You are on page 1of 36

Network Engineering Training Session on

Flexi 1GB Baseband Step by Step


Part 4: HSUPA allocation, dimensioning & licensing
CS Voice dimensioning
Multi RAB dimensioning (HSPA + AMR call)

19.09.2012
Bartosz Wrbel
Network Engineering

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

General Information

This slide set shall not be considered as an official feature description nor HSPA
performance document. All references to those details in this document are for
your convenience only and shall be double-checked from respective customer
documents before any quotations.
This document is not a RAN Dimensioning Guide. All capacity values
and performance figures in this document shall be verified from WCDMA
RAN documentation.

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

Where to find more information about Baseband


Dimensioning ?
RU30 Baseband Dimensioning internal guideline
RAN_Dim Dimensioning tool
FAQ

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

Contents
General Introduction
Technical Details
RU30 Licensing aspects
RU30 Baseband dimensioning rules
Common Control Channels Dimensioning

R99 Dimensioning
Flexi System Module rel.2
Local Cell Grouping
HSDPA Dimensioning
HSDPA BTS Processing Set resources allocation
HSUPA Dimensioning
HSUPA BTS Processing Set resources allocation
CS Voice Over HSPA Dimensioning
Multi RAB dimensioning
Network Parameters

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

Impact of RAN2123 on BTS dimensioning

New licensing
aspects
New licensing aspects
for System Module rel.2

For internal use


Nokia Siemens Networks 2012

RAN2123
1 Gigabit Baseband

New dimensioning
rules
New baseband dimensioning
rules for System Module rel.2

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

Impact of RAN2123 on BTS dimensioning

New licensing
aspects
New licensing aspects
for System Module rel.2
New license for HSPA
New licenses describes HSPA performance (throughput and users)
HSDPA/HSUPA schedulers do not consume CE licenses any more.
Same approach for CE licenses
CE licenses are called now Rel99 CE licenses
R99 users consumes Rel99 CE licenses depending on bearer rate

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

RAN2123
1 Gigabit Baseband

Impact of RAN2123 on BTS dimensioning

New dimensioning
rules

RAN2123
1 Gigabit Baseband

New baseband dimensioning


rules for System Module rel.2
Processing capability of System Module Rel.2 is significantly
increased comparing to RU10/RU20
Common Control Channels dimensioning is similar as in RU10/RU20
Basic configurations (e.g. 3cells/20km or 6cells/10km) are supported with baseband
resources included in System Module Rel.2 capacity
48 Rel99 CE licenses are required per each step

R99 dimensioning same as in RU20 On Top


HSPA dimensioning approach change
New baseband dimensioning rules, HSPA thr., number of users improvement

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA Dimensioning

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HW in RU30 Flexi WCDMA BTS (1/2)


System Module Rel.2 capacity HSUPA activated

HSUPA activation does not consume any baseband resources*.


However for HSUPA users and throughput processing baseband resources (subunits) needs to
be allocated based on current traffic need.
HSUPA baseband resources allocation is performed in steps so called HSUPA resource
steps. One step is equal to of System Module rel.2 subunit.
HSUPA baseband capacity reservation is based on HSUPA license (HSUPA BTS processing
sets)
In case if R99 CE licensed baseband resources are overlapping HSUPA licensed baseband
resources overlapped resources can be dynamically exchanged between R99 and HSUPA
users
One HSUPA BTS processing set license corresponds to 6 HSUPA resource steps (1,5 subunit)
(RU30EP1/EP2)
One HSUPA processing set does not correspond to 1 Subunit (RU30EP2) (see details on
further slides)

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HW in RU30 Flexi WCDMA BTS (2/2)


Interference cancellation units

10

In case when Interference Cancellation feature is activated, Interference Cancellation units


(PIC pool) needs to be commissioned in order to perform interference cancellation for
mapped HSPA cells.
One PIC pool requires one subunit. Number of PIC pool is commissioned by operator
One PIC supports up to 6 cells (interference cancellation can be done simultaneously in 3
selected by BTS cells)

Cells from one frequency layer should be mapped to one PIC pool
One PIC pool supports up to 2 frequency layers
Note that HSUPA scheduler cooperates only with PIC pools located in the same System
Module
With 4 way Rx diversity feature single PIC pool supports up to 3 cells (interference
cancellation can be done simultaneously in 1 cell selected by BTS)

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA baseband resources allocation in RU30


HSUPA Processing Set in RU30EP1 and RU30EP2

HSUPA license is called HSUPA BTS Processing Set

The HSUPA BTS Processing Set is a HSUPA BB resources reservation inside the Flexi System Module
Rel.2, that allows for a certain number of HSUPA users and HSUPA throughput.

HSUPA baseband resources allocation is performed in steps so called HSUPA resource steps. One
step is equal to of subunit.
Users/throughput

HSUPA licensed
Unlicensed BB
capacity
capacity

HSUPA BTS
Processing set

11

HSUPA
HSUPA
thr.,
licensed
users
capacity

HSUPA
HSUPA
thr.,
licensed
users
capacity

HSDPA thr.,
users, HSDPA
cells

HSUPA BTS
Processing set licenses

1 HSUPA Processing Set corresponds to 1,5 subunit

1 HSUPA Processing Set allows to reach 5.8Mbps or 24 users

For internal use


Nokia Siemens Networks 2012

HSDPA thr.,
users, HSDPA
cells

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA baseband resources allocation in RU30


SRB processing
In RU30 with System Module rel.2 HSUPA does not consume any Rel99 CE licenses

UL

DL

SRB
(1CE UL)
SRB
(1CE DL)

No-FDPCH capable
UE or
F-DPCH capable UE
(rel.7) but F-DPCH
feature not activated

HSUPA
Scheduler
(subunits)

UL

DL

FDPCH capable UE
(rel.7) and F-DPCH
feature activated

HSUPA
Scheduler
(subunits)

Less baseband resources needed for HSUPA


Rel99 CE licenses are not needed for HSUPA

12

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

RU30 brings SRB


processing
improvement (no
additional 1 CE
(UL/DL) for HSUPA
user (UL:HSUPA
bearer, DL:HSDPA
bearer)

HSUPA in RU30 EP1


2 HSUPA schedulers per one LCG

In RU30EP1 with System Module Rel.2, one HSUPA scheduler can support up to 200 HSUPA users
from 1 to 12 cells.

Up to one HSUPA scheduler is allocated per single LCG with single System Module Rel.2

Up to two HSUPA schedulers are allocated per single LCG with two System Modules rel.2 and
frequency layers mapping to HW (note that frequency mapping to HW is possible only in one
LCG scenario (RU30EP1/EP2))
up to 400 HSUPA users supported per LCG (2 x System Module rel.2)
400 HSUPA
users per LCG

LCG1

200 HSUPA
users per
Extension
System Module

f1

f2

200 HSUPA
users per
Master System
Module

13

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA in RU30 EP2


2 HSUPA schedulers per one LCG

In RU30EP2 with System Module Rel.2, one HSUPA scheduler can support up to 240 HSUPA users
from 1 to 12 cells

Up to one HSUPA scheduler is allocated per single LCG with single System Module Rel.2

Up to two HSUPA schedulers are allocated per single LCG with two System Modules rel.2 and
frequency layers mapping to HW (note that frequency mapping to HW is possible only in one
LCG scenario (RU30EP1/EP2))
up to 480 HSUPA users supported per LCG (2 x System Module rel.2)
480 HSUPA
users per LCG

LCG1

240 HSUPA
users per
Extension
System Module

f1

f2

240 HSUPA
users per
Master System
Module

14

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA resources allocation


System Module Rel.2

If licensed R99 and HSUPA baseband resources (allowed with the available HSUPA BTS processing
sets and Rel99 CE licenses) exceeds System Module rel.2 capacity, overlapping baseband resources
can be dynamically exchange between R99 and HSUPA users.

