.

Reference can also be


made to ref. BD-FP 054
under the .
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection system BS 476: Part 20: UKAS Warrington Fire WFRC No. 25 September 21/07/2006 The assessment report no.
500 for making 1987 Research Centre C121086 2002 WFRC No. C121086 is
071 Kaufering, Germany nominal valid until 1 October
anchorage 2007.
connections of
Grade 460 rebars Load carrying capacity of
of diameters up the injection system for
to 40mm in rebar fixing under the
reinforced effects of fire should be
concrete assessed with an
elements up to 4 appropriate factor of
hrs. FRP. safety compatible with the
structural design of the
parent structure.

Reference can also be


made to ref. BD-FP 055 –
Fire Protection Material
for Structural Use.

BD-AF Macsim Macsim Fastenings Grade 316 stainless Drill-in anchors BS 5080: Part 1: N/A Hong Kong M019206M02093 22 May 2006 20/10/2006 The application is to be
Wedge Anchor Pty Ltd. steel subject to axial 1993 Testing Co., Ltd. considered individually
072 M019206M02597 27 June 2006
38S10100 Australia tension and with regard to the fire
shear. BS 5080: Part 2: resistance aspect.
M10 1986

BD-AF Ramset TRIGA SPIT Zinc plated grade 8.8 Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50179 3 March 2005 20/10/2006 The application is to be
Z Heavy Duty France steel subject to axial 1993 Limited considered individually
073 FDA50180 3 March 2005
Anchor tension and with regard to the fire
V12-18/25 shear. BS 5080: Part 2: resistance aspect.
1986
M12
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Ramset TRIGA SPIT Zinc plated grade 8.8 Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50313 23 April 2005 20/10/2006 The application is to be
Z Heavy Duty steel subject to axial 1993 Limited considered individually
074 France FDA50569 21 July 2005
Anchor tension and with regard to the fire
V16-24/25 shear. BS 5080: Part 2: resistance aspect.
1986
M16

BD-AF MKT Wedge Metall-Kunststoff- Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 012720ST21677 17 September 20/10/2006 The application is to be
Anchor B6 subject to axial 1993 Services Limited 2002 considered individually
075 Technik GmbH &
(setting depth tension and with regard to the fire
/embedded Co. KG shear. BS 5080: Part 2: resistance aspect.
1986 012720ST21677(
length: 50mm)
Weilerbach, 1) 17 September
Anchor Germany 2002
diameter: 6mm

BD-AF Hilti HDA-TR Hilti Corporation A4-80 stainless steel Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50476A 28 October 22/01/2007 The application is to be
self-undercut subject to axial 1993 Limited 2005 considered individually
076 Liechtenstein
anchor tension and with regard to the fire
shear. BS 5080: Part 2: 30 May 2005 resistance aspect.
M12x125/30 1986 FDA50397

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection BS 5080: Part 1: N/A ETS-Testconsult FDA61247 6 September 22/01/2007 The application is to be
500 injection for chemical adhesive anchor 1993 Limited 2006 considered individually
077 Kaufering, Germany fastening with grade
adhesive with subject to axial with regard to the fire
HAS ER M20 A4 stainless steel tension and BS 5080: Part 2: 6 September resistance aspect.
1986 FDA61253 2006
rods rod. shear.

BD-AF Hilti HIT-HY Hilti Corporation Hybrid resin system Injection BS 5080: Part 1: N/A ETS-Testconsult FDA61313 15 September 22/01/2007 The application is to be
150 injection for fixing grade 5.8 adhesive anchor 1993 Limited 2006 considered individually
078 Kaufering, Germany galvanized steel rod.
adhesive with subject to axial with regard to the fire
HAS-E M20 tension and BS 5080: Part 2: 15 September resistance aspect.
1986 FDA61318 2006
rods. shear.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HSL-GR Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50435 8 June 2005 22/01/2007 The application is to be
Heavy Duty subject to axial 1993 Limited considered individually
079 Nuziders, Austria
Anchor tension and with regard to the fire
shear. BS 5080: Part 2: resistance aspect.
M16/25 1986 FDA50431 8 June 2005

BD-AF Hilti HSA-R Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50774 6 September 22/01/2007 The application is to be
stud anchor subject to axial 1993. Limited 2005 considered individually
080 Liechtenstein tension and shear with regard to the fire
M12 BS 5080: Part 2: 30 August resistance aspect.
1986 FDA50732 2005

BD-AF Hilti HSA-R Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A ETS-Testconsult FDA50780 6 September 22/01/2007 The application is to be
stud anchor subject to axial 1993. Limited 2005 considered individually
081 Liechtenstein tension and with regard to the fire
M16 shear. BS 5080: Part 2: 30 August resistance aspect.
1986 FDA50734 2005

BD-AF Hilti HST-R Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Part : N/A ETS-Testconsult FDA51018 9 November 22/01/2007 The application is to be
stud anchor subject to axial 1993 Limited 2005 considered individually
082 Liechtenstein tension and shear with regard to the fire
M16 BS 5080: Part 2: 14 November resistance aspect.
1986 FDA51078 2005

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection BS 5080: Part : N/A ETS-Testconsult FDA61246 6 September 22/01/2007 The application is to be
500 injection for chemical adhesive anchor 1993 Limited 2006 considered individually
083 Kaufering, Germany fastening with grade
adhesive with subject to axial with regard to the fire
HAS ER M16 A4 stainless steel tension and BS 5080: Part 2: 6 September resistance aspect.
1986 FDA61252 2006
rods rod. shear.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF MKT Wedge Metall-Kunststoff- Hot dip galvanized Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 053357ST51586 9 February 22/01/2007 The application is to be
Anchor B8 Technik GmbH & steel subject to axial 1993 Services Limited 2006 considered individually
084
(setting depth Co. KG tension and with regard to the fire
/embedded shear. BS 5080: Part 2: 9 February resistance aspect.
Weilerbach, 1986 053357ST51586 2006
length: 55mm)
Germany (1)
Anchor
diameter: 8mm

