You are on page 1of 29

Security Level:

Using PCHR to Analyze


TP & coverage

www.huawei.com

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


TP Analysis

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 2


Step 1

Click here to open Statistic


window

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 3


Step 2

Version

CHR location

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 4


Step 3

Click here to do TP analysis


The location you’d
Like to store the result

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 5


TP Result

TP

1 TP = 234 meter

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 6


TP vs Cell ID

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 7


Step 1
From here to open Set Config

Version

CHR folder

Folder to store the filtered result

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 8


Step 2

Put values for getting filtered CHR with samples between 0 and 9

Double click here


HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 9
Step 3

Begin filter

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 10


Step 3 result

Filter complete. It means the CHR record only relating to the TP=0 to 9
Is stored in the folder you specified in page 8
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 11
Step 4

Click here to open Statistic


window

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 12


Step 5

Version

The filtered data location that


You specified in page 8

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 13


Step 6

Double click here to get CI versus Samples result in


The specified TP range

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 14


TP vs EcIo (RSCP)

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 15


Step 1
From here to open Set Config

Version

CHR folder

Folder to store the filtered result

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 16


Step 2

Input which TP you’d like to filter

Click here to open the tab

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 17


Step 3

Begin filter

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 18


Step 3 result

Filter complete. It means the CHR record only relating to the TP=0
Is stored in the folder you specified in page 8
HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 19
Step 4

Click here to open Statistic


window

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 20


Step 5

Version

The filtered data location that


You specified in page 8

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 21


Step 6

Click to analyze RSCP or EcIo of RRC setup

The location you’d


Like to store the result

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 22


The EcIo distribution of TP 0

EcIo of RRC Setup

Go back to page 9 and input 1,2


3,….,9,10, then repeat the steps.
Finally you can get the RSCP or
EcIo count at different TP

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 23


Example of final result
140 -116
120 -115
-114
100
-113
80
-112
60 -111
40 -110

20 -109
-108
0
-107

-54
-61
-66
-71
-106

-76
-81
-86
9 -105
-91
6 5
-96
4
-101

3
-106

2 -104
-111

1
-116

0
-103
TP vs EcIo

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 24


Use CHR to do coverage analysis

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 25


Step 1: filter the CHR according to RRC access cell

2. After click OK, directly start to filter TP

1. Input cell id you want to


filter

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 26


Step 2 & 3

• Step 2: Filter TP (do it like in page 9)


• Step 3: Get statistic of RSCP & EcIo (refer to page 3)
By this, you could get the TP vs RSCP (EcIo) of the cell then
know the covering area and signal

The RSCP is almost below


-95dBm
in the area that’s 200m away
from
the site, so need coverage
optimization

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential Page 27


-First step is to give source CHR PATH and filtered CHR path.

-Then select the appropriate option as per the requirement.(either TP, CI etc)
-Then start begin filtering
-Once finished do PCHR statistics (mention filtered CHR location at this step)
and execute the appropriate option (TP vs sample for a particular CI)
In this case CI is the filter condition while TP analysis is the appropriate option.

HUAWEI TECHNOLOGIES CO., LTD. Huawei Confidential


Thank you
www.huawei.com

You might also like