One HSUPA BTS Processing Set license can be utilized by R99 users (48Rel99 CE) even without R99
CE licenses.

Other HSUPA resources can be also dynamic, but only if they are overlapped by Rel99 CE licenses

BB resources
48CE
(dynamic)

HSUPA BTS
Processing sets

Can be utilized by R99 users

15

For internal use


Nokia Siemens Networks 2012

BB resources
48CE
(dynamic)

Rel99 CE licenses
HSUPA BTS
HSUPA BTS
Processing
set
Processing set

Can be utilized by R99 users

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

BaseBand resources allocation


Non- Overlapping baseband resources
License non- overlapping case
One HSUPA BTS Processing Set (equivalent
of 48 R99 CE) is always available for R99
users and HSUPA users*
System Module Rel.2

Rel99 CE licenses

HSUPA BTS
processing
sets

Baseband resources available


for R99 users

16

For internal use


Nokia Siemens Networks 2012

HSDPA
commissioned
throughput

Free (unlicensed) baseband


resources not available for
R99 users and HSPA data
users

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

* Note: 48 CE in each
LCG is always
dynamic (even without
license overlapping)

BaseBand resources allocation


Overlapping baseband capacity and static resources reservation
Overlapping scenario
System Module Rel.2

Rel99 CE licenses

HSUPA BTS
processing
sets

HSDPA
commissioned
throughput

Baseband resources available for HSUPA users


only!
Rel 99 users

48CE
(dynamic)

HSUPA users

HSUPA BTS
Processing sets

* R99 users have always higher priority

Overlapping baseband capacity can be


dynamically share between HSUPA users and
R99 user*

For overlapping Rel99 CE licenses and licensed HSUPA resources, commissioning can be performed in
order to guarantee resources for HSUPA.
NOTE: Up to four HSUPA resource steps can be statically commissioned for HSUPA
17

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA resources allocation (1/2)

HSUPA scheduler supports different types of HSUPA users (2msTTI/10ms TTI, F-DPCH/no-FDPCH, CS
Voice over HSPA users)
Each type of HSUPA user has different baseband requirements
Required Baseband resources for HSUPA scheduler depends on number of CS Voice over HSPA and
HSUPA active users and combined L1 throughput
For HSUPA scheduler baseband resources dimensioning purpose few different tables according to the
user types should be used
In addition for HSUPA users transmitting with 16QAM (F-DPCH or no-FDPCH) additional rule should be
applied. One subunit is required for single 16QAM transmitting user
CS Voice over HSPA users consume Subunits. Max 18 CS Voice over HSPA users are allocated in single
Subunit

10ms TTI no-FDPCH dimensioning table


10ms TTI FDPCH dimensioning table
2ms TTI FDPCH dimensioning table
2ms TTI no-FDPCH dimensioning table
#CS Voice over HSPA users

HSUPA scheduler baseband


resources for CS Voice over HSPA
and HSUPA data users

# of 16QAM transmitting UE (RU30EP2)

18

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA resources allocation (2/2)


HSUPA requirements for simultaneous users and throughput
2ms TTI FDPCH
dimensioning table

10ms TTI FDPCH


dimensioning table

10ms TTI
FDPCH
UEs

2ms TTI
FDPCH UEs

2ms TTI no-FDPCH UEs

10ms TTI noFDPCH UEs

HSUPA scheduler
baseband resources for
HSUPA data and CS Voice
over HSPA users

16QAM 2ms
TTI (FDPCH
/ no-FDPCH
UEs)

2ms TTI noFDPCH UEs


CS Voice
over HSPA

1 Subunit for 18 CS
Voice over HSPA users
19

For internal use


Nokia Siemens Networks 2012

10ms TTI no-FDPCH


dimensioning table

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

1 Subunit for single


16QAM transmitting UE

HSUPA subunits for 2ms TTI UEs


FDPCH feature not activated or no-FDPCH capable UEs (SRB on DCH)
2ms TTI noFDPCH UEs

Table presents required number of subunits for HSUPA 2ms TTI no-FDPCH UEs

HSUPA subunits for 2ms TTI UE in RU30 EP1 (without 16QAM)


Number of
HSUPA
<1.0
1.0
2.9
4.3
5.8
7.2
8.7
10.1 11.6 13.0 14.5 15.9 17.4 18.8 20.3 21.7 23.2 24.6 26.1 27.5 29.0 30.4 31.9 33.3 34.8 36.2 37.6 39.1 40.6 42.0 43.4 44.9 46.4 47.8 49.2 50.7 52.2 53.6 55.0 56.5
58
UEs
Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps
per
scheduler
1
0,25
0,5
0,75 0,75 0,75 N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2