BD-AF MKT Wedge Metall-Kunststoff- Hot dip galvanized Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 053357ST51595 9 February 22/01/2007 The application is to be
Anchor B10 Technik GmbH & steel subject to axial 1993 Services Limited 2006 considered individually
085
(setting depth Co. KG tension and with regard to the fire
/embedded shear. BS 5080: Part 2: 9 February resistance aspect.
Weilerbach, 1986 053357ST51595 2006
length: 60mm)
Germany (1)
Anchor
diameter:
10mm

BD-AF MKT Wedge Metall-Kunststoff- Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 993114ST10286 26 March 22/01/2007 The application is to be
Anchor subject to axial 1993 Services Limited 2001 considered individually
086 Technik GmbH &
B10-20/90 tension and with regard to the fire
Co. KG shear. BS 5080: Part 2: 11 August resistance aspect.
1986 993114ST10286 2003
Weilerbach,
(1)C
Germany
BD-AF MKT Wedge Metall-Kunststoff- Stainless steel A4 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 993114ST10286 11 August 22/01/2007 The application is to be
Anchor subject to axial 1993 Services Limited (2)B 2003 considered individually
087 Technik GmbH & tension and with regard to the fire
B12-15/110 Co. KG shear. BS 5080: Part 2: 993114ST10286 11 August resistance aspect.
1986 (3)B 2003
Weilerbach,
Germany
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HSL-GR Hilti Corporation Stainless steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50394A 24 May 2005 25/04/2007 The application is to be
Heavy Duty subject to axial 1993 Limited considered individually
088 Nuziders, Austria
Anchor tension and with regard to the fire
shear. BS 5080: Part 2: N/A FDA50425 26 May 2005 resistance aspect.
M10 1986

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61247 29 August 25/04/2007 The application is to be
500 injection for chemical adhesive anchor 1993 Limited 2006 considered individually
089 Kaufering, Germany fastening with grade
adhesive with subject to axial with regard to the fire
HAS ER M20 A4 stainless steel tension and BS 5080: Part 2: N/A FDA61253 29 August resistance aspect.
rods rod. shear. 1986 2006

BD-AF Ramset ITW Red Head Epoxy injection Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA70419A 28 February 25/04/2007 The application is to be
EPCON G5 system for fastening adhesive anchor 1993 Limited 2007 considered individually
090 Illinois, USA
injection grout of M16 A4-80 subject to axial with regard to the fire
with M16 stainless steel anchor tension and BS 5080: Part 2: N/A FDA70388A 28 February resistance aspect.
A4-80 stud shear. 1986 2007
Stainless steel
Anchor Stud

BD-AF Ramset ITW Red Head Epoxy injection Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA70317B 13 February 18/10/2007 The application is to be
EPCON G5 system for fastening adhesive anchor 1993 Limited 2007 considered individually
091 Illinois, USA
injection grout of M30 Grade 8.8 subject to axial with regard to the fire
with M30 anchor stud tension and BS 5080: Part 2: N/A FDA70316B 13 February resistance aspect.
Grade 8.8 shear. 1986 2007
Anchor Stud

BD-AF Ramset Ramset Fasteners Grade 316 stainless Heavy duty BS 5080: Part 1: HOKLAS ETS-Testconsult FDA51140A 22 Nov 2005 18/10/2007 The application is to be
FDA60635 17 May 2006
Trubolt (Aust) Pty Limited Steel torque setting 1993 Limited considered individually
092
T10090SS expansion with regard to the fire
(M10 x90mm) Melbourne, Australia anchor subject to BS 5080: Part 2: N/A resistance aspect.
1986 FDA60637 17 May 2006
& T12140SS axial tension and FDA60638 17May 2006
(M12x140mm) shear

BD-AF Ramset ITW Red Head Epoxy injection Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50334 16 April 18/10/2007 The application is to be
EPCON G5 system for fastening adhesive rebar 1993 Limited 2005 considered individually
093 Illinois, USA
injection grout of Y32 and Y40 subject to axial with regard to the fire
with Y32 and rebar tension only N/A FDA50335 16 April resistance aspect.
Y40 rebar 2005
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HSA-R Hilti Corporation Stainless Steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50776 27 July 2005 18/10/2007 The application is to be
Stud Anchor subject to axial 1993 Limited considered individually
094 Schaan,
M8 tension and with regard to the fire
Liechtenstain shear. BS 5080: Part 2: N/A FDA50728 8 August resistance aspect
1986
2005

BD-AF Hilti HSC-IR Hilti Corporation Stainless Steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA51054 27 October 18/10/2007 The application is to be
2005
Safety Anchor Internal Thread subject to axial 1993 Limited considered individually
095 Guangdong, China
M10 tension and 8 November with regard to the fire
shear. BS 5080: Part 2: N/A FDA51035 resistance aspect
1986 2005

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection system BS 5080: Part 1: N/A Fugro Technical 020323ST20493 12 June 2002 21/1/2008 The corresponding fire
500 for making 1993. Services Limited assessment report no. WF
096 Kaufering, Germany 020323ST20500
nominal 166402 is valid until 1
anchorage November 2012
020323ST20501
connections of
Grade 460 rebars Load carrying capacity of
020323ST20510
of diameters up the injection system for
to 40mm in 020323ST20538 rebar fixing under the
reinforced effects of fire should be
concrete 020323ST20593 assessed with an
elements up to 2 appropriate factor of
hrs. FRP. 020323ST20607 safety compatible with the
structural design of the
parent structure.

Reference can also be


made to ref. BD-FP 077 -
Fire Protection Material
for Structural Use.

