19. CLICK FILE SELECT SAVE AS 1. (Windows Vista & Windows 7) 32. Press F1 (INPUT) to set info.

32. Press F1 (INPUT) to set info. On the screen.


20. FILENAME.txt then click SAVE 2. Right Click “My Computer” Icon on Desktop
Quick reference guide for NTS-315B/NTS-335R 33. PT# 3 Press(ENT) on the keypad
TO VIEW COORDINATE DATA DIRECT TO AUTO CAD 3. Select Properties SHORT PRESS TO POWER ON 34. PCODE :SPOT Press(ENT) on the keypad
21. CLICK TRANSFORM 4. Click Device Manager
22. SELECT CASS COORDINATE 600 5. Click Ports (COM & LPT) LONG PRESS TO POWER OFF 35.
36.
I.HT :1.540 Press(ENT) on the keypad
Press F4 (REP) get reading of a point
22. CLICK TRANSFORM 6. See Communication Port
Press Star Icon (
() ILLUMINATE THE SCREEN 37. Press F4 (SAVE)
23. SELECT CASS COORDINATE --› --›DXF 7. Ex: (COM1) FOR
FOR 335R
335R (Prism
(Prism less)
less) F1-(Back)
F1-(Back)to
toEDIT
EDIT
Tilt Over PRISM
PRISMMODE
MODEOPERATION Continues collecting data
How to change comm port number Press
Press TT on
OPERATION
onthe keypad F3-(NUMB/CHAR)
F3-(NUMB/CHAR)
Press Star Icon (
() the keypad If you set another station you must
DOWNLOAD DATA…USING SD CARD 1. Right Click “My Computer” Icon on Desktop Press F2 (Tilt)
Prism
Prism 
RECORD the Point number/PCODE/Remarks...
Non-Prism
Non-Prism 
1. TS FIRST PRESS M 2. Select Properties Press F3 (ON) Sheet
Sheet Ex. POINT 10________
2. PRESS F3 (MEMORY MGR.) 3. Click Device Manager Press F4 (OFF) Press
PressESC
ESCononthe
thekeypad
keypad
3. PRESS (SO) ON THE KEYPAD 2X 4. Click Ports (COM & LPT) Press ESC on the Keypad PCODET2________is the remarks
4. PRESS F2 (FILE OPERATION) 5. Right Click Prolific USB to SERIAL Press ESC to returned normal screen FOR
FOR Laser
Laser Plummet
Plummet Ex. Output: 10/T2
5. PRESS F2 (EMS→
(EMS→SD CARD) Press (
() 2x (ILLUMINATION)
TO
TOACTIVATE
ACTIVATELASER
LASERPLUMMET
PLUMMET
6. SELECT A FILE UP AND DOWN ARROW TO SELECT Press
PressStar
StarIcon
Icon(())
Press ESC to returned normal screen Press
Next Station Settings
7. SELECT A FILE WITH ( .PTS ) FILE EXTENSION PressF4
F4(LSR)
(LSR)
Press
PressF1
F1(ON)
OPEN OR CLOSED TRAVERSE PROCEDURES
8. PRESS ENT ON THE KEYPAD TOPO / TRAVERSE / SIDESHOT (ON)

OPEN OR CLOSED TRAVERSE PROCEDURES


Press
PressESC
ESC 1. Press M on the keypad
9. PRESS ENT ON THE KEYPAD 6. Click Properties 2. Press F1 (COLLECT DATA)
10. FINISHED 7. Select Port Setting (TAB) 1. Press M on the keypad
To select Data/folder name
11. OPEN SOUTH SOFTWARE 2. Press F1(COLLECT DATA)
 Press F2 (LIST)
3. Create File : ____________
Ex. FILE : ACE_________  Press  on the keypad (scroll up)
8. Click Advance  Create or type file name using keypad
 Press on the keypad (scroll down)
 F1(BACK) to edit
12. CLICK USB OPERATION  F2(LIST) to search existing file 3. Press ENT on the keypad to select/confirmed
9. Click Comm port number  F3 to change number to alpha numeric 4. Press F1 (INPUT OCC.PT#)