0,25

0,5

0,75

0,75

1,75

1,75

1,75

1,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

3~4

0,25

0,5

1,5

1,5

1,75

1,75

1,75

1,75

2,75

2,75

2,75

3,75

3,75

3,75

3,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

5~6

0,5

0,75

1,5

1,5

1,75

1,75

2,75

2,75

2,75

3,75

3,75

3,75

3,75

4,75

4,75

4,75

5,25

5,75

5,75

5,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

7~8

0,5

0,75

1,5

1,5

1,5

1,75

2,75

2,75

2,75

3,75

3,75

3,75

3,75

4,75

4,75

4,75

5,25

5,75

5,75

5,75

7,75

7,75

7,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

9~10

0,75

1,5

1,75

2,25

2,25

2,25

2,75

2,75

3,75

3,75

3,75

3,75

4,5

5,5

6,5

6,5

6,5

7,75

8,5

9,75

9,75

9,75

9,75

11~12

0,75

1,75

1,75

2,25

2,5

2,5

2,75

2,75

3,75

3,75

3,75

4,5

4,5

5,5

6,5

6,5

6,5

8,25

8,25

8,75

9,75

9,75

10

10

13~14

1,75

1,75

2,25

2,5

2,5

2,75

2,75

3,75

3,75

3,75

4,5

4,75

5,25

5,25

5,25

5,5

6,5

6,5

6,5

8,25

8,25

8,75

9,75

9,75

10

10

15~16

2,25

2,5

2,5

2,75

2,75

2,75

3,75

3,75

3,75

4,5

4,75

5,25

5,25

5,25

5,5

6,5

6,75

6,75

8,25

8,25

8,75

9,25

9,25

9,25

9,75

9,75

10

10

17~18

1,25

2,25

2,5

2,5

2,75

2,75

3,25

3,5

4,75

4,75

4,75

5,25

5,25

5,75

6,25

6,25

6,25

6,5

6,75

6,75

8,25

8,25

8,75

9,25

9,25

9,25

9,75

9,75

10

10

19~20

1,25

1,25

2,25

2,5

2,5

2,75

2,75

3,25

3,75

4,25

4,25

4,25

4,75

4,75

4,75

5,25

5,75

5,75

6,25

6,75

6,75

6,75

6,75

7,75

7,75

7,75

8,25

8,75

8,75

8,75

8,75

9,25

9,25

9,25

9,75

9,75

10

10

21~22

1,25

1,25

2,25

2,5

2,5

2,75

2,75

3,25

3,75

4,25

4,25

4,25

4,75

4,75

4,75

5,25

5,75

5,75

6,25

6,75

6,75

6,75

6,75

7,75

7,75

7,75

8,25

8,75

8,75

8,75

8,75

9,25

9,25

9,25

10

10

11

23~24

1,5

1,5

2,5

2,5

2,5

2,75

3,25

3,75

4,25

4,25

4,5

4,75

4,75

4,75

5,25

5,75

5,75

6,25

6,75

6,75

6,75

6,75

7,75

7,75

8,25

8,25

8,75

8,75

8,75

8,75

9,25

9,25

9,25

10

10

10

11

11

25~26

1,5

1,5

2,5

2,5

2,5

2,75

3,25

3,75

4,25

4,5

4,5

4,75

4,75

4,75

5,25

5,75

6,25

6,75

6,75

6,75

6,75

6,75

7,75

7,75

8,25

8,25

8,75

8,75

8,75

8,75

9,25

9,25

10

10

10

10

11

11,25

27~28

1,5

1,5

2,5

2,5

2,5

2,75

3,75

3,75

3,75

3,75

4,25

4,5

4,5

4,75

4,75

4,75

5,25

5,75

6,25

6,75

6,75

6,75

6,75

7,5

7,75

8,25

8,25

8,25

8,75

8,75

8,75

8,75

9,25

9,25

10

10

10

10

11

11,25

29~30

1,5

1,5

2,5

2,5

2,5

3,25

3,75

3,75

3,75

3,75

4,25

4,5

4,5

4,75

4,75

4,75

5,25

5,75

6,25

6,75

6,75

6,75

6,75

7,5

7,75

8,25

8,75

8,75

8,75

8,75

8,75

8,75

9,25

10

10

10

10

10

11

11,25

31~32

1,75

1,75

2,5

3,75

3,75

3,75

3,75

4,25

4,25

4,5

4,5

5,25

5,75

6,25

6,75

6,75

6,75

6,75

7,5

7,75

8,25

8,75

8,75

9,25

9,25

9,25

10

10

10

10

10

11

11,25

33~34

2,5

3,5

3,5

3,75

3,75

3,75

4,25

4,25

4,25

4,75

5,25

5,75

6,25

6,75

6,75

6,75

6,75

7,5

7,75

8,25

8,75

8,75

9,25

9,25

9,25

10

10

10

10

10

11

11,25

35~36

2,75

3,5

3,5

3,75

4,25

4,25

4,75

4,75

5,25

5,25

5,75

5,75

6,25

6,25

6,75

7,25

7,25

7,25

7,5

7,75

8,25

8,75

8,75

9,25

9,25

9,25

9,75

10

10

10

10

10

11

11,25

37~38

2,25

2,25

2,75

3,5

3,5

3,75

4,25

4,25

4,75

4,75

5,25

5,25

5,75

5,75

6,25

6,25

6,75

7,25

7,25

7,25

7,75

8,25

8,25

8,75

8,75

9,25

9,25

9,25

9,75

10

10

10

10

10

11

11,25

39~40

2,25

2,25

2,75

3,5

3,5

4,25

4,25

4,75

5,25

5,25

5,25

5,25

5,75

5,75

6,25

6,75

7,25

7,25

7,25

7,75

7,75

8,25

8,25

8,75

8,75

9,25

9,25

9,75

9,75

10,5

11

11

11

11

11

11,25

41~44

2,5

2,5

4,25

4,25

4,75

5,25

5,25

5,25

5,25

5,75

6,25

6,25

6,75

7,25

7,25

7,25

7,75

8,25

8,25

8,75

8,75

9,25

9,25

9,75

10

10,5

11

11

11

11,25 11,75 12,25

11

11

11,25 11,75 12,25

45~48

2,5

3,5

4,5

4,5

4,75

5,25

5,25

5,75

5,75

5,75

5,75

6,25

6,25

6,75

7,25

7,25

7,25

7,75

8,25

8,75

8,75

9,25

9,25

9,75

9,75

9,75

10,5 10,75

11

49~52

3,5

3,5

4,5

4,5

4,5

4,5

4,5

4,75

5,25

5,25

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,75

7,75

7,75

8,25

8,75

8,75

9,25

9,25

9,75

9,75

9,75

10,5

11

11

11,25 11,25 11,25 11,75 12,25

53~56

3,25

3,25

4,5

4,5

4,5

4,5

4,5

5,25

5,75

5,75

5,75

5,75

6,25

6,75

6,75

7,25

7,25

7,75

7,75

8,25

8,75

8,75

9,25

9,75

9,75 10,25 10,25 10,75 10,75 10,75

11

11

11,75 11,75 11,75 11,75 12,25

57~60

3,5

3,5

4,5

4,5

4,5

4,75

4,75

4,75

5,25

5,75

5,75

5,75

5,75

6,25

6,75

6,75

7,25

7,25

7,75

7,75

8,25

8,75

8,75

9,25

9,75 10,25 10,25 10,25 10,75 10,75 10,75 11,25 11,25 11,75 11,75 11,75 12,25 12,25

61~64

3,5

3,5

4,5

4,5

5,5

5,5

5,5

6,25

6,5

6,75

6,75

7,25

7,25

7,75

8,25

8,25

8,75

8,75

9,25

9,75 10,25 10,25 10,25 10,25 10,75 11,25 11,25 11,25 11,75 11,75 11,75 11,75 12,25 12,25

65~68

3,75

3,75

4,75

5,5

5,5

5,5

6,25

6,5

6,75

6,75

6,75

6,75

6,75

7,75

8,25

8,25

8,75

9,25

9,25

9,75

9,75

9,75 10,25 10,25 10,25 10,25 10,75 11,25 11,25 11,25 11,75 11,75 11,75 11,75 12,25 12,25

69~72

4,75

5,5

5,5

5,5

6,5

6,5

7,5

7,5

7,75

7,75

8,25

8,75

8,75

9,25

9,25

9,75

9,75

9,75 10,25 10,25 10,25 10,75 10,75 11,25 11,25 11,25 11,75 11,75 11,75 11,75 12,25 12,25

73~76

4,25

4,25

4,5

5,5

5,5

5,5

6,5

6,5

7,5

7,5

7,5

7,75

7,75

8,25

8,75

9,25

9,25

9,75

9,75

9,75

9,75 10,25 10,25 10,25 10,75 10,75 11,25 11,25 11,75 12,75 12,75 12,75 12,75 13,25 13,75

77~80

4,5

4,5

4,5

5,5

5,5

5,5

6,5

6,5

7,5

7,5

7,5

7,75

7,75

8,25

8,75

9,25

9,75

9,75

9,75

9,75

9,75 10,25 10,25 10,25 10,75

81~100

5,5

5,5

5,5

5,5

6,5

7,5

8,5

8,75

8,75

9,25

9,25

9,75

9,75

9,75 10,25 10,25 10,75 11,25 11,25 11,25 11,75 11,75 11,75 11,75 12,75 12,75 12,75 13,75 13,75 14,25 14,75 14,75

6,5

6,5

6,5

6,5

7,5

7,5

8,5

8,5

8,5

9,75

9,75

9,75 10,25 10,75 10,75 11,25 11,25 11,75 11,75 12,25 12,75 12,75 13,25 13,25 13,25 13,75 13,75 13,75 13,75 13,75 14,25 14,75 14,75