BD-AF Hilti HSL-G-R Hilti Corporation Stainless Steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50466A 28 October 21/1/2008 The application is to be
Heavy Duty subject to axial 1993 Limited 2005 considered individually
097 Nuziders, Austria
Anchor tension and with regard to the fire
M20/30 shear. BS 5080: Part 2: N/A FDA50433 8 June 2005 resistance aspect
1986
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Fischer Anchor Fischerwerke Artur Stainless Steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS Castco Testing I001503M00355 7 March 2003 31/1/2008 The application is to be
FBN-Bolt (A4) Fischer GmbH & Co subject to axial 1993 with Centre Ltd. BD/MISCEL 4 March 2006 considered individually
098
M8/48, KG tension and modification for 260301-1 with regard to the fire
M10/50, shear. M8, M10 resistance aspect
M12/70 Waldachtal, I001503M00355 7 March 2003
& M16/84 Germany In-house method BD/MISCEL 3 November
based on BS HOKLAS 251027-8 2005
5080: Part 1:
1986 for M12, BD/MISCEL
M16 270228-2 10 May 2007
BD/MISCEL 7 June 2007
BS 5080: Part 2: N/A 270228-6
1986 for M12
BD/MISCEL 2 October
In-house method N/A 240930-2 2004
based on BS BD/MISCEL 15 June 2005
5080: Part 2: 250512-12
1986 for M8,
M10, M16

BD-AF Fischer Anchor Fischerwerke Artur Stainless Steel A4 Drill-in anchors In-house method HOKLAS Castco Testing BD/MISCEL 10 May 2007 31/1/2008 The application is to be
FAZ-Anchor Fischer GmbH & Co subject to axial based on BS Centre Ltd. 270228-1 considered individually
099
Bolt (A4) M8 KG tension and 5080: Part 1: with regard to the fire
shear. 1993 BD/MISCEL resistance aspect
Waldachtal, 270228-4 7 June 2007
N/A
Germany BS 5080: Part 2:
1986

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61082 10 August 25/04/2008 The application is to be
500 injection for chemical adhesive anchor 1993 Limited 2006 considered individually
100 Kaufering, Germany fastening with grade
adhesive with subject to axial with regard to the fire
HAS-ER M24 A4 stainless steel tension and BS 5080: Part 2: N/A FDA61314 30 September resistance aspect.
rods rod. shear. 1986 2006
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Upat EXA Fischerwerke Artur Zinc-plated steel, or Drill-in anchors BS 5080: Parts 1 N/A University of Hong AN5 July 1991 22/7/2008 It should be read in
Express Fischer GmbH & Co hot-dipped subject to axial &2 Kong, Department AN6 conjunction with BD-AF
101
Anchor KG galvanized steel. tension and of Civil and 026
shear. Structural AN20
M8 Waldachtal, November Note on change of
Engineering AN22
Germany 1991 manufacturer.

(See remarks)

BD-AF Hilti HKD-SR Hilti Corporation Stainless Steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50718A 9 September 22/7//2008 Overall FOS shall not be
Push-in subject to axial 1993 Limited 2005 less than 3.0.
102 Nuziders, Austria
Anchor M10 tension and Manufactured shall be
A4 shear. BS 5080: Part 2: 20 September consulted in this aspect
1986 N/A FDA50790A 2005 for design.

The application is to be
considered individually
with regard to the fire
resistance aspect

BD-AF Fischer Anchor Fischerwerke Artur Hot-dipped Drill-in anchors BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 27 September 22/7/2008 Recommended load for
FBN M10/15 Fischer GmbH & Co galvanized steel subject to axial 1993 Centre Ltd. 240925-1 2004 design shall be
103
fvz KG tension and determined from dividing
shear. BS 5080: Part 2: BD/MISCEL 28 September the characteristic load by
Waldachtal, 1986 N/A 240923-9 2004 a FOS 3.0.
Germany
The application is to be
considered individually
with regard to the fire
resistance aspect
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 10 May Recommended load for
BD-AF Fischer Anchor Fischerwerke Artur Stainless Steel A4 Drill-in anchors 22/7/2008
1993 Centre Ltd. 270412-4 2007 design shall be
FAZ-Bolt (A4) Fischer GmbH & Co subject to axial
104 BS 5080: Part 2: N/A BD/MISCEL 7 June determined from dividing
M10, M12, KG tension and
1986 270228-3 2007 the characteristic load by
M16, M20 & shear.
Waldachtal, a FOS 3.0.
M24
Germany BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 16 December
1993 Centre Ltd. 251208-5 2005 The application is to be
BS 5080: Part 2: N/A BD/MISCEL 7 June considered individually
1986 270228-7 2007 with regard to the fire
resistance aspect
BS 5080: Part 1: HOKLAS Hong Kong SF – 0052R7283 5 February
1993 Curtain Wall 2005
BS 5080: Part 2: N/A Testing Centre Ltd SF – T0088R7283 5 February
1986 2005

BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 10 May


1993 Centre Ltd. 270412-5 2007
BS 5080: Part 2: N/A BD/MISCEL 4 June
1986 270412-7 2007

BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 10 May


1993 Centre Ltd. 270412-6 2007
BS 5080: Part 2: N/A BD/MISCEL 4 June
1986 270412-8 2007
BD-AF Ramset Ramset Fasteners Grade 316 stainless Heavy duty BS 5080: Part 1: HOKLAS ETS-Testconsult FDA60636 24 May 2006 22/7/2008 The application is to be
Trubolt (Aust) Pty Limited Steel torque setting 1993 Limited considered individually
105
T16175SS expansion with regard to the fire
(M16 Melbourne, Australia anchor subject to BS 5080: Part 2: resistance aspect.
1986 N/A FDA60639 24 May 2006
x125mm) axial tension and
shear

BD-AF Ramset ITW Red Head Epoxy injection Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50330 (for 23 April 2005 22/7/2008 The application is to be
EPCON G5 system for fastening adhesive anchor 1993 Limited Y12) considered individually
106 Illinois, USA
injection grout of Y12 & Y16 high subject to axial with regard to the fire
with Y12 & yield dowel bar tension only FDA 50331(for resistance aspect.
Y16) 23 April 2005
Y16 high yield
dowel
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Fischer Anchor Fischerwerke Artur Hot-dipped Drill-in anchors BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 21 September 22/10/2008 Recommended load for
FBN M12/15 Fischer GmbH & Co galvanized steel subject to axial 1993 Centre Ltd. 240917-6 2004 design shall be
107
fvz KG tension and determined from dividing
shear. BS 5080: Part 2: BD/MISCEL 28 September the characteristic load by
Waldachtal, 1986 N/A 240923-10 2004 a FOS 3.0.
Germany
The application is to be
considered individually
with regard to the fire
resistance aspect

BD-AF Hilti HIT-HY Hilti Corporation Hybrid resin system Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61360 22 September 22/10/2008 The application is to be
150 injection for fixing grade 5.8 adhesive anchor 1993 Limited 2006 considered individually
108 Kaufering, Germany galvanized steel rod.
adhesive with subject to axial with regard to the fire
HAS-E M16 tension and BS 5080: Part 2: 22 September resistance aspect.
1986 N/A FDA61367 2006
rods. shear.