 Press ENT on the keypad) to confirm 5. Press F3 (OCC)
6. Input Point number using keypad
Or enter the file name you’ve created (selected)
10. Click (OK) and (OK) Ex. PT#:10______ current OCC point
4. Press ENT on the keypad to confirm
F1-(Back) 7. Press ENT on the keypad to confirm
11. Remove the cable in a second then insert 5. Press F1 (INPUT OCC. PT#) F1-(Back)to
toEDIT
EDIT
13. SELECT OPEN EMS memory file F3-(NUMB/CHAR) 8. Press F4 (YES) to confirm ( if it is correct)
again to re fresh the driver software. 6. Press F1 (INPUT) F3-(NUMB/CHAR) 9. Press F1 (INPUT) Edit information on the screen
7. PT# 1 Press(ENT) on the keypad 10. Press so keypad (scroll down) to select (2x)
8. PCODE T1 Press(ENT) on the keypad 11. I.HT ▶1.040 Press(ENT) on the keypad
9. I.HT 1.540 Press(ENT) on the keypad 12. Press F4 (SAVE)
10. Press F3 (OCC) 13. Press F4 (YES) to confirm F1-(Back)
F1-(Back)to
toEDIT
EDIT
11. Press F4 (NEZ) 14. Press F2 (BACKSIGHT) F3-(NUMB/CHAR)
Input Coordinate Assumed or True F3-(NUMB/CHAR)
15. Press F3 (BS)
12. NO :20000.000 Press(ENT) on the keypad 16. Input Point number using keypad
14. SELECT OPEN PTS (COORDINATE FILE) SURVEYTECH TRADING 13. EO :20000.000 Press(ENT) on the keypad
17.
Ex. PT#:1___ is your BS point
Press ENT to confirm
15. LOOK IN (SD CARD) 14. ZO :20.000 Press(ENT) on the keypad
16. CLICK THE DATA FILE NAME
SERVICE CENTER 15. Press F4 (SAVE) 18. Press F4 (YES)
17. CLICK OPEN 1F SURVEYTECH Bldg., 16. Press F4 (YES) F1-(Back)
F1-(Back)to
toEDIT
EDIT Calculated Angle will Display
17. Press F2: INPUT BACKSIGHT 19. Focus the target prism
#175 Ilocos Sur near Cor. Ilo-ilo Sts., 18. Press F1 (INPUT)
F3-(NUMB/CHAR)
F3-(NUMB/CHAR)
20. Press F4 (YES) to release/confirm (SET)
Bago Bantay, Quezon City, Philippines 19. PT# ▶2 Press ENT on the keypad 21. Press F4 (MEAS)
20. PCODE: ▶ TX____ Press ENT on the keypad 22. Press F3 (NEZ)
Tels. (02)453-9426/359-8128  Press F3 (STOP) to end reading
21. R.Ht : ▶1.045 m Press ENT on the
Mobile. 0917-956-2410 | Website. keypad  Press F2 (PLOT) to view data points
www.surveytechtrading.com 22. Press F3 (BS)  Press F4 (SAVE) to store data
23. Press F4 (NEZ) 23. Press F4 (SAVE)
input true coordinate if they have, if not? …REWRITE? [NO] [YES]…
SAVE DATE IN ANY EXTENSION FILE LIKE CSV, TXT, DXF 24. Press F4 (ANG) 24. Press F3 [NO]
Technical Staff: Roger Roluna 25. Press F3 (MEASURE) 2
18. CLICK FILE SELECT SAVE AS Input or type “0” or 180 on the keypad to orient due north
19. FILENAME.csv then click SAVE Mobile (Globe) : 09053376118 25. Press ENT on the keypad to confirm  Edit the PCODE first
20. FILENAME.txt then click SAVE 26. Focus the target prism to set BS 26. Press F4 (REP) to get data
23. CLICK TRANSFORM Mobile (Smart) : 09496104314 27. Press F4 (YES) to release Continues collecting data
24. SELECT CASS COORDINATE 600 Email Address : odzing_mc@yahoo.com 28. Press F4 (MEAS) to select what data to save in If you set another station you must