10

10

10,5

10,5

10,5

10,5

101~120
121~160

2,5

11

160~200

11,25 11,25 11,25 11,25 11,25 11,25 11,25 11,25 11,75 11,75 11,75

201~240

13,5

13,5

13,5

13,5

13,5

13,5

13,5

13,5

14

14

14,5

12
14,5

9,25

11

11

11

11

11,25 11,75 11,75 11,75

15

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

15

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

14,5

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

15

15

15

15

N/A

N/A

N/A

12,75 12,75 12,75 13,25 13,25 13,75 13,75 14,25 14,25 14,75 14,75
N/A

N/A

Note: figures are tentative and will be confirmed after final verification in pilot phase
20

For internal use


Nokia Siemens Networks 2012

11,25 11,75 11,75 12,75 12,75 12,75 12,75 13,25 13,75

12,75 12,75 12,75 13,25 13,75 14,25 14,25 14,25 14,75 14,75 14,75
14,5

12

11

Table assumes typical use case when the majority of the users are downlink data dominated
and the remaining users are UL data dominated.
MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA subunits for 2ms TTI UEs


FDPCH feature activated and FDPCH capable UEs (SRB on HSPA)
2ms TTI
FDPCH UEs

Table presents required number of subunits for HSUPA 2ms TTI FDPCH UEs

HSUPA subunits for 2ms TTI UE in RU30 EP1 (without 16QAM)


Number of
HSUPA UEs <1.0
1.0
2.9
4.3
5.8
7.2
8.7
10.1 11.6 13.0 14.5 15.9 17.4 18.8 20.3 21.7 23.2 24.6 26.1 27.5 29.0 30.4 31.9 33.3 34.8 36.2 37.6 39.1 40.6 42.0 43.4 44.9 46.4 47.8 49.2 50.7 52.2 53.6 55.0 56.5
58
per
Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps
scheduler
1
0,25
0,5
0,75 0,75 0,75 N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
2

