You are on page 1of 21

VALLIAMMAI ENGINEERING COLLEGE

DEPARTMENT OF CIVIL ENGINEERING

CE 6712 –DESIGN PROJECT

DESIGN OF RESORT
FIRST REVIEW
DATE:22-08-2018

DONE BY
R.GOWTHAM (412815103305)

UNDER THE GUIDANCE OF


Mr.S.KARTHICK M.E.,
(ASSISTANT PROFESSOR)
INTRODUCTION

• The resort is an isolated place, self-contained commercial


establishments that tries to provide most of vacationer’s wants such
as food, drinks, lodging, sports and entertainment on the premises.

• It is a tourist place which contains villas, swimming pools, reception


area, parking area, indoor playing area for the people to enjoy their
vacation.
OBJECTIVE
• To design a slab
• To design a beam
• To design a column
• To design a footing
• To design a concrete wall for swimming pool
COMPONENT OF RESORT

• Reception building
• Party hall
• Villa building
• Swimming pool
METHODOLOGY

SITE SELECTION

ANALYSIS

DESIGN OF STRUCTURE ELEMENTS

RESULT

CONCLUSION
DIMENSIONS OF STRUCTURE
DESCRIPTION LENGTH (m) BREADTH AREA(m^2)
(m)
RECEPTION 4.8 6.8 32.64
ROOM
INDOOR PLAY 3.45 6.8 23.46
TOTAL 56.1
RECEPTION AREA
PARTY HALL 8.55 6.8 58.14
DIMENSION OF STRUCTURE
DESCRIPTION LENGTH (m) BREADTH (m) AREA(m^2)
LIVING ROOM 5 5 25
BED ROOM 1 4 4 16
TOILET 1 4 2.3 9.2
BED ROOM 2 4 4 16
TOILET 2 4 2.3 9.2
KITCHEN 3 3 9
DINING ROOM 3 2 6
SWIMMING POOL 6 4.5 27
TOTAL AREA OF 117.4
ONE VILLA
TOTAL AREA OF 352.2
THREE VILLAS
TOTAL AREA OF 466.44
RESORT
RESORT PLAN
VILLA PLAN
RECEPTION PLAN
PARTY HALL PLAN
LITERATURE STUDY
Author Title Abstract

T.K.Khoshtaria The planning of The article discusses


urban green areas and the problem of green
its protective areas reduction and
importance in resort degradation in
cities (case of southern Georgia for
Georgian resorts) three resorts cities
located in Samtskhe-
Javakheti region.
REFERENCE

 IS 456 - (2000) : Plain and Reinforced Concrete-code of Practice.


 SP-16:1980: Design Aids For Reinforced Concrete.
NBC National
DESIGN OF SLAB
2.1 DESIGN PROCEDURE;
The entire design process is carried out using limit state procedure. IS456 and
SP16 are used as reference for the design. these design procedures for
slab,beam,column and footing aer explained below.
Desigof a slab

Type : Simply supported


Lx - Shorter span
Ly - Longer span
Dimensions:
Ly =5m
Lx =5m
Fck =20 N/mm
Fy =415N/mm
(Ly/Lx) = 1<2
Hence its a two way slab.
Depth of slab :
Depth = (Span/25)
Effective depth, d = (5000/25)
= 200mm
Over all depth, D = 200+25
= 225mm
Effective spane = 5+.225
(Le)= 5.225m
Loads :
Selfe-weight of slab =(0.225x25)=5.625 KN/m²
Live load = 2.0 KN/m²
Floor fnishes = 1.0 KN/m²
Service load = 8.625 KN/m²
Factor load =12.937KN/m²

Ultimate Design moment & shear :


From IS Code 456:2000, Table no :26
Mux = 21.9KN.m
Muy = 21.9KN.m
Vu = 32.32 KN

CHECK FOR DEPTH :


Mmax = 0.135 Fck b d²
d = (Mmax/0.138 Fck)½
d = 89.07<200mm
(Hence safe)
Reinforcements:
Mu = 0.87 fy Ast d (1-(Ast fy/bd fck) (Longer span)
72210 Ast – 7.49 Ast² - 21.9x10⁶
Ast = 331 mm²
Therefore, adopt 10mm diameter bars:
Spacings = (0.785x10²/331)x 1000
= 237 ~ 200mm
Provide 10mm dia bars @ 200mm c/c spacing.
Mu = 0.87fy Ast d (1-(Ast fy/bd fck) (shorter span)

72210 Ast – 7.49 Ast²-21.9x10⁶


Ast =331mm²
Therefore, adopte 10mm dia bars :
Spacings = (0.785x10²/331)x 1000
=237 ~200mm
Provide 10mm dia bars @ 200mm c/c spacing
Check for shear:
Ʈv = Vu/bd
= (32.32x10³/1000x200)
Ʈv = 0.16 N/mm²
Pt = (100xAst/bd) = (100x392/1000x200)
Pt = 0.196
Using IS Code 456:2000, Table No.19
KƮc = 0.36
=Ʈc >Ʈv
Hence its safe.
DESIGN OF BEAM
Member details
clear span = 5m
Width of beam (b) = 300mm
Depth of beam (D) = 400mm
Cover depth (d = 25mm
Ultimate design moment & shear :
Mu = 105 kN.m
Vu = 79.23kN
Mu,lim = (0.138fck b d²)
=(0.138x20x300x350²)
Mu lim = 101.43x10⁶ KNm
Therefore, Mu<Mu,lim
Reinforcements:
Mu = 0.87fy Ast d (1-(Ast fy/bd fck)
105.0x10⁶ = 126367.5 Ast-24.97Ast²
Ast=1053.29mm²
provide 6 nos of 16mm dia bars
No of bars = (1053.29/0.785x16²)
= 5.23~ 6 Nos
Hence provide 6 nos of 16mm dia bars.
Check for shear:
Ʈv = (Vu/bd)
= (79.23x10³/300x400)
Ʈv = 0.660
OTHER SLAB REINFORCEMENT DETAILS

SLAB MAIN SPACING DISTURBUTION SPACING


N0 : REINFORCEMENT (MM) REINFORCEMENT (MM)
Along X-Axis (mm²) Along Y-Axis (mm²)
S1 331 200 331 200
S2 424 230 319 250
S3 473 210 358 245
S4 250 197