BD-AF Hilti HCS M8 Hilti Corporation A2 – 304 stainless Cast-in socket BS 5080: Part 1: HOKLAS ETS-Testconsult FDA60243 7 March 2006 22/10/2008 The application is to be
x 40 Cast-in steel used as structural 1993 Limited considered individually
109 Kaufering, Germany
Socket fixing for M8 with regard to the fire
bolt/ threaded BS 5080: Part 2: resistance aspect.
1986 N/A FDA60239 7 March 2006
rod for fastening
of cladding. Tests for quality control
and workmanship may be
required during
construction.

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection BS 5080: Part 1: HOKLAS Qualitech Testing 20080730-BD-PL- 1 August 2008 23/1/2009 The application is to be
500 injection for chemical adhesive anchor 1993 & Consultancy 02 considered individually
110 Kaufering, Germany fastening with grade
adhesive with fixed on Limited. with regard to the fire
HAS-ER M8 A4 stainless steel brickwork BS 5080: Part 2: 20080730-BD-S-0 resistance aspect.
1986 N/A 4 1 August 2008
and M10 rods rod. subject to axial
tension and
shear.

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin system Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61084 10 August 23/1/2009 The application is to be
500 injection for chemical adhesive anchor 1993 Limited 2006 considered individually
111 Kaufering, Germany fastening with grade
adhesive with subject to axial with regard to the fire
HAS-ER M33 A4 stainless steel tension and BS 5080: Part 2: 24 August resistance aspect.
1986 N/A FDA61168 2006
rods rod. shear.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Ramset Ramset Fasteners Grade304 stainless Cast-in insert BS 5080: Part 1: HOKLAS ETS-Testconsult FDA81285 20 October 23/1/2009 The application is to be
Concrete Insert (Aust) Pty Limited Steel used as structural 1993 Limited 2008 considered individually
112
CIM10SS fixing for M10 with regard to the fire
Melbourne, Australia bolt/ threaded BS 5080: Part 2: 20 October resistance aspect.
1986 N/A FDA81277 2008
rod for fastening
Tests for quality control
and workmanship may be
required during
construction.

BD-AF Nelton Shanghai Sishun Galvanized mild Cast-in channel BS 5080: Part 1: HOKLAS Fugro Technical 082615ST 9 December 23/1/2009 The application is to be
Tanchor Industry & Trade Co. steel with inserted 1993 Service Ltd. 80814 2008 considered individually
113
Channel – Ltd. T-bolt subject to with regard to the fire
HBC-52/26(30 Channel: Grade axial tension and BS 5080: Part 2: 082615ST 9 December resistance aspect.
Shanghai, China N/A
03) with T-bolt Q235B shear 1986 80814(1) 2008
HB-M16 Tests for quality control
Anchor stud : Grade and workmanship may be
Q195 required during
construction.
T-bolt : Grade 8.8

BD-AF Ramset ITW Red Head Acrylic chemical Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA81100 (for 4 September 23/1/2009 The application is to be
EPCON A7 injection for A4 adhesive anchor 1993 Limited M8 in tension) 2008 considered individually
114 Illinois, USA
Injection stainless steel anchor stud subject to with regard to the fire
Adhesive with bolt axial tension and BS 5080: Part 2: FDA 81101(for 4 September resistance aspect.
1986 N/A M16 in tension) 2008
shear
M8 A4-80
Stud and FDA81280 (for 20 October
M16 A4-80 M8 in shear 2008
Stud
FDA 81283(for 20 October
M16 in shear) 2008
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Ramset TRIGA SPIT A4 Stainless Steel Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA81424 (for 25 November 23/1/2009 The application is to be
Z-A4 Heavy subject to axial 1993 Limited M8 in tension) 2008 considered individually
115 France
Duty Anchor tension and with regard to the fire
M8, M10, shear. BS 5080: Part 2: FDA61177 (for 24 August resistance aspect.
1986 N/A M10 in tension) 2006
M12 & M16

V8-12/25 FDA61178 (for 24 August


V10-15/25 M12 in tension) 2006
V12-18/25
FDA61179 (for 24 August
E16-24/25
M16 in tension) 2006

FDA81425 (for 25 November


M8 in shear) 2008

FDA61180 (for 24 August


M10 in shear) 2006

FDA61181 (for 24 August


M12 in shear) 2006

FDA61182 (for 24 August


M16 in shear) 2006

BD-AF Fischer Anchor Fischerwerke Artur Hot-dipped Drill-in anchors BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 21 September 30/4/2009 Recommended load for
FBN M8/10 Fischer GmbH & Co galvanized steel subject to axial 1993 Centre Ltd. 240917-4 2004 design shall be
116
fvz KG tension and determined from dividing
shear. BS 5080: Part 2: BD/MISCEL 21 February the characteristic load by
Waldachtal, 1986 N/A 250219-1 2005 a FOS 3.0.
Germany
The application is to be
considered individually
with regard to the fire
resistance aspect
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HVU Hilti Corporation Urethane Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61170A 30 August 30/4/2009 The application is to be
adhesive methacrylate resin adhesive anchor 1993 Limited 2006 considered individually
117 Kaufering, Germany
capsule with for chemical subject to axial with regard to the fire
HAS-ER- M24 fastening with tension and BS 5080: Part 2: 22 September resistance aspect.
1986 N/A FDA61366 2006
anchor rod grade A4 stainless shear.
steel anchor rod

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61245 6 September 12/8/2009 The application is to be
500 injection system for adhesive anchor 1993 Limited 2006 considered individually
118 Kaufering, Germany
adhesive with chemical fastening subject to axial with regard to the fire
HAS-ER M12 with grade A4 tension and BS 5080: Part 2: 6 September resistance aspect.
1986 N/A FDA61251 2006
rods stainless steel rod. shear.