0,25

0,5

0,75

0,75

0,75

1,75

1,75

1,75

1,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

3~4

0,25

0,5

0,75

0,75

1,75

1,75

1,75

1,75

2,5

2,5

3,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

5~6

0,25

0,75

1,5

1,5

1,75

1,75

1,75

2,5

2,5

2,5

3,75

4,5

4,5

5,5

5,75

5,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

7~8

0,25

0,75

1,5

1,5

1,75

1,75

1,75

2,5

2,5

2,5

3,25

3,75

4,5

4,5

5,5

5,75

5,75

6,5

7,75

7,75

N/A

N/A

N/A

N/A

N/A

N/A

N/A

N/A

9~10

0,25

0,75

1,5

1,5

1,5

1,75

1,75

1,75

2,75

2,75

2,75

3,25

3,75

4,5

4,5

5,5

5,5

5,75

6,5

6,5

6,5

7,5

7,75

7,75

9,75

9,75

11~12

0,5

0,75

1,5

1,5

1,5

1,75

2,5

2,75

2,75

2,75

3,25

3,25

3,25

3,25

4,5

4,5

5,5

5,5

6,5

6,5

6,5

7,5

7,75

9,5

10

10

13~14

0,5

0,75

1,5

1,5

1,5

1,75

2,5

2,5

2,5

2,75

2,75

2,75

3,25

3,25

3,25

3,25

4,5

4,5

5,5

5,5

6,5

6,5

6,5

7,5

7,75

9,5

10

10

15~16

0,5

0,75

1,5

1,5

1,5

2,5

2,5

2,75

2,75

2,75

3,25

3,25

3,25

3,25

3,25

4,5

4,5

5,5

6,5

6,5

6,5

7,5

7,75

9,5

10

10

17~18

0,5

0,75

1,5

1,5

1,5

2,5

2,5

2,5

2,75

2,75

3,25

3,25

3,25

3,75

3,75

4,75

4,75

4,75

5,5

6,5

6,5

6,5

7,5

7,5

7,75

9,5

10

10

19~20

0,5

0,75

1,5

2,5

2,5

2,5

2,75

2,75

3,25

3,25

3,25

3,75

4,75

4,75

4,75

5,5

6,75

7,5

7,5

7,75

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25

21~22

0,75

0,75

1,5

2,5

2,5

2,75

3,25

3,25

3,25

3,25

3,75

4,75

4,75

4,75

5,25

5,25

5,75

6,25

6,25

6,75

7,5

7,5

7,75

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25

23~24

0,75

0,75

1,5

2,5

2,5

2,75

3,25

3,25

3,25

3,25

3,75

4,75

4,75

4,75

5,25

5,25

5,75

6,25

6,25

6,75

7,5

7,5

7,75

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25

25~26

0,75

0,75

1,5

2,5

2,75

3,25

3,25

3,25

3,25

4,75

4,75

4,75

5,25

5,25

5,75

6,25

6,25

6,25

6,75

7,5

7,5

7,75

8,25

8,75

9,75

9,75

9,75

9,75

9,75

10,25 10,25

27~28

0,75

1,5

2,25

2,5

2,75

3,25

3,25

3,25

4,75

4,75

4,75

4,75

4,75

5,25

5,25

5,75

6,25

6,25

6,25

6,75

7,5

7,5

7,75

8,25

8,75

9,75

9,75

9,75

9,75

9,75

10,25 10,25

29~30

0,75

1,5

2,25

2,5

2,75

3,5

3,5

4,75

4,75

4,75

4,75

5,25

5,25

5,75

5,75

6,25

6,25

6,75

6,75

7,5

7,5

7,75

8,25

8,75

9,75

9,75

9,75

9,75

9,75

10,25 10,25

31~32

1,5

2,25

2,75

3,5

3,5

4,75

4,75

4,75

5,25

5,25

5,25

5,75

5,75

6,25

6,25

6,75

6,75

7,5

7,5

7,75

8,25

8,75

9,75

9,75

9,75

9,75

9,75

10,25 10,25

33~34

1,5

2,25

2,75

3,5

3,5

4,75

4,75

4,75

4,75

5,25

5,25

5,25

5,75

5,75

6,25

6,25

6,75

6,75

7,5

7,5

7,5

7,75

8,25

8,25

8,75

9,75

9,75

9,75

9,75

9,75

10,25 10,25

35~36

1,5

2,25

2,75

3,25

3,25

3,75

3,75

4,75

4,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,25

7,5

7,5

7,75

8,25

8,25

8,75

9,75

9,75

9,75

9,75

9,75

10,25 10,25

37~38

1,5

2,25

2,75

3,25

3,75

3,75

3,75

4,75

4,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

9,75

9,75

9,75

10,25 10,25

39~40

1,5

2,25

2,75

3,25

3,75

3,75

3,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25 10,75 10,75

41~44

1,25

1,5

1,75

2,25

2,75

3,25

3,75

3,75

3,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25 10,75 10,75

45~48

1,25

1,5

1,75

2,25

2,75

3,25

3,75

3,75

3,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25 10,75 10,75

49~52

1,5

1,75

2,25

2,75

3,25

3,75

3,75

3,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25 10,75 10,75

53~56

1,5

1,75

2,25

2,75

3,5

3,75

3,75

3,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,25

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25 10,75 10,75

57~60

1,5

1,75

2,25

2,75

3,5

3,75

3,75

3,75

4,75

4,75

4,75

5,75

5,75

5,75

6,25

6,25

6,75

6,75

7,75

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

9,75

10,25 10,25 10,75 10,75

61~64

1,75

1,75

2,25

3,5

4,5

5,5

5,5

5,5

5,75

5,75

5,75

6,25

6,75

6,75

7,25

7,75

7,75

7,75

7,75

8,25

8,25

8,25

8,75

9,75

9,75

10,25 10,25 10,25 10,75 10,75 10,75 10,75

65~68

1,75

1,75

3,5

3,5

4,5

4,5

4,5

5,5

5,5

5,5

5,75

5,75

5,75

6,25

6,75

6,75

7,25

7,75

7,75

7,75

7,75

8,25

8,25

9,25

9,25

9,75

9,75

10,25 10,25 10,75 10,75 10,75 10,75 10,75

69~72

3,5

3,5

4,5

4,5

4,5

4,5

5,5

5,5

5,5

6,25

6,25

6,75

6,75

7,25

7,75

7,75

8,25

8,25

8,25

8,75

9,25

9,25

9,75

9,75

10,25 10,25 10,75 10,75 10,75 10,75 10,75

73~76

3,5

4,5

4,5

4,5

4,5

5,5

5,5

5,5

6,25

6,75

6,75

6,75

7,25

7,75

7,75

8,25

8,25

8,75

8,75

9,25

9,25

9,75

9,75

10,25 10,75 10,75 10,75 10,75 10,75 10,75

77~80

3,5

4,5

4,5

5,5

5,5

6,75

6,75

6,75

6,75

7,25

7,25

7,75

7,75

8,75

8,75

8,75

9,25

9,25

9,75

9,75

9,75

10,25 10,75 10,75 10,75 11,25 11,75 11,75

81~100

2,5

2,5

3,5

5,5

5,5

6,75

6,75

6,75

6,75

6,75

6,75

6,75

7,25

7,25

7,75

7,75

8,75

8,75

8,75

9,25

9,25

9,75

9,75

9,75

10,25 10,75 10,75 10,75 11,25 11,75 11,75

101~120

3,5

6,5

6,75

6,75

7,75

7,75

7,75

8,75

8,75

8,75

8,75

9,75

9,75

9,75

9,75

10,25 10,25 10,25 10,75 10,75 10,75 10,75 11,25 11,75 11,75

121~160

5,5

6,5

7,5

7,5

8,75

8,75

8,75

9,75

9,75

9,75

9,75

10,75 10,75 10,75 10,75 11,75 11,75 11,75 11,75 11,75 11,75 11,75 12,75 12,75

160~200

9,75

9,75

9,75

9,75

10,75 10,75 10,75 10,75 11,75 11,75 11,75 12,75 12,75 12,75 12,75 12,75 12,75 13,75 13,75

201~240

10

10

10

10

10

10

10,75 10,75 10,75 11,75 11,75 11,75 11,75 12,75 12,75 12,75 13,75 13,75 13,75 13,75 13,75 13,75 14,25

Note: figures are tentative and will be confirmed after final verification in pilot phase
21

For internal use


Nokia Siemens Networks 2012

Table assumes typical use case when the majority of the users are downlink data dominated
and the remaining users are UL data dominated.
MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA subunits for 10ms TTI UEs


FDPCH feature activated and FDPCH capable UEs (SRB on HSPA)
10ms TTI
FDPCH UEs

Table presents required number of subunits for HSUPA 10 ms TTI FDPCH UEs

HSUPA subunits for 10ms TTI UE in RU30 EP1


Number of
HSUPA UEs <1.0 1.0
2.0
2.9
4.3
5.8
7.2
8.7 10.1 11.6
13
14.5 15.9 17.4 18.8 20.3 21.7 23.2 24.6 26.1 27.5
29
30.4 31.9 33.3 34.8 36.2 37.6 39.1 40.6
42
43.4 44.9 46.4 47.8 49.2 50.7 52.2 53.6
55
56.5
58
per
Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps
scheduler
1
0,25 0,5 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
2
3~4
5~6
7~8
9~10
11~12
13~14
15~16
17~18
19~20
21~22
23~24
25~26
27~28
29~30
31~32
33~34
35~36
37~38
39~40
41~44
45~48
49~52
53~56
57~60
61~64
65~68
69~72
73~76
77~80
81~100
101~120
121~160
160~200
201~240

0,25
0,25
0,25
0,25
0,25
0,5
0,5
0,5
0,5
0,5
0,75
0,75
0,75
0,75
0,75
1
1
1
1
1
1,25
1,25
1,5
1,5
1,5
1,75
1,75
2
2
2
2,5
3
4
5
6

0,5
0,5
0,5
0,5
0,75
0,75
0,75
0,75
0,75
0,75
0,75
1
1
1
1
1
1
1
1
1
1,5
1,5
1,75
1,75
1,75
2
2
2
2
2
2,75
3
4
5
6

0,5
0,5
0,75
0,75
1
1
1
1
1
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
2
2
2
2
2
2
2
2
2
2
3
3
4
5
6

0,5
0,5
0,75
0,75
1
1
1
1
1,5
1,5
1,5
1,5
1,5
1,5
1,75
1,75
1,75
1,75
1,75
1,75
2
2
2
2
2
2
2
2
2
2
3
3
4
5
6

N/A
0,75
0,75
1
1
1
1,5
1,5
1,5
1,5
1,5
1,5
1,75
1,75
1,75
2
2
2
2
2
2,5
2,5
2,5
2,5
2,5
3
3
3
3
3
3
3
4
5
6

N/A
1
1
1
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,75
1,75
2
2
2
2
2
2,5
2,5
2,5
2,5
2,5
2,5
3
3
3
3
3
3,5
4
4
5
6

N/A
N/A
1,5
1,5
1,5
1,75
1,75
2
2
2
2
2
2
2
2
2,5
2,5
2,5
2,5
2,5
2,5
3
3
3
3
3
3
3
3,5
3,5
4
4
5
5
6

N/A N/A N/A N/A N/A N/A


N/A N/A N/A N/A N/A N/A
1,5 N/A N/A N/A N/A N/A
1,5
2
2
N/A N/A N/A
1,5
2
2
2,5 2,5 N/A
2
2
2
2,5 2,5
3
2
2
2
2,5 2,5
3
2
2
2
2,5 2,5
3
2
2
2
2,5 2,5
3
2
2
2
2,5 2,5
3
2
2
2,5 2,5
3
3
2
2
2,5
3
3
3
2
2
2,5
3
3
3
2
2,5 2,5
3
3
3
2,5 2,5 2,5
3
3
3
2,5
3
3
3
3
3
2,5
3
3
3
3
3
2,5
3
3
3
3
3,5
2,5
3
3
3
3,5 3,5
2,5
3
3
3
3,5 3,5
3
3
3
3
3,5 3,5
3
3
3
3
3,5 3,5
3
3
3
3,5 3,5
4
3
3
3,5 3,5 3,5
4
3
3,5 3,5 3,5
4
4
3,5 3,5 3,5 3,5
4
4
3,5 3,5 3,5 3,5
4
4
3,5 3,5
4
4
4
4
3,5 3,5
4
4
4
4,5
3,5 3,5
4
4
4
4,5
4
4
4
4
4,5 4,5
4
4,5 4,5
5
5
5
5
5
6
6
6
6
6
6
6
7
7
7
6
7
7
7
7,5 7,5