24. CLICK TRANSFORM 29. Press F3 (NEZ) to get coordinate of your BS RECORD the Point number/PCODE/Remarks...
25. SELECT CASS COORDINATE --› --›DXF  Press F3 (STOP) to end reading Ex. POINT 67_________
 1
Press F2 (PLOT) to view data points
30. Press F4 (SAVE) PCODET9_________or remarks
How to Check Communication
7 Port Ex. Output: 67/T9
31. Press F3 (MEASURE)
28. F3 (NEZ) to get as built of the point 7. Press F4 (JUMP)
LAYOUT 29. F4 (NEXT) to set another point to Layout 8. Press F1:DIST RESECTION
1. Press so on the keypad 30. Do the same? Follow number 29 (Layout) 9. I.HT:_____ if needed Press ENT on the keypad
 Press F2 (LIST) if you have file in the internal REM-
REM- Remote Elevation Measurement 10. Pres F4 (NEZ)
12. Select Parameters
1. Press M Input coordinates of the first point (known)
memory
2. Press F2:PROGRAMS 11. N:20000.000 Press (ENT) on the keypad
 Press on the keypad (scroll up)
3. Press F1:REM 12. E:20000.000 Press (ENT)on the keypad
 Press  on the keypad (scroll down)
4. Press F2:NO PRISM HT 13. Z:20.000 Press (ENT)on the keypad
 Press ENT on the keypad to confirm 5. Focus the Target PRISM 14. R.HT: if needed Press (ENT) on the keypad
2. CreateFilename/Folder name 6. Press F1(MEAS) 15. FOCUS THE TARGET PRISM
3. Press ENT on the keypad to confirm 7. Press F4 (SET) 16. Press F1(MEAS)
4. Press F1: INPUT OCC.PT#  Protocol must be NONE
8. Focus the telescope to the first point 17. Press F4(NEZ)/input coordinates of the next point
 Input directly point number stored in mem Press F4 (SET)  Port number depend on the USB port assigning
9. (known)
 F2 (LIST) searching data on the memory 10. Tilt the telescope to the next point measure 18. N:20000.000 Press (ENT) on the keypad  Baud must be set according to TS settings

5. Press F4 (NEZ) / input coordinate VD:____ it will change 19. E:20000.000 Press (ENT)on the keypad  Data Bit set to “8”
Input coordinates of the occupied station (STN)  Press F2 (Vang) to returned 20. Z:20.000 Press (ENT)on the keypad  Stop bit by default “1”
6. N:20000.000 Press (ENT)on the keypad  Press F3 (HD) to set another point to 21. R.HT: if needed Press (ENT) on the keypad  Parity set to “NONE”
7. E:20000.000 Press (ENT)on the keypad measure 22. FOCUS THE TARGET PRISM 13. Click OK to Set
8. Z:20.000 Press (ENT)on the keypad 23. Press F1(MEAS) 14. Click Comm
MLM–
MLM–Missing Line Measurement
9. I.HT: if needed Press (ENT)on the keypad  Press F1 (NEXT) Measure another point
1. Press M
10. Press F2: INPUT BACKSIGHT  Press F4 (CAL) to calculate coordinate of the
2. Press F2:MEAS PROGRAM
 Input point number stored on the keypad 3. Press F2:MLM occupied point.
Press ENT on the keypad to confirm 4. Create Any Filename/Press F4 (JUMP) 24. Press F4 (CAL)
 F2 (LIST) searching Data in the mem 5. Press ENT on the keypad 25. Press F4 (YES)
 F1 Continuous reading from 1st point 26. FINISH…
Press on the keypad (scroll up) 15. Click Download 600 Data
Press  on the keypad (scroll down)  F2 Point to point measurement Confirmation……..