BD-AF Fischer Anchor Fischerwerke Artur Hot-dipped Drill-in anchors BS 5080: Part 1: HOKLAS Castco Testing BD/MISCEL 17 January 12/8/2009 Recommended load for
FBN M16/25 Fischer GmbH & Co galvanized steel subject to axial 1993 Centre Ltd. 250112-52 2005 design shall be
119
fvz KG tension and determined from dividing
shear. BS 5080: Part 2: BD/MISCEL 17 January the characteristic load by
Waldachtal, 1986 N/A 250115-1 2005 a FOS 3.0.
Germany
The application is to be
considered individually
with regard to the fire
resistance aspect

BD-AF Hilti HSC-IR Hilti Corporation Stainless Steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA51056 14 November 4/11/2009 The application is to be
2005
Safety Anchor Internal Thread subject to axial 1993 Limited considered individually
120 Guangdong, China
M12 tension and 14 November with regard to the fire
shear. BS 5080: Part 2: FDA51037 resistance aspect
N/A 2005
1986

BD-AF Hilti HSC-IR Hilti Corporation Stainless Steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA51053 14 November 22/2/2010 The application is to be
2005
Safety Anchor Internal Thread subject to axial 1993 Limited considered individually
121 Guangdong, China
M8 tension and 14 November with regard to the fire
shear. BS 5080: Part 2: N/A FDA51034 resistance aspect
1986 2005

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin Injection BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61172 24 August 3/5/2010 The application is to be
500 injection system for adhesive anchor 1993 Limited 2006 considered individually
122 Kaufering, Germany FDA61174
adhesive with chemical fastening subject to axial with regard to the fire
HAS-ER A4 with grade A4 tension and BS 5080: Part 2: resistance aspect.
1986 N/A FDA61171
M30 and M39 stainless steel rod. shear.
stainless steel FDA61169
anchor rod
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Sampag TSA Sampag Anchoring Galvanized Cast-in channel BS 5080: Part 1: HOKLAS Castco Testing BD 0091007-12 to 14 July 2009 25/8/2010 The application is to be
Anchor Systems Ltd. hot-rolled carbon with inserted 1993 Centre Ltd 16 considered individually
123 14 October
Channel 41/25 Hong Kong, China steel T-bolt subject to with regard to the fire
with 2Nos axial tension and BS 5080: Part 2: BD 0090710-1 to 2009 resistance aspect.
Channel: Grade 1986 N/A 5
Grade 4.6 ZP shear
M16 T-bolt S235JRG2 to Tests for quality control
EN10025 BD0090710-16 to and workmanship may be
& Anchor
20 required during
Channel 51/31
Anchor stud : construction.
with 2Nos BD 0091007-17 to
Grade S235JRG2
Grade 4.6 ZP 21
to EN10025
M20 T-bolt
T-bolt : Grade 4.6 BD 0090710-6 to
to EN ISO 898-1 10
Zinc Plated
BD 0090710-11 to
15

BD-AF Hilti HIT-RE Hilti Corporation Epoxy resin Injection system BS 5080: Part 1: HOKLAS ETS-Testconsult FDA61246 6 September 17/10/2011 The assessment report no.
500 injection system for for making 1993 Limited 2006 WFRC No. C121086 is
124 Kaufering, Germany FDA61252
adhesive with chemical fastening nominal valid until 1 October
HAS-E M16, with grade 8.8 anchorage BS 5080: Part 2: 6 September 2007.
1986 N/A FDA61247 2006
M20, M24 & threaded rod. connections of
M33 Grade 8.8 Grade 8.8 Load carrying capacity of
FDA61253 6 September
threaded rod threaded rod in the injection system for
FDA61082 2006 rebar fixing under the
reinforced
concrete effects of fire should be
FDA61314 6 September
elements up to 2 assessed with an
2006
hrs. FRP. appropriate factor of
FDA61084 10 August
safety compatible with the
2006
FDA61168 structural design of the
30 September
parent structure.
2006
10 August
2006
24 August
2006
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HST-R Hilti Corporation Stainless steel A4 Drill-in anchors ETAG001 Dakks/ ILAC University of NR 02.02.38 25 Sept 2002 17/10/2011 The application is to be
M12 stud subject to axial Dortmund considered individually
125 Kaufering, Germany NR 02.02.51 24 Jan 2003
anchor tension and shear with regard to the fire
for both cracked resistance aspect.
and uncracked
concrete

BD-AF Hilti HSA M6 Hilti Corporation Galvanized carbon Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50580 25 July 2005 17/10/2011 The application is to be
anchor bolt Kaufering, Germany steel subject to axial 1993 Limited considered individually
126 FDA50676 11 August
tension and shear with regard to the fire
for uncracked BS 5080: Part 2: 2005 resistance aspect.
1986 N/A
concrete.

BD-AF Hilti HST-R Hilti Corporation Stainless steel A4 Drill-in anchors ETAG001 Dakks/ ILAC University of NR 02.02.38 25 September 17/10/2011 The application is to be
M10, M16 subject to axial Dortmund 2002 considered individually
127 Kaufering, Germany NR 02.02.51
anchor bolt tension and shear with regard to the fire
for both cracked 24 January resistance aspect.
and uncracked 2003
concrete

BD-AF Hilti HSL-3 Hilti Corporation Galvanized carbon Drill-in anchors ETAG001 COFRAC CSTB NR 02.02.38 25 September 17/10/2011 The application is to be
M10 anchor steel subject to axial 2002 considered individually
128 Kaufering, Germany NR 02.02.51
bolt tension and shear with regard to the fire
for both cracked 24 January resistance aspect.
and uncracked 2003
concrete

BD-AF Hilti HSA M10 Hilti Corporation Galvanized carbon Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA01776 31 December 21/9/2012 The application is to be
and M12 stud Kaufering, Germany steel subject to axial 1993 Limited 2010 considered individually
129 FDA01777
anchor tension and shear with regard to the fire
for uncracked BS 5080: Part 2: FDA01778 resistance aspect.
1986 N/A
concrete.
FDA01779