N/A
N/A
N/A
N/A
N/A
3
3
3
3
3
3
3
3
3
3
3
3,5
3,5
3,5
3,5
4
4
4
4
4
4
4,5
4,5
4,5
4,5
4,5
5,5
6
7
8

N/A
N/A
N/A
N/A
N/A
N/A
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
3,5
4
4
4
4
4
4,5
4,5
4,5
4,5
4,5
4,5
5,5
6,5
7
8

N/A
N/A
N/A
N/A
N/A
N/A
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4,5
4,5
4,5
4,5
4,5
5
5
5
5,5
6,5
7,5
8

N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4,5
4,5
4,5
5
5
5
5
5
5
5,5
6,5
7,5
8

N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4,5
4,5
4,5
5
5
5
5
5
5
5,5
7
8
8,5

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
5
5
6
6
6
6
6
6
6
7
8
8,5

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
4
5
5
5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
7
8
9

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
4
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
7,5
8
9

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
7,5
8,5
9

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
7
7,5
8,5
9,5

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5
5
5
5
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
8
8,5
9,5

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
8
9
10

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7,5
7,5
8
9
10

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
6
6
6
6
6
6
6
6
6
6
6
6
6
7
7
7
7
7
7,5
7,5
8
9
10

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
6
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
8
8
8
9,5
10

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
8
8
9
10
11

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
8
8
9
10
11

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7
7
7
7
7
7
7
7
7
7
7
7,5
7,5
7,5
7,5
8
8
8
9
10
11

Note: figures are tentative and will be confirmed after final verification in pilot phase
22

For internal use


Nokia Siemens Networks 2012

Table assumes typical use case when the majority of the users are downlink data dominated
and the remaining users are UL data dominated.
MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8
8
8
8
8
8
8
8
9
9
11
11

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7,5
7,5
7,5
7,5
7,5
8
8
8
8
8
8
8
8
8
8
9
9
10
11
11

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
10
11
11

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8
8
8
8
8
8
8
8
8
8
8
8
8
8
9
9
10
11
12

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8
8
8
8
8
8
8
8
8
9
9
9
9
9
10
10
10
11
12

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8
8
8
8
8
8
8
8
9
9
9
9
9
10
10
11
11
12

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8
8
8
9
9
9
9
9
9
9
9
9
9
10
10
11
12
12

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8
8
9
9
9
9
9
9
9
9
9
9
10
10
11
12
13

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8
8
9
9
9
9
9
9
9
9
9
10
10
10
11
12
13

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
9
9
9
9
9
9
9
9
9
9
10
10
10
11
12
13

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
9
9
9
9
9
9
9
9
9
9
10
10
10
11
12
13

HSUPA subunits for 10ms TTI UEs


FDPCH not feature activated or no-FDPCH capable UEs (SRB on DCH)
10ms TTI noFDPCH UEs

Table presents required number of subunits for HSUPA 10 ms TTI no-FDPCH UEs

HSUPA subunits for 10ms TTI UE in RU30 EP1


Number of
HSUPA UEs <1.0 1.0
2.0
2.9
4.3
5.8
7.2
8.7
per
Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps
scheduler
1
0,25 0,5 0,5 N/A N/A N/A N/A N/A
2
0,25 0,5 0,5 0,75 N/A N/A N/A N/A
3~4
5~6
7~8
9~10
11~12
13~14
15~16
17~18
19~20
21~22
23~24
25~26
27~28
29~30
31~32
33~34
35~36
37~38
39~40
41~44
45~48
49~52
53~56
57~60
61~64
65~68
69~72
73~76
77~80
81~100
101~120
121~160
160~200
201~240

23

10.1 11.6
13
14.5 15.9 17.4 18.8 20.3 21.7 23.2 24.6 26.1 27.5
29
30.4 31.9 33.3 34.8 36.2 37.6 39.1 40.6
42
43.4 44.9 46.4 47.8 49.2 50.7 52.2 53.6
55
56.5
58
Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps Mbps

N/A
N/A
0,25 0,5 0,75 0,75 1
1
1,5 N/A N/A
0,5 0,75 0,75 0,75 1
1,5 1,5 1,75 2
0,5 0,75 1
1
1,5 1,75 1,75 2
2
0,75 1
1
1 1,75 1,75 1,75 2
2
0,75 1
1,5 1,5 1,75 1,75 2
2 2,75
1
1,5 1,5 1,5 1,75 2
2 2,75 2,75
1
1,5 1,5 1,5 1,75 2
2 2,75 2,75
1
1,5 1,5 1,5 1,75 2 2,75 2,75 2,75
1,25 1,5 1,75 1,75 1,75 2,75 2,75 2,75 3
1,5 1,5 1,75 1,75 2 2,75 2,75 2,75 3
1,5 1,75 1,75 2
2 2,75 2,75 2,75 3
1,5
2
2
2
2 2,75 2,75 2,75 3
1,75 2
2,5 2,5 2,5 2,75 2,75 2,75 3
1,75 2
2,5 2,5 2,5 2,75 3
3
3
2
2
2,5 2,5 2,5
3
3
3
3,5
2
2
2,5 2,5 2,5
3
3,5 3,5 3,5
2
2
2,5 2,5 2,5
3
3,5 3,5 3,5
2,25 2,5 2,75 2,75 3
3
3,5 3,5 3,5
2,5 2,5 2,75 2,75 3
3
3,5 3,5 3,5
2,5 2,5
3
3
3 3,75 3,75 4
4
2,75 2,75 3,5 3,5 3,75 3,75 4
4 4,75
3
3
3,5 3,5 3,75 4
4,5 4,5
5
3,25 3,25 3,75 3,75 4
4
4,5 4,5
5
3,5 3,5 3,75 4
4
4
4,5 4,5
5
3,75 3,75 4
4 4,75 4,75 5
5
5
3,75 3,75 4,5 4,5 4,75 4,75 5
5
5
4
4
4,5 4,5 4,75 5
5
5,5 5,5
4,5 4,5 4,5 4,5
5
5
5,5 5,5
6
4,5 4,5 4,5
5
5
5,5 5,5
6
6
5,75 5,75 6
6
6
6,5 6,5
7
8
6,75 6,75 7
7
7
7,5
8
8
8
9
9
9
9
9
9
10
10 10,5
11,25 11,25 11,25 11,25 11,25 11,25 11,25 11,75 11,75
13,5 13,5 13,5 13,5 13,5 13,5 13,5 13,5 14

