After this presentation you will be knowing :

What are DCVs, its type and their uses

About Check Valves and pilot controlled check


valves

What are solenoid actuated valves and their


operation

What are proportional solenoid valves and their


operation

Servo Valve Operation

Servo Valve Connector

RECTIONAL CONTROL VALVE

The primary function of a DC valve is to direct


or prevent fluid flow to specific piping or system
actuator.

These valves usually consists of spool inside it


which is electrically/hydraulically controlled.

There are two fundamental positions of these


valves :
1. Working Position
2. Normal Position


According to no. of valve ports and spool position
DC valve can be categorized into following :
1.
2.
3.
4.

2-way,
3-way,
4-way,
4-way,

2-position
2-position
2-position
3-position and many more

Common Abbreviation used in Hydraulics


P = Pressure line
T = Tank Line
A,B = System Actuator line
X = Pilot Line
Y = Drain Line

Spool Position

2 - Way, 2 Position DC
Valve

3 Way, 2 - Position DC Valve

4 Way, 2 Position DC Valve

4 Way, 3 Position DC Valve


Electrically actuated DC Valves are actuated
by means of solenoid. They can be single/double
solenoid actuated. When these solenoids are
energized the DC valves are shifted to Working
position.

Along with solenoid, there are spring


actuators which are used to shift the spool of a DC
valve to normal position when the solenoid is deenergized.

Single solenoid, 2 position,


Spring Offset

Double Solenoid, 2 - Position

Double Solenoid, 3 Position,


Spring Centre

Common Hydraulic Symbols


1. Continuous line Flow line
2. Dashed line Pilot , drain
3. Spring
4.

Flow Restriction

5.

Single Acting Cylinder

6.

Double Acting Cylinder

7.

2-way, 2-position DC valve (NC)

8.

2-way, 2-position DC valve (NO)

9.

3-way, 2-Position DC valve (NO)

10. 3-way, 2-Position DC valve (NC)

11. 4-Way, 2-position DC valve


12. 4-way, 3-position DC valve
13. Solenoid actuated
14. Hydraulic Actuated
15. Check Valve
16. Pilot operated Check Valve
17. Pressure Relief valve

SOLENOID ACTUATED DC
VALVES
It is an electro-mechanical device that take
electrical energy and produces a linear force by the use
of magnetism. It is basically a winding of wire around a
metal core.

When the solenoid is energized, the air gap is


closed quickly and a force is developed in the direction
of the valve spool.

SOLENOID CONTROLLED, PILOTOPERATED DCV


Although a valve could be shifted directly by the
force of a solenoid, large flow DCVs are most often
shifted using fluid at system pressure. Larger flow
valves demand larger shifting forces and it is no longer
practical to use a solenoid there.

CHECK VALVE

A check valve, non-return valve or one-way


valve is a valve that normally allows fluid to flow
through it in only one direction.

Check valves are two-port valves, meaning they


have two openings in the body, one for fluid to enter
and the other for fluid to leave.

An important concept in check valves is the


cracking pressure which is the minimum upstream
pressure at which the valve will operate.

PILOT OPERATED CHECK VALVE

This type of check valves are remotely operated


through any one of the directional valves.

This is controlled by a pilot pressure line which


is indeed controlled by a directional control valve.

X : Pilot line
A : I/P line to the check valve
B : O/P line from the check
valve

The main application of check valves is to hold


the pressure of a load and for safety purposes.

PROPORTIONAL VALVE

The proportional DCV is actuated by means of


an electrical control signal. The control signal
influences the flow rate and flow direction.

It is exactly the same as the solenoid valve


except that solenoid valve acts as ON/OFF switch
whereas this proportional solenoid valve can achieve
each and every point in between thus varying the flow
rate.

Different flow rate is achieved by varying the i/p


current signal.

DIFFERENCE BETWEEN SOLENOID


AND PROPORTIONAL VALVE
1. Solenoid valve

Normally close position

Fully Open position

2. Proportional Valve

Normally close position

Intermediate Position ( 30% Open )

Intermediate Position ( 60% Open )

Fully Open Position

The difference between a solenoid and a proportional


solenoid valve is in the construction of their spool.