BD-AF Hilti HST-R Hilti Corporation Stainless steel Drill-in anchors ETAG001 Dakks/ ILAC University of NR 02.02.38 25 September 21/9/2012 The application is to be
M8, M12 and Kaufering, Germany subject to axial Dortmund 2002 considered individually
130 NR 02.02.51
M16 anchor tension and shear with regard to the fire
bolt for cracked and 24 January resistance aspect.
uncracked 2003
concrete.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Nelton Shanghai Sishun Galvanized mild Cast-in channel BS 5080: Part 1: HOKLAS ETS-Testconsult FDA11449 9 December 21/9/2012 The application is to be
Tanchor Industry & Trade Co. steel with inserted 1993 Limited 2008 considered individually
131 101164ST100529(
Channel – Ltd. T-bolt subject to with regard to the fire
HBZ-52/26(35 Channel: Grade axial tension and BS 5080: Part 2: Fugro Technical 3) 9 December resistance aspect.
Shanghai, China N/A
04) with 2Nos. Q235B shear 1986 Service Ltd 2008
HB-M16
Anchor stud :
T-bolt
Grade Q195

T-bolt : Grade 8.8

BD-AF Hilti Anchor Hilti Corporation Channel: hot-dip Cast-in channel BS 5080: Part 1: HOKLAS ETS-Testconsult FDA 10910 9 June 2011 21/9/2012 The application is to be
Channel Kaufering, Germany galvanized mild with inserted 1993 Limited considered individually
132
steel grade S235 to T-bolt subject to with regard to the fire
Channel - Type BS EN 10025-2 axial tension and BS 5080: Part 2: ETS-Testconsult resistance aspect.
HAC-60 with 1986 N/A Limited FDA 10911 8 June 2011
shear for cracked
2Nos. HBC-C Bolt: grade 8.8 and uncracked
CUAP 06.01/01 Dakks/ ILAC Hilti AG P8Q-066 23 August
M16 bolts steel concrete.
Common 2011
Understanding
of Assessment
Procedure for
ETA-Anchor
Channels

BD-AF Hilti HSL-3 Hilti Corporation Galvanized grade Drill-in anchors ETAG001 COFRAC CSTB ER 553 00 2 October 21/1/2013 The application is to be
M16 anchor 8.8 steel subject to axial 0520/part1 2002 considered individually
133 Nuziders, Austria
bolt tension and shear with regard to the fire
for both cracked resistance aspect.
and uncracked
concrete
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti Anchor Hilti Corporation Channel: hot-dip Cast-in channel BS 5080: Part 1: HOKLAS ETS-Testconsult FDA 10649 18 April 2011 21/1/2013 The application is to be
Channel Kaufering, Germany galvanized mild with inserted 1993 Limited considered individually
134 FDA 10804 20 May 2011
steel grade S235 to T-bolt subject to with regard to the fire
Channel - Type BS EN 10025-2 axial tension and resistance aspect.
HAC-50 with shear for cracked
2Nos. HBC-C Bolt: grade 8.8 and uncracked
M16 bolts & steel BS 5080: Part 2: N/A ETS-Testconsult FDA 10650 18 April 2011
concrete. 1986 Limited
Type HAC-70 FDA 10805 20 May 2011
with 2Nos.
HBC-C M16
bolts
CUAP 06.01/01 Dakks/ ILAC Hilti AG P8Q-066 23 August
Common 2011
Understanding
of Assessment
Procedure for
ETA-Anchor
Channels

BD-AF Nelton Shanghai Sishun Galvanized mild Cast-in channel BS 5080: Part 1: HOKLAS ETS-Testconsult FDA11647 9 September 2/4/2013 The application is to be
Tanchor Industry & Trade Co. steel with inserted 1993 Limited 2011 considered individually
135 101164ST100529(
Channel – Ltd. T-bolt subject to with regard to the fire
HBZ-52/26(35 Channel: Grade axial tension and BS 5080: Part 2: Fugro Technical 1) 13 January resistance aspect.
Shanghai, China N/A
03) with 2Nos. Q235B shear 1986 Service Ltd 2011
HB-M16
Anchor stud :
T-bolt
Grade Q195

T-bolt : Grade 8.8

BD-AF Hilti HDA-TR Hilti Corporation Stainless steel Drill-in anchors ETAG001 COFRAC CSTB ER 553 15 June 1999 3/7/2013 The application is to be
M12x125/30 subject to axial 97022/part1 considered individually
136 Liechtenstein
anchor bolt tension and shear with regard to the fire
for both cracked resistance aspect.
and uncracked
concrete
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Sampag TSA Sampag Hot-dip galvanized Cast-in channel BS 5080: Part 1: HOKLAS Castco Testing BD 0091215-22 to 16 August 13/8/2013 The application is to be
Anchor International Limited carbon steel with inserted 1993 Centre Ltd 24 2012 considered individually
137
Channel T-bolt subject to with regard to the fire
51/31L with Hong Kong, China Channel: Grade axial tension and BS 5080: Part 2: BD 0091215-26 resistance aspect.
2Nos Type TS S235JRG2 to shear 1986
EN10025 BD 0091007-30
50 M20 Grade
8.8 T-bolt BD 0101027-11 to
Anchor stud :
Grade S235JRG2 15
to EN10025

T-bolt : Grade 8.8


to EN ISO 898-1

BD-AF Hilti Anchor Hilti Corporation Channel: hot-dip Cast-in channel BS 5080: Part 1: HOKLAS ETS-Testconsult FDA 10588 8 April 2011 13/8/2013 The application is to be
Channel galvanized mild with inserted 1993 Limited considered individually
138 Liechtenstein steel grade S235 to T-bolt subject to with regard to the fire
Channel - Type BS EN 10025-2 axial tension and BS 5080: Part 2: ETS-Testconsult resistance aspect.
HAC-40 with 1986 N/A Limited FDA 10589 8 April 2011
shear for cracked
2Nos. HBC-C Bolt: grade 8.8 and uncracked
CUAP 06.01/01 Dakks/ ILAC Hilti AG P8Q-066 23 August
M16 bolts steel concrete.
Common 2011
Understanding
of Assessment
Procedure for
ETA-Anchor
Channels
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Ramset CIM Ramset Fasteners Grade 316 Cast-in insert BS 5080: Part 1: HOKLAS ETS-Testconsult FDA 60786 22 June 2006 17/10/2013 The application is to be
139 Concrete Insert (Aust) Pty Limited stainless steel subject to axial 1993 Limited considered individually
Melbourne, Australia tension and shear with regard to usage with
M12 for cracked and BS 5080: Part 2: ETS-Testconsult fire resistance and in
1986 N/A Limited FDA 60787 22 June 2006
uncracked cracked concrete.
concrete
No test/ assessment report
was provided for
application in cracked
concrete