For internal use


Nokia Siemens Networks 2012

N/A
N/A
N/A
2
2
2,75
2,75
3
3
3
3
3
3
3
3
3
3,5
3,5
4
4
4
4
4,75
5
5
5
5,5
5,5
6
6
6
8
8
10,5
12
14

N/A
N/A
N/A
N/A
2,5
2,75
2,75
3
3
3
3
3,5
3,5
3,5
3,5
4
4
4
4
4
4
4,5
4,75
5
5
5
6
6
6
6
6
8
8,5
10,5
12
15

N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
2,75 2,75 N/A N/A N/A N/A N/A N/A N/A N/A N/A
2,75 3,5 3,5 4,25 N/A N/A N/A N/A N/A N/A N/A
2,75 3,5 3,5 4,25 4,25 4,25 4,25 N/A N/A N/A N/A
3
3,5 3,75 4,25 4,25 4,25 4,75 4,75 5,75 5,75 N/A
3
3,5 3,75 4,5 4,5
5
5
5 5,75 5,75 6,5
3,5 3,5 3,75 4,5 4,5
5
5
5 5,75 5,75 6,5
3,5 3,75 3,75 4,75 4,75 5
5 5,75 6,25 6,25 6,75
3,75 3,75 4,75 4,75 4,75 5
5 5,75 6,25 6,25 6,75
3,75 3,75 4,75 4,75 4,75 5
5,5
6
6,5 6,5
7
4
4 4,75 4,75 4,75 5
5,5
6
6,5 6,5
7
4
4 4,75 4,75 5
5
5,5
6
6,5 6,5
7
4
4 4,75 5
5
5,5 5,5
6
6,5 6,5
7
4
4
5
5
5
5,5 5,5
6
6,5 6,5
7
4
4
5
5
5
5,5 5,5 6,5 6,5 6,5
7
4
5
5
5
5,5 5,5
6
6,5
7
7
7,5
4,5
5
5
5
5,5 5,5
6
6,5
7
7
7,5
4,5
5
5
5
5,5 5,5
6
6,5
7
7
7,5
4,75 5
5,5
6
6
6
6,5 6,5
7
7
7,5
4,75 5,75 5,75 6
6
6
6,5
7
7
7
7,5
5 5,75 6
6
6,5 6,5 6,5
7
7,5 7,5 7,5
5
6
6
6
6,5 6,5
7
7
7,5 7,5 7,5
5
6
6
6
6,5 6,5
7
7
7,5 7,5
8
6
6
6,5 6,5
7
7
7,5 7,5
8
8
8
6
6
6,5 6,5
7
7
7,5
8
8
8,5 8,5
6
6
6,5 6,5 7,5 7,5 7,5
8
8
8,5 8,5
6,5 6,5
7
7
7,5
8
8
8,5 8,5
9
9,5
6,5
7
7,5
8
8,5 8,5 8,5
9
9
9
9,5
8
8
8
8,5 8,5 8,5
9
9
9,5 9,5 10
8,5 8,5
9
9
10
10
10
10
11
11
11
10,5 11
11
11
11
12
12
12
12
12
13
12,75 12,75 12,75 13,75 13,75 13,75 14,75 14,75 14,75 14,75 14,75
15
15
15
15
15
15 N/A N/A N/A N/A N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7
7
7
7
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8,5
8,5
8,5
8,5
8,5
8,5
8,5
9,5
9,5
10,5
11
13
15
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8,5
8,5
8,5
8,5
8,5
9
9
9
9,5
9,5
9,5
9,5
10,5
11,5
13
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
7,5
8,5
9
9
9
9
9
9
9,5
9,5
9,5
10
10
11
11,5
14
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
7,5
8
8
8
8
8
8
8
8
8,5
8,5
9
9
9
9
9
9
10
10
10,5
10,5
10,5
11
12
14
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8,75
8,75
8,75
8,75
8,75
8,75
8,75
8,75
8,75
9,5
9,5
9,5
9,5
9,5
9,5
9,5
10
10
10,5
11
11
11
12
14
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8,75
8,75
8,75
8,75
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
10
10,5
10,5
11
11
11,5
12
15
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
8,75
8,75
8,75
8,75
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
10
10,5
11
11,5
11,5
11,5
12
12,5
15
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
9
9
9
9,5
9,5
9,5
9,5
9,5
9,5
9,5
9,5
10
10
10
10
10,5
11
11,5
11,5
11,5
12,5
12,5
15
N/A
N/A

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
9
9
9
9,5
9,5
9,5
9,5
9,5
10
10
10
10
10
10
10
10,5
11
11,5
11,5
11,5
12,5
13
15
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
9
9
9
10
10
10
10
10
10
10
10
10
10,5
10,5
11
11
11,5
11,5
11,5
11,5
13
13,5
15
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
9
9
10
10
10
10
10
11
11
11
11
11
11
11
11
12
12,5
12,5
12,5
13,5
13,5
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10
10
10
10
10
10
10
11
11
11
11
11
11
11
11
12
12,5
12,5
12,5
13,5
14
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
10
10,5
10,5
10,5
10,5
10,5
10,5
11
11,5
11,5
11,5
11,5
11,5
11,5
11,5
12,5
12,5
13
13
14
14
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11
11
11
11
11
11
11
11,5
11,5
11,5
11,5
11,5
11,5
12
12,5
12,5
13,5
13,5
14
14,5
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11
11
11
11
11
11
11
11,5
11,5
11,5
12
12
12
12
12,5
12,5
13,5
13,5
14
14,5
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11,5
11,5
11,5
11,5
11,5
11,5
12
12
12
12,5
12,5
13
13,5
13,5
13,5
14
14
14,5
14,5
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11,5
11,5
11,5
11,5
12
12
12
12
12
12,5
13
13
13,5
13,5
13,5
14
14
14,5
15
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11,5
11,5
11,5
12
12
12
12,5
12,5
13
13
13
13,5
13,5
13,5
13,5
14,5
14,5
14,5
15
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11,5
12
12,5
12,5
12,5
12,5
13,5
13,5
13,5
14
14
14
14
14
15
15
15
N/A
N/A
N/A
N/A

N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
11,5
12
12,5
12,5
12,5
12,5
13,5
13,5
13,5
14
14
14
14
14
15
15
N/A
N/A
N/A
N/A
N/A

HSUPA subunits for CS Voice over HSPA users

24

CS Voice over HSPA users consume Subunits. Up to 18 CS Voice over HSPA


users can be allocated in one Subunit
Number of CS Voice over HSPA users

Subunit

0.25

0.5

13

0.75

18

Each CS Voice over HSPA user decreases the maximum number of HSPA users
allowed by HSDPA and HSUPA scheduler user pool.
CS Voice over HSPA user does not consume Rel99 CE licenses. Each CS Voice
over HSPA user decreases the throughput and the number of users allowed by
the HSUPA Processing Set and the HSDPA Processing Set.
A CS Voice over HSPA user (as a regular HSPA user) has the same priority as
HSPA user
For internal use
Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA dimensioning (1/2)


RU30EP1/EP2 BB resources reservation
To calculate the subunits reservation inside System Module Rel.2 for mixed user type case, (F-DPCH/no
FDPCH/2ms TTI/10msTTI users, 16QAM transmitting users and CS Voice over HSPA), the following rule
should be applied:
HSUPA_Subunits = F-DPCH_2msTTI_Subunits + F-DPCH_10msTTI_Subunits +
no-F-DPCH_2msTTI_Subunits + no-F-DPCH_10msTTI_Subunits + 16QAM_2msTTI_Subunits
+ CS_Voice_over _HSPA_Subunits
Where:
F-DPCH_2msTTI_Subunits = subunits required for HSUPA F-DPCH 2ms TTI users
F-DPCH_10msTTI_Subunits = subunits required for HSUPA F-DPCH 10ms TTI users
No-F-DPCH_2msTTI_Subunits = subunits required for HSUPA no-F-DPCH 2ms TTI users
No-F-DPCH_10msTTI_Subunits = subunits required for HSUPA no-F-DPCH 10ms TTI users
16QAM_2msTTI_Subunits = subunits required for HSUPA 16QAM simultaneously transmitting UEs (RU30EP2)

CS_Voice_over_HSPA_Subunits subunits required for CS Voice over HSPA users.