How Signal Flows in It ?


i. Electrical Voltage ( -10V to +10V ) acts upon
amplifier.
ii. The amplifier converts voltage into current
signal.
iii. The current acts upon the proportional
solenoid, which actuates the valve.

an

So, In general a proportional valve is a


combination of both flow control valve and
directional control valve.

SERVO VALVE OPERATION

A hydraulic servo valve is a servo (spool) with a


flapper nozzle system used to position the servo. The
term electro-hydraulic servo valve is often used because
servo valves are controlled through an electrical signal.

The primary components in a servo valve are a


torque motor, flapper nozzle , and spool.

The Servo valve has a hydraulic pressure inlet and an


electrical input for the torque motor. The input current controls
the flapper position. The flapper position controls the pressure in
rod side or piston side of the cylinder. So, a current (+ or -) will
position the flapper, leading to a delta pressure on the servo,
which cause the servo to move in one direction or the other.
Movement of the servo ports hydraulic pressure to one side of the
actuator or the other, while porting the opposite side of the
actuator to return.

Flapper position is controlled by the electromagnetic torque


motor. A torque motor consists of two permanent magnets with a
coil winding attached to a magnetically permeable armature. The
armature is part of the flapper piece. When a current is applied to
the coils, magnetic flux acting on the ends of the armature is
developed. The direction of the magnetic flux (force) depends on
the sign (direction) of the current.


The magnetic flux will cause the armature tips to be
attracted to the ends of the permanent magnets (current direction
determines which magnetic pole is attracting and which one is
repelling). This magnetic force creates an applied torque on the
flapper assembly, which is proportional to applied current.

As the applied current is increased, the armature and


flapper will rotate. As the flapper moves closer to one nozzle, the
flow area through this nozzle is decreased while the flow area
through the other nozzle increases.

In the above the figure the flapper nozzle consists of the


flapper, two inlet orifices (O1and O2), two outlet nozzles (n1and n2),
nozzle backpressure nozzle (n3) and usually a feedback spring. As
described above, the torque motor positions the flapper, which in
turns controls the flow through the nozzles.When the flapper is in
the neutral position, the nozzle flow areas are equal and the
pressures Pn1and Pn2are equal. When the flow areas and inlet
nozzle pressures are equal, the flow forces through each nozzle keep
the flapper centered in the neutral position.


As the flapper moves towards one of the nozzles, the outlet
flow area is reduced for this nozzle. Outlet flow area increases for
the other nozzle. For example, looking at Figure let the flapper
move towards the n1 nozzle. This will reduce the outlet flow area
and the pressure Pn1will increase. At the same time, the outlet
flow area at the n2 nozzle will increase and the pressure P n2will
decrease. A delta pressure P = Pn1 Pn2will occur across the pilot
spool piston and the pilot spool will displace to the right. High
pressure fluid will then flow to the PAactuator chamber while the
PBactuator chamber is ported to return.


Servo valves are normally used when accurate position
and force control is required.

The main advantage of a servo valve is that a low power


electrical signal can be used to accurately position an actuator
or motor.

The disadvantage is complexity and cost which results


from a component consisting of many detail parts manufactured
to very tight tolerances. Therefore, servo valves should only be
used when accurate position (or rate) control is required.

SERVO VALVE CONNECTOR

PIN
FUNCTION
A

SUPPLY VOLTAGE

GROUND

ENABLE INPUT

COMMAND SIGNAL
I/P

VOLTAGE /
CURRENT
RATING
24 V DC

< 6.5 V DC
DISABLED
-10 to +10 mA OR
4 20 mA

E
F

COMMAND SIGNAL O/P

P.E.

4 20 mA

SERVO CONNECTOR
X

POTENTIOMETER

(4 20 mA)

24 v dc

A B C D E
G

CONNECTOR

In No Load Condition
When the wiper is at X end :
Current across DE will be, 24/970 = 24 mA (Apprx. )
When the wiper is at Y end :
Current across DE will be 0 mA.