BD-AF Ramset Fix Z ITW SPIT Stainless steel A4 Drill-in anchors BS 5080: Part 1: HOKLAS ETS-Testconsult FDA91236 23 October 14/2/2014 The application is to be
140 A4 anchor bolt subject to axial 1993 Limited 2009 considered individually
Valence, France tension and shear with regard to the fire
M10 for both cracked BS 5080: Part 2: ETS-Testconsult 23 October resistance aspect.
1986 N/A Limited FDA91237 2009
and uncracked
concrete COFRAC ER 553 02
ETAG001 CSTB 3 June 2003
0506/part1

BD-AF Fischer FAZ II Fischerwerke GmbH Stainless steel A4 Drill-in anchors ETAG001 bmwfj BOKU – IKI ER1 February 2005 14/2/2014 The application is to be
141 Anchor bolt & Co. KG subject to axial considered individually
tension and shear ER3 30 June 2008 with regard to the fire
M8, M10, Waldachtal, for both cracked resistance aspect.
M12 & M16 Germany and uncracked
concrete

BD-AF Halfen HZA Halfen GmbH & Co. Channel: hot rolled Cast-in channel BS 5080: Part 1: HOKLAS Fugro Technical 090077ST90036 20 May 2009 14/2/2014 The application is to be
Cast-in KG S275JR with inserted 1993 Service Ltd considered individually
142
Channel T-head bolt with regard to the fire
Langenfeld, Bolt: grade 8.8 subject to axial BS 5080: Part 2: Fugro Technical resistance aspect.
Type HZA Germany 1986 N/A Service Ltd 090077ST90036 20 May 2009
tension and shear
41/27 350mm (1)
for uncracked
with 2Nos. HS concrete.
38/23 M16
T-head bolts
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Accreditation Assessing Report
Country)
Body Organization
BD-AF Ramset ITW Red Head Epoxy injection Injection system BS 5080: Part 1: HOKLAS ETS-Testconsult FDA50330 23 April 2005 01/09/2014 The corresponding fire
143 EPCON G5 system for making 1993 Limited assessment review report
Injection Illinois, USA anchorage FDA50331 23 April 2005 no. 25276-00 is valid until
Adhesive with connections of 30 November 2015.
FDA50332 23 April 2005
Grade 460 high Grade 460 rebars
yield deformed of diameters Load carrying capacity of
FDA50333A 19 May 2005
bars of 12mm to 40mm the injection system for
diameters in reinforced FDA50334 23 April 2005 rebar fixing under the
12mm to concrete effects of fire should be
40mm elements up to 4 FDA50335 23 April 2005 assessed with an
hrs. FRP. appropriate factor of safety
compatible with the
structural design of the
parent structure.

Reference can also be


made to ref. BD-FP 128 -
Fire Protection Material
for Structural Use.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Accreditation Assessing Report
Country)
Body Organization
BD-AF Sunway Sunway Metal Grade 304/316 Drill-in anchors BS 5080: Part 1: N/A Fugro Technical 124675ST130008 28 May 2013 1/12/2014 Test methods were not
Anchor Bolt Manufactory stainless steel subject to axial 1993 and Service Ltd (9) to (11) within the scope of
144
tension and shear ETAG-001- HOKLAS accreditation of
SW-E8, Hong Kong for both cracked Annex-A Fugro Technical Service
SW-E10 & and uncracked Ltd.
SW-E12 BS 5080: Part 2: N/A Fugro Technical 124675ST130008 28 May 2013
concrete
1986 and Service Ltd (6) to (8) Reliability/Suitability tests
ETAG-001- to ETAG 001 and
Annex-A evaluation on
124675ST130008 28 May 2013 reliability/suitability test
BS 5080: Part 1: N/A Fugro Technical
(3) to (5) results have not been
1993 and Service Ltd
carried out.
in-house method 113700ST110717, 16 February
STMS-2991 113700ST110717 2012 The application is to be
which refers to (1) & (2) considered individually
ETAG-001- with regard to the fire
Annex-A resistance aspect.

BS 5080: Part 2: N/A Fugro Technical 124675ST130008, 28 May 2013


1986 and Service Ltd 124675ST130008
in-house method (1) & (2)
STMS-3131
114392ST120023 10 April 2012
which refers to
ETAG-001- 114392ST120023 20 April 2012
Annex-A (2)
(See Remarks)
120188ST120147 1 June 2012

BD-AF Hilti Anchor Hilti Corporation Channel: hot-dip Cast-in channel BS 5080: Part 1: HOKLAS ETS-Testconsult FDA 22371 10 December 5/1/2015 The application is to be
Channel galvanized mild with inserted 1993 Limited 2012 considered individually
145 Liechtenstein steel grade S235 T-bolt subject to with regard to the fire
Channel - Type to BS EN axial tension and BS 5080: Part 2: ETS-Testconsult 10 December resistance aspect.
HAC-40 with 1986 N/A Limited FDA 22362 2012
10025-2 shear for cracked
2Nos. HBC-C and uncracked
CUAP 06.01/01 Dakks/ ILAC Hilti AG P8Q-066 23 August 2011
M12 bolts Bolt: grade 8.8 concrete.
steel Common
Understanding of
Assessment
Procedure for
ETA-Anchor
Channels
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Accreditation Assessing Report
Country)
Body Organization
BD-AF Hilti HSC-IR Hilti Corporation Stainless steel Drill-in anchors ETAG001 COFRAC CSTB ER 553 00 17 June 2002 23/7/2015 The application is to be
M12 anchor subject to axial 0518/part1 considered individually
146 Schaan,
bolt tension and shear with regard to the fire
for both cracked resistance aspect.
Liechtenstein
and uncracked
concrete

