You are on page 1of 38

WaveStar DACS 4/4/1

Introduction and O&M

Patrick Wu

QACC &TSO
Presentation Outline

Product Introduction

System Architecture
Physical Architecture and Circuit Pack Introduction

O&M on CIT

Troubleshooting case study

2 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Product Introduction

Large-capacity cross-connect system for backbone, metro and


access space

Provides flexible bandwidth management in a Synchronous


Digital Hierarchy (SDH) environment.

Supports grooming and restoration capabilities

Fully Non-Blocking Cross-Connect capacity

512 STM-1 equivalent capacity

Cross-connections at the AU-4-4c, AU-4,


AU-3, TU-3, and TU-12

STM-1(e), STM-1(O), STM-4, STM-16 interfaces


Multiple protection schemes supported
Interconnects STM-1/4/16 rings

3 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Product Introduction - Basic Configuration

STM-16, STM-4, STM-1 e/o

STM-16 WS DACS STM-16

STM-4 STM-4
AU-4-4c, AU-4,
STM-1e/o AU-3, TU-3, TU-12 STM-1e/o

STM-16, STM-4, STM-1 e/o

4 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Architecture

Network System Envelope Office


Management Control
Interfaces Interfaces
System
Controller

Data
AU-3/4
Protocol
Transport
I/O I/O Interfaces
STM-0 STM-1
Cross-connect
Cross-connect
Matrix
Matrix
I/O
I/O
STM-16
STM-4

5 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Architecture – Bit Slice Concept

Cross-connect
Subrack

b1
BSIU BSSU BSIU
b2
BSIU BSSU BSIU
b3
BSIU BSSU BSIU
b4
BSIU BSSU BSIU
b5
IU PU BSIU BSSU BSIU PU IU
b6
BSIU BSSU BSIU
b7
BSIU BSSU BSIU
b8
BSIU BSSU BSIU
p1
BSIU BSSU BSIU
p2
BSIU BSSU BSIU

6 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Architecture – Bit Slice Concept (cont’d)

Bit 1
e
il c Bit 2
tS
Bi Bit 3
Input Signal
Bit 4
Bit 5
Bit 6
Bit 7

Bit 8
Protection Bit 1
2:8 Shared Protection
Protection Bit 2

7 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Architecture – Transport Architecture

System
Envelope STM-16
STM-4

Port Subrack
Port Subrack
STM-4 STM-16
Cross-connect
Matrix
N2
Bit Slice
STM-1 E/O STM-1 E/O

Port Subrack
Port Subrack

PDH&Ethernet PDH&Ethernet

ADM 16/1 ADM 16/1

DS1, E1, E3, DS3 DS1, E1, E3, DS3


E4, 10/100 Base-T A maximum of 16 port subracks is supported E4, 10/100 Base-T
GbE GbE
in a 512 STM-1 equivalent configuration.

8 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Architecture – Control Architecture

XC-CIT(GUI)
Main
Controller

MainController
Main ControllerLAN
LAN

Subrack Controller Subrack Controller Subrack Controller Subrack Controller

Matrix
and STM-1 Port STM-4 Port STM-16 Port
Synchronization Subrack Subrack Subrack
Subrack PSA PSC PSC

9 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Architecture
Protection

Equipment protection

Main Controller (MC)  1:1


Matrix Slice (BSSU+BSIU)  2:8

Matrix and Synchronization subrack (MS)  1:1

Digital Timing Unit (DTU)  1:1


STM-1 electrical interfaces (PU)  1:8

Transmission protection

Sub-network Connection Protection (SNCP)


1+1 Multiplex Section Trail Protection (MSP)

10 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Physical Architecture
Core Racks

STU

SRC
BSC
Synchronization
MPU

MSU
MSU
MSU

Main Subrack
User

STU

SRC
BSC
Controller
Subrack
oo
o
Panel
oo
(1+1 duplicated)

BSSU
BSSU
BSSU

BSSU

BSSU
BSSU
BSSU

BSSU

BSSU
BSSU

Cross Cross
Connect Connect
Subrack Subrack

Cross Connect and Cross Connect and


Main Controller Rack Synchronization Rack
11 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Physical Architecture
Core Racks – Main Controller (MC) subrack – front view

MPU — Main Processor Unit

The MPU provides the following:

– Central processing function

– Control of the ARU and the LHU

– A narrow Small Computer System Interface


(SCSI-2) to the MSU.

• MSU — Mass Storage Unit

The MSU contains a fixed-medium hard disk drive


and a removable-medium optical disk drive.

12 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Physical Architecture
Core Racks – Main Controller (MC) subrack – rear view

• LHU — LAN Hub Unit

The LHU provides the hub ports necessary for


the LAN connections in the system.

• NIC TM — Network Interface Chip


Transition Module

The NIC TM provides LAN access to the MPU.

• SCSI TM — SCSI Transition Module

The SCSI TM provides a narrow SCSI-2


ARU — Alarm Relay Unit interface between the MPU and the MSU.
The ARU provides interfaces to the system • Serial TM — Serial Transition Module
alarm indicators, a network interface to the
The Serial TM provides serial access to the
LHU, and a narrow Small Computer
MPU.
Interface-2 (SCSI-2) to the MSU.