Press ENT on the keypad to confirm 6. Press F1:MLM1(A-B A-C) DOWNLOAD DATA…
11. Press F4 (NEZ) 7. FOCUS THE TARGET PRISM TOTAL STATION SETTINGS
Input coordinates of the backsight point <STEP-1> 1. Press M on the keypad
Press F4 (ANG) use angle to set backsight 8. Press F1 (MEAS) 2. Press F3: MEMORY MGR.
9. Press F4 (SET) 3. Press so  Down arrow 2X 16. Click ENTER on computer then press F4(YES)
12. N:20001.000 Press ENT on the keypad
10. Focus next target/next point 4. Press F1: DATA TRANSFER on Total Station in a second
13. E:20002.000 Press ENT on the keypad
<STEP-2> a) Press F3:COMM. PARAMETERS Ex. Data download output
Calculated Angle will display
14. Focus the target PRISM 11. Press F1 (MEAS) b) Press F1:BAUD RATE = 9600b/s
15. Press F4 [YES] Set reference angle 12. Press F4 (SET)  Press F3 (-)
16. Press F3: LAYOUT 13. Display (HR,dHD,dVD,dSD)  Press F4 (+) add
 Input point number stored in the memory 14. Press F4 (NEXT)/measure next point c) Press ENT on the keypad to confirm
Press ENT on the keypad to confirm d) Press F2:CHAR CHECKOUT
AREA–
AREA–Calculate the Area  Press F3: 8 BIT NONE
 F2 (LIST) searching Data in the memory SAVE Data in any extension file like CSV,TXT,DXT
Press on the keypad (scroll up) 1. Press M on the keypad  Press ENT on the keypad to confirm 17. CLICK FILE SELECT SAVE AS
2. Press F2: MEAS PROGRAM e) Press F3:PROTOCOL 18. FILENAME.csv then click SAVE
Press  on the keypad (scroll down)
3. Press F3:AREA  Press F2: NO ACK
Press ENT on the keypad to confirm 5 6
Press F4 (YES)  F1:FILE DATA /Calculate the Area using File in the  Press ENT on the keypad to confirm
17. Press F4 (NEZ) internal memory F) Press ESC on the keypad to exit Parameters
Input coordinates of the point to Layout  F2:MEASURE/ Calculate the Area using direct settings
18. N :20005.000 Press ENT on the keypad
measuring 4 5. Press F1: SEND DATA
4. Press F2:MEASURE 6. Press F2: COORDINATE DATA
19. E :20004.000 Press ENT on the keypad 5. FOCUS THE TARGET PRISM 7. Press F2 (LIST)
20. Z :19.000 Press ENT on the keypad 6. Press F1 (MEAS)
3Press ENT on the keypad 8. Use  on the keypad to select file.
21. R.HT:1.3____ 7. Press F4 (YES)
22. Display Calculated Angle and Distance Ex.SURVEYTECH
8. Focus the prism… Do the same (5 and 6)
23. Press F4 (NEXT) 9. Press ENT on the keypad to confirm selected file.
9. Calculated Area displayed as follows…
24. Rotate the instrument to get dHR
dHR=0°00'00" (location point)
Ex. S = 203.222 m²
RESECTION
 STANDBY……OPEN SOUTH SOFTWARE
25. Press F2 (DIST) 10. Double Click the South Downloadingsoftware
1. Press M on the keypad
dHD: must set to zero”0” 11. Click Comm
2. Press F2:MEAS PROGRAM
Ex. dHD: 80.123 m 3. Press so  down arrow on the keypad
dHD: 0.000 m (location point) 4. Press F4:RESECTION
26. F1 (MEAS) change the instrument reading 5. Create Any filename
27. F2 (ANG) to checked the angle 6. Press ENT on the keypad