BD-AF Halfen HTA Halfen GmbH Channel: hot rolled Cast-in channel BS 5080: Part 1: HOKLAS Fugro Technical 102162ST100410 18 October 24/8/2015 The application is to be
Cast-in S275JR with inserted 1993 Service Ltd 2010 considered individually
147 Langenfeld,
Channel T-head bolt with regard to the fire
Germany Bolt: grade 8.8 subject to axial BS 5080: Part 2: Fugro Technical 20 October resistance aspect.
Type HTA 1986 N/A Service Ltd 102162ST100410
tension and shear 2010
55/42 450mm (1)
with 2Nos. HS
50/30 M16
T-head bolts

BD-AF Hilti HST3-R Hilti Corporation Stainless steel A4 Drill-in anchors ETAG001 Akkreditierung Bautechnische 282/14 16 June 2015 12/5/2016 The application is to be
M16 anchor subject to axial Versuchsanstalt considered individually
148 Schaan, Austria
bolt tension and shear with regard to the fire
Liechtenstein for cracked and resistance aspect.
uncracked
concrete

BD-AF Hilti HST3-R Hilti Corporation Stainless steel A4 Drill-in anchors ETAG001 Akkreditierung Bautechnische 280/14 16 June 2015 30/12/2016 The application is to be
M10 & M12 subject to axial Austria Versuchsanstalt considered individually
149 Schaan, 281/14 16 June 2015
anchor bolts tension and shear with regard to the fire
Liechtenstein for cracked and resistance aspect.
uncracked Dakks Kiwa MPA Bautest A 9023a/2014 25 July 2014
concrete.
GmbH Augsburg
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF Hilti HSL-3 Hilti Corporation Galvanized grade Drill-in anchors ETAG001 COFRAC CSTB ER 553 00 2 October 20/2/2017 The application is to be
M8 & M12 8.8 steel subject to axial 0520/part1 2002 considered individually
150 Nuziders, Austria
anchor bolt tension and shear with regard to the fire
for both cracked resistance aspect.
and uncracked
concrete

BD-AF Hilti HST3-R Hilti Corporation Stainless steel A4 Drill-in anchors ETAG001 Akkreditierung Bautechnische 285/14 25 May 2015 30/3/2017 The application is to be
M8 anchor subject to axial Austria Versuchsanstalt considered individually
151 Schaan,
bolt tension and shear with regard to the fire
Liechtenstein for both cracked resistance aspect.
and uncracked
concrete.

BD-AF Hilti Hilti Corporation Hybrid urethane Drill-in BS 5080 HOKLAS ETS-Testconsult 653/2013 12 April 2013 21/4/2017 The application is to be
HIT-HY200 methacrylate injectable mortar Limited considered individually
152 Kaufering, Germany
injectable system for with regard to the fire
Mortar with (HIT-HY200 adhesive system chemical resistance aspect.
injectable Mortar) for chemical ETAG001/ DAkkS Kiwa MPA H253/02-12/18 30 March
HIT-Z-R M16 anchor subject to
fastening with ICC-ES AC 308 Bautest GmbH 2012
A4 threaded axial tension and
Zhangjiang, China Grade A4 stainless shear for both
rod
(HIT-Z-R M16 A4 steel threaded rod. cracked and
ETAG001/ COFRAC CSTB 24 February
threaded rod) EEM 10
uncracked
ICC-ES AC 308 26027562/B 2012
concrete

BD-AF Hilti HST3-R Hilti Corporation Stainless steel A4 Drill-in anchors ETAG001 Akkreditierung Bautechnische 127/15 28 July 2015 2/6/2017 The application is to be
M20 & M24 subject to axial Austria Versuchsanstalt considered individually
153 Schaan,
anchor bolts tension and shear with regard to the fire
Liechtenstein for both cracked resistance aspect.
305/15 25 January
and uncracked
2016
concrete.
Reference List of Structural Fixing BD-AF

Ref. Product Name of Material Application Compliance Details of Test or Assessment Report Date of Remarks /
No. Category Posting on Comments
Name Manufacturer Testing CDB
and Place of Standard
Name of Name of Report No. Date of Test /
Manufacture
Laboratory Laboratory / Assessment
(City and
Country) Accreditation Assessing Report
Body Organization
BD-AF
Hilti HIT-HY Hilti Corporation Hybrid urethane Drill-in ETAG001 DAkkS Kiwa MPA Bautest A 9036-39/2010 August 2012 18/8/2017 The application is to be
154 200 injectable methacrylate injectable GmbH considered individually
mortar with Schaan, adhesive grouting mortar system with regard to the fire
Grade 500 Liechtenstein system for grade for grade 500 resistance aspect.
EEM 10 July 2010,
rebars of 500 rebar rebar subject to
COFRAC CSTB 26027562/A Sept 2011
diameters of connection axial tension and
10mm and system shear for both
12mm cracked and
uncracked
concrete
BD-AF
Ramset Fix Z ITW SPIT Stainless steel A4 Drill-in anchors ETAG001 COFRAC CSTB ER 553 02 3 June 2003 27/11/2017 The application is to be
155 A4 anchor bolt subject to axial 0506/part1 considered individually
M16 Valence, France tension and shear with regard to the fire
for both cracked resistance aspect.
and uncracked
concrete
BD-AF
Sampag TSA Sampag Hot-dip Cast-in channel BS 5080: Part 1: HOKLAS Castco Testing BD0121217-1; 14/12/2012 27/11/2017 The application is to be
156 Anchor International galvanized carbon with inserted 1993 Centre Ltd Castco LRN: considered individually
Channel 51/31 Limited, Hong Kong steel T-bolts subjected BD0121206-38, with regard to the fire
with 2 Nos to axial tension 39, 40, 41, 42 resistance aspect.
type TS50 Shenzhen, China Channel: Grade and shear for
S235JR to BS 5080: Part 2: Fugro Technical 123044ST120483;
M16 T-bolts both cracked and HOKLAS 25/1/2013
EN10025 1986 Service Ltd Specimen ID: 4, 5,
uncracked
concrete 6, 11, 22
Anchor stud:
Grade S235JR to I.A.S. 12/8/2013
ASTM E 488 & Element Materials ESP013231P.5131
EN10025
ICC AC232 Technology, U.S.
Tee-Bolts:
Grade 8.8,
EN ISO 898-1

You might also like