13 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Physical Architecture
Core Racks – Matrix and Synchronization (MS) subrack – front view

• STU — System Timing Unit

The STU provides system timing and synchronization.

• BSC — Bit Slice Controller

The BSC works with the STU to provide timing signals


for internal transmission paths and control information
for the BSSUs (cross-connect matrix components).

• SRC — Subrack Controller

The SRC routes messages back and forth from the Main
Controller to units in the subrack.

14 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Physical Architecture
Core Racks – Matrix and Synchronization (MS) subrack – front view

PTM — Power Terminal Module

The PTM filters incoming station power from two


separate power lines and distributes it across the
subrack midplane.

OLU — Optical Link Unit

The OLU is part of the internal transmission path. It


provides interfaces for the optical-fibre cables that
carry transmission data between the BSCs and the
BSSUs. The OLU also provides interfaces for the optical-
fibre cables that carry timing information between the
duplicated BSCs in the Matrix and Synchronisation
subrack.

15 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
elect/opt.
elect/opt.

64 x STM-1
64 x STM-1

16 | Presentation Title | Month 2006


I/O Racks-STM-1

STM-1 STM-1 STM-1 STM-1


STM-1 STM-1 STM-1 STM-1
STM-1 STM-1 STM-1 STM-1
STM-1 STM-1
Physical Architecture

STM-1 STM-1
STM-1 STM-1 STM-1 STM-1
STM-1 STM-1 STM-1 STM-1
STM-1 STM-1 STM-1 STM-1
STM-1 STM-1 STM-1 STM-1

Front view
STM-1P STM-1P STM-1P STM-1P
DTU DTU DTU DTU
SRC SRC

PTM BSIU PTM PTM BSIU PTM


BSIU BSIU

All Rights Reserved © Alcatel-Lucent 2006, #####


IU BSIU IU IU BSIU IU
IU BSIU IU IU BSIU IU
IU BSIU IU IU BSIU IU
IU BSIU IU IU BSIU IU
IU BSIU IU IU BSIU IU
Rear view

IU BSIU IU IU BSIU IU
IU BSIU IU IU BSIU IU
IU BSIU IU IU BSIU IU
System Architecture – Physical Architecture
I/O Racks-STM-1, Port Subrack A, PSA – front view

STM1 — STM-1 Port Unit

The STM-1 port unit has four STM-1 ports.


Each STM-1 port provides 155.52 Mbit/s
transmission.

• DTU — Digital Timing Unit

The DTU provides timing for the


transmission units in the subrack.

• SRC — Subrack Controller

The SRC routes messages back and forth


from the Main Controller to units in the
subrack.

17 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Architecture – Physical Architecture
I/O Racks-STM-1, Port Subrack A, PSA – front view
• PTM — Power Terminal Module

The PTM filters incoming station power from two


separate power lines and distributes it across the
subrack midplane.

• BSIU — Bit Slice Interface Unit

The BSIU is part of the internal transmission path. It


transports data between the BSSUs and the port
units. The BSIU also monitors the transmission data
and provides Automatic Protection Switching for
hardware failures.

• IU — STM-1 Interface Unit

The STM-1 interface unit (IU) provides the SDH


Physical Interface (SPI) function for STM-1 electrical
or optical signals. The IU provides four STM-1
interfaces.

18 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
OAM on CIT

Login process

Main Menu overview


Equipment Details

Equipment Protection

System backup
Alarm/Log

19 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Login process

20 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Main menu overview

21 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Details

Rack Information

Subrack Information
Unit Information

System ID

22 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Details
Rack Information

Provision  Equipment

23 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Details
Subrack Information

Provision  Equipment

24 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Details
Unit Information

Provision  Equipment

25 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Details
System ID

Provision  System ID

26 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Protection

MC Control

MS Control
Matrix Slice

DTU

27 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Protection
MC Control

Protection  Equipment

28 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Protection
MS Control

Protection  Equipment

29 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Protection
Matrix Slice

Protection  Equipment

30 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Equipment Protection
DTU

Protection  Equipment

31 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
System Backup

Utilities  Backup Database

32 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Alarm/Log

Current Alarms

Autonomous Events
Defect Report

33 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Alarm/Log
Current Alarms

Alarms  Current Alarms

34 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Alarm/Log
Autonomous Events

Reports  Autonomous Events

35 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Troubleshooting case study

LOA or CIT cannot login

Interface failure condition

36 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Troubleshooting case study
LOA or CIT cannot login

1. MC protection switch to the originally-standby MC

2. Reinstall OS/NEF files


3. Replace the unit in the problematic MC (mostly MSU)

4. Others

5. Periodically database backup

37 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####
Troubleshooting case study
Interface failure condition

• Bit Slice Fibre Interface (BSFI) — OLU to BSSU

• Equipment Core Interface (ECI) — BSSU to BSIU


• Equipment Physical Interface (EPI) — BSIU to port unit

• Port Subrack Control Interface (PCI) — BSIU to DTU, STU to BSC, DTU to port
unit

• Cross-couple link between the working DTU and the protection DTU in a
port subrack

Both unit might be the cause for the INTFcEQ condition

38 | Presentation Title | Month 2006 All Rights Reserved © Alcatel-Lucent 2006, #####

You might also like