Note: in some cases presented rule may lead to overestimation of baseband resources

25

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA dimensioning (2/2)


RU30EP1/EP2 HSUPA Processing Sets requirements
In order to reach simultaneously certain number of HSUPA users (data + CS Voice over HSPA) and certain
combined L1 throughput , the following formula should be used to calculate required number of HSUPA BTS
Processing
Sets
Number of HSUPA BTS Processing Sets = max ( HSUPA subunits / 1,5 ; Minimum amount of
HSUPA BTS Processing Sets )

Where:
HSUPA subunits subunits required for HSUPA purpose (see formula)
Minimum amount of HSUPA BTS Processing Sets number of HSUPA BTS Processing Sets calculated for
certain HSUPA throughput or number of HSUPA users (see formula below)
Minimum amount of HSUPA BTS Processing Sets =
max ( Roundup ( Number_of_HSUPA_users / 24) ; Roundup(HSUPA_throughput / 5,8) )
Where:
Number_of_HSUPA_users Number of HSUPA users (data + CS Voice over HSPA)
HSUPA_throughput HSUPA users (data + CS Voice over HSPA) throughput [Mbps]

26

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA BTS Processing Set resources allocation


HSUPA users/throughput distribution

27

Available HSUPA BTS processing set resources needs to be distributed among HSUPA schedulers
If HSUPA scheduler is present in both System Modules (same LCG), in this case BTS will allocate
HSUPA licenses proportionally to baseband capacity for traffic use of each system module, with
BTS processing set granularity.
If Baseband pooling is used then BTS will divide HSUPA licenses between LCGs according to
commissioned share (HSUPA user/throughput license share). Sum of LCG shares is always 100%.
HSUPA licence share is performed with HSUPA BTS processing set licence granularity. If licenses
cannot be share equally between LCGs, in that case BTS will divide higher amount of licenses to
LCG starting from lowest LCG number. E.g.: if commissioned shares are 50% / 50% and there are 5
HSUPA licenses, then LCG1 gets 3 licenses and LCG2 gets 2 licenses.

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

MultiRAB scenario in RU30


HSPA + AMR
MiltiRAB call -> HSPA + AMR
HSPA call (UL:R99,
DL: HSDPA)

AMR call

AMR call

R99

HSDPA

SM rel.2

HSPA call
(UL:HSUPA,
DL: HSDPA)

HSPA call
(UL:R99,
DL:
HSDPA)

28

Exemplary BTS
configuration:
- SM rel.2 + SM rel.2, 1LCG,
Frequency mapping to HW
not used

HSPA call (UL:HSUPA,


DL: HSDPA)

HSUPA

R99

SM rel.2

- AMR call is served with HSUPA resources (Rel.99 CE licenses not needed)
- if HSPA user = non-FDPCH user => no impact on baseband consumption
- if HSPA user = FDPCH user => HSPA user should be treated (-> impact on
HSUPA resources) as HSPA non-FDPCH user
- AMR call needs to be served at the same System Module as HSDPA scheduler
- Additional R99 resources (UL/DL) needs to be allocated for AMR call
- (1 Rel.99 CE license needed)

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

Network Parameters
RAN2123 1 Gigabit Baseband

29

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

New network planning parameters


HSUPA BTS processing set 1
Abbreviated name

numberOfHSUPASet1

Parameter name

HSUPA BTS processing set 1

Data type

Description

Parameter defines number of HSUPA processing set 1 licenses. User shall be able to
select how many HSUPA licenses shall be available in this BTS. Based on that
information required amount of HSUPA licenses are downloaded to BTS from NetAct.
Parameter have additionally special value -1 which means that parameter is not in
use. Note: Not applicable for rel1 HW.

Parameter group

Classification

Operation and Maintenance

Range and step

0 - 99

Default value

One HSUPA BTS Processing Set 1 allows to reach 24 HSUPA users and 5,8Mbps
Note that the HSUPA license (HSUPA BTS processing set) does
not assure maximum throughput to all users simultaneously but it
provides maximum throughput (5.8Mbps) to one user and
minimum throughput to all 24 users.

30

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

New network planning parameters


HSUPA BB decoding capacity
Abbreviated name

hsupaBbDecodCapacity

Parameter name

HSUPA BB decoding capacity

Data type

Description

Defines Minimum HSUPA decoding capacity per LCG in Mbit/s.

Parameter group

Classification

LCELGW

Range and step

0 Mbit/s (0), less than 1.4 Mbit/s (1), 1.4 Mbit/s (2),
2.8 Mbit/s (3), 4.2 Mbit/s (4), 5.6 Mbit/s (5)

Default value

Parameter used for static HSUPA commissioning (together with HSUPA BB minimum users parameter)
Static HSUPA baseband resources can not be taken by R99 traffic in case of license overlapping (Rel99
CE licenses and HSUPA BTS Processing Sets licenses)

31

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

New network planning parameters


HSUPA BB minimum users
Abbreviated name

hsupaBbMinimumUsers

Parameter name

HSUPA BB minimum users

Data type

Description

Defines minimum amount of users allocate to baseband in HSUPA.

Parameter group

Classification

LCELGW

Range and step

0 - 24

Default value

Parameter used for static HSUPA commissioning (together with HSUPA BB decoding capacity parameter)
Static HSUPA baseband resources can not be taken by R99 traffic in case of license overlapping (Rel99
CE licenses and HSUPA BTS Processing Sets licenses)

32

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

New network planning parameters


HSUPA user/throughput licence share
Abbreviated name

shareOfHSUPALicences

Parameter name

HSUPA user/throughput license share

Data type

Description

Parameter defines how many HSUPA licenses belongs to certain LCG. Sum of LCG
shares must be always 100%. No common pool is available. Granularity is one
license. If there is 50%/50% share and 5 lisences, LCG1 gets 3 licenses while LCG2
gets 2 licenses. Parameter have additionally special value -1 which means that
parameter is not in use. Note: Not applicable for rel1 HW.

Parameter group

Classification

LCELGW

Range and step

0 - 100; 1

Default value

Default value of parameter is 100% divided by number of LCGs (max number LCGs
in WN7.0 Flexi is 4). Following default values will be used: 1 LCG => 100%, 2 LCGs
=> 50%, 3 LCGs => 33, 4 LCGs => 25%
HSUPA BTS
Processing set
HSUPA BTS
Processing set
HSUPA BTS
Processing set

33

For internal use


Nokia Siemens Networks 2012

Defines HSUPA license


distribution among LCGs
LCG 1

HSUPA BTS
Processing set
LCG 2

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

HSUPA BTS
Processing set

New network planning parameters


PIC Pool
Abbreviated name

picPool

Parameter name

PIC Pool

Data type

Number

Description

With this parameter operator is able to commission PIC pools in use.

Parameter group
Classification

Operation and Maintenance

Range and step

1...4, step 1

Default value

Master System
Module

Parameter value:
Parameter
picPool (1)value:
Parameter
picPool (2)value:
Parameter
picPool (3)value:
picPool (4)

34

For internal use


Nokia Siemens Networks 2012

Extension
System Module

PIC Pool 1
PIC Pool 2

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

PIC Pool 3
PIC Pool 4

Network planning parameters


HSUPA resource allocation, HSUPA BTS Processing sets

HSUPA BB minimum users

HSUPA BB decoding capacity


HSUPA BTS Processing Set 1 one processing set allows to reach 24 HSUPA users and 5,8Mbps

35

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

Thank you

36

For internal use


Nokia Siemens Networks 2012

MBB CS Network Engineering / Krzysztof Mertas / Bartosz Wrobel

You might also like