Agenda

 About LAG

 LAG/LAGU Physical Installation

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Introduction

 LAGU system is Line Access Gateway Unit system.


 LAGU system is installed at RBM and co-located BM sites.
 A BM system is converted to LAGU system replacing BPU and TSU
with NGTJ cards and TSI cards.
 All TUs with PSUs, TCs (LCC), TIC, SPC and TUI cards are retained.
 2-slot chassis consists of NGTJ card and TSI card interfacing with
TUI cards in ATU frame.
 Two types of Base Modules in one MAX system are:
 Co-located BMs which are housed in the same building in which
Central Module is housed.
 Remote Base Modules which are located remotely and are connected
to a Central Module typically E1 links. 9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


continued……..

 C-DOT LAGU is designed to migrate fixed line TDM based


technology of DSS-MAX to IP based technology.

 It converts basic voice into RTP and Signaling information to SIP


and connects to the IP network.

 LAGU provides gateway functionality through a pair of network


gateway cards working in active-standby mode.

 LAGU systems are installed at all co-located and remote Base


Modules of the MAX exchanges.

Copyright © 2015 C-DOT. All Rights Reserved


continued……..

 There will be no change in the end user interfaces.

 E1 link shall remain unaffected by the migration exercise.

 Supports maximum 32 E1s from RBM site to co-located BM site.

 BM in concentration supports maximum 2K subscribers at remote BM


site.

 Call processing and feature handling by centralized softswitch.

Copyright © 2015 C-DOT. All Rights Reserved


continued….
 Terminal Interface Controller (TIC) controls the four terminal groups
(TG) of 32 channels and multiplex them to form a duplicated
128channel,8 Mbps link towards NGTJ card.

 For signaling information of 128 channels, it communicates with


Signaling Processor (SP) to receive/send the signaling events on
analog terminations.

 In concentration, three other Terminal Units share the 128 channel


link towards the NGTJ card to have 4:1 concentration.

Copyright © 2015 C-DOT. All Rights Reserved


Key requirements during
upgradation
 BPU and TSU frame is replaced with 2-slot chassis,NGTJ cards and TSI
cards

 There will be no change in the existing TU frame having line cards,


PSU, TIC, SPC and TUI.

 TSI cards will be interfaced with TUI in ATU frame just like as was in
case of BPU and TSU.

 Power Supply of -48V to be supplied to NGTJ cards in 2-slot chassis.

Copyright © 2015 C-DOT. All Rights Reserved


LAGU & TU

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
S S
P P
P P
T C T T T C
S T T T T T T T T T T T T T T T T S
I / U U I /
U C C C C C C C C C C C C C C C C U
C I I I C I
I I
S S
P P

Copyright © 2015 C-DOT. All Rights Reserved


LAGU Physical Installation
 For upgrading MAX to LAGU system, BPU & TSU to be replaced
by LAGU chassis as shown in next slides.

 Chassis to be mounted in the BM through nuts & LN key.

 5V, 12V DC are used for driving TSI cards which is fed from ATU.
Both the cables (5V/12v) are fed from different ATU. If one ATU
fails, LAGU will not be affected as it will work in simplex mode.

 Two slot chassis contains two NGTJ and two TSI cards.

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


TSI card

LAGU Chassis with 2


NGTJ
cards & 2 TSI cards

NGTJ card

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


NGTJ card

Copyright © 2015 C-DOT. All Rights Reserved


9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


LAGU Chassis
 LAGU chassis contains two NGTJ & two TSI cards.

 TSI cards interface with TUI cards in ATUs through TT cables.

 NGTJ can be installed in either simplex or duplex mode.

 NGTJ variants are NGTJ-A00 (EEB integrated) and NGTJ-B00 (EEB not
integrated).

 LAGU Chassis operates at -48V DC.

 5VDC & 12 VDC for LAGU is fed from ATU.


9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Continued….
 Physical card Installation
 TSI
 LAG

 Ethernet connection

 EEB connection

 Serial ports copy-0 or copy-1 in NGTJ can be accessed through


minicom in PC/Laptop with the help of serial cable.

 LED 9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


LAGU cable details
 Two -48Vdc power cable ( 4 cores )

 Two green chassis cables

 Two TU-TSI 5Vdc/12Vdc cables

 Two Ethernet cables

 16 TT cables

 Two minicom cables


9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


LAGU chassis after installation

LAGU chassis is installed replacing BPU & TSU 9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Back-plane of 2-slot chassis

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Back plane of LAGU chassis
after Installation

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Power supply connection
 -48VDC is fed from both bus-bar to LAGU chassis in
duplex mode

 Blue wire is for -48VDC

 Red wire is for reference 0 volt

 Yellow/yellow-green wire for digital ground

 Green wire is for chassis Ground


9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Power Supply Connection

LAGU Chassis

LAGU Chassis
9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Bus-bar power connection

Bus-bar

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


TT cable connection

 There are four terminal units (TU1,


TU2, TU3, TU4)

 TT cable connection (back-view)


between TSI & TUI cards is shown below

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


TT cables interfacing TSI and TUI
cards

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


TSI power (5Vdc & 12Vdc) connection
At LAGU
5V/12Vdc fed from TU

AT LAGU

5V/12Vdc fed from TU


9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


AT LAGU
Minicom connection
• Serial cable is for accessing serial communication. There are two
minicom ports in LAGU chassis for copy-0 & copy-1 NGTK cards.
• Serial cable is connected b/w minicom port in LAGU chassis and
PC/Laptop.

PC side

Minicom

9/20/18
9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


LAGU connectivity

Ethernet ports

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Conversion of a Line BM/RBM to Line Access Gateway

Line Line Line


Cards Cards Cards

Control Control Line Access


Cards Cards Gateway Unit

Existing Base Module Migrated Base Module


Copyright © 2015 C-DOT. All Rights Reserved
LAGU connectivity

E1 to CACU site
EEB/
EEB E1 DDF DDF E1
MLS Uplink to
/CACU core

ETHERNET E1

LAGU SYSTEM
LAGU SYSTEM
(A00)-EEB
INTEGRATED
LAGU SITE CACU SITE

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Connectivity for co-located BM

MLS
ETHERNET ETHERNET
EEB
BM /LAG BM /LAG
V5AG/PRIAG

SG/MG

SLM

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Access connectivity

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Access/Core connectivity

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


Here is the LAGU Installation Video
(Total:-27 Minutes)

9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


9/20/18

Copyright © 2015 C-DOT. All Rights Reserved


34

THANK YOU

Feedback :- cdotmaxng@gmail.com
9/20/18

Copyright © 2016 C-DOT. All Rights Reserved

You might also like