Carrier Aggregation MOP

.
Prerequisites
• TDD ENB software. (TL16 0000_000172_000002)
• FDD ENB software. (FL16 0000_000186_000000)
• Software to be uploaded on
TDD(TL16_ENB_0000_000577_000060)
• Software to be uploaded on
FDD(FL16_ENB_0000_001382_000)
• There should not be any alarm on Site.
• Port duplex setting to be Auto on TDD and FDD
Pre-check
• CA can be implemented in Outdoor MIMO sector
• On IBS sector CA can not be implemented.
• LNCEL ID should be same of TDD and FDD
• TDD and FDD site should be on latest CA software.
TDD(TL16_ENB_0000_000577_000060)
FDD(FL16_ENB_0000_001382_000)
Cable Connectivity
HDMI cable to be connected in Sync Out of TDD to Sync in of FDD

Optical Cable to be connected between SRIO port of both the FSMF System module
CA Commissioning of TDD
Step 1:-
1.1 Connect ENodeb by LMP port, PC must be setup with following IP
address & Subnet as follows :-
 IP Address :- 192.168.255.130
Subnet Mask:- 255.255.255.0

Step 2:-
2.1 Install the BTS site manager.
2.2 Open BTS Manager and fill the credential and click connect.
2.2.1 Username :- Nemuadmin
2.2.2 Password :- nemuuser
On page no.4 Speed and duplex setting should be on Autodetect mode
On page no 20 we define Sync setting in TDD,where as TDD is Master.

Please do the definition as per attached image


Continued------
On page no.22 Cell resource Commissioning page, please ensure that all outdoor
sector should be on 4TX4RX Configuration,MIMO mode should be 4X2 Closed loop
MIMO and Carrier Power should be 40 dbm
On Commissioning page no.31 CA related parameter to be change first on
LNBTS level as shown in below image.
All parameter can be seen of LNBTS on right side of page in alphabetical order.
Below Parameter to be change in LNBTS level as shown in previous Slide

Parameter LNBTS
Activation of Downlink carrier aggregation TRUE
Activate interenb DL carrier aggegation TRUE
Carrier aggregation cluster id 1
Carrier aggregation cluster Member id 2
Enable Bandwidth Combination Checks TRUE
Min UE-AMBR downlink for carrier aggregation 512
SCell activation cycle period 0.1 s
SCell activation method Nongbrbufferbased
Conservativeness level of SCell activation 1 TTI
SCell deactivation timer eNB Rf128
Sched Carrier Aggr fairness control factor 0
SCell and PCell ambiguous HARQ feedback usage Conservative
On Commissioning page no.31 CA related parameter to be change then on
LNCEL level as shown in below image.
All parameter can be seen of LNCEL on right side of page in alphabetical order.
Below parameter to be changed in LNCEL

Parameter LNCEL ID 1 LNCEL ID 2 LNCEL ID 3


Carrier aggregation pool ID 1 2 3
Max number carrier aggr configured UEs 50 50 50
Max number Carrier Aggr configured UEs double carrier 50 50 50
Max number carrier aggr configured UEs 3 Carriers 20 20 20
Max number of secondary cells for DL carrier aggr 1 1 1
Number of PUCCH PRBs for HARQ format 3 0 0 0
ACK/NACK offset 72 72 72
PUCCH bandwidth for CQI 3 3 3
Cell scheduling request periodicity 20 20 20
CQI periodicity network period 40ms 40ms 40ms
Periodic CQI subbands cycles 1 1 1
Delta cyclic shift for PUCCH 1 1 1
Multiplier M for periodic RI reporting period 1 1 1
Rank indication reporting enable TRUE TRUE TRUE
Periodic CQI feedback type Wideband Wideband Wideband
Activate outer link adaptation TRUE TRUE TRUE
Additional active UE with reason radio reason handover 45 45 45
Additional active UE with reason time critical handover 50 50 50
Maximum number of RRC connections 150 150 150
Maximum number RRC emergency 200 200 200
PRACH frequency offset 13 13 13
Then Finally Finish Commissioning and Save the changes
CA Commissioning of FDD
Step 1:-
1.1 Connect ENodeb by LMP port, PC must be setup with following IP
address & Subnet as follows :-
 IP Address :- 192.168.255.130
Subnet Mask:- 255.255.255.0

Step 2:-
2.1 Install the BTS site manager.
2.2 Open BTS Manager and fill the credential and click connect.
2.2.1 Username :- Nemuadmin
2.2.2 Password :- nemuuser
Duplex setting Should be on Autodetect in FDD also
On page no 20 we define Sync setting in FDD,where as FDD is Slave.

Please do the definition as per attached image


On page no.22 Cell resource Commissioning page, please ensure that all outdoor
sector should be on Closed Loop MIMO
Continued--
On Commissioning page no.31 CA related parameter to be change first on LNBTS
level as shown in below image.
All parameter can be seen of LNBTS on right side of page in alphabetical order
Below Parameter to be changed in LNBTS of FDD Site

Parameter LNBTS
Activation of Downlink carrier aggregation TRUE
Activate interenb DL carrier aggegation TRUE
Carrier aggregation cluster id 1
Carrier aggregation cluster Member id 1
Activation of Complete consistency checks TRUE
Enable Bandwidth Combination Checks TRUE
Min UE-AMBR downlink for carrier aggregation 512
SCell activation cycle period 0.1 s
SCell activation method Nongbrbufferbased
Conservativeness level of SCell activation 1 TTI
SCell deactivation timer eNB Rf128
Sched Carrier Aggr fairness control factor 0
SCell and PCell ambiguous HARQ feedback usage Conservative
Activate flexible base band usage TRUE
Activate enhanced AC and GBR services TRUE
On Commissioning page no.31 CA related parameter to be change then on LNCEL level
as shown in below image.
All parameter can be seen of LNCEL on right side of page in alphabetical order.
Below Parameter to be Set in LNCEL of FDD

Parameter LNCEL1 LNCEL2 LNCEL3


Carrier aggregation pool ID 1 2 3
Max number carrier aggr configured UEs 50 50 50
Max number Carrier Aggr configured UEs double carrier 50 50 50
Max number carrier aggr configured UEs 3 Carriers 20 20 20
Max number of secondary cells for DL carrier aggr 1 1 1
Number of PUCCH PRBs for HARQ format 3 0 0 0
ACK/NACK offset 72 72 72
PUCCH bandwidth for CQI 3 3 3
Cell scheduling request periodicity 20MS 20MS 20MS
CQI periodicity network period 40MS 40MS 40MS
Periodic CQI subbands cycles 1 1 1
Delta cyclic shift for PUCCH 1 1 1
Multiplier M for periodic RI reporting period 1 1 1
Rank indication reporting enable TRUE TRUE TRUE
Periodic CQI feedback type Wideband Wideband Wideband
Activate outer link adaptation TRUE TRUE TRUE
Additional active UE with reason radio reason handover 15 15 15
Additional active UE with reason time critical handover 20 20 20
Maximum number of RRC connections 324 324 324
Maximum number RRC emergency 360 360 360
PRACH frequency offset 4 4 4
Aside Very imp object CAREL to be created under WCEL as shown in image
Below Parameter to be set in each CAREL

Parameter CAREL
Carier aggregation relation identifier 1
BTS ID of the parent eNB of the cell to be aggregated
enB id of TDD site
Local Cell resource ID of cell to be aggregated 1-First cell,2-Second cell---
PCELL Swap alowed allowed
Scell Priority 1
Then Finally Finish Commissioning and Save the